Download Lightolier C12E28FL-PL User's Manual
Transcript
C12E28FL-PL Calculite® HID Lensed Downlight Page 1 of 3 12" Aperture, ED28 (Enclosed), Metal Halide, Prismatic or Fresnel Lens 10 4 8 1 5 2 3 7 9 6 11 20" (508 mm) to 30" (762 mm) 10-3/4" (273 mm) 16-3/8" (416 mm) 13" (330 mm) 23-3/4" (603 mm) 320-400W 21-1/4" (540 mm) 175-250W 11" (280 mm) 13-3/4" (349 mm) Vertical Adjustment: 5/8" (16 mm 2 7/8" (73 m Top View Ceiling Cutout: 12 9/16” (256 mm) Dia. Reflector Trim C12E28PLWHW Prismatic Lens, White Step Baffle. C12E28FLWHW Fresnel Lens, White Step Baffle. 2" (50 mm) max. Ceiling Thickness 12" (305 mm) Dia. 13-1/4" (337 mm) Dia. Frame-In Kit Lamp (Enclosed, Coated) C1217MHPU C1225MHPU C1232MHPU C1240MHPU C1217MHU C1225MHU C1240MHU 175W 250W 320W 400W 175W 250W 400W Features 1. Reflector: Specular anodized aluminum, 16 ga. Removable from inside fixture for access to splices and ballast. 2. Lens: Prismatic (C12E28PLWHW) or Fresnel (C12E28FLWHW) lens. Regressed 2 1/4" from ceiling line. 3. Die-Cast Baffle: Painted white, deep conical step baffle for low brightness, supports lens. Small Allen-head set screw provides secure attachment for use where vandal resistant luminaires are required. 4. Torsiontite Springs: Permit removal of lens assembly without tools. 5. Socket Cup: Heat dissipating die-cast aluminum with medium base pulse rated porcelain socket with nickel plated screw shell. Positive locking attachment, without tools, to reflector assures proper optical alignment of lamp. 6. Mounting Frame: 0.048" (18-ga.) galvanized steel, includes pre-installed mounting bars. 7. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures. 8. Vertical Adjustment Mechanism: accommodates mounting to virtually any ceiling system using mounting bars (provided, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be preset prior to installation. 9. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to 30" long; lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel/wood joists without accessories. 10. Ballast: Dual voltage (120V/277V) magnetic. Assembly is accessible from below without tools for inspection and replacement. 11. Junction Box: 0.048" (18ga.) galvanized steel. UL listed for maximum of (8) No. 12 AWG, 90°C through branch circuit conductors; allows inspection from below 12. Thermal Protector: (not shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire. Magnetic, 120V/277V Pulse Start Magnetic, 120V/277V Pulse Start Magnetic, 120V/277V Pulse Start Magnetic, 120V/277V Pulse Start Magnetic, 120V/277V Magnetic, 120V/277V Magnetic, 120V/277V ED28, BT28 PS MH ED28, BT28 PS MH ED28, BT28 PS MH ED28, BT28 PS MH ED28, BT28 MH ED28, BT28 MH ED28, BT28 MH Electrical (Cont.) Ballast 175W PS MH 250W