Download Graco 3A0239F User's Manual

Transcript
Instructions - Parts
Power Distribution
Module
3A0239F
EN
For use with HFR, VRM, and VPM plural-component proportioners. For professional use
only.
Not approved for use in European explosive atmosphere locations.
Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
See page 3 for model information.
US Patent Pending
r_24C860_3A0239_1a
Contents
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Replace Power Supply . . . . . . . . . . . . . . . . . . . . 6
Replace Circuit Breaker . . . . . . . . . . . . . . . . . . . 6
Electrical Schematics . . . . . . . . . . . . . . . . . . . . . . . 7
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
HFR Power Distribution Modules . . . . . . . . . . . 20
VRM Power Distribution Modules . . . . . . . . . . . 23
VPM Power Distribution Modules . . . . . . . . . . . 26
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 30
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . 30
2
3A0239F
Models
Models
Description
Maximum
Amperes
Description
HFR Power Distribution Modules
230V, 1 Phase, Basic
55 A
230V, 1 Phase, Fully Loaded
116 A
230V, 3 Phase, Basic
29 A
230V, 3 Phase, Fully Loaded
73 A
400V, 3 Phase, Basic 
55 A
400V, 3 Phase, Fully Loaded 
63 A
200-240VAC, 1 phase, 50/60 Hz
2 wire and PE
200-240VAC, 3 phase Δ, 50/60 Hz
3 wire and PE
380-415VAC, 3 phase Y, 50/60 Hz
3 wire, neutral, and PE


VRM Power Distribution Modules
230V, 3 Phase, Basic
60 A
230V, 3 Phase, Fully Loaded
105 A
400V, 3 Phase, Basic 
55 A
400V, 3 Phase, Fully Loaded 
75 A
200-240VAC, 3 phase Δ, 50/60 Hz
3 wire and PE
380-415VAC, 3 phase Y, 50/60 Hz
3 wire, neutral, and PE


VPM Power Distribution Modules
230V, 3 Phase
75 A
200-240VAC, 3 phase Δ, 50/60 Hz
3 wire and PE
400V, 3 Phase 
55 A
400V, 3 Phase 
55 A
380-415VAC, 3 phase Y, 50/60 Hz
3 wire, neutral, and PE

 The Residual Current Device (RCD) must be rated at 300 mA if it is installed.
Basic modules provide power to the control dispense system only.
Fully loaded modules provide power to the control dispense system, four heat zones, and two feed tanks.
 See 400 V Power Requirements.
400 V Power Requirements
•
400 V systems are intended for International voltage
requirements. Not for voltage requirements in North
America.
•
If a 400 volt configuration is operated in North America, a special transformer rated for 400 V (“Y” configuration (4 wire)) may be required.
•
North America mostly employs a 3 wire or Delta
configuration. The two configurations are not interchangeable.
3A0239F
3
Warnings
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back
to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where
applicable.
WARNING
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause
electric shock.
• Turn off and disconnect power at main switch before disconnecting any cables and before servicing
equipment.
• Connect only to grounded power source.
• All electrical wiring must be done by a qualified electrician and comply with all local codes and
regulations.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
• Do not leave the work area while equipment is energized or under pressure. Turn off all equipment
and follow the Pressure Relief Procedure in this manual when equipment is not in use.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.
• Do not alter or modify equipment.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
4
3A0239F
Troubleshooting
Troubleshooting
Problem
Cause
Solution
No power received from DC power
supply.
Defective power supply.
Check circuit breaker. Check power
supply. Replace power supply.
No power to MCM, heat zones, or
tanks.
Circuit breaker is tripping.
Check circuit breaker for tripping and
defects. Diagnose cause of circuit
breaker tripping before resetting it.
Replace defective parts if required.
3A0239F
5
Repair
Repair
Replace Power Supply
Replace Circuit Breaker
1. Turn off system power.
1. Turn off system power.
2. Open electrical enclosure door.
2. Open electrical enclosure door.
3. Disconnect power supply (1a) wires from the filter
(1c) and the electrical enclosure connector.
3. Disconnect wire harness from circuit breaker.
4. Remove circuit breaker.
4. Remove nuts and washers that secure power supply
to electrical enclosure.
