TECHNICAL MANU AL MANUAL GSX/VSX 13 SEER Condensing Units with R-410A • Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. Copyright © 2007 - 2010 Goodman Manufacturing Company, L.P. RT6113005r9 August 2010 PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. G S X 13 024 PRODUCT FAMILY: S: Split System SEER: SEER Rating 1 A ELECTRICAL: 1: 208-230v 1ph/60Hz 3: 208-230v 3ph/60Hz 4: 460v 3ph/60Hz BRAND: ® G: Goodman Brand A MINOR REVISION: A: Initial Release MAJOR REVISION: A: Initial Release (Standard Feature Set Model) ® S: Goodman Deluxe V: Value PRODUCT TYPE: C: Condenser R-22 X: Condenser R-410A H: Heat Pump R-22 Z: Heat Pump R-410A WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible for any injury or property damage arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment. WARNING 2 NOMINAL CAPACITY 018: 1.5 Tons 024: 2 Tons 030: 2.5 tons 036: 3 Tons 042: 3.5 Tons 048: 4 Tons 060: 5 tons Installation and repair of this unit should be performed ONLY by individuals meeting the requirements (at a minimum) of an "entry level technician", as specified by the Air Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death. WARNING PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. GSX130181A* GSX130241A* GSX130301A* GSX130361A* GSX130421A* GSX130481A* GSX130601A* GSX130363A* GSX130483A* GSX130484A* GSX130603A* GSX130604A* GSX130181B* GSX130241B* GSX130301B* GSX130361B* GSX130421B* GSX130481B* GSX130601B* VSX130181A* VSX130241A* VSX130301A* VSX130361A* VSX130421A* VSX130481A* VSX130181B* VSX130601B* GSX130181C* * Indicates minor revision & is not used for order entry or inventory management WARNING The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices. WARNING To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance. WARNING 3 PRODUCT DESIGN GSX/VSX13 models are available in 1 1/2 through 5 ton sizes and use R-410A refrigerant. They are designed for 208/230 volt single phase applications. Select GSX13 models are available in 208/230 and 460 volt 3-phase applications. These models use R-410A refrigerant. The condenser air is pulled through the condenser coil by a direct drive propeller fan. This condenser air is then discharged out of the top of the cabinet. These units are designed for free air discharge, so no additional resistance like duct work shall be attached. The suction and liquid line connections on present models are of the sweat type for field piping with refrigerant type copper. Front seating valves are factory installed to accept the field run copper. The total refrigerant charge for a normal installation is factory installed in the condensing unit. GSX/ VSX units are charged for the matching evaporator coil and a 15 foot refrigerant line set. Systems should be properly sized by heat gain and loss calculations made according to methods of the Air Conditioning Contractors Association (ACCA) or equivalent. It is the contractors responsibility to ensure the system has adequate capacity to heat or cool the conditioned space. GSX/VSX models use the Copeland Scroll "Ultratech" Series compressors which are specifically designed for R-410A refrigerant. There are a number of design characteristics which are different from the traditional reciprocating and/or scroll compressors. WARNING To avoid possible injury, explosion or death, practice safe handling of refrigerants. Special consideration must be given to location of the condensing unit(s) in regard to structures, obstructions, other units, and any/all other factors that may interfere with air circulation. Where possible, the top of the unit should be completely unobstructed; however, if vertical conditions require placement beneath an obstruction there should be a minimum of 60 inches between the top of the unit and the obstruction(s). The specified dimensions meet requirements for air circulation only. Consult all appropriate regulatory codes prior to determining final clearances. Another important consideration in selecting a location for the unit(s) is the angle to obstructions. Either side adjacent the valves can be placed toward the structure provided the side away from the structure maintains minimum service clearance. Corner installations are strongly discouraged. DO NOT locate the unit: – – Directly under a vent termination for a gas appliance. Within 3 feet of a clothes dryer vent. – Where the refreezing of defrost water would create a hazard. – Where water may rise into the unit. "Ultratech" Series scroll compressors will not have a discharge thermostat, some of the early model scroll compressors required discharge thermostats. Due to their design Scroll compressors are inherently more tolerant of small quantities of liquid refrigerant. NOTE: Even though the compressor section of a Scroll compressor is more tolerant of liquid refrigerant, continued floodback or flooded start conditions may wash oil from the bearing surfaces causing premature bearing failure. NOT RECOMMENDED B Operating pressures and amp draws may differ from standard reciprocating and/or scroll compressors. This information may be found in the "Cooling Performance Data" section. IMPORTANT NOTE: Because of the potential damage to compressors, do not allow suction pressure at service valve to drop below 20 PSIG when pumping unit system down for repair. Outdoor section, depending on line set length and amount of charge in system, may not be able to hold the entire system charge. 4 B A "Ultratech" Series scroll compressors use "POE" or polyolester oil which is NOT compatible with mineral oil based lubricants like 3GS. "POE" oil must be used if additional oil is required. B AA C A OK! B AA OK! C AA AA AA OK! OK! OK! OK! AA C AA C Minimum Airflow Clearance Model Type A B C Residential 10" 10" 18" 12" 12" 18" Light Commercial AA 20" 24" DIMENSIONS PRODUCT DESIGN D W H Model GSX130181A* Dimensions - W x D x H 26" x 26" x 32¼" GSX130241A* 26" x 26" x 32¼" GSX130301A* 26" x 26" x 32¼" GSX130361A* 29" x 29" x 32¼ GSX130421A* 29" x 29" x 34¼" GSX130481A* 29" x 29" x 38¼" GSX130601A* 35½" x 35½" x 38¼" GSX130181B* 26" x 26" x 27½" GSX130241B* 26" x 26" x 27½" GSX130301B* GSX130361B* GSX130363A* GSX130421B* 26" x 26" x 27½" VSX130181A* 26" x 26" x 27½" VSX130241A* 26" x 26" x 27½" VSX130301A* 26" x 26" x 27½" VSX130361A* 29" x 29" x 28¾" VSX130421A* 29" x 29" x 36¼" VSX130481A* 29" x 29" x 36¼" VSX130181B* 26" x 26" x 27½" VSX130601B* 29" x 29" x 40" 29" x 29" x 28¾" 29" x 29" x 36¼" GSX130481B* GSX130483A* GSX130484A* 29" x 29" x 36¼" GSX130601B* GSX130603A* GSX130604A* 29" x 29" x 40" GSX130181C* 26" x 26" x 27½" 5 CONDENSING UNIT SPECIFICATIONS GSX130[18-60]1A* GSX130181A* GSX130241A* GSX130301A* GSX130361A* 18,000 24,000 30,000 36,000 R.L. Amps 9.00 13.4 12.8 16.6 L.R. Amps 48.0 58.3 64.0 79.0 Open 610 PSIG 610 PSIG 610 PSIG 610 PSIG Close 420 PSIG 420 PSIG 420 PSIG 420 PSIG Cooling Capacity, BTUH Compressor High Pressure Switch Condenser Fan Motor Horsepower F.L. Amps Liquid Line, Inches O.D.* Suction Line, Inches O.D.* 1/6 1/6 1/6 1/6 1.10 1.10 1.10 1.10 3/8" 3/8" 3/8" 3/8" 3/4" 3/4" 3/4" 3/4" 120.0 116.0 129.0 131.0 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 12.3 17.9 17.1 21.9 20 30 30 35 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 178 178 180 197 GSX130421A* GSX130481A* GSX130601A* 42,000 48,000 60,000 17.9 112.0 19.8 109.0 26.4 134.0 Open 610 PSIG 610 PSIG 610 PSIG Close 420 PSIG 420 PSIG 420 PSIG Refrigerant Charge Power Supply (1) Minimum Circuit Ampacity Maximum Overcurrent Device (2) Electrical Conduit Size Power Supply (Inches) Approximate Shipping Weight Cooling Capacity, BTUH Compressor R.L. Amps L.R. Amps High Pressure Switch Condenser Fan Motor Horsepower 1/6 1/4 1/4 1.10 1.50 1.50 Liquid Line, Inches O.D.