PS MH 320W PS MH 400W PS MH 175W MH 250W MH 400W MH ANSI Code M137 M138 M132 M135 M57 M58 M59 Voltage 120/277 120/277 120/277 120/277 120/277 120/277 120/277 Max. Amps 2.20/0.90 2.80/1.20 3.40/1.50 4.10/1.80 2.00/0.90 2.60/1.10 3.90/1.70 Input Watts 205 290 370 465 205 290 460 Options and Accessories Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet ”A“. Emergency: Add suffix E to Reflector Trim and Frame-In Kit. See Spec. Sheet “E”. Slope Ceiling Adapters: See Specification Sheet SCA. Fuse (magnetic ballast): Add suffix F1 or F2 to Frame in Kit (F1=120V, F2=277V). Chicago Plenum: Consult Factory. Labels UL (Suitable for Wet Locations), CSA (magnetic ballast only), I.B.E.W. For 320W/400W, install fixtures with minimum spacing: 4 feet from center-to-center of adjacent luminaries; 3 inch from top of luminaire to overhead building member; 2 feet from luminaire center to side building member. Job Information Type: Job Name: Cat. No.: Lamp(s): Notes: Electrical Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, CWA or Super CWA (pulse start) circuit type, high power factor, sound rating “B” (175W and 250W PS)/sound rating “C” (others), -20°F minimum starting Temperature, Type 1 Outdoor rating. Lightolier a Genlyte Thomas Company www.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504 C12E28FL-PL Calculite® HID Lensed Downlight Page 2 of 3 12" Aperture, ED28 (Enclosed), Metal Halide Prismatic or Fresnel Lens FRESNEL LENS/ WHITE BAFFLE - 175W ED28 G.E. METAL HALIDE COATED LAMP. LUMEN RATING = 12900 LMS., ADVANCE BALLAST ANGLE 0 0 5 10 15 60° 20 25 30 35 40 45 50 55 60 65 70 75 80 85 30° 90 1,500 3,000 4,500 6,000 ** EFFICIENCY = 48.8% ** SC = .9 MEAN CP 8996 5781 5575 5247 4882 4348 3584 2713 1883 1250 859 608 448 341 259 201 142 47 14 0 LUMENS 529 1372 1647 1214 692 414 263 141 20 LUMINANCE SUMMARY - CD. / SQ. M. ANGLE MEAN CD/SQ M 45 601630 CEILING 55 387161 WALL 65 303788 RCR 75 271565 85 79179 0 1 ZONAL LUMENS AND PERCENTAGES 2 ZONE LUMENS % LAMP %LUMINAIRE 3 0-30 3547 27.5 56.38 4 0-40 4761 36.91 75.68 5 0-60 5867 45.49 93.26 0-90 6292 48.78 100 6 40-90 1530 11.86 24.32 7 60-90 424 3.29 6.74 8 90-180 0 0 0 9 0-180 6292 48.78 100 10 Coefficients of Utilization 80% 70 50 30 70% 10 50 10 50% 50 10 30% 50 10 0 Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% .58 .55 .52 .49 .47 .44 .42 .40 .38 .36 .34 .58 .54 .50 .46 .43 .40 .37 .35 .33 .31 .29 .58 .52 .48 .43 .40 .37 .34 .32 .30 .28 .26 .58 .51 .46 .41 .38 .35 .32 .30 .28 .26 .24 .57 .53 .49 .45 .42 .39 .37 .35 .32 .30 .29 .57 .50 .45 .41 .38 .35 .32 .30 .27 .26 .24 .54 .50 .47 .44 .41 .39 .36 .34 .32 .30 .28 .54 .49 .44 .40 .37 .34 .32 .29 .27 .25 .24 .52 .49 .46 .43 .40 .38 .36 .33 .31 .30 .28 .52 .47 .43 .40 .37 .34 .32 .29 .27 .25 .24 .49 .45 .41 .38 .36 .33 .31 .28 .26 .25 .23 LUMINAIRE INPUT WATTS = 205 CERTIFIED TEST REPORT NO. 2554FR, DATE: MAR 21, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE** FRESNEL LENS/ WHITE BAFFLE- 250W ED28 PHILIPS METAL HALIDE COATED LAMP. LUMEN RATING = 19475 LMS., UNIVERSAL BALLAST ANGLE 0 5 10 15 20 60° 25 30 35 40 45 50 55 60 65 70 75 80 85 90 30° 2,000 4,000 6,000 8,000 MEAN CP 7764 7645 7434 7120 6350 5182 3901 2741 1841 1276 908 668 506 385 299 210 71 21 0 LUMENS 728 1986 2386 1763 1026 617 391 209 31 LUMINANCE SUMMARY - CD. / SQ. M. ANGLE MEAN CD/SQ M 45 893382 CEILING 55 576797 WALL 65 450887 RCR 75 400904 0 85 120690 1 2 ZONAL LUMENS AND PERCENTAGES 3 ZONE LUMENS % LAMP %LUMINAIRE 0-30 5099 26.18 55.82 4 0-40 6861 35.23 75.11 5 0-60 8504 43.67 93.1 6 0-90 9135 46.91 100 40-90 2273 11.67 24.89 7 60-90 630 3.24 6.9 8 90-180 0 0 0 9 0-180 9135 46.91 100 10 Coefficients of Utilization 80% 70 50 30 70% 10 50 10 50% 50 10 30% 50 10 Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% .56 .56 .56 .56 .55 .55 .52 .52 .50 .50 .53 .51 .50 .49 .51 .48 .49 .47 .47 .45 .50 .48 .46 .44 .47 .43 .45 .42 .44 .41 .47 .44 .42 .40 .43 .39 .42 .39 .41 .38 .45 .41 .38 .36 .41 .36 .40 .36 .39 .35 .42 .38 .35 .33 .38 .33 .37 .33 .36 .32 .40 .36 .33 .31 .35 .31 .35 .30 .34 .30 .38 .33 .30 .28 .33 .28 .32 .28 .32 .28 .36 .31 .28 .26 .31 .26 .30 .26 .30 .26 .34 .29 .26 .24 .29 .24 .29 .24 .28 .24 .32 .28 .25 .23 .27 .23 .27 .23 .27 .23 0 .47 .43 .40 .37 .34 .31 .29 .27 .25 .23 .22 LUMINAIRE INPUT WATTS = 290 ** EFFICIENCY = 46.9% ** SC = .9 CERTIFIED TEST REPORT NO. 2557FR, DATE: MAR 21, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE** FRESNEL LENS/ WHITE BAFFLE - 320W ED28 PHILIPS METAL HALIDE COATED LAMP. LUMEN RATING = 30100 LMS., ADVANCE BALLAST ANGLE 0 5 10 15 20 60° 25 30 35 40 45 50 55 60 65 70 75 80 85 90 30° 2,750 5,500 8,250 11,000 ** EFFICIENCY = 42.6% ** SC = .9 MEAN CP 10463 10298 10043 9696 8873 7298 5523 3882 2614 1810 1287 953 724 557 433 307 128 31 1 LUMENS 981 2715 3355 2497 1456 878 564 311 52 LUMINANCE SUMMARY - CD. / SQ. M. ANGLE MEAN CD/SQ M 45 1267525 CEILING 55 822644 WALL 65 652886 RCR 75 588204 85 177806 0 1 ZONAL LUMENS AND PERCENTAGES 2 ZONE LUMENS % LAMP %LUMINAIRE 3 0-30 7050 23.42 55.05 4 0-40 9547 31.72 74.54 5 0-60 11882 39.47 92.77 0-90 12808 42.55 100 6 40-90 3260 10.83 25.46 7 60-90 926 3.08 7.23 8 90-180 0 0 0 9 0-180 12808 42.55 100 10 Coefficients of Utilization 80% 70% 50% 30% 70 50 30 10 50 10 50 10 50 10 0 Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% .51 .48 .45 .43 .41 .38 .36 .34 .33 .31 .29 .51 .47 .43 .40 .37 .35 .32 .30 .28 .26 .25 .51 .45 .41 .38 .35 .32 .30 .27 .25 .24 .22 .51 .44 .40 .36 .33 .30 .28 .26 .24 .22 .20 .49 .46 .42 .39 .37 .34 .32 .30 .28 .26 .25 .49 .44 .39 .35 .32 .30 .28 .25 .24 .22 .20 .47 .44 .41 .38 .36 .33 .31 .29 .27 .26 .24 .47 .42 .38 .35 .32 .30 .27 .25 .23 .22 .20 .45 .42 .40 .37 .35 .33 .31 .29 .27 .25 .24 .45 .41 .37 .34 .32 .29 .27 .25 .23 .22 .20 .43 .39 .36 .33 .31 .28 .26 .24 .23 .21 .19 LUMINAIRE INPUT WATTS = 370 CERTIFIED TEST REPORT NO. 2558FR, DATE: MAR 21, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE** FRESNEL LENS/ WHITE BAFFLE - 400W ED28 G.E. METAL HALIDE COATED LAMP. LUMEN RATING = 35000 LMS. ADVANCE BALLAST ANGLE 0 5 10 15 20 60° 25 30 35 40 45 50 55 60 65 70 75 80 85 90 30° 3,750 7,500 11,250 15,000 ** EFFICIENCY = 49.2% ** SC= .9 MEAN CP 15666 15225 14335 13279 11715 9625 7341 5183 3500 2420 1711 1256 950 719 559 396 138 41 0 LUMENS 1443 3728 4433 3331 1946 1160 731 394 60 LUMINANCE SUMMARY - CD. / SQ. M. ANGLE MEAN CD/SQ M CEILING 45 1695165 55 1084702 WALL 65 842680 RCR 75 758600 0 85 235481 1 2 ZONAL LUMENS AND PERCENTAGES 3 ZONE LUMENS % LAMP %LUMINAIRE 0-30 9603 27.44 55.75 4 0-40 12933 36.95 75.08 5 0-60 16040 45.83 93.12 6 0-90 17225 49.22 100 7 40-90 4291 12.26 24.92 60-90 1185 3.39 6.88 8 90-180 0 0 0 9 0-180 17225 49.22 100 10 CERTIFIED TEST REPORT NO. 2561FR, DATE: MAR 22, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE** Coefficients of Utilization 80% 70% 50% 30% 70 50 30 10 50 10 50 10 50 10 0 Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% .59 .56 .52 .50 .47 .45 .42 .40 .38 .36 .34 .59 .54 .50 .46 .43 .40 .38 .35 .33 .31 .29 .59 .53 .48 .44 .40 .37 .35 .32 .30 .28 .26 .59 .51 .46 .42 .38 .35 .32 .30 .28 .26 .24 .57 .53 .49 .46 .43 .40 .37 .35 .32 .31 .29 .57 .51 .45 .41 .38 .35 .32 .30 .28 .26 .24 .55 .51 .47 .44 .42 .39 .36 .34 .32 .30 .28 .55 .49 .44 .41 .37 .34 .32 .30 .27 .25 .24 .52 .49 .46 .43 .41 .38 .36 .33 .31 .30 .28 .52 .48 .44 .40 .37 .34 .32 .29 .27 .25 .24 .49 .45 .42 .39 .36 .33 .31 .28 .26 .25 .23 LUMINAIRE INPUT WATTS = 460 Job Information Type: Lightolier a Genlyte Thomas Company www.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504 Calculite® HID Lensed Downlight Page 3 of 3 C12E28FL-PL 12" Aperture, ED28 (Enclosed), Metal Halide or Prismatic Fresnel Lens PRISMATIC LENS- 175W ED28 G.E. METAL HALIDE COATED LAMP. LUMEN RATING = 12900 LMS., ADVANCE BALLAST ANGLE 0 5 10 15 20 60° 25 30 35 40 45 50 55 60 65 70 75 80 85 90 30° 1,750 3,500 5,520 7,000 ** EFFICIENCY = 47.2% ** SC = .8 MEAN CP 6780 6578 6049 5291 4420 3463 2522 1734 1149 765 522 352 248 195 138 79 36 11 0 LUMENS 620 1492 1605 1121 620 331 192 88 16 LUMINANCE SUMMARY - CD. / SQ. M. ANGLE MEAN CD/SQ M 45 536031 CEILING 55 303825 WALL 65 227960 RCR 75 152040 85 61798 0 1 ZONAL LUMENS AND PERCENTAGES 2 ZONE LUMENS % LAMP %LUMINAIRE 3 0-30 3716 