5. Install new power supply to electrical enclosure.
Secure with nuts and washers.
5. Install new circuit breaker, and connect wire harness.
6. Close electrical enclosure door and turn on system
power.
6. Connect power supply wires to the filter and the
electrical enclosure connector.
Wire Harness
7. Close electrical enclosure door and turn on system
power.
Wire Harness
1c
1a
Connector
r_24C680_3A0239_10a
r_24C686_3A0239_2a
Circuit Breaker
6
3A0239F
Electrical Schematics
Electrical Schematics
230V, 1 Phase, Basic HFR Module Schematic
3A0239F
7
Electrical Schematics
230V, 1 Phase, Loaded HFR Module Schematic
8
3A0239F
Electrical Schematics
230V, 3 Phase, Basic HFR Module Schematic
3A0239F
9
Electrical Schematics
230V, 3 Phase, Basic VRM Module Schematic
10
3A0239F
Electrical Schematics
230V, 3 Phase, Loaded HFR Module Schematic
3A0239F
11
Electrical Schematics
230V, 3 Phase, Loaded VRM Module Schematic
12
3A0239F
Electrical Schematics
400V, 3 Phase, Basic HFR Module Schematic
3A0239F
13
Electrical Schematics
400V, 3 Phase, Basic VRM Module Schematic
14
3A0239F
Electrical Schematics
400V, 3 Phase, Loaded HFR Module Schematic
3A0239F
15
Electrical Schematics
400V, 3 Phase, Loaded VRM Module Schematic
16
3A0239F
Electrical Schematics
230V, 3 Phase, Loaded VPM Module Schematic
3A0239F
GND
1L3
1
HARNESS
1L1
1L2
1L3
PG105
GND
L3
L2
1L1
DISC-1
1
GND
1L1
1080
BLK
1080
1L2
1100
RED
1100
WHT
1120
1L3
1120
CB1
30A
L1
331
L2
PG116
1L2
1L2
1L3
1L3
1160
1160
1180
1180
CB2
20A
1L3
1L3
PRIMARY HT
B VOLUME
HARNESS
1220
1220
1240
1240
1
GND
1L1
1
511
PG121
1L1
MCM
B VOLUME
L3
HARNESS
CB3
15A
TANK
VOLUME
HARNESS
PG133
1L2
1L1
1340
1L2
1360
1340
1360
1340
MISC
B VOLUME
1390 BR
L1/P
1400 BL
L2/N
LINE
1360
755
1360
POWER
FILTER
CB5
5A
1
1340
POWER
SUPPLY
CAN SPLITTER
123466
121808
LOAD
1L1
GND
151 151 151
1L1
1L2
1L3
1L1
1L2
1L3
148
148
148
HARNESS
1L1
1L2
1L3
PG156
GND
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
1L2
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
L1
230V/
3PH/
50-60HZ
1L1
1580
BLK
1580
1L2
1600
RED
1600
WHT
1620
1L3
1620
CB10
30A
L1
469
L2
1L1
1L2
1L2
1660
1660
1680
1680
MCM
A VOLUME
L3
HARNESS
PG166
1L1
2
GND
2
649
PRIMARY HT
A VOLUME
CB9
20A
HARNESS
PG184
1L1
1L1
1L3
1L3
1840
1840
1860
1860
2
824
MISC
A VOLUME
CB6
5A
17
Electrical Schematics
400V, 3 Phase, Loaded, Non-CE, VPM Module Schematic
18
GND
1N
1L3
1
HARNESS
1L1
1N
PG105
GND
N
L3
GND
1L1
1080
BLK
1080
1N
1100
WHT
1100
CB1A
63A
L1
331
L2
PG116
1L2
1L2
1N
1N
1160
1160
1180
1180
CB2
20A
1N
1N
PRIMARY HT
B VOLUME
HARNESS
1220
1220
1240
