Download Lightolier Guardsman Vandal Resistant GSW SERIES User's Manual

Transcript
Guardsman Vandal Resistant
Page 1 of 2
GSW SERIES
Ceiling or Wall Mounted Fluorescent
6" Width, 3-7/8" Deep, 24" or 48" Nominal Length, 1 or 2 Lamp T8
Features
• Excellent for locations where vandal resistance is required, areas
such as hallways, stairwells, locker rooms, parking garages and
psychiatric hospitals.
• For ceiling or wall mounted applications.
• Can be vertically or horizontally mounted on wall.
• 20 gauge cold rolled steel, post painted, baked white enamel
housing.
• 18 gauge cold rolled steel post painted baked white enamel end
caps, standard.
• Linear prismatic lens 50% DR (impact resistant) and 50% standard
acrylic with nominal thickness of 1/8", withstands 70 ft lbs impact
without breaking.
• Tamper resistant holt head screws secure ends to housing.
• Only 3-7/8" deep, meets American with Disabilities Act for wall
mounted fixtures.
• Nominal 2' and 4' lengths.
• 73.9% efficient (T8 lamps).
Dimensions
7/8" dia. K.O. (2)
6"
(152mm)
9/32" hole (2)
4" (102mm)
6" (152mm)
3-7/8"
(98mm)
23-15/16"
(608mm)
9/32" hole (2)
7/8" dia. K.O. (3)
1-7/8" dia. K.O.
End Cap
4"
(102mm)
6"
(152mm)
Threaded
Nipple
End Cap
Nut
Nut
24"
(610mm)
48"
(1219mm)
Nut
Required to
space fixtures
apart so ends
can be
removed or
installed.
For Continuous Row Mounting
Job Information
T ype:
Job Name:
C at. N o.
:
Lamp(s):
V olts/Ballast:
9/03
Lightolier a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
Copyright 2003 Lightolier
Section 6A/Folio P10-62
GSW SERIES
Guardsman Vandal Resistant
Ceiling or Wall Mounted Fluorescent
6" Width, 3-7/8" Deep, 24" or 48" Nominal Length, 1 or 2 Lamp T8
Photometry
LER = FP - 62.9
IW - 59.1
BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens = $4.06
Model No. GSW4232120SO
coefficients of utilization — zonal cavity method
RF
20
RC
80
RW
70
50
30
1
81
76
73
2
73
66
61
3
66
58
51
4
61
51
44
5
56
46
39
6
51
41
34
7
48
37
30
8
44
34
27
9
41
31
25
10
39
29
23
visual comfort probability
room size
ceiling height
W
L
8.5
10.0
13.0
20
20
40
47
58
20
30
35
40
46
20
40
33
36
41
20
60
32
35
38
30
20
38
45
55
30
30
32
37
43
30
40
30
33
38
30
60
29
32
34
30
80
29
31
33
40
20
38
45
53
40
30
31
36
42
40
40
29
32
36
40
60
27
30
32
40
80
27
30
31
40
100
27
30
31
60
30
31
36
41
60
40
28
31
35
60
60
26
29
31
60
80
25
28
29
60
100
25
27
29
100
40
29
31
34
100
60
25
28
30
100
80
24
26
28
100
100
23
26
27
room cavity ratio
G97001
GSW4232120SO
luminaries lengthwise
ADVANCE RIC2S32TP SOLID STATE
OCTRON BALLAST
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
20
50
30
65
54
46
40
35
31
28
25
23
21
50
67
58
51
46
41
37
33
31
28
26
16.0
69
56
47
42
66
52
43
39
37
64
51
42
37
35
34
49
41
36
33
32
40
34
32
30
10
62
51
42
36
31
27
24
21
19
17
luminaries crosswise
Page 1 of 2
50
62
54
47
42
38
34
31
29
26
24
8.5
30
20
15
11
32
22
16
12
10
34
24
18
13
10
9
25
19
14
11
9
23
16
13
11
ceiling height
10.0
13.0
39
53
27
35
20
26
15
19
40
51
27
35
20
26
15
19
12
15
42
52
29
36
22
26
16
19
13
15
11
13
31
37
23
27
17
20
14
16
11
13
27
30
20
22
16
18
13
15
20
30
30
60
51
43
38
33
29
26
24
22
20
10
58
48
40
34
29
26
23
20
18
17
16.0
66
48
35
25
64
46
33
25
20
63
46
33
25
20
16
47
34
25
20
17
37
27
22
18
Ordering Information
Explanation of Catalog Number. Example: GSW4232120SOEM
GSW
GSW:
Guardsman
Surface/Wall
Vandal Resistant
Fluorescent
Fixture
Length:
2 = 24"
4 = 48"
Lamp Quantity:
1 or 2 Lamps
Lamp:
(By Others)
17 = T8 2' Length
32 = T8 4' Length
Voltage:
120 or 277
Ballast Type:
Options:
< 20THD < 10THD Add appropriate
suffix
to catalog
1-2 Lamp Elec. T8 SO*
HI*
no, ie: (EM)
0° Starting T8
SD*
–
LOL Dimming T8
PS*
–
*Instant Start Standard
Other dimming options, consult factory.
Options & Accessories
Specifications (continued)
In-Line Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture
standard. Suffix: R. One per ballast. Suffix: B.
Emergency Power Pack: Factory installed emergency power pack includes
charger and inverter concealed in fixture channel. Upon loss of AC power, operates one lamp at reduced light. Suffix: EM.
Stem and Canopy Sets: Suspends fixture 6", 12", 18" or 24" from surface.
Catalog Number: ASC6 CSP (6")
ASC12 CSP (12")
ASC18 CSP (18")
ASC24 CSP (24")
Finish: Chassis exterior–post painted white baked acrylic enamel. End Caps
and Cover–Post painted baked white enamel. Phosphate undercoating.
Refractor: Low brightness linear prismatic lens, 50% DR (impact resistant) and
50% standard acrylic, 1/8" thickness, withstands 70 ft lbs impact.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc listed.
Specifications
Materials: Chassis parts are die-formed 20 gauge cold rolled steel.
Refractor–one-piece 50% DR virgin acrylic. End Caps–18 gauge cold rolled
steel.
Job Inform ation
T ype:
Lightolier a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
Copyright 2003 Lightolier
Section 6A/Folio P10-62