* 3/8" 3/8" 3/8" Suction Line, Inches O.D.* 7/8" 7/8" 7/8" 151.0 166.0 184.0 208/230-60-1 208/230-60-1 208/230-60-1 23.5 26.3 34.5 40 45 60 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 219 225 240 F.L. Amps Refrigerant Charge Power Supply (1) Minimum Circuit Ampacity Maximum Overcurrent Device Electrical Conduit Size (2) Power Supply (Inches) Approximate Shipping Weight (1) (2) Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted. NOTES: * Always check the S&R plate for electrical data on the unit being installed. * Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections. * Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. * Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. 6 CONDENSING UNIT SPECIFICATIONS GSX130181B* GSX130241B* GSX130301B* 18,000 24,000 30,000 R.L. Amps 9.00 13.5 12.8 L.R. Amps 48.0 58.3 64.0 Cooling Capacity, BTUH GSX130[18-60]1B* Compressor High Pressure Switch Open N/A N/A N/A Close N/A N/A N/A 1/6 1/6 1/6 1.10 1.10 1.10 3/8" 3/8" 3/8" Condenser Fan Motor Horsepower F.L. Amps Liquid Line, Inches O.D.* Suction Line, Inches O.D.* 3/4" 3/4" 3/4" Refrigerant Charge 72.0 79.0 81.0 208/230-60-1 208/230-60-1 208/230-60-1 12.4 18.0 17.1 20 30 30 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 149 151 152 GSX130361B* GSX130421B* GSX130481B* GSX130601B* 36,000 42,000 48,000 60,000 R.L. Amps 16.7 L.R. Amps 79.0 17.9 112.0 19.9 109.0 25.0 134.0 Power Supply (1) Minimum Circuit Ampacity Maximum Overcurrent Device (2) Electrical Conduit Size Power Supply (Inches) Approximate Shipping Weight Cooling Capacity, BTUH Compressor High Pressure Switch Open N/A N/A N/A N/A Close N/A N/A N/A N/A Condenser Fan Motor Horsepower 1/6 1/4 1/4 1/4 1.10 1.50 1.50 1.50 Liquid Line, Inches O.D.* 3/8" 3/8" 3/8" 3/8" Suction Line, Inches O.D.* 3/4" 7/8" 7/8" 7/8" Refrigerant Charge 92.0 124.0 128.0 125.0 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 22.0 23.9 26.4 32.8 35 40 45 50 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 159 194 195 200 F.L. Amps Power Supply (1) Minimum Circuit Ampacity Maximum Overcurrent Device (2) Electrical Conduit Size Power Supply (Inches) Approximate Shipping Weight (1) (2) Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted. NOTES: * Always check the S&R plate for electrical data on the unit being installed. * Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections. * Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. * Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. 7 CONDENSING UNIT SPECIFICATIONS GSX130181C* GSX130181C* Cooling Capacity, BTUH 18,000 SEER/EER 13 / 11 Compressor R.L. Amps 6.70 L.R. Amps 40.0 High Pressure Switch Open N/A Close N/A Condenser Fan Motor Horsepower 1/6 F.L. Amps 1.10 Liquid Line, Inches O.D.* 3/8" Suction Line, Inches O.D.* 3/4" Refrigerant Charge 71.0 Power Supply 208/230-60-1 (1) 9.5 Minimum Circuit Ampacity (2) Maximum Overcurrent Device Electrical Conduit Size Power Supply (Inches) Approximate Shipping Weight (1) (2) 15 1/2 or 3/4 135 Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted. NOTES: * Always check the S&R plate for electrical data on the unit being installed. * Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections. * Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. * Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. 8 CONDENSING UNIT SPECIFICATIONS GSX130[36-60][3,4]* * GSX130363A* GSX130483A* GSX130484A* GSX130603A* GSX130604A* Cooling Capacity, BTUH 36,000 48,000 48,000 60,000 60,000 74 76 76 77 77 R.L. Amps 10.40 13.1 6.1 15.9 7.1 L.R. Amps 73.0 83.1 41.0 110.0 52.0 Scroll Scroll Scroll Scroll Scroll 1/6 1/4 1/4 1/4 1/4 1.10 1.50 0.80 1.50 0.80 Liquid Line, Inches O.D.* 3/8" 3/8" 3/8" 3/8" 3/8" Suction Line, Inches O.D.* 7/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8" 3/8" 3/8" 3/8" 3/8" 3/8" Decibels Compressor Type Condenser Fan Motor Horsepower F.L. Amps Refrigerant System Liquid Valve Connection, Inches O.D.* Suction Valve Connection, Inches O.D.* 3 3/4" 3 7/8" 4 7/8" 4 7/8" 4 7/8" 4 Refrigerant Charge 92.0 128.0 128.0 125.0 125.0 Piston Size 0.068 0.080 0.080 0.086 0.086 460-60-3 208/230-60-3 460-60-3 Power Supply 208/230-60-3 208/230-60-3 (1) Minimum Circuit Ampacity (2) Maximum Overcurrent Device Min / Max Volts 14.1 17.9 8.4 21.4 9.7 20 30 15 35 15 197 / 253 197 / 253 414 / 506 197 / 253 414 / 506 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 196 190 189 197 196 Electrical Conduit Size Power Supply (Inches) Approximate Shipping Weight (1) (2) (3) (4) Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted. Installer must supply a 3/4" to 7/8" adapter for suction line connections. Installer must supply a 7/8" to 1 1/8" adapter for suction line connections. NOTES: * Always check the S&R plate for electrical data on the unit being installed. * Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections. * Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. * Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. 9 CONDENSING UNIT SPECIFICATIONS VSX130181A* VSX130241A* VSX130301A* Cooling Capacity, BTUH 18,000 24,000 30,000 SEER/EER 13 / 11 13 / 11 13 / 11 R.L. Amps 9.00 13.5 12.8 L.R. Amps 48.0 58.3 64.0 VSX130[18-60]1A* Compressor High Pressure Switch Open N/A N/A N/A Close N/A N/A N/A Condenser Fan Motor Horsepower 1/6 1/6 1/6 1.10 1.10 1.10 Liquid Line, Inches O.D.* 3/8" 3/8" 3/8" Suction Line, Inches O.D.* 3/4" 3/4" 3/4" Refrigerant Charge 72.0 79.0 81.0 208/230-60-1 208/230-60-1 208/230-60-1 12.3 18.0 17.1 20 30 30 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 149 151 152 F.L. Amps Power Supply Minimum Circuit Ampacity (1) Maximum Overcurrent Device (2) Electrical Conduit Size Power Supply (Inches) Approximate Shipping Weight VSX130361A* VSX130421A* VSX130481A* Cooling Capacity, BTUH 36,000 42,000 48,000 SEER/EER 13 / 11 13 / 11 13 / 11 R.L. Amps 16.7 L.R. Amps 79.0 17.9 112.0 19.9 109.0 Compressor High Pressure Switch Open N/A N/A N/A Close N/A N/A N/A Condenser Fan Motor Horsepower 1/6 1/4 1/4 1.10 1.50 1.50 Liquid Line, Inches O.D.* 3/8" 3/8" 3/8" Suction Line, Inches O.D.* 3/4" 7/8" 7/8" Refrigerant Charge 95.0 124.0 128.0 208/230-60-1 208/230-60-1 208/230-60-1 21.9 23.9 26.3 35 40 45 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 197 194 195 F.L. Amps Power Supply Minimum Circuit Ampacity (1) Maximum Overcurrent Device (2) Electrical Conduit Size Power Supply (Inches) Approximate Shipping Weight (1) (2) Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted. NOTES: * Always check the S&R plate for electrical data on the unit being installed. * Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections. * Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. * Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. 10 CONDENSING UNIT SPECIFICATIONS VSX130181B* VSX130601B* Cooling Capacity, BTUH 18,000 60,000 SEER/EER 13 / 11 13 / 11 VSX130[18 & 60]1B* Compressor R.L. Amps 6.70 25.0 L.R. Amps 40.0 134.0 High Pressure Switch Open N/A N/A Close N/A N/A Condenser Fan Motor Horsepower 1/6 1/4 1.10 1.50 3/8" 3/8" Suction Line, Inches O.D.* 3/4" 1 1/8" Refrigerant Charge 71.0 208/230-60-1 125.0 208/230-60-1 9.5 26.3 15 45 1/2 or 3/4 1/2 or 3/4 135 200 F.L. Amps Liquid Line, Inches O.D.* Power Supply Minimum Circuit Ampacity (1) Maximum Overcurrent Device (2) Electrical Conduit Size Power Supply (Inches) Approximate Shipping Weight (1) (2) Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted. NOTES: * Always check the S&R plate for electrical data on the unit being installed. * Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections. * Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. * Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. 