Download Lightolier Guardsman Vandal Resistant GSW SERIES User's Manual
Transcript
Guardsman Vandal Resistant Page 1 of 2 GSW SERIES Ceiling or Wall Mounted Fluorescent 6" Width, 3-7/8" Deep, 24" or 48" Nominal Length, 1 or 2 Lamp T8 Features • Excellent for locations where vandal resistance is required, areas such as hallways, stairwells, locker rooms, parking garages and psychiatric hospitals. • For ceiling or wall mounted applications. • Can be vertically or horizontally mounted on wall. • 20 gauge cold rolled steel, post painted, baked white enamel housing. • 18 gauge cold rolled steel post painted baked white enamel end caps, standard. • Linear prismatic lens 50% DR (impact resistant) and 50% standard acrylic with nominal thickness of 1/8", withstands 70 ft lbs impact without breaking. • Tamper resistant holt head screws secure ends to housing. • Only 3-7/8" deep, meets American with Disabilities Act for wall mounted fixtures. • Nominal 2' and 4' lengths. • 73.9% efficient (T8 lamps). Dimensions 7/8" dia. K.O. (2) 6" (152mm) 9/32" hole (2) 4" (102mm) 6" (152mm) 3-7/8" (98mm) 23-15/16" (608mm) 9/32" hole (2) 7/8" dia. K.O. (3) 1-7/8" dia. K.O. End Cap 4" (102mm) 6" (152mm) Threaded Nipple End Cap Nut Nut 24" (610mm) 48" (1219mm) Nut Required to space fixtures apart so ends can be removed or installed. For Continuous Row Mounting Job Information T ype: Job Name: C at. N o. : Lamp(s): V olts/Ballast: 9/03 Lightolier a Genlyte Thomas Company www.lightolier.com Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2003 Lightolier Section 6A/Folio P10-62 GSW SERIES Guardsman Vandal Resistant Ceiling or Wall Mounted Fluorescent 6" Width, 3-7/8" Deep, 24" or 48" Nominal Length, 1 or 2 Lamp T8 Photometry LER = FP - 62.9 IW - 59.1 BF - 0.88 Comparative yearly lighting energy cost per 1000 lumens = $4.06 Model No. GSW4232120SO coefficients of utilization — zonal cavity method RF 20 RC 80 RW 70 50 30 1 81 76 73 2 73 66 61 3 66 58 51 4 61 51 44 5 56 46 39 6 51 41 34 7 48 37 30 8 44 34 27 9 41 31 25 10 39 29 23 visual comfort probability room size ceiling height W L 8.5 10.0 13.0 20 20 40 47 58 20 30 35 40 46 20 40 33 36 41 20 60 32 35 38 30 20 38 45 55 30 30 32 37 43 30 40 30 33 38 30 60 29 32 34 30 80 29 31 33 40 20 38 45 53 40 30 31 36 42 40 40 29 32 36 40 60 27 30 32 40 80 27 30 31 40 100 27 30 31 60 30 31 36 41 60 40 28 31 35 60 60 26 29 31 60 80 25 28 29 60 100 25 27 29 100 40 29 31 34 100 60 25 28 30 100 80 24 26 28 100 100 23 26 27 room cavity ratio G97001 GSW4232120SO luminaries lengthwise ADVANCE RIC2S32TP SOLID STATE OCTRON BALLAST THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE. 20 50 30 65 54 46 40 35 31 28 25 23 21 50 67 58 51 46 41 37 33 31 28 26 16.0 69 56 47 42 66 52 43 39 37 64 51 42 37 35 34 49 41 36 33 32 40 34 32 30 10 62 51 42 36 31 27 24 21 19 17 luminaries crosswise Page 1 of 2 50 62 54 47 42 38 34 31 29 26 24 8.5 30 20 15 11 32 22 16 12 10 34 24 18 13 10 9 25 19 14 11 9 23 16 13 11 ceiling height 10.0 13.0 39 53 27 35 20 26 15 19 40 51 27 35 20 26 15 19 12 15 42 52 29 36 22 26 16 19 13 15 11 13 31 37 23 27 17 20 14 16 11 13 27 30 20 22 16 18 13 15 20 30 30 60 51 43 38 33 29 26 24 22 20 10 58 48 40 34 29 26 23 20 18 17 16.0 66 48 35 25 64 46 33 25 20 63 46 33 25 20 16 47 34 25 20 17 37 27 22 18 Ordering Information Explanation of Catalog Number. Example: GSW4232120SOEM GSW GSW: Guardsman Surface/Wall Vandal Resistant Fluorescent Fixture Length: 2 = 24" 4 = 48" Lamp Quantity: 1 or 2 Lamps Lamp: (By Others) 17 = T8 2' Length 32 = T8 4' Length Voltage: 120 or 277 Ballast Type: Options: < 20THD < 10THD Add appropriate suffix to catalog 1-2 Lamp Elec. T8 SO* HI* no, ie: (EM) 0° Starting T8 SD* – LOL Dimming T8 PS* – *Instant Start Standard Other dimming options, consult factory. Options & Accessories Specifications (continued) In-Line Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF. Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. Suffix: R. One per ballast. Suffix: B. Emergency Power Pack: Factory installed emergency power pack includes charger and inverter concealed in fixture channel. Upon loss of AC power, operates one lamp at reduced light. Suffix: EM. Stem and Canopy Sets: Suspends fixture 6", 12", 18" or 24" from surface. Catalog Number: ASC6 CSP (6") ASC12 CSP (12") ASC18 CSP (18") ASC24 CSP (24") Finish: Chassis exterior–post painted white baked acrylic enamel. End Caps and Cover–Post painted baked white enamel. Phosphate undercoating. Refractor: Low brightness linear prismatic lens, 50% DR (impact resistant) and 50% standard acrylic, 1/8" thickness, withstands 70 ft lbs impact. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc listed. Specifications Materials: Chassis parts are die-formed 20 gauge cold rolled steel. Refractor–one-piece 50% DR virgin acrylic. End Caps–18 gauge cold rolled steel. Job Inform ation T ype: Lightolier a Genlyte Thomas Company www.lightolier.com Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2003 Lightolier Section 6A/Folio P10-62