28.81 61.08 4 0-40 4837 37.5 79.51 5 0-60 5788 44.87 95.13 0-90 6084 47.17 100 6 40-90 1246 9.66 20.49 7 60-90 296 2.3 4.87 8 90-180 0 0 0 9 0-180 6084 47.17 100 10 Coefficients of Utilization 80% 70 50 30 70% 10 50 10 50% 50 10 30% 50 10 0 Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% .56 .53 .51 .48 .46 .44 .42 .39 .38 .36 .34 .56 .52 .49 .45 .43 .40 .38 .35 .33 .31 .30 .56 .51 .47 .43 .40 .37 .35 .32 .30 .29 .27 .56 .50 .45 .41 .38 .35 .33 .31 .29 .27 .25 .55 .51 .48 .45 .42 .39 .37 .35 .33 .31 .29 .55 .49 .45 .41 .38 .35 .33 .30 .28 .27 .25 .52 .49 .46 .43 .41 .39 .36 .34 .32 .31 .29 .52 .48 .44 .40 .37 .35 .32 .30 .28 .26 .25 .50 .47 .45 .42 .40 .38 .36 .34 .32 .30 .29 .50 .46 .43 .40 .37 .34 .32 .30 .28 .26 .25 .47 .44 .41 .38 .36 .33 .31 .29 .27 .26 .24 LUMINAIRE INPUT WATTS = 205 CERTIFIED TEST REPORT NO. 2555FR, DATE: MAR 21, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE** PRISMATIC LENS- 250W ED28 PHILIPS METAL HALIDE COATED LAMP. LUMEN RATING = 19475 LMS., UNIVERSAL BALLAST ANGLE 0 5 10 15 20 60° 25 30 35 40 45 50 55 60 65 70 75 80 85 90 30° 2,125 4,250 6,375 8,500 ** EFFICIENCY = 47.4% ** SC = .9 MEAN CP 8614 8519 8224 7721 6846 5413 3961 2739 1818 1217 830 560 398 308 220 129 60 20 0 LUMENS 808 2162 2503 1768 984 526 306 142 27 LUMINANCE SUMMARY - CD. / SQ. M. ANGLE MEAN CD/SQ M 45 852701 CEILING 55 483130 WALL 65 361094 RCR 75 246762 85 111021 0 1 ZONAL LUMENS AND PERCENTAGES 2 ZONE LUMENS % LAMP %LUMINAIRE 3 0-30 5473 28.11 59.32 4 0-40 7241 37.19 78.48 5 0-60 8752 44.94 94.85 0-90 9227 47.38 100 6 40-90 1986 10.2 21.52 7 60-90 475 2.44 5.15 8 90-180 0 0 0 9 0-180 9227 47.38 100 10 Coefficients of Utilization 80% 70 50 30 70% 10 50 10 50% 50 10 30% 50 10 0 Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% .56 .54 .51 .48 .46 .44 .41 .39 .37 .35 .34 .56 .52 .49 .45 .42 .40 .37 .35 .33 .31 .29 .56 .51 .47 .43 .40 .37 .34 .32 .30 .28 .26 .56 .50 .45 .41 .38 .35 .32 .30 .28 .26 .24 .55 .51 .48 .45 .42 .39 .37 .35 .32 .30 .29 .55 .49 .44 .41 .37 .35 .32 .30 .28 .26 .24 .53 .49 .46 .43 .41 .38 .36 .34 .32 .30 .28 .53 .48 .43 .40 .37 .34 .32 .30 .28 .26 .24 .50 .47 .45 .42 .40 .37 .35 .33 .31 .30 .28 .50 .46 .43 .39 .37 .34 .32 .29 .28 .26 .24 .47 .44 .41 .38 .35 .33 .31 .29 .27 .25 .23 LUMINAIRE INPUT WATTS = 290 CERTIFIED TEST REPORT NO. 2556FR, DATE: MAR 21, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE** PRISMATIC LENS - 320W ED28 PHILIPS METAL HALIDE COATED LAMP. LUMEN RATING = 30100 LMS., ADVANCE BALLAST ANGLE 0 5 10 15 20 60° 25 30 35 40 45 50 55 60 65 70 75 80 85 90 30° 3,750 7,500 11,250 15,000 ** EFFICIENCY = 44.5% SC = .8 MEAN CP 14920 14486 13317 11664 9775 7649 5553 3810 2513 1681 1138 771 554 426 306 174 78 18 0 LUMENS 1365 3290 3544 2463 