11 12 75 70 IDB* 17.7 0.58 16 1.28 4.7 227 111 16.4 0.55 16 1.25 4.6 220 107 18.5 0.73 18 1.30 4.8 232 113 17.9 0.70 19 1.29 4.7 230 112 16.5 0.68 20 1.26 4.6 223 108 MBh 17.1 S/T 0.69 Delta T 18 KW 1.25 AMPS 4.6 HI PR 211 LO PR 104 MBh 15.8 S/T 0.66 Delta T 18 KW 1.22 AMPS 4.5 HI PR 205 LO PR 101 MBh 17.9 S/T 0.82 Delta T 20 KW 1.27 AMPS 4.7 HI PR 216 LO PR 106 MBh 17.4 S/T 0.78 Delta T 21 KW 1.26 AMPS 4.6 HI PR 213 LO PR 105 MBh 16.1 S/T 0.75 Delta T 21 KW 1.23 AMPS 4.5 HI PR 207 LO PR 102 600 525 675 600 525 67 17.9 0.51 16 1.30 4.8 235 118 19.4 0.53 16 1.33 4.9 242 122 20.0 0.56 15 1.34 4.9 245 123 17.9 0.38 12 1.29 4.7 233 117 19.4 0.40 12 1.32 4.9 240 121 20.0 0.42 11 1.33 4.9 242 122 * Entering Indoor Dry Bulb Temperature 675 63 18.3 0.60 15 1.29 4.7 230 112 59 MBh 17.6 S/T 0.72 Delta T 17 KW 1.26 AMPS 4.6 HI PR 213 LO PR 105 Airflow 65 19.2 0.33 11 1.34 4.9 245 126 20.8 0.34 11 1.37 5.1 253 130 21.5 0.36 10 1.38 5.1 255 131 - - - 71 59 15.7 0.78 22 1.32 4.9 232 108 17.0 0.81 21 1.36 5.0 239 111 17.5 0.85 20 1.37 5.1 242 112 15.4 0.69 19 1.31 4.8 230 106 16.7 0.71 18 1.35 5.0 237 110 17.2 0.75 18 1.36 5.0 239 111 63 67 17.5 0.53 16 1.39 5.2 264 125 19.0 0.55 16 1.43 5.3 272 129 19.5 0.58 15 1.44 5.3 275 130 17.5 0.40 12 1.38 5.1 261 124 19.0 0.41 12 1.42 5.3 269 127 19.6 0.43 12 1.43 5.3 272 129 18.8 0.34 11 1.44 5.3 275 133 20.3 0.35 11 1.47 5.5 284 137 21.0 0.37 11 1.48 5.5 287 139 - - - 71 59 15.3 0.80 22 1.41 5.3 264 112 16.6 0.83 21 1.44 5.4 272 115 17.1 0.87 20 1.45 5.5 275 116 15.1 0.71 19 1.39 5.2 261 111 16.3 0.73 18 1.43 5.4 270 114 16.8 0.77 18 1.44 5.4 272 115 15.8 0.72 20 1.43 5.4 284 119 17.1 0.74 19 1.47 5.6 293 123 17.6 0.78 19 1.48 5.6 296 124 15.6 0.59 16 1.42 5.4 281 118 16.9 0.61 16 1.46 5.5 290 121 17.4 0.64 15 1.47 5.6 293 123 17.1 0.54 16 1.48 5.6 300 130 18.5 0.56 16 1.52 5.8 309 134 19.1 0.59 15 1.53 5.8 313 135 17.1 0.41 12 1.47 5.6 297 129 18.5 0.42 12 1.50 5.7 306 132 19.1 0.44 12 1.52 5.8 309 134 18.3 0.35 11 1.53 5.8 313 138 19.9 0.36 11 1.56 6.0 323 143 20.5 0.38 11 1.58 6.0 326 144 - - - 15.0 0.83 22 1.48 5.7 301 117 16.2 0.86 21 1.51 5.8 310 121 16.7 0.90 20 1.52 5.9 313 122 14.7 0.73 19 1.46 5.6 298 116 15.9 0.76 18 1.50 5.8 307 120 16.4 0.79 18 1.51 5.8 310 121 15.4 0.74 20 1.51 5.8 324 125 16.7 0.77 20 1.54 6.0 334 129 17.2 0.81 19 1.56 6.0 337 130 15.2 0.61 16 1.49 5.7 320 124 16.5 0.63 16 1.53 5.9 330 127 17.0 0.66 15 1.54 6.0 334 129 16.7 0.56 16 1.55 6.0 342 136 18.1 0.58 16 1.59 6.2 352 141 18.6 0.61 15 1.61 6.2 356 142 16.7 0.42 12 1.54 5.9 338 135 18.1 0.44 12 1.58 6.1 349 139 18.6 0.46 12 1.59 6.2 352 141 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 NOTE: Shaded area is ACCA (TVA) conditions 16.2 0.70 20 1.35 5.0 250 114 17.5 0.73 19 1.38 5.1 258 118 18.0 0.76 19 1.40 5.2 260 119 16.0 0.57 16 1.34 4.9 247 113 17.3 0.60 16 1.37 5.1 255 117 17.9 0.63 15 1.38 5.1 258 118 75 MODEL: GSX130181A* / CA*F1824*6** / ZP16K5E-PFV 17.9 0.36 11 1.61 6.2 357 145 19.4 0.37 11 1.65 6.4 368 150 20.0 0.39 11 1.66 6.5 371 151 - - - 71 EXPANDED PERFORMANCE DATA 59 14.2 0.86 21 1.54 6.0 338 123 15.4 0.89 21 1.57 6.2 349 127 15.9 0.93 20 1.59 6.3 352 128 14.0 0.76 18 1.52 6.0 335 122 15.1 0.78 18 1.56 6.1 345 126 15.6 0.82 17 1.57 6.2 349 127 63 14.6 0.77 20 1.57 6.2 364 131 15.8 0.80 19 1.61 6.3 375 135 16.3 0.84 19 1.62 6.4 379 136 14.5 0.63 16 1.56 6.1 361 130 15.7 0.65 16 1.60 6.3 372 134 16.2 0.69 15 1.61 6.3 375 135 67 15.8 0.58 16 1.62 6.4 385 143 17.2 0.60 16 1.66 6.6 396 147 17.7 0.63 15 1.67 6.6 400 149 15.9 0.44 12 1.61 6.3 381 141 17.2 0.45 12 1.65 6.5 392 146 17.7 0.48 11 1.66 6.6 396 147 105 17.0 0.37 11 1.67 6.6 401 152 18.4 0.39 11 1.71 6.8 414 157 19.0 0.41 11 1.73 6.9 418 158 - - - 71 59 13.2 0.87 20 1.59 6.4 374 127 14.3 0.90 20 1.63 6.6 386 131 14.7 0.94 19 1.64 6.6 389 133 12.9 0.76 17 1.57 6.3 370 126 14.0 0.79 17 1.61 6.5 382 130 14.4 0.83 16 1.63 6.6 385 131 63 13.5 0.78 18 1.62 6.5 402 135 14.7 0.80 18 1.66 6.7 415 140 15.1 0.84 17 1.68 6.8 419 141 13.4 0.64 15 1.61 6.5 398 134 14.5 0.66 15 1.65 6.7 411 138 15.0 0.69 14 1.66 6.7 415 140 67 14.7 0.59 15 1.67 6.8 425 148 15.9 0.61 15 1.72 7.0 438 152 16.4 0.64 14 1.73 7.0 442 154 14.7 0.44 11 1.66 6.7 421 146 15.9 0.46 11 1.70 6.9 434 151 16.4 0.48 11 1.72 7.0 438 152 115 15.7 0.38 10 1.73 7.0 443 157 17.1 0.39 10 1.77 7.2 457 162 17.6 0.41 10 1.79 7.3 461 164 - - - 71 COOLING OPERATION COOLING PERFORMANCE DATA GSX130181A* 85 80 IDB* 600 18.4 0.87 24 1.31 4.8 234 114 19.8 0.82 22 1.36 5.0 250 126 21.2 0.67 19 1.40 5.2 261 134 71 21.3 0.51 15 1.39 5.2 258 132 20.7 0.49 16 1.38 5.1 255 131 19.1 0.47 16 1.35 5.0 248 127 19.0 0.61 20 1.36 5.0 250 128 18.0 0.90 25 1.28 4.7 218 107 MBh S/T Delta T KW AMPS HI PR LO PR 18.9 0.91 23 1.32 4.9 237 115 67 19.9 0.69 19 1.35 5.0 247 124 19.4 0.66 19 1.34 4.9 245 123 17.9 0.63 20 1.31 4.8 238 119 MBh 16.6 17.0 17.8 S/T 0.87 0.84 0.76 Delta T 25 25 24 525 KW 1.25 1.28 1.32 AMPS 4.6 4.7 4.9 HI PR 211 227 240 LO PR 104 110 121 * Entering Indoor Dry Bulb Temperature 18.6 0.94 24 1.29 4.8 220 108 MBh S/T Delta T KW AMPS HI PR LO PR 63 18.7 0.84 21 1.31 4.8 234 114 18.1 0.81 22 1.30 4.8 232 113 16.7 0.78 23 1.27 4.7 225 109 20.5 0.64 20 1.39 5.2 258 132 59 18.3 0.90 22 1.28 4.7 218 107 17.7 0.86 23 1.27 4.7 216 106 16.4 0.83 24 1.24 4.5 209 103 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 19.3 0.78 23 1.35 5.0 247 124 675 525 600 675 Airflow 65 16.3 0.90 26 1.35 5.0 237 110 17.6 0.93 25 1.38 5.1 244 113 18.1 0.98 24 1.39 5.1 247 114 59 17.8 0.93 23 1.38 5.1 244 113 17.3 0.89 24 1.37 5.1 242 112 16.0 0.86 24 1.34 4.9 235 109 16.6 0.87 25 1.37 5.1 255 117 NOTE: 18.0 0.90 25 1.41 5.2 263 120 18.5 0.94 24 1.42 5.3 265 122 63 18.2 0.88 22 1.41 5.2 263 120 17.7 0.83 23 1.40 5.2 260 119 16.3 0.80 23 1.36 5.0 252 116 18.8 0.81 23 1.45 5.4 278 131 19.4 0.85 22 1.46 5.4 280 133 67 19.5 0.71 19 1.45 5.4 278 131 18.9 0.68 20 1.44 5.3 275 130 17.4 0.65 20 1.41 5.2 267 126 20.1 0.66 20 1.50 5.6 290 140 20.7 0.69 19 1.51 5.7 292 141 71 20.8 0.53 15 1.50 5.6 290 140 20.2 0.51 16 1.49 5.5 287 139 18.6 0.49 16 1.45 5.4 278 134 17.2 0.96 25 1.46 5.5 278 118 17.7 1.00 24 1.47 5.6 281 119 59 17.4 0.96 23 1.46 5.5 278 118 16.9 0.91 24 1.45 5.5 275 116 15.6 0.88 24 1.42 5.3 267 113 17.4 18.5 15.9 0.78 0.64 0.92 24 21 26 1.42 1.46 1.43 5.2 5.4 5.4 269 281 269 127 136 114 Shaded area is AHRI 75 MODEL: GSX130181AA / CA*F1824*6** / ZP16K5E-PFV 18.4 0.83 23 1.54 5.9 316 137 18.9 0.87 22 1.55 5.9 319 138 19.6 0.68 20 1.59 6.1 329 145 20.2 0.71 19 1.60 6.1 333 147 16.2 16.9 18.1 0.89 0.80 0.65 25 24 21 1.46 1.50 1.55 5.5 5.7 5.9 290 306 319 121 132 141 Rating Conditions 17.5 0.92 25 1.49 5.7 299 125 18.1 0.97 24 1.51 5.7 302 126 15.5 0.95 26 1.50 5.8 307 120 16.8 0.99 25 1.54 5.9 316 123 17.3 1.00 24 1.55 6.0 320 125 15.8 0.92 25 1.53 5.9 330 127 17.1 0.95 25 1.57 6.1 341 131 17.6 1.00 24 1.58 6.1 344 133 16.5 0.83 24 1.58 6.1 349 139 17.9 0.86 24 1.62 6.3 360 143 18.4 0.90 23 1.63 6.3 363 145 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 17.8 19.0 20.3 17.0 17.4 18.5 0.90 0.73 0.55 1.00 0.93 0.75 22 19 15 23 22 19 1.49 1.54 1.59 1.54 1.57 1.62 5.7 5.9 6.1 5.9 6.1 6.3 299 316 329 316 341 360 125 137 145 123 131 143 17.3 18.5 19.7 16.5 16.8 18.0 0.86 0.70 0.52 0.94 0.88 0.72 20 23 20 16 24 23 1.61 1.48 1.53 1.58 1.52 1.56 5.6 5.8 6.0 5.9 6.0 6.2 296 313 326 313 337 356 124 135 144 122 130 142 15.9 17.0 18.2 