Installation b. Non-Graco Isolated Enclosure: Connect hose as instructed in the isolation system manual, and comply with the requirements in the Warning below. For Shielded Hose Systems: Conductive hose layer (C) must be grounded through its connection to the isolation system’s grounded enclosure (L) or grounded fence. To maintain grounding continuity, the conductive hose layer (C) must be engaged in the ferrule when the strain relief nut is tightened. Failure to properly install the hose in the strain relief could result in an electric shock. 3A2496D Figure 18 Shielded Fluid Hose Connection at Non-Graco Isolation Enclosure c. Connect the end of the tube (T) to the pump fluid outlet fitting (Z). NOTE: The Graco warranty and approvals are void if the electrostatic spray gun is connected to a non-Graco voltage isolation system or if the gun is operated above 60 kV. 21