1240
1
GND
1L2
1
511
PG121
1L2
MCM
B VOLUME
L3
HARNESS
CB3
15A
TANK
B VOLUME
HARNESS
PG133
1L2
1N
1L2
1340
1N
1360
1340
1360
1340
MISC
B VOLUME
1390 BR
L1/P
1400 BL
L2/N
LINE
1
755
1360
POWER
FILTER
CB5
5A
1360
1340
POWER
SUPPLY
CAN SPLITTER
123466
121808
LOAD
L1
1L1
DISC-1
1
GND
151 151 151
1L2
1L3
1N
1L2
1L3
1N
148
148
148
HARNESS
1L3
1N
PG156
GND
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
1L2
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
L2
400V/
3PH/
50-60HZ
1L3
1580
BLK
1580
1N
1600
WHT
1600
CB10A
63A
L1
469
L2
PG166
1N
MCM
A VOLUME
L3
HARNESS
1L2
2
GND
1L2
1660
1660
1N
1680
1680
2
649
PRIMARY HT
A VOLUME
CB9
20A
HARNESS
PG184
1L2
1L2
1N
1N
1840
1840
1860
1860
2
824
MISC
A VOLUME
CB6
5A
3A0239F
Electrical Schematics
400V, 3 Phase, Loaded, CE approved, VPM Module Schematic
3A0239F
GND
1N
HARNESS
POWER
FILTER
1L1
1N
1L1
1081
1N
1101
L2/N
LINE
CB1A
63A
L1/P
BLK
1080
1100
WHT
1100
1L2
1N
1N
L1
331
L2
PG116
1160
1160
1180
1180
CB2
20A
1N
1N
PRIMARY HT
B VOLUME
HARNESS
1220
1220
1240
1240
1
GND
1L2
1
511
PG121
1L2
MCM
B VOLUME
L3
HARNESS
GND
1L2
GND
1080
LOAD
1L3
1
PG105
GND
N
L3
CB3
15A
TANK
B VOLUME
HARNESS
PG133
1N
1340
1N
1360
1340
1340
1360
1340
1400 BL
L2/N
LINE
MISC
B VOLUME
1390 BR
L1/P
1360
1
755
1360
POWER
FILTER
CB5
5A
POWER
SUPPLY
CAN SPLITTER
123466
121808
LOAD
1L2
1L2
GND
151 151 151
1L3
1N
1L2
1L3
1N
148
148
148
HARNESS
POWER
FILTER
1L3
1N
1L3
1581
1N
1601
CB10A
63A
L1/P
L2/N
GND
1L2
1L2
1N
1N
PG156
GND
1L2
2
GND
1580
BLK
1580
1600
WHT
1600
LOAD
L1
1L1
DISC-1
1
LINE
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
1L2
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
L2
400V/
3PH/
50-60HZ
L1
469
L2
MCM
A VOLUME
L3
HARNESS
PG166
1660
1660
1680
1680
2
649
PRIMARY HT
A VOLUME
CB9
20A
HARNESS
PG184
1L2
1L2
1N
1N
1840
1840
1860
1860
2
824
MISC
A VOLUME
CB6
5A
19
Parts
Parts
HFR Power Distribution Modules
400V, 3 Phase, Basic Module Shown
19
56
62
18, 48
56
4
9
5, 6
1
3
14
69
2
8
23
7
21
8
r_24C686_3A0239_2b
3
13
39
12
11
10
35
46
8
46
44
Circuit Breaker Detail for 400V,
3 Phase, Loaded Module
10
7
11
r_24C688_3A0239_4a
39
20
35 36
38
36
35
3A0239F
Parts
1c
24
26
61
26
27
20
1a
27
r_24C680_3A0239_5a
Parts Used on All HFR Modules
Ref.
1
1a
Part
Description
Qty.
--ENCLOSURE
1
24D207 SUPPLY, power; 24 Vdc, 4A,
1
100W, 230 Vac
1b 196548 LABEL, caution
1
(on enclosure door)
1c 123718 FILTER
1
2
--PANEL, electrical
1
3
123396 NUT, flange, serrated; 3/8-16
4
4
117666 TERMINAL, ground
1
5
113783 SCREW, mach, pan hd
1
6
100985 WASHER, lock ext
1
7
16A647 RAIL, din, 17.7 in.