15.2 15.6 16.6 0.83 0.67 0.50 0.91 0.85 0.69 23 20 16 24 23 20 1.45 1.49 1.54 1.49 1.52 1.57 5.5 5.7 5.9 5.7 5.9 6.0 287 303 316 304 327 345 120 131 140 119 126 138 17.6 0.67 21 1.63 6.3 364 148 19.1 0.70 20 1.67 6.5 375 153 19.7 0.73 20 1.69 6.6 379 154 71 19.8 0.56 15 1.67 6.5 375 153 19.2 0.54 16 1.66 6.5 371 151 17.8 0.52 16 1.62 6.3 360 147 EXPANDED PERFORMANCE DATA 14.7 0.99 25 1.56 6.1 345 126 15.9 1.00 24 1.60 6.3 356 129 16.4 1.00 22 1.61 6.4 360 131 59 16.1 1.00 22 1.60 6.3 356 129 15.7 0.98 23 1.59 6.3 352 128 14.5 0.94 24 1.55 6.1 342 124 15.0 0.95 25 1.59 6.3 372 134 16.2 0.99 25 1.63 6.5 383 138 16.7 1.00 23 1.65 6.5 387 139 63 16.5 0.96 22 1.63 6.5 383 138 16.0 0.92 22 1.62 6.4 379 136 14.8 0.88 23 1.58 6.2 368 132 15.7 0.86 24 1.65 6.5 392 146 17.0 0.89 23 1.69 6.7 405 150 17.5 0.94 22 1.70 6.7 409 152 67 17.6 0.78 19 1.69 6.7 405 150 17.1 0.75 20 1.67 6.6 401 149 15.8 0.72 20 1.63 6.4 388 144 105 16.8 0.70 20 1.70 6.7 409 155 18.2 0.72 20 1.74 6.9 422 160 18.7 0.76 19 1.76 7.0 426 162 71 18.8 0.58 15 1.74 6.9 422 160 18.3 0.56 16 1.73 6.9 418 158 16.9 0.54 16 1.69 6.7 405 154 13.6 1.00 24 1.61 6.5 382 130 14.8 1.00 23 1.65 6.7 393 134 15.2 1.00 21 1.67 6.8 397 135 59 14.9 1.00 20 1.65 6.7 393 134 14.5 0.99 22 1.64 6.6 389 133 13.4 0.95 22 1.60 6.4 378 129 13.9 0.96 23 1.65 6.7 411 138 15.0 1.00 23 1.69 6.9 423 142 15.5 1.00 21 1.70 6.9 427 144 63 15.3 0.97 20 1.69 6.9 423 142 14.8 0.92 21 1.68 6.8 419 141 13.7 0.89 21 1.64 6.6 406 137 14.5 0.87 22 1.70 6.9 434 151 15.8 0.90 22 1.75 7.1 447 155 16.2 0.94 21 1.76 7.2 451 157 67 16.3 0.79 18 1.75 7.1 447 155 15.8 0.75 18 1.73 7.0 443 154 14.6 0.73 19 1.69 6.8 429 149 115 15.5 0.70 19 1.76 7.2 452 161 16.8 0.73 19 1.80 7.4 466 166 17.3 0.77 18 1.82 7.4 471 167 71 17.4 0.59 14 1.80 7.4 466 166 16.9 0.56 15 1.79 7.3 462 164 15.6 0.54 15 1.74 7.1 448 159 COOLING OPERATION COOLING PERFORMANCE DATA GSX130181A* 13 14 75 70 IDB* 22.7 0.58 15 1.64 5.8 242 106 20.9 0.56 15 1.61 5.6 235 103 23.6 0.75 18 1.67 5.9 247 108 22.9 0.71 18 1.66 5.9 244 107 21.1 0.69 19 1.62 5.7 237 104 MBh 21.9 S/T 0.70 Delta T 17 KW 1.61 AMPS 5.7 HI PR 225 LO PR 100 MBh 20.2 S/T 0.67 Delta T 18 KW 1.58 AMPS 5.5 HI PR 218 LO PR 97 MBh 22.9 S/T 0.83 Delta T 19 KW 1.64 AMPS 5.8 HI PR 229 LO PR 102 MBh 22.3 S/T 0.79 Delta T 20 KW 1.62 AMPS 5.7 HI PR 227 LO PR 101 MBh 20.5 S/T 0.77 Delta T 20 KW 1.59 AMPS 5.6 HI PR 220 LO PR 98 810 709 911 810 709 67 22.9 0.52 15 1.67 5.9 250 114 24.8 0.54 15 1.71 6.1 258 117 25.5 0.56 15 1.72 6.1 261 118 22.9 0.39 12 1.65 5.8 248 112 24.8 0.40 11 1.69 6.0 256 116 25.6 0.42 11 1.70 6.0 258 117 * Entering Indoor Dry Bulb Temperature 911 63 23.4 0.61 14 1.66 5.9 244 107 59 MBh 22.5 S/T 0.73 Delta T 17 KW 1.62 AMPS 5.7 HI PR 227 LO PR 101 Airflow 65 24.6 0.33 11 1.72 6.1 261 121 26.6 0.35 10 1.76 6.3 269 125 27.4 0.36 10 1.77 6.3 272 126 - - - 71 59 20.1 0.79 21 1.70 6.0 247 103 21.7 0.82 20 1.74 6.2 255 107 22.4 0.86 20 1.75 6.2 257 108 19.7 0.70 18 1.69 6.0 245 102 21.4 0.72 18 1.73 6.1 252 106 22.0 0.76 17 1.74 6.2 255 107 63 67 22.4 0.54 16 1.79 6.4 281 120 24.2 0.56 15 1.83 6.5 290 124 24.9 0.58 15 1.84 6.6 293 125 22.4 0.40 12 1.77 6.3 278 119 24.3 0.42 12 1.81 6.5 287 123 25.0 0.44 11 1.83 6.5 290 124 24.0 0.35 11 1.84 6.6 293 128 26.0 0.36 11 1.88 6.8 302 132 26.8 0.38 10 1.90 6.9 305 133 - - - 71 59 19.6 0.81 21 1.80 6.5 281 107 21.2 0.84 20 1.84 6.7 290 111 21.9 0.89 20 1.86 6.8 293 112 19.3 0.72 18 1.79 6.5 278 106 20.9 0.74 18 1.83 6.7 287 110 21.5 0.78 17 1.84 6.7 290 111 20.2 0.73 19 1.84 6.7 303 114 21.8 0.76 19 1.88 6.9 312 118 22.5 0.79 18 1.89 6.9 315 119 20.0 0.60 15 1.82 6.6 300 113 21.6 0.62 15 1.87 6.8 309 117 22.3 0.65 15 1.88 6.9 312 118 21.8 0.55 16 1.89 6.9 320 125 23.6 0.57 15 1.94 7.1 329 129 24.4 0.60 15 1.95 7.2 333 130 21.9 0.41 12 1.88 6.9 316 124 23.7 0.43 12 1.92 7.0 326 127 24.4 0.45 11 1.94 7.1 329 129 23.4 0.35 11 1.95 7.2 333 133 25.4 0.37 11 2.00 7.4 344 137 26.1 0.39 10 2.01 7.5 347 138 - - - 19.1 0.84 21 1.89 7.0 320 113 20.7 0.87 20 1.93 7.2 330 116 21.3 0.91 20 1.95 7.3 333 118 18.8 0.74 18 1.87 6.9 317 112 20.4 0.77 18 1.92 7.1 327 115 21.0 0.80 17 1.93 7.2 330 116 23.1 0.59 15 2.03 7.6 375 135 21.3 0.57 16 1.99 7.4 364 131 19.7 0.75 19 1.93 7.2 345 120 23.8 0.62 15 2.05 7.7 379 136 22.0 0.82 18 1.99 7.4 359 125 21.3 0.78 19 1.97 7.4 355 124 21.3 0.43 12 1.97 7.3 360 130 23.1 0.44 12 2.02 7.5 371 134 23.8 0.47 11 2.03 7.6 375 135 19.5 0.62 16 1.91 7.1 341 119 21.1 0.64 15 1.96 7.3 352 123 21.7 0.67 15 1.97 7.4 355 124 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 NOTE: Shaded area is ACCA (TVA) conditions 20.7 0.71 19 1.74 6.2 266 110 22.4 0.74 19 1.78 6.3 274 113 23.0 0.77 18 1.79 6.4 277 115 20.4 0.58 15 1.72 6.1 263 109 22.2 0.61 15 1.76 6.3 272 112 22.8 0.63 15 1.78 6.3 274 113 75 MODEL: GSX130241A* / CA*F1824*6** / ZP20K5-PFV 22.9 0.37 11 2.05 7.7 380 140 24.8 0.38 11 2.10 7.9 391 144 25.5 0.40 10 2.11 8.0 395 145 - - - 71 EXPANDED PERFORMANCE DATA 59 18.2 0.87 21 1.96 7.4 360 118 19.7 0.90 20 2.01 7.6 371 122 20.3 0.95 19 2.03 7.7 375 123 17.8 0.77 18 1.95 7.4 357 117 19.3 0.80 17 1.99 7.6 368 121 19.9 0.83 17 2.01 7.6 371 122 63 18.7 0.78 19 2.00 7.6 388 126 20.2 0.81 19 2.05 7.8 400 130 20.9 0.85 18 2.07 7.9 404 131 18.5 0.64 15 1.99 7.5 384 125 20.0 0.66 15 2.04 7.8 396 128 20.6 0.70 15 2.05 7.8 400 130 67 20.2 0.59 15 2.07 7.9 409 137 21.9 0.61 15 2.12 8.1 422 142 22.6 0.64 15 2.13 8.2 426 143 20.3 0.44 12 2.05 7.8 405 136 22.0 0.46 11 2.10 8.0 418 140 22.6 0.48 11 2.12 8.1 422 142 105 21.7 0.38 11 2.13 8.2 427 146 23.5 0.39 11 2.18 8.4 440 151 24.2 0.41 10 2.20 8.5 445 152 - - - 71 59 16.8 0.88 19 2.03 7.9 398 122 18.2 0.91 19 2.08 8.1 410 126 18.8 0.96 18 2.09 8.2 415 127 16.5 0.77 17 2.01 7.8 394 121 17.9 0.80 16 2.06 8.0 406 125 18.4 0.84 16 2.08 8.1 410 126 63 17.3 0.79 18 2.07 8.1 428 130 18.8 0.82 17 2.12 8.3 442 134 19.3 0.86 17 2.14 8.4 446 136 17.1 0.65 14 2.05 8.0 424 129 18.6 0.67 14 2.10 8.2 437 133 19.1 0.70 14 2.12 8.3 442 134 67 18.7 0.60 14 2.13 8.3 452 142 20.3 0.62 14 2.19 8.6 466 146 20.9 0.65 14 2.20 8.7 471 148 18.8 0.45 11 2.12 8.3 448 141 20.3 0.46 11 2.17 8.5 462 145 21.0 0.49 10 2.19 8.6 466 146 115 20.1 0.38 10 2.20 8.7 472 151 21.8 0.40 10 2.26 8.9 486 156 22.4 0.42 9 2.27 9.0 491 158 - - - 71 COOLING OPERATION COOLING PERFORMANCE DATA GSX130241A* 85 80 IDB* 24.2 0.92 23 1.69 6.0 252 111 23.5 0.88 24 1.68 6.0 249 109 21.7 0.85 24 1.64 5.8 242 106 MBh 23.7 S/T 0.96 Delta T 23 KW 1.66 AMPS 5.9 HI PR 234 LO PR 104 MBh 23.0 S/T 0.91 Delta T 24 KW 1.65 AMPS 5.8 HI PR 232 LO PR 103 MBh 21.3 S/T 0.88 Delta T 24 KW 1.61 AMPS 5.7 HI PR 225 LO PR 100 810 709 22.7 0.77 23 1.69 6.0 255 116 24.6 0.80 22 1.73 6.2 263 120 25.3 0.83 21 1.74 6.2 266 121 67 25.5 0.70 18 1.73 6.2 263 120 24.7 0.67 19 1.72 6.1 261 118 22.8 0.64 19 1.68 5.9 253 115 * Entering Indoor Dry Bulb Temperature 911 709 810 911 63 23.8 0.86 21 1.68 6.0 249 109 23.1 0.82 21 1.67 5.9 247 108 21.4 0.79 22 1.63 5.8 240 105 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 59 23.3 0.91 22 1.65 5.8 232 103 22.6 0.87 22 1.64 5.8 229 102 20.9 0.84 23 1.60 5.6 223 99 Airflow 65 24.2 0.62 20 1.74 6.2 266 123 26.2 0.65 19 1.78 6.4 275 127 27.0 0.68 18 1.80 6.4 277 129 71 27.2 0.52 14 1.78 6.4 275 127 26.4 0.50 15 1.77 6.3 272 126 24.4 0.48 15 1.73 6.2 264 122 20.8 0.91 25 1.73 6.1 252 105 22.5 0.95 24 1.77 6.3 260 109 23.2 0.99 23 1.78 6.4 263 110 59 22.8 0.95 22 1.77 6.3 260 109 22.1 0.90 23 1.75 6.2 257 108 20.4 0.87 23 1.71 6.1 250 104 22.2 0.80 23 1.81 6.5 287 122 24.0 0.82 22 1.86 6.7 296 126 24.8 0.86 22 1.87 6.7 298 128 67 24.9 0.72 18 1.86 6.7 296 126 