Transcript
Setup Mode Configure Screen 3 Configure Screen 4 OR FIG. 30. Configure Screen 4 Dose Size Select the total dose size (cc) from the pulldown menu: 100, 50, 25, or 10. The DD selection (dynamic dosing) is not used with the ProControl 1KS. Dose Time Alarm Enter the dose time (1 to 99 seconds). This is the amount of time allowed for a dose to occur before a dose time alarm occurs. FIG. 29. Configure Screen 3 Number of Guns Run Mode Select the Run mode application from the pulldown menu: Automatic (default), Semi-Automatic (uses a manual spray gun), or Manual. Dump Valve A Enter the number of spray guns (1 or 2). NOTE: Only 1 gun is used in automatic mode. Gun Flush Box (manual or semi-automatic mode) Enter the number of gun flush boxes (Off, 1, or 2). This field only appears if the system includes an optional dump valve A. If dump valve A is included, set to On. Dump Valve B This field only appears if the catalyst change option is detected from the cc board, meaning that dump valve B is present. On is the only setting. 3rd Flush Valve Off is default. If optional 3rd flush valve is used, set to On. 30 3A1080C