1
9
16A649 HARNESS, ground wire; 8 awg
1
10
123363 BLOCK, terminal, ground, 10mm
4
11
--LABEL, identification
1
12
24D217 HARNESS, wire,16 awg, ferrule
2
13
24D218 HARNESS, wire,16 awg, ferrule,
1
terminal ground
14
24D220 HARNESS, wire,18 awg, ring,
1
terminal, ground
3A0239F
Ref.
24
25
26
27
29
61
69
25
29
r_24C680_3A0239_6a
Part
Description
Qty.
122487 CABLE, CAN, male-female,1.5 m 1
123589 BUSHING, wire protector,
2
snap-in
111800 SCREW, cap, hex head
10
123679 BUSHING, wire protector;
3
1 3/8 OD
123590 PLUG, hole; 2 in. diameter
2
--BRACKET, support, electric
2
--LABEL, identification
1
 Not shown.
--- Not for sale.
 Replacement Danger and Warning labels, tags, and
cards are available at no cost.
21
Parts
Parts that Vary by HFR Module
Use the following table to locate parts that vary by module. See Parts Used on All HFR Modules, page 21, for parts
used on all HFR modules.
Ref.
Description
230V,
1 phase,
basic
230V,
1 phase,
loaded
8
SCREW, machine
103833(4) 103833(4) 103833(4) 103833(4) 103833(8) 103833(8)
18
SWITCH, disconnect
123969
123360
123969
123969
123969
123969
1
19
KNOB, operator disconnect
123967
123362
123967
123967
123967
123967
1
20
HARNESS, wire, MCM; 6/3
24C515
24C515
24C515
24C515
1
HARNESS, wire, MCM; 10/4
230V,
3 phase,
basic
24C516
230V,
3 phase,
loaded
400V,
3 phase,
basic
4000V,
3 phase,
loaded Qty.
24C516
-
1
21
FILTER, 55A, 3P
123785
123785
1
23
HARNESS, wire, 8 awg,
ground
24D216
24D216
1
35
CIRCUIT, breaker, 2P, 5A
36
CIRCUIT, breaker, 2P, 15A
123350
123350
123350
2
38
CIRCUIT, breaker, 2P, 40A
123455
123455
123455
4
39
CIRCUIT, breaker, 2P, 63A
123668
1
40
CIRCUIT, breaker, 3P, 30A
41
BUSS BAR, 3P, 6 PIN, 115A
1
43
BUSS BAR, 3P, 18 PIN, 115A
1
44
BUSS BAR, 2P, 6 PIN, 115A
123310 (1)
45
BUSS BAR, 2P, 12 PIN, 115A
123474
46
CONNECTOR, lug, power,
115A
47
CAP, lug, power
48
SWITCH, disconnect, ph exp
100A
56
HARNESS, wire 6 awg,
14 awg
57
HARNESS, wire 6 awg
58
HARNESS, wire 4 awg,
ferruled
59
HARNESS, wire, plug, tanks
62
HARNESS, wire, 6 awg,
ferruled
72
LATCH, plug, 30A
123296 (1) 123296 (2) 123296 (1) 123296 (2) 123296 (1) 123296 (2)
123668
123668
123668
123302
123302
-
1
123310 (3)
1
123306 (2) 123306 (3) 123306 (3)
123306 (8)
---
1
123968
16A650
123968
16A650
1
2
16A694 (3)
-
24D221 (4)
24D221 (3)
24D221 (6)
-
24C517
24C517
24C517
2
16D536
2
24E823
2
16D536
24E823
24E823
 Not shown.
--- Not for sale.
22
3A0239F
Parts
VRM Power Distribution Modules
400V, 3 Phase, Basic Module Shown
19
57
56
55
18, 48
8, 49, 50 23
4
5, 6
2
56
3
14
69
1
21
23
7
21
8
3
13
12
39
35
11
10
8
9
r_24C687_3A0239_3a
46
Circuit Breaker Detail for 400V,
3 Phase, Loaded Module
46
44
10
7
11
39
3A0239F
35
36
38
36
35
39
r_24C689_3A0239_7a
23
Parts
63, 64, 65
24
26
1c
20
20
1a
27
28
27
26
25
29
Parts Used on All VRM Modules
Ref.