24.2 0.69 19 1.84 6.6 293 125 22.3 0.67 19 1.80 6.4 284 121 23.7 0.65 20 1.87 6.7 299 130 25.6 0.67 19 1.91 6.9 308 134 26.4 0.70 19 1.93 7.0 311 136 71 26.6 0.54 15 1.91 6.9 308 134 25.8 0.52 15 1.90 6.9 305 133 23.8 0.50 15 1.86 6.7 296 129 20.3 0.94 25 1.83 6.7 287 110 22.0 0.97 24 1.87 6.8 296 113 22.6 1.00 23 1.89 6.9 299 114 59 22.2 1.00 22 1.87 6.8 296 113 21.6 0.93 23 1.86 6.8 293 112 19.9 0.89 23 1.81 6.6 284 109 20.7 0.90 24 1.87 6.8 309 117 22.4 0.94 24 1.91 7.0 318 120 23.1 0.98 23 1.92 7.1 321 121 21.7 0.82 23 1.92 7.0 326 127 23.5 0.85 23 1.97 7.2 336 131 24.2 0.89 22 1.98 7.3 339 133 23.1 0.66 20 1.98 7.3 340 136 25.0 0.69 19 2.03 7.5 351 140 25.8 0.72 19 2.05 7.6 354 141 19.8 0.97 25 1.92 7.1 327 115 21.4 1.00 24 1.96 7.3 337 119 22.1 1.00 22 1.98 7.4 340 120 20.2 0.93 24 1.96 7.3 352 122 21.9 0.97 24 2.00 7.5 363 126 22.5 1.00 23 2.02 7.6 366 128 21.1 0.84 23 2.02 7.5 371 134 22.9 0.87 23 2.07 7.8 383 138 23.6 0.92 22 2.08 7.8 387 139 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 22.7 24.3 26.0 21.7 22.2 23.7 0.91 0.74 0.55 1.00 0.94 0.77 21 18 15 22 21 18 1.91 1.97 2.03 1.96 2.00 2.07 7.0 7.2 7.5 7.3 7.5 7.8 318 336 351 337 363 383 120 131 140 119 126 138 22.1 23.6 25.2 21.1 21.5 23.0 0.87 0.71 0.53 0.96 0.90 0.73 19 22 19 15 23 22 2.05 1.89 1.95 2.01 1.95 1.99 6.9 7.2 7.5 7.3 7.4 7.7 315 333 347 334 359 379 119 130 138 118 125 137 20.4 21.8 23.3 19.4 19.9 21.2 0.84 0.68 0.51 0.92 0.86 0.70 22 19 15 23 22 19 1.85 1.91 1.97 1.90 1.94 2.00 6.8 7.0 7.2 7.1 7.2 7.5 306 323 337 324 348 368 115 126 134 114 121 132 NOTE: Shaded area is AHRI Rating Conditions 21.2 0.88 24 1.76 6.3 271 112 22.9 0.91 24 1.80 6.5 280 116 23.6 0.96 23 1.82 6.5 283 117 63 23.3 0.89 21 1.80 6.5 280 116 22.6 0.85 22 1.79 6.4 277 115 20.9 0.82 22 1.75 6.2 269 111 75 MODEL: GSX130241AA / CA*F1824*6** / ZP20K5-PFV 22.5 0.68 20 2.08 7.8 387 142 24.4 0.71 20 2.13 8.0 399 147 25.1 0.74 19 2.15 8.1 403 148 71 25.3 0.57 15 2.13 8.0 399 147 24.6 0.55 15 2.11 8.0 395 145 22.7 0.53 15 2.06 7.7 383 141 EXPANDED PERFORMANCE DATA 18.8 1.00 24 1.99 7.6 368 121 20.4 1.00 23 2.04 7.8 379 124 21.0 1.00 21 2.06 7.9 383 126 59 20.6 1.00 21 2.04 7.8 379 124 20.0 0.99 23 2.03 7.7 375 123 18.5 0.96 23 1.98 7.5 364 119 19.2 0.97 24 2.03 7.8 396 128 20.8 1.00 24 2.08 8.0 408 132 21.4 1.00 22 2.10 8.1 412 134 63 21.1 1.00 21 2.08 8.0 408 132 20.5 0.93 22 2.07 7.9 404 131 18.9 0.90 22 2.02 7.7 392 127 20.1 0.87 23 2.10 8.0 418 140 21.7 0.91 22 2.15 8.3 431 144 22.4 0.95 21 2.17 8.3 435 146 67 22.5 0.79 18 2.15 8.3 431 144 21.9 0.76 19 2.13 8.2 426 143 20.2 0.73 19 2.08 7.9 414 139 105 21.4 0.71 20 2.16 8.3 436 149 23.2 0.74 19 2.22 8.6 449 154 23.9 0.77 19 2.24 8.7 454 155 71 24.1 0.59 14 2.22 8.6 449 154 23.4 0.57 15 2.20 8.5 445 152 21.6 0.55 15 2.15 8.3 431 148 17.4 1.00 23 2.06 8.0 406 125 18.9 1.00 21 2.11 8.3 419 129 19.4 1.00 20 2.13 8.3 423 130 59 19.1 1.00 19 2.11 8.3 419 129 18.5 1.00 21 2.09 8.2 415 127 17.1 0.97 21 2.04 8.0 402 124 17.7 0.98 22 2.10 8.2 437 133 19.2 1.00 22 2.15 8.5 451 137 19.8 1.00 20 2.17 8.5 455 138 63 19.5 1.00 20 2.15 8.5 451 137 18.9 0.94 20 2.14 8.4 446 136 17.5 0.91 21 2.09 8.2 433 131 18.6 0.88 21 2.17 8.5 462 145 20.1 0.91 21 2.22 8.8 476 149 20.7 0.96 20 2.24 8.8 481 151 67 20.8 0.80 17 2.22 8.8 476 149 20.2 0.76 18 2.20 8.7 471 148 18.7 0.74 18 2.15 8.4 457 144 115 19.8 0.71 18 2.24 8.8 481 154 21.5 0.74 18 2.29 9.1 496 159 22.1 0.78 17 2.31 9.2 501 161 71 22.3 0.60 13 2.29 9.1 496 159 21.6 0.57 14 2.27 9.0 491 158 20.0 0.55 14 2.22 8.7 477 153 COOLING OPERATION COOLING PERFORMANCE DATA GSX130241A* 15 16 75 70 IDB* 28.0 0.59 15 2.01 7.1 255 112 25.8 0.57 15 1.97 6.9 248 109 29.1 0.76 17 2.04 7.2 261 115 28.3 0.72 18 2.03 7.1 258 114 26.1 0.69 18 1.98 7.0 250 110 MBh 27.0 S/T 0.71 Delta T 17 KW 1.97 AMPS 6.9 HI PR 237 LO PR 106 MBh 24.9 S/T 0.68 Delta T 17 KW 1.93 AMPS 6.7 HI PR 230 LO PR 103 MBh 28.3 S/T 0.84 Delta T 19 KW 2.00 AMPS 7.0 HI PR 242 LO PR 108 MBh 27.5 S/T 0.81 Delta T 19 KW 1.99 AMPS 7.0 HI PR 240 LO PR 107 MBh 25.4 S/T 0.78 Delta T 20 KW 1.94 AMPS 6.8 HI PR 233 LO PR 104 1050 919 1181 1050 919 67 28.3 0.53 15 2.04 7.2 264 120 30.6 0.55 15 2.09 7.4 272 124 31.5 0.57 14 2.10 7.5 275 125 28.3 0.40 11 2.02 7.1 262 119 30.7 0.41 11 2.07 7.3 270 123 31.6 0.43 11 2.08 7.4 272 124 * Entering Indoor Dry Bulb Temperature 1181 63 28.8 0.62 14 2.03 7.1 258 114 59 MBh 27.8 S/T 0.74 Delta T 16 KW 1.99 AMPS 7.0 HI PR 240 LO PR 107 Airflow 65 30.3 0.34 10 2.10 7.5 276 128 32.9 0.35 10 2.15 7.7 284 132 33.9 0.37 10 2.16 7.7 287 133 - - - 71 59 24.8 0.81 20 2.08 7.3 261 109 26.8 0.84 20 2.13 7.6 269 113 27.6 0.88 19 2.14 7.6 272 114 24.4 0.71 17 2.06 7.3 258 108 26.4 0.73 17 2.11 7.5 266 112 27.2 0.77 16 2.13 7.6 269 113 63 67 27.6 0.55 15 2.19 7.8 297 127 29.9 0.57 15 2.24 8.0 306 131 30.8 0.59 14 2.25 8.1 309 132 27.7 0.41 11 2.17 7.7 294 126 30.0 0.43 11 2.22 7.9 303 130 30.9 0.45 11 2.24 8.0 306 131 29.6 0.35 10 2.25 8.1 309 135 32.1 0.36 10 2.31 8.3 319 140 33.1 0.38 10 2.32 8.4 322 141 - - - 71 59 24.2 0.83 20 2.20 8.0 297 114 26.2 0.86 20 2.25 8.2 306 117 27.0 0.90 19 2.27 8.3 309 118 23.8 0.73 17 2.19 7.9 294 113 25.8 0.75 17 2.24 8.1 303 116 26.5 0.79 16 2.25 8.2 306 117 24.9 0.74 18 2.25 8.2 319 121 27.0 0.77 18 2.30 8.4 329 125 27.8 0.80 17 2.32 8.5 333 126 24.6 0.61 15 2.23 8.1 316 120 26.7 0.63 15 2.28 8.3 326 123 27.5 0.66 14 2.30 8.4 329 125 26.9 0.56 15 2.32 8.5 337 132 29.2 0.58 15 2.37 8.7 348 136 30.1 0.61 14 2.39 8.8 351 138 27.0 0.42 11 2.30 8.4 334 131 29.3 0.44 11 2.35 8.6 344 135 30.1 0.46 11 2.37 8.7 348 136 28.9 0.36 10 2.39 8.8 352 141 31.3 0.37 10 2.45 9.0 363 145 32.3 0.39 10 2.47 9.1 366 146 - - - 23.6 0.85 20 2.31 8.5 338 119 25.6 0.88 20 2.37 8.8 348 123 26.3 0.93 19 2.38 8.9 352 124 23.2 0.75 17 2.29 8.5 335 118 25.1 0.78 17 2.35 8.7 345 122 25.9 0.82 16 2.37 8.8 348 123 24.3 0.76 19 2.36 8.8 364 127 26.3 0.79 18 2.41 9.0 375 131 27.1 0.83 17 2.43 9.1 379 132 24.0 0.63 15 2.34 8.7 360 126 26.1 0.65 15 2.40 8.9 371 130 26.8 0.68 14 2.41 9.0 375 131 26.3 0.58 15 2.43 9.1 384 139 28.5 0.60 15 2.49 9.3 396 143 29.3 0.63 14 2.51 9.4 400 144 26.3 0.43 11 2.41 9.0 380 137 28.5 0.45 11 2.47 9.2 392 142 29.4 0.47 11 2.49 9.3 396 143 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 NOTE: Shaded area is ACCA (TVA) conditions 25.5 0.72 18 2.12 7.5 281 116 27.6 0.75 18 2.17 7.7 290 120 28.5 0.78 17 2.19 7.8 292 121 25.2 0.59 15 2.11 7.5 278 115 27.4 0.61 15 2.16 7.7 287 119 28.2 0.64 14 2.17 7.7 289 120 75 MODEL: GSX130301A* / CA*F3030*6** / ZP24K5E-PFV 28.2 0.37 10 2.51 9.4 401 148 30.6 0.38 10 2.57 9.7 413 152 31.5 0.40 10 2.59 9.8 417 154 - - - 71 EXPANDED PERFORMANCE DATA 59 22.4 0.88 20 2.40 9.1 380 125 24.3 0.92 20 2.46 9.4 392 129 25.0 0.96 19 2.48 9.5 396 130 22.0 0.78 17 2.38 9.0 376 124 23.9 0.81 17 2.44 9.3 388 128 24.6 0.85 16 2.46 9.4 392 129 63 23.1 0.79 18 2.45 9.3 409 133 25.0 0.82 18 2.51 9.6 422 137 25.8 0.86 17 2.53 9.7 426 139 22.8 0.65 15 2.43 9.2 405 132 24.7 0.67 15 2.49 9.5 418 136 25.5 0.71 14 2.51 9.6 422 137 67 25.0 0.60 15 2.53 9.6 432 145 27.1 0.62 15 2.59 9.9 446 150 27.9 0.65 14 2.61 10.0 450 151 25.0 0.45 11 2.51 9.6 428 144 27.1 0.47 11 2.57 9.8 441 148 27.9 0.49 11 2.59 9.9 445 150 105 26.8 0.39 10 2.61 10.0 451 155 29.0 0.40 10 2.67 10.3 465 160 29.9 0.42 10 2.70 10.4 469 161 - - - 71 59 20.8 0.89 19 2.48 9.6 420 130 22.5 0.93 18 2.54 9.9 433 134 23.2 0.97 17 2.56 10.0 437 135 20.4 0.78 16 2.46 9.6 416 128 22.1 0.81 16 2.52 9.8 429 132 22.8 0.85 15 2.54 9.9 433 133 63 21.4 0.80 17 2.53 9.9 452 138 23.2 0.83 17 2.60 10.2 466 142 23.9 0.87 16 2.62 10.3 471 143 21.2 0.66 14 2.51 9.8 448 136 22.9 