1358 725 425 193 31 LUMINANCE SUMMARY - CD. / SQ. M. ANGLE MEAN CD/SQ M 45 1177083 CEILING 55 665377 WALL 65 499041 RCR 75 332156 85 103373 0 1 ZONAL LUMENS AND PERCENTAGES 2 ZONE LUMENS % LAMP %LUMINAIRE 3 0-30 8198 27.24 61.21 4 0-40 10662 35.42 79.6 5 0-60 12744 42.34 95.15 0-90 13394 44.5 100 6 40-90 2732 9.08 20.4 7 60-90 649 2.16 4.85 8 90-180 0 0 0 9 0-180 13394 44.5 100 10 Coefficients of Utilization 80% 70 50 30 70% 10 50 10 50% 50 10 30% 50 10 0 Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% .53 .50 .48 .46 .43 .41 .39 .37 .36 .34 .32 .53 .49 .46 .43 .40 .38 .35 .33 .31 .30 .28 .53 .48 .44 .41 .38 .35 .33 .31 .29 .27 .25 .53 .47 .42 .39 .36 .33 .31 .29 .27 .25 .24 .52 .48 .45 .42 .40 .37 .35 .33 .31 .29 .28 .52 .46 .42 .39 .36 .33 .31 .29 .27 .25 .24 .49 .46 .44 .41 .39 .36 .34 .32 .31 .29 .27 .49 .45 .41 .38 .35 .33 .31 .29 .27 .25 .23 .47 .45 .42 .40 .38 .36 .34 .32 .30 .28 .27 .47 .43 .40 .37 .35 .32 .30 .28 .27 .25 .23 .44 .41 .39 .36 .34 .31 .30 .28 .26 .24 .23 LUMINAIRE INPUT WATTS = 370 **CERTIFIED TEST REPORT NO. 2559FR, DATE: MAR 21, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE** PRISMATIC LENS - 400W ED28 G.E. METAL HALIDE COATED LAMP. LUMEN RATING = 35000 LMS. ADVANCE BALLAST ANGLE 0 5 10 15 20 60° 25 30 35 40 45 50 55 60 65 70 75 80 85 90 30° 5,000 10,000 15,000 20,000 ** EFFICIENCY = 50.4% ** SC = .8 MEAN CP 19667 19072 17547 15345 12839 10059 7317 5028 3325 2217 1504 1006 712 557 395 226 103 29 0 LUMENS 1798 4328 4660 3251 1794 948 551 251 44 LUMINANCE SUMMARY - CD. / SQ. M. ANGLE MEAN CD/SQ M 45 1553151 CEILING 55 869063 WALL 65 652850 RCR 75 432092 85 166222 0 1 ZONAL LUMENS AND PERCENTAGES 2 ZONE LUMENS % LAMP %LUMINAIRE 3 0-30 10786 30.82 61.2 4 0-40 14037 40.11 79.64 5 0-60 16779 47.94 95.2 0-90 17625 50.36 100 6 40-90 3588 10.25 20.36 7 60-90 846 2.42 4.8 8 90-180 0 0 0 9 0-180 17625 50.36 100 10 CERTIFIED TEST REPORT NO. 2560FR, DATE: MAR 22, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE** Coefficients of Utilization 80% 70 50 30 70% 10 50 10 50% 50 10 30% 50 10 0 Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% .60 .57 .54 .52 .49 .47 .45 .42 .40 .38 .36 .60 .56 .52 .48 .45 .43 .40 .38 .35 .33 .32 .60 .54 .50 .46 .43 .40 .37 .35 .33 .30 .29 .60 .53 .48 .44 .41 .38 .35 .33 .30 .28 .27 .59 .55 .51 .48 .45 .42 .40 .37 .35 .33 .31 .59 .52 .48 .44 .40 .37 .35 .32 .30 .28 .27 .56 .52 .49 .46 .44 .41 .39 .37 .35 .33 .31 .56 .51 .46 .43 .40 .37 .35 .32 .30 .28 .27 .54 .51 .48 .45 .43 .40 .38 .36 .34 .32 .31 .54 .49 .46 .42 .39 .37 .34 .32 .30 .28 .26 .50 .47 .44 .41 .38 .36 .33 .31 .29 .27 .26 LUMINAIRE INPUT WATTS = 460 Job Information Type: Lightolier a Genlyte Thomas Company www.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504