1
1a
Part
Description
Qty.
--ENCLOSURE
1
24D207 SUPPLY, power; 24 Vdc, 4A,
1
100W, 230 Vac
1b 196548 LABEL, caution
1
(on enclosure door)
1c
123718 FILTER
1
2
--PANEL, electrical
1
3
123396 NUT, flange, serrated; 3/8-16
4
4
117666 TERMINAL, ground
1
5
113783 SCREW, mach, pan hd
1
6
100985 WASHER, lock ext
1
7
16A647 RAIL, din, 17.7 in.
1
9
16A649 HARNESS, ground wire; 8 awg
1
10
123363 BLOCK, terminal, ground, 10mm 4
11
--LABEL, identification
1
12
24D217 HARNESS, wire,16 awg, ferrule
2
13
24D218 HARNESS, wire,16 awg, ferrule,
1
terminal ground
14
24D220 HARNESS, wire,18 awg, ring,
1
terminal, ground
24
122487 CABLE, CAN, male-female;
2
1.5 m
25
123589 BUSHING, wire protector,
2
snap-in
24
r_24C683_3A0239_9a
r_24C683_3A0239_8a
Ref.
26
27
28
29
35
63
64
65
66
69
Part
Description
111800 SCREW, cap, hex head
123679 BUSHING, wire protector;
1 3/8 OD
123398 PLUG, hole,1.5 in. diameter
123590 PLUG, hole; 2 in. diameter
123296 CIRCUIT, breaker, 2P, 5A
24C477 BRACE, wireway, divided
24C478 COVER, wireway
102040 NUT, lock, hex
124128 BUSHING, wire protector
--LABEL, identification
Qty.
10
3
2
2
2
1
1
2
1
1
 Not shown.
--- Not for sale.
 Replacement Danger and Warning labels, tags, and
cards are available at no cost.
3A0239F
Parts
Parts that Vary by VRM Module
Use the following table to locate parts that vary by module. See Parts Used on All VRM Modules, page 24, for parts
used on all VRM modules.
230V,3 phase,
basic
230V, 3 phase,
loaded
400V, 3 phase,
basic
400V, 3 phase,
loaded
103833 (4)
103833 (4)
103833 (14)
103833 (12)
-
SWITCH, disconnect
123969
123360
123969
123969
1
19
KNOB, operator
disconnect
123967
123362
123967
123967
1
20
HARNESS, wire, MCM; 6/3
24C515
24C515
2
Ref
Description
8
SCREW, machine
18
HARNESS, wire, MCM; 10/4
24C516
24C516
Qty
2
21
FILTER, 55A, 3P
123785
123785
2
23
HARNESS, wire, 8 awg,
ground
24D216
24D216
2
36
CIRCUIT, breaker, 2P, 15A
123350
123350
2
38
CIRCUIT, breaker, 2P, 40A
123455
123455
4
39
CIRCUIT, breaker, 2P, 63A
123668
2
40
CIRCUIT, breaker, 3P, 30A
123302
123302
2
42
BUSS BAR, 2P, 6 PIN, 115A
123308
123308
1
43
BUSS BAR, 3P, 12 PIN,
115A
123309
1
44
BUSS BAR, 2P, 6 PIN, 115A
46
CONNECTOR, lug, power,
115A
47
CAP, lug, power
48
SWITCH, disconnect, ph exp
100A
123968
49
BLOCK, power distribution,
1 pole, 4 wire
123489
1
50
COVER, power distribution
block
123490
1
55
HARNESS, wire, 2 awg
16A646 (1)
-
56
HARNESS, wire, 6 awg,
14 awg
16A650
4
57
HARNESS, wire, 6 awg
58
HARNESS, wire, 4 awg
59
HARNESS, wire, plug, tanks
62
HARNESS, wire, 4 awg;
23 in.
72
LATCH, plug, 30A
123668
123306 (3)
123306 (3)
123310
4
123306 (8)
-
123311
1
16A646 (3)
123968
16A694 (3)
1
24C517
16D536
24E823
24D221
6
24C517
2
16D536
4
24E823
2
 Not shown.