0.68 14 2.57 10.1 461 141 23.6 0.71 13 2.60 10.2 466 142 67 23.1 0.60 14 2.61 10.2 477 150 25.1 0.63 14 2.68 10.5 492 155 25.8 0.66 13 2.70 10.6 497 157 23.2 0.45 11 2.59 10.1 473 149 25.1 0.47 10 2.66 10.4 487 154 25.9 0.49 10 2.68 10.5 492 155 115 24.8 0.39 10 2.70 10.6 498 160 26.9 0.40 9 2.76 10.9 513 165 27.7 0.42 9 2.79 11.0 519 167 - - - 71 COOLING OPERATION COOLING PERFORMANCE DATA GSX130301A* 85 80 IDB* 28.6 0.83 21 2.04 7.2 261 115 26.4 0.80 21 1.99 7.0 253 111 29.9 0.94 22 2.07 7.3 266 117 29.0 0.89 23 2.06 7.3 263 116 26.8 0.86 23 2.01 7.1 255 112 MBh 28.0 S/T 0.88 Delta T 22 KW 2.00 AMPS 7.0 HI PR 242 LO PR 108 MBh 25.8 S/T 0.85 Delta T 22 KW 1.96 AMPS 6.9 HI PR 235 LO PR 105 MBh 29.3 S/T 0.97 Delta T 22 KW 2.03 AMPS 7.2 HI PR 247 LO PR 110 MBh 28.5 S/T 0.93 Delta T 23 KW 2.02 AMPS 7.1 HI PR 245 LO PR 109 MBh 26.3 S/T 0.89 Delta T 23 KW 1.97 AMPS 6.9 HI PR 237 LO PR 106 1050 919 1181 1050 919 28.0 0.78 22 2.07 7.3 270 123 30.4 0.81 21 2.12 7.5 278 127 31.3 0.85 21 2.13 7.6 281 128 28.2 0.65 18 2.05 7.2 267 122 30.5 0.67 18 2.10 7.5 275 125 67 31.4 0.71 17 2.12 7.5 278 127 * Entering Indoor Dry Bulb Temperature 1181 63 29.4 0.87 20 2.06 7.3 263 116 59 MBh 28.8 S/T 0.93 Delta T 21 KW 2.02 AMPS 7.1 HI PR 245 LO PR 109 Airflow 65 29.9 0.63 19 2.13 7.6 281 131 32.4 0.65 19 2.18 7.8 290 135 33.4 0.69 18 2.20 7.9 293 136 30.1 0.49 15 2.11 7.5 278 129 32.6 0.50 14 2.16 7.7 287 133 71 33.6 0.53 14 2.18 7.8 290 135 25.7 0.93 24 2.11 7.5 266 112 27.8 0.96 23 2.16 7.7 274 115 28.6 1.00 22 2.18 7.8 277 116 25.2 0.88 22 2.10 7.4 264 111 27.3 0.92 22 2.15 7.6 272 114 59 28.1 0.96 21 2.16 7.7 274 115 27.4 0.81 22 2.22 7.9 303 130 29.7 0.84 22 2.27 8.1 312 134 30.6 0.88 21 2.29 8.2 315 135 27.5 0.67 19 2.20 7.8 300 128 29.8 0.70 18 2.25 8.1 309 132 67 30.7 0.73 18 2.27 8.1 312 134 29.2 0.65 19 2.29 8.2 316 138 31.7 0.68 19 2.34 8.5 325 142 32.6 0.71 18 2.36 8.5 329 144 29.4 0.50 15 2.27 8.1 312 137 31.9 0.52 15 2.32 8.4 322 141 71 32.8 0.55 14 2.34 8.5 325 142 25.0 0.95 24 2.24 8.1 303 116 27.1 0.98 23 2.29 8.4 312 120 27.9 1.00 22 2.31 8.4 315 121 24.6 0.91 22 2.22 8.1 300 115 26.7 0.94 22 2.27 8.3 309 118 59 27.5 1.00 21 2.29 8.4 312 120 25.5 0.92 23 2.28 8.3 326 123 27.7 0.95 23 2.34 8.6 336 127 28.5 1.00 22 2.36 8.7 339 129 25.1 0.85 21 2.26 8.3 323 122 27.2 0.88 21 2.32 8.5 333 126 26.7 0.83 22 2.35 8.6 344 135 29.0 0.86 22 2.41 8.9 355 139 29.8 0.90 21 2.43 8.9 358 140 26.9 0.69 19 2.33 8.5 341 133 29.1 0.72 18 2.39 8.8 351 138 28.5 0.67 19 2.43 8.9 359 144 30.9 0.70 19 2.48 9.2 370 148 31.8 0.73 18 2.50 9.3 374 149 28.7 0.52 15 2.41 8.9 355 142 31.1 0.54 15 2.47 9.1 366 147 24.4 0.98 24 2.35 8.7 345 122 26.5 1.00 23 2.40 9.0 356 126 27.3 1.00 21 2.42 9.0 359 127 24.0 0.93 22 2.33 8.6 341 121 26.0 0.97 22 2.38 8.9 352 124 24.9 0.95 24 2.40 8.9 371 130 27.0 0.98 23 2.45 9.2 383 134 27.8 1.00 22 2.47 9.3 386 135 24.5 0.88 22 2.38 8.8 367 128 26.6 0.91 21 2.43 9.1 379 132 26.1 0.85 22 2.47 9.2 392 142 28.3 0.89 22 2.53 9.5 404 146 29.1 0.93 21 2.55 9.6 408 147 28.4 0.74 18 2.51 9.4 400 145 26.2 0.71 19 2.45 9.1 388 140 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 28.1 30.0 32.1 26.8 27.4 29.3 0.92 0.75 0.56 1.00 0.95 0.78 20 18 14 21 20 18 2.34 2.41 2.48 2.40 2.45 2.53 8.6 8.9 9.2 9.0 9.2 9.5 336 355 370 356 383 404 127 139 148 126 134 146 NOTE: Shaded area is AHRI Rating Conditions 26.1 0.89 23 2.15 7.7 286 119 28.3 0.93 23 2.21 7.9 295 122 29.2 0.97 22 2.22 8.0 298 124 25.8 0.83 21 2.14 7.6 284 118 27.9 0.86 21 2.19 7.8 292 121 63 28.7 0.90 20 2.21 7.9 295 122 75 MODEL: GSX130301AA / CA*F3030*6** / ZP24K5E-PFV 27.8 0.69 19 2.55 9.6 409 151 30.1 0.72 19 2.61 9.9 421 155 31.1 0.75 18 2.63 9.9 426 157 28.0 0.53 15 2.53 9.5 405 149 30.4 0.55 15 2.59 9.8 417 154 71 31.3 0.58 14 2.61 9.9 421 155 EXPANDED PERFORMANCE DATA 23.2 1.00 23 2.44 9.3 388 128 25.1 1.00 22 2.50 9.5 400 132 25.9 1.00 20 2.52 9.6 404 133 22.8 0.97 22 2.42 9.2 384 126 24.7 1.00 22 2.48 9.5 396 130 59 25.5 1.00 20 2.50 9.5 400 132 23.7 0.98 23 2.49 9.5 417 136 25.6 1.00 22 2.55 9.8 430 140 26.4 1.00 21 2.57 9.9 435 142 23.3 0.91 21 2.47 9.4 413 135 25.3 0.94 21 2.53 9.7 426 139 63 26.0 1.00 20 2.55 9.8 430 140 24.8 0.89 22 2.57 9.8 441 148 26.8 0.92 22 2.63 10.1 455 153 27.7 0.96 21 2.65 10.2 459 154 24.9 0.74 18 2.55 9.7 437 147 27.0 0.77 18 2.61 10.0 450 151 67 27.8 0.81 17 2.63 10.1 455 153 105 26.4 0.72 19 2.65 10.2 460 158 28.6 0.75 19 2.72 10.5 474 163 29.5 0.78 18 2.74 10.6 479 165 26.6 0.55 15 2.63 10.1 455 156 28.8 0.57 14 2.70 10.4 469 161 71 29.7 0.60 14 2.72 10.5 474 163 21.5 1.00 22 2.52 9.8 429 132 23.3 1.00 20 2.58 10.1 442 136 24.0 1.00 19 2.60 10.2 446 138 21.1 0.98 21 2.50 9.7 424 131 22.9 1.00 20 2.56 10.0 438 135 59 23.6 1.00 18 2.58 10.1 442 136 21.9 0.99 22 2.57 10.1 461 141 23.7 1.00 21 2.64 10.4 476 145 24.5 1.00 19 2.66 10.5 480 146 21.6 0.92 20 2.55 10.0 457 139 23.4 0.95 19 2.62 10.3 471 143 63 24.1 1.00 19 2.64 10.4 476 145 23.0 0.89 21 2.66 10.4 487 153 24.9 0.93 20 2.72 10.7 502 158 25.6 0.97 19 2.74 10.8 507 160 23.1 0.75 17 2.63 10.3 482 152 25.0 0.77 17 2.70 10.6 497 157 67 25.7 0.81 16 2.72 10.7 502 158 115 24.5 0.72 18 2.74 10.8 508 163 26.5 0.75 17 2.81 11.1 524 168 27.3 0.79 17 2.83 11.2 529 170 24.7 0.56 14 2.72 10.7 503 162 26.7 0.58 14 2.79 11.0 519 167 71 27.5 0.61 13 2.81 11.1 524 168 COOLING OPERATION COOLING PERFORMANCE DATA GSX130301A* 17 18 75 70 IDB* 34.5 0.58 15 2.48 9.0 249 111 31.9 0.56 15 2.43 8.7 242 108 35.9 0.74 18 2.52 9.1 254 114 34.9 0.70 19 2.50 9.0 252 112 32.2 0.68 19 2.45 8.8 244 109 MBh 33.3 S/T 0.69 Delta T 18 KW 2.43 AMPS 8.7 HI PR 231 LO PR 105 MBh 30.7 S/T 0.67 Delta T 18 KW 2.38 AMPS 8.5 HI PR 224 LO PR 101 MBh 34.9 S/T 0.82 Delta T 20 KW 2.47 AMPS 8.9 HI PR 236 LO PR 107 MBh 33.9 S/T 0.78 Delta T 20 KW 2.45 AMPS 8.8 HI PR 234 LO PR 106 MBh 31.3 S/T 0.76 Delta T 21 KW 2.40 AMPS 8.6 HI PR 227 LO PR 103 1200 1050 1350 1200 1050 67 34.8 0.51 16 2.52 9.1 258 119 37.7 0.53 15 2.58 9.3 266 123 38.9 0.56 15 2.60 9.4 268 124 34.9 0.38 12 2.50 9.0 255 118 37.8 0.40 12 2.56 9.3 263 122 38.9 0.42 11 2.58 9.3 266 123 * Entering Indoor Dry Bulb Temperature 1350 63 35.5 0.60 15 2.50 9.0 252 112 59 MBh 34.3 S/T 0.72 Delta T 17 KW 2.45 AMPS 8.8 HI PR 234 LO PR 106 Airflow 65 37.4 0.33 11 2.60 9.4 269 127 40.5 0.34 11 2.66 9.7 277 131 41.7 0.36 10 2.68 9.8 280 132 - - - 71 59 30.5 0.78 21 2.57 9.3 254 108 33.1 0.81 21 2.63 9.6 262 112 34.1 0.85 20 2.66 9.6 265 113 30.0 0.69 18 2.55 9.2 252 107 32.5 0.71 18 2.61 9.5 260 111 33.5 0.75 17 2.63 9.6 262 112 63 67 34.0 0.53 16 2.71 9.8 289 126 36.9 0.55 16 2.77 10.1 298 130 38.0 0.58 15 2.79 10.2 301 131 34.1 0.40 12 2.69 9.7 286 125 36.9 0.41 12 2.75 10.0 295 128 38.0 0.43 11 2.77 10.1 298 130 36.5 0.34 11 2.79 10.2 302 134 39.6 0.35 11 2.86 10.5 311 138 40.7 0.37 10 2.88 10.6 314 139 - - - 71 59 29.8 0.80 21 2.73 10.1 289 113 32.3 0.83 21 2.79 10.4 298 116 33.3 0.87 20 2.82 10.5 301 117 29.3 0.71 18 2.71 10.0 286 111 31.7 0.73 18 2.77 10.3 295 115 32.7 0.77 17 2.79 10.4 298 116 30.7 0.72 19 2.79 10.4 311 120 33.2 0.75 19 2.85 10.7 321 123 34.2 0.78 18 2.88 10.8 324 125 30.4 0.59 16 2.76 10.3 308 119 32.9 0.61 15 2.83 10.6 318 122 33.9 0.64 15 2.85 10.7 321 123 33.2 0.54 16 2.87 10.7 329 131 36.0 0.56 16 2.94 11.0 339 135 37.1 0.59 15 2.97 11.1 342 136 33.3 0.41 12 2.85 10.6 326 129 36.1 0.42 12 2.92 10.9 336 133 37.1 0.44 11 2.94 11.0 339 135 35.6 0.35 11 2.96 11.1 343 139 38.6 0.36 11 3.04 11.5 354 144 39.8 0.38 10 3.06 11.6 357 145 - - - 29.1 0.83 21 2.87 10.8 330 118 31.5 0.86 21 2.94 11.1 340 122 32.4 0.90 20 2.96 11.3 343 123 28.6 0.73 18 2.84 10.7 326 117 31.0 0.76 18 2.91 11.0 