3A0239F
25
Parts
VPM Power Distribution Modules
400V, 3 Phase, Basic Module Shown
1
23
18, 48
19
57
55
49, 50, 8
23
2
62
14
3
69
8
21
5, 6
4
13
9
57
8
3
ti18046a
7
12
46
Circuit Breaker Detail for 400V,
3 Phase, Loaded Module
44
39
8
35
36
37
35
39
10, 47
7
ti18047a
26
3A0239F
Parts
25
26
1c
61
1b
1a
70
20
24
70
71
28
27
29
3A0239F
ti18048a
71
27
Parts
Parts Used on All VPM Modules
Ref.
1
1a
Part
Description
--ENCLOSURE
24D207 SUPPLY, power; 24Vdc, 4A,
100W, 230 Vac
1b 196548 LABEL, caution (on enclosure
door)
1c 123718 FILTER
2
16A360 PANEL, electrical
3
123396 NUT, flange, serrated; 3/8-16
4
117666 TERMINAL, ground
5
113783 SCREW, mach, pan hd
6
100985 WASHER, lock ext
7
16A647 RAIL, din, 17.7 in.
8
103833 SCREW, mach, crbh
9
16A649 HARNESS, ground wire; 8 awg
10
123363 BLOCK, terminal, ground, 10mm
12
24D217 HARNESS, wire, 16 awg, ferrule
13
24D218 HARNESS, wire, 16 awg, ferrule,
terminal ground
14
24D220 HARNESS, wire, 18 awg, ring,
terminal, ground
Qty
1
1
1
Ref.
18
19
24
25
26
27
28
29
35
36
37
46
61
69
71
Part
123969
123967
122487
123589
111800
123679
123398
123590
123296
123350
123298
123306
----123652
1
1
4
1
1
1
1
6
1
5  Not shown.
2
--- Not for sale.
1
Description
SWITCH, disconnect
KNOB, operator disconnect
CABLE, can, male-female, 1.5 m
BUSHING, wire protector, snap-in
SCREW, cap, hex hd
BUSHING, wire protector, snap-in
PLUG, hole, 1 1/2 diameter
PLUG, hole, 2 in. diameter
CIRCUIT, breaker, 2P, 5A
CIRCUIT, breaker, 2P, 15A
CIRCUIT, breaker, 2P, 20A
CONNECTOR, lug, power, 115A
BRACKET, support, electric
LABEL, identification
CABLE, can, male / female 3.5m
Qty
1
1
1
4
10
6
6
4
2
1
2
3
2
1
1
 Replacement Danger and Warning labels, tags, and
cards are available at no cost.
1
Parts that Vary by VPM Module
Use the following table to locate parts that vary by module. See Parts Used on All VPM Modules, page 28, for parts
used on all VPM modules.
Ref. Description
20
21
23
39
42
44
47
48
49
50
55
57
62
70
28
HARNESS, wire, MCM
FILTER, 55A, 3P
HARNESS, wire, 8 awg, ground
CIRCUIT, breaker, 2P, 63A
CIRCUIT, breaker, 3P, 30A
BUSS BAR, 3P, 12 PIN, 115A
BUSS BAR, 3P, 18 PIN, 115A
BUSS BAR, 2P, 6 PIN, 115A
CAP, lug, power (not shown)
SWITCH, disconnect, ph exp 100A
BLOCK, power distribution, 1 pole, 4 wire
COVER, power distribution block
HARNESS, wire, 2 awg
HARNESS, wire, 6 awg
HARNESS, wire, 4 awg, ferruled
HARNESS, wire, 6 awg, ferruled
HARNESS, wire, MCM
400V,
3 phase,
non-CE
230V,
3 phase
24E624
24E625
123688
400v,
3 phase,
CE
24E624
123785
24D216
123668
123302
123308
123309
123310
123310
123311
123968
123489
123490
16A646
16A694
123968
123489
123490
16A646
16A694
24D221
24E620
24E621
16D536
24E620
Qty.
1
2
2
2
2
1
1
2
1
1
1
1
1
6
3
4
1
3A0239F
Parts
3A0239F
29
Graco Standard Warranty
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
30
3A0239F