336 121 31.9 0.79 17 2.94 11.1 340 122 29.9 0.74 19 2.93 11.1 355 126 32.4 0.77 19 3.00 11.4 366 130 33.4 0.81 18 3.02 11.5 369 131 29.6 0.61 16 2.90 11.0 351 125 32.1 0.63 16 2.97 11.3 362 128 33.1 0.66 15 3.00 11.4 366 130 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 NOTE: Shaded area is ACCA (TVA) conditions 31.4 0.70 19 2.63 9.5 274 115 34.1 0.73 19 2.69 9.8 282 119 35.1 0.76 18 2.71 9.9 285 120 31.1 0.58 16 2.61 9.4 271 114 33.7 0.60 15 2.67 9.7 279 118 34.7 0.63 15 2.69 9.8 282 119 75 MODEL: GSX130361A* / CA*F4860*6** / ZP31K5E-PFV 32.4 0.56 16 3.02 11.5 375 137 35.1 0.58 16 3.09 11.8 386 142 36.2 0.61 15 3.12 11.9 390 143 32.5 0.42 12 2.99 11.4 371 136 35.2 0.44 12 3.07 11.7 382 140 36.2 0.46 11 3.09 11.8 386 142 67 34.8 0.36 11 3.12 11.9 391 146 37.7 0.37 11 3.20 12.3 403 151 38.8 0.39 10 3.22 12.4 407 152 - - - 71 EXPANDED PERFORMANCE DATA 59 27.6 0.86 21 2.98 11.5 371 124 29.9 0.89 20 3.06 11.9 382 128 30.8 0.94 20 3.08 12.0 386 129 27.2 0.76 18 2.96 11.4 367 123 29.4 0.79 18 3.03 11.8 378 126 30.3 0.82 17 3.06 11.9 382 128 63 28.4 0.77 19 3.05 11.8 399 132 30.8 0.80 19 3.12 12.2 411 136 31.7 0.84 18 3.15 12.3 415 137 28.2 0.63 16 3.02 11.7 395 130 30.5 0.66 15 3.10 12.1 407 135 31.4 0.69 15 3.12 12.2 411 136 67 30.8 0.58 16 3.14 12.2 421 144 33.3 0.60 15 3.22 12.6 434 148 34.4 0.63 15 3.25 12.7 439 150 30.8 0.44 12 3.12 12.1 417 142 33.4 0.45 12 3.20 12.5 430 147 34.4 0.48 11 3.22 12.6 434 148 105 33.0 0.37 11 3.25 12.7 439 153 35.8 0.39 11 3.33 13.1 453 158 36.9 0.41 10 3.36 13.2 458 160 - - - 71 59 25.6 0.87 19 3.08 12.2 410 128 27.7 0.90 19 3.16 12.6 422 132 28.6 0.94 18 3.19 12.7 427 133 25.2 0.76 17 3.06 12.1 406 127 27.3 0.79 17 3.13 12.5 418 131 28.1 0.83 16 3.16 12.6 422 132 63 26.3 0.78 18 3.15 12.6 441 136 28.5 0.81 18 3.23 12.9 454 141 29.4 0.84 17 3.26 13.0 459 142 26.1 0.64 15 3.12 12.4 436 135 28.3 0.66 14 3.20 12.8 450 139 29.1 0.69 14 3.23 12.9 454 141 67 28.5 0.59 15 3.25 13.0 466 149 30.9 0.61 14 3.33 13.4 480 153 31.8 0.64 14 3.36 13.5 485 155 28.6 0.44 11 3.22 12.9 461 147 31.0 0.46 11 3.31 13.2 475 152 31.9 0.48 10 3.33 13.4 480 153 115 30.6 0.38 10 3.36 13.5 486 159 33.2 0.39 10 3.44 13.9 501 163 34.2 0.41 10 3.47 14.0 506 165 - - - 71 COOLING OPERATION COOLING PERFORMANCE DATA GSX130361A* 85 80 IDB* 34.5 0.86 23 2.47 8.9 236 107 31.8 0.83 23 2.42 8.7 229 104 36.1 0.95 23 2.51 9.1 241 109 35.1 0.90 24 2.49 9.0 238 108 32.4 0.87 25 2.43 8.7 231 105 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1200 1050 1350 1200 1050 33.0 0.84 24 2.48 9.0 249 111 35.7 0.87 24 2.54 9.2 257 115 36.8 0.91 23 2.56 9.3 259 116 32.5 0.78 22 2.46 8.9 246 110 35.2 0.81 22 2.52 9.1 254 114 63 36.3 0.85 21 2.54 9.2 257 115 34.6 0.76 23 2.56 9.3 263 121 37.4 0.79 23 2.62 9.5 271 125 38.6 0.82 22 2.64 9.6 274 126 34.7 0.63 19 2.54 9.2 260 120 37.6 0.66 19 2.60 9.4 268 124 67 38.8 0.69 18 2.62 9.5 271 125 * Entering Indoor Dry Bulb Temperature 1350 59 35.5 0.90 22 2.49 9.0 238 108 MBh S/T Delta T KW AMPS HI PR LO PR Airflow 65 36.9 0.61 20 2.64 9.6 274 129 39.9 0.64 19 2.70 9.9 283 133 41.1 0.67 19 2.72 10.0 285 135 37.1 0.47 15 2.62 9.5 271 128 40.2 0.49 15 2.68 9.8 280 132 71 41.4 0.51 15 2.70 9.9 283 133 31.6 0.90 25 2.61 9.5 260 110 34.3 0.93 25 2.68 9.7 268 114 35.3 0.98 24 2.70 9.8 270 115 31.1 0.86 23 2.59 9.4 257 109 33.7 0.89 23 2.66 9.6 265 113 59 34.7 0.93 22 2.68 9.7 268 114 33.8 0.78 23 2.75 10.0 295 128 36.6 0.81 23 2.82 10.3 304 132 37.7 0.85 22 2.84 10.4 307 134 33.9 0.66 19 2.73 9.9 292 127 36.8 0.68 19 2.79 10.2 301 131 67 37.9 0.71 18 2.82 10.3 304 132 36.0 0.64 20 2.84 10.4 308 137 39.0 0.66 20 2.91 10.7 317 141 40.2 0.69 19 2.93 10.8 320 142 36.3 0.49 16 2.81 10.3 305 135 39.3 0.51 15 2.88 10.6 314 140 71 40.5 0.53 15 2.91 10.7 317 141 30.9 0.92 25 2.77 10.3 295 115 33.4 0.96 25 2.84 10.6 304 118 34.4 1.00 23 2.86 10.7 307 120 30.3 0.88 23 2.75 10.2 292 114 32.9 0.91 23 2.82 10.5 301 117 59 33.8 0.96 22 2.84 10.6 304 118 31.5 0.89 25 2.83 10.6 318 122 34.1 0.92 24 2.90 10.9 328 126 35.1 0.97 23 2.92 11.0 331 127 31.0 0.83 22 2.81 10.5 315 121 33.6 0.86 22 2.88 10.8 324 125 32.9 0.80 23 2.92 10.9 335 133 35.7 0.83 23 2.99 11.2 346 137 36.8 0.87 22 3.02 11.4 349 139 33.1 0.67 20 2.90 10.8 332 132 35.9 0.70 19 2.97 11.1 342 136 35.1 0.65 20 3.01 11.3 350 142 38.1 0.68 20 3.09 11.7 361 146 39.2 0.71 19 3.11 11.8 364 148 35.4 0.50 16 2.99 11.2 346 141 38.4 0.52 15 3.06 11.6 357 145 30.1 0.95 25 2.91 11.0 336 121 32.6 0.99 25 2.98 11.4 347 124 33.6 1.00 23 3.01 11.5 350 126 29.6 0.91 24 2.89 10.9 333 119 32.1 0.94 23 2.96 11.3 343 123 30.7 0.92 25 2.97 11.3 362 128 33.3 0.95 24 3.05 11.6 373 132 34.2 1.00 23 3.07 11.8 377 134 30.2 0.85 23 2.95 11.2 358 127 32.8 0.88 22 3.02 11.5 369 131 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 34.6 37.0 39.5 33.0 33.7 0.90 0.73 0.55 1.00 0.93 21 18 15 22 21 2.90 2.99 3.09 2.98 3.05 10.9 11.2 11.7 11.4 11.6 328 346 361 347 373 126 137 146 124 132 NOTE: Shaded area is AHRI Rating Conditions 32.2 0.87 25 2.67 9.7 279 118 34.9 0.90 24 2.73 10.0 288 121 36.0 0.95 23 2.75 10.1 291 122 31.7 0.81 22 2.65 9.6 277 116 34.4 0.84 22 2.71 9.9 285 120 63 35.4 0.88 21 2.73 10.0 288 121 75 MODEL: GSX130361AA / CA*F4860*6** / ZP31K5E-PFV 32.1 0.83 23 3.07 11.7 382 140 34.8 0.86 23 3.15 12.0 394 144 35.9 0.90 22 3.17 12.2 398 146 35.0 0.72 19 3.12 11.9 390 143 32.3 0.69 20 3.04 11.6 378 139 67 36.1 0.75 19 3.15 12.0 394 144 34.3 0.67 20 3.17 12.2 399 149 37.2 0.70 20 3.25 12.5 411 154 38.3 0.73 19 3.27 12.6 415 155 34.5 0.52 16 3.14 12.0 395 148 37.4 0.54 15 3.22 12.4 407 152 71 38.5 0.56 15 3.25 12.5 411 154 EXPANDED PERFORMANCE DATA 28.6 0.99 25 3.03 11.8 378 126 31.0 1.00 24 3.11 12.1 390 130 31.9 1.00 22 3.13 12.2 394 132 28.1 0.94 23 3.01 11.7 375 125 30.5 0.98 23 3.08 12.0 386 129 59 31.4 1.00 21 3.11 12.1 390 130 29.2 0.95 24 3.10 12.1 407 134 31.6 0.99 24 3.17 12.4 420 139 32.5 1.00 22 3.20 12.5 424 140 28.7 0.89 22 3.07 11.9 403 133 31.1 0.92 22 3.15 12.3 415 137 63 32.1 0.96 21 3.17 12.4 420 139 30.5 0.86 23 3.20 12.5 430 147 33.1 0.89 23 3.28 12.8 443 151 34.1 0.94 22 3.30 13.0 448 153 30.7 0.72 19 3.17 12.4 426 145 33.3 0.75 19 3.25 12.7 439 150 67 34.2 0.78 18 3.28 12.8 443 151 105 32.6 0.70 20 3.30 13.0 448 156 35.3 0.73 20 3.38 13.3 462 161 36.4 0.76 19 3.41 13.5 467 163 32.8 0.54 15 3.27 12.8 444 155 35.5 0.56 15 3.36 13.2 458 160 71 36.6 0.59 15 3.38 13.3 462 161 26.5 1.00 23 3.13 12.5 418 131 28.7 1.00 22 3.21 12.8 431 135 29.6 1.00 20 3.24 13.0 435 136 26.0 0.95 22 3.11 12.4 414 129 28.2 0.99 21 3.19 12.7 427 133 59 29.1 1.00 20 3.21 12.8 431 135 27.0 0.96 23 3.20 12.8 450 139 29.3 1.00 22 3.28 13.2 464 143 30.1 1.00 21 3.31 13.3 468 145 26.6 0.89 21 3.18 12.7 445 138 28.8 0.93 20 3.26 13.1 459 142 63 29.7 0.97 20 3.28 13.2 464 143 28.3 0.87 22 3.30 13.2 475 152 30.6 0.90 21 3.39 13.6 490 157 31.6 0.94 20 3.42 13.8 495 158 28.4 0.73 18 3.28 13.1 470 150 30.8 0.75 18 3.36 13.5 485 155 67 31.7 0.79 17 3.39 13.6 490 157 115 30.2 0.71 19 3.41 13.8 495 162 32.7 0.73 18 3.50 14.2 511 167 33.7 0.77 18 3.53 14.3 516 168 30.4 0.54 14 3.39 13.6 490 160 32.9 0.56 14 3.47 14.0 506 165 71 33.9 0.59 14 3.50 14.2 511 167 COOLING OPERATION COOLING PERFORMANCE DATA GSX130361A* 19 20 75 70 IDB* 38.1 0.70 17 2.81 10.0 233 106 35.1 0.67 18 2.75 9.7 226 103 39.9 0.83 19 2.85 10.2 238 108 38.7 0.79 20 2.83 10.1 236 107 35.7 0.77 21 2.77 9.8 228 104 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1400 1225 1575 1400 1225 63 36.8 0.69 19 2.82 10.1 246 111 39.8 0.71 19 2.89 10.4 253 114 41.0 0.75 18 2.91 10.5 256 115 36.4 0.56 15 2.80 10.0 243 109 39.4 0.58 15 2.87 10.3 251 113 40.6 0.61 15 2.89 10.4 253 114 67 39.8 0.52 16 2.91 10.4 260 121 43.1 0.54 15 2.97 10.7 268 124 44.4 0.56 15 3.00 10.8 270 126 39.9 0.39 12 2.88 10.3 257 120 43.2 0.40 11 2.95 10.6 265 123 44.5 0.42 11 2.97 10.7 268 124 * Entering Indoor Dry Bulb Temperature 1575 MBh S/T Delta T KW AMPS HI PR LO PR 59 39.2 0.73 17 2.83 10.1 236 107 MBh S/T Delta T KW AMPS HI PR LO PR Airflow 65 42.7 0.33 11 2.99 10.8 271 129 46.3 0.35 11 3.06 11.2 279 133 47.7 0.36 10 3.09 11.3 282 134 - - - 71 59 34.9 0.79 21 2.97 10.7 256 110 37.8 0.82 20 3.04 11.0 264 113 38.9 0.86 20 3.06 11.1 267 114 34.3 0.70 18 2.94 10.6 254 109 37.2 0.72 18 3.01 10.9 262 112 38.3 0.76 17 3.03 11.0 264 113 63 67 38.9 0.54 16 3.12 11.3 291 128 42.1 0.56 15 3.19 11.7 300 131 43.4 0.58 15 3.21 11.8 303 133 39.0 0.40 12 3.09 11.2 288 126 42.2 0.42 12 3.17 11.5 297 130 43.5 0.44 11 3.19 11.7 300 131 41.7 0.35 11 3.21 11.8 304 136 45.2 0.36 11 3.29 12.1 313 140 46.6 0.38 10 3.31 12.2 316 141 - - - 71 59 34.1 0.81 21 3.14 11.6 292 114 36.9 0.84 20 3.22 12.0 301 118 38.0 0.89 20 3.24 12.1 304 119 33.5 0.72 18 3.12 11.5 289 113 36.3 0.74 18 3.19 11.9 298 116 37.4 0.78 17 3.21 12.0 301 118 35.1 0.73 19 3.20 11.9 314 121 38.0 0.76 19 3.28 12.3 323 125 39.1 0.79 18 3.31 12.4 327 126 34.7 0.60 16 3.18 11.8 311 120 37.6 0.62 15 3.26 12.2 320 124 38.7 0.65 15 3.28 12.3 323 125 38.0 0.55 16 3.30 12.4 331 133 41.1 0.57 15 3.38 12.7 342 137 42.4 0.60 15 3.41 12.8 345 138 38.0 0.41 12 3.28 12.2 328 131 41.2 0.43 12 3.36 12.6 338 135 42.4 0.45 11 3.38 12.7 342 137 40.7 0.35 11 3.41 12.8 346 141 44.1 0.37 11 3.49 13.2 356 146 45.5 0.39 10 3.52 13.3 360 147 - - - 33.2 0.84 21 3.29 12.5 332 120 36.0 0.87 21 3.37 12.9 342 124 37.1 0.91 20 3.40 13.0 346 125 32.7 0.74 18 3.27 12.4 329 119 35.4 0.77 18 3.35 12.7 339 122 36.5 0.80 17 3.37 12.8 342 124 37.1 0.43 12 3.44 13.1 374 138 41.3 0.62 15 3.58 13.8 393 145 40.1 0.59 16 3.55 13.6 389 144 37.0 0.57 16 3.47 13.2 377 139 38.2 0.82 18 3.47 13.3 372 133 37.1 0.78 19 3.44 13.2 368 131 34.2 0.75 19 3.36 12.8 357 128 40.2 0.44 12 3.52 13.5 385 142 41.4 0.47 11 3.55 13.6 389 144 33.9 0.62 16 3.34 12.7 354 126 36.7 0.64 15 3.42 13.1 365 130 37.8 0.67 15 3.44 13.2 368 131 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 NOTE: Shaded area is ACCA (TVA) conditions 35.9 0.71 19 3.03 10.9 276 117 38.9 0.74 19 3.10 11.3 284 120 40.1 0.77 18 3.12 11.4 287 122 35.6 0.58 16 3.00 10.8 273 116 38.5 0.61 15 3.07 11.2 282 119 39.7 0.63 15 3.10 11.3 284 120 75 MODEL: GSX130421A* / CA*F4860*6** / ZP34K5-PFV 39.7 0.37 11 3.58 13.8 394 148 43.1 0.38 11 3.66 14.2 406 153 44.4 0.40 10 3.69 14.3 410 154 - - - 71 EXPANDED PERFORMANCE DATA 59 31.6 0.87 21 3.43 13.3 374 126 34.2 0.90 20 3.51 13.7 385 130 35.2 0.95 20 3.54 13.8 389 131 31.0 0.77 18 3.40 13.2 370 124 33.6 0.80 18 3.48 13.6 381 128 34.6 0.83 17 3.51 13.7 385 130 63 32.5 0.78 19 3.50 13.7 402 134 35.2 0.81 19 3.58 14.1 415 138 36.3 0.85 18 3.61 14.2 419 139 32.2 0.64 15 3.47 13.5 398 132 34.9 0.66 15 3.55 13.9 410 136 35.9 0.70 15 3.58 14.1 414 138 67 35.2 0.59 16 3.61 14.1 425 146 38.1 0.61 15 3.70 14.6 438 150 39.3 0.64 15 3.73 14.7 442 152 35.2 0.44 12 3.58 14.0 420 144 38.2 0.46 12 3.67 14.4 433 149 39.3 0.48 11 3.69 14.6 438 150 105 37.8 0.38 11 3.72 14.7 443 155 40.9 0.39 11 3.81 15.1 457 160 42.1 0.41 10 3.84 15.3 461 162 - - - 71 59 29.2 0.88 19 3.54 14.1 413 130 31.7 0.91 19 3.62 14.6 426 134 32.6 0.96 18 3.65 14.7 430 135 28.8 0.77 17 3.51 14.0 409 129 31.2 0.80 16 3.60 14.4 421 133 32.1 0.84 16 3.62 14.6 425 134 63 30.1 0.79 18 3.61 14.5 444 138 32.6 0.82 17 3.70 14.9 458 143 33.6 0.86 17 3.73 15.1 463 144 29.8 0.65 14 3.58 14.4 440 137 32.3 0.67 14 3.67 14.8 453 141 33.3 0.70 14 3.70 14.9 458 143 67 32.6 0.60 15 3.73 15.0 469 151 35.3 0.62 14 3.82 15.5 484 156 36.4 0.65 14 3.85 15.6 488 157 32.7 0.45 11 3.70 14.9 464 149 35.4 0.46 11 3.79 15.3 479 154 36.4 0.49 10 3.82 15.5 484 156 115 35.0 0.38 10 3.85 15.6 489 161 37.9 0.40 10 3.94 16.1 504 166 39.0 0.42 9 3.98 16.2 509 167 - - - 71 COOLING OPERATION COOLING PERFORMANCE DATA GSX130421A* 85 80 IDB* 39.4 0.87 23 2.85 10.2 238 108 36.4 0.84 23 2.79 9.9 231 105 41.3 0.96 23 2.90 10.4 243 110 40.1 0.91 24 2.87 10.3 240 109 37.0 0.88 24 2.81 10.0 233 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1400 1225 1575 1400 1225 37.7 0.85 24 2.87 10.3 251 113 40.9 0.88 24 2.93 10.6 259 116 42.1 0.92 23 2.95 10.7 261 117 37.1 0.79 22 2.84 10.2 248 112 40.2 0.82 22 2.91 10.5 256 115 63 41.5 0.86 21 2.93 10.6 259 116 39.5 0.77 23 2.95 10.6 265 123 42.8 0.80 22 3.02 10.9 273 127 44.1 0.83 21 3.04 11.0 276 128 39.7 0.64 19 2.93 10.5 262 122 43.0 0.67 19 3.00 10.8 270 126 67 44.3 0.70 18 3.02 10.9 273 127 * Entering Indoor Dry Bulb Temperature 1575 59 40.6 0.91 22 2.87 10.3 240 109 MBh S/T Delta T KW AMPS HI PR LO PR Airflow 65 42.1 0.62 20 3.04 11.0 276 131 45.6 0.65 19 3.11 11.4 285 135 47.0 0.68 19 3.13 11.5 288 137 42.4 0.48 15 3.02 10.9 274 130 46.0 0.50 15 3.09 11.3 282 134 71 47.3 0.52 14 3.11 11.4 285 135 36.1 0.91 25 3.01 10.9 262 112 39.1 0.95 24 3.08 11.2 270 116 40.3 0.99 23 3.11 11.3 272 117 35.5 0.87 23 2.99 10.8 259 111 38.5 0.90 23 3.06 11.1 267 114 59 39.6 0.95 22 3.08 11.2 270 116 38.6 0.80 23 3.16 11.5 297 130 41.8 0.82 23 3.24 11.9 306 134 43.0 0.86 22 3.27 12.0 309 135 38.8 0.67 19 3.14 11.4 294 129 42.0 0.69 19 3.22 11.8 303 133 67 43.3 0.72 18 3.24 11.9 306 134 41.2 0.65 20 3.26 12.0 310 139 44.6 0.67 20 3.34 12.3 320 143 45.9 0.70 19 3.37 12.5 323 144 41.4 0.50 15 3.24 11.9 307 137 44.9 0.52 15 3.31 12.2 316 141 71 46.2 0.54 15 3.34 12.3 320 143 35.3 0.94 25 3.19 11.9 297 116 38.2 0.97 24 3.27 12.2 307 120 39.4 1.00 23 3.29 12.3 310 121 34.7 0.89 23 3.16 11.8 295 115 37.6 0.93 23 3.24 12.1 304 119 59 38.7 1.00 23 3.27 12.2 307 120 36.0 0.90 24 3.25 12.2 320 124 39.0 0.94 24 3.33 12.5 330 128 40.1 0.98 23 3.36 12.7 333 129 35.4 0.84 22 3.23 12.1 317 123 38.4 0.87 22 3.31 12.4 327 126 37.7 0.82 23 3.35 12.6 338 135 40.8 0.85 23 3.44 13.0 349 139 42.0 0.89 22 3.46 13.1 352 141 37.8 0.68 19 3.33 12.5 335 134 41.0 0.71 19 3.41 12.8 345 138 40.2 0.66 20 3.46 13.1 353 144 43.5 0.69 20 3.54 13.5 363 148 44.8 0.72 19 3.57 13.6 367 150 40.5 0.51 15 3.43 13.0 349 143 43.8 0.53 15 3.52 13.3 360 147 34.4 0.97 25 3.35 12.7 339 122 37.3 1.00 24 3.43 13.1 349 126 38.4 1.00 22 3.45 13.2 353 127 33.8 0.92 23 3.32 12.6 335 121 36.6 0.96 23 3.40 13.0 346 125 35.1 0.93 25 3.42 13.0 365 130 38.0 0.97 24 3.50 13.4 376 134 39.1 1.00 23 3.53 13.6 380 135 34.6 0.86 22 3.39 12.9 361 129 37.4 0.90 22 3.47 13.3 372 133 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 39.5 42.2 45.1 37.7 38.6 0.91 0.74 0.55 1.00 0.94 21 18 15 22 21 3.33 3.44 3.54 3.43 3.50 12.5 13.0 13.5 13.1 13.4 330 349 363 349 376 128 139 148 126 134 NOTE: Shaded area is AHRI Rating Conditions 36.8 0.88 24 3.07 11.2 281 119 39.9 0.91 24 3.14 11.5 290 123 41.1 0.96 23 3.17 11.6 293 124 36.3 0.82 22 3.05 11.0 279 118 39.3 0.85 22 3.12 11.4 287 122 63 40.5 0.89 21 3.14 11.5 290 123 75 MODEL: GSX130421AA / CA*F4860*6** / ZP34K5-PFV 36.7 0.84 23 3.52 13.5 385 142 39.8 0.87 23 3.61 13.9 397 146 41.0 0.92 22 3.64 14.0 401 148 40.0 0.73 19 3.58 13.8 393 145 36.9 0.70 20 3.49 13.4 381 141 67 41.2 0.77 18 3.61 13.9 397 146 39.2 0.68 20 3.63 14.0 402 151 42.5 0.71 20 3.72 14.5 414 156 43.7 0.74 19 3.75 14.6 418 158 39.5 0.53 16 3.61 13.9 398 150 42.8 0.55 15 3.69 14.3 410 154 71 44.0 0.57 15 3.72 14.5 414 156 EXPANDED PERFORMANCE DATA 32.7 1.00 25 3.48 13.6 381 128 35.4 1.00 23 3.56 14.0 393 132 36.5 1.00 21 3.59 14.1 397 133 32.1 0.96 23 3.45 13.4 377 127 34.8 0.99 23 3.54 13.8 389 131 59 35.9 1.00 21 3.56 14.0 393 132 33.3 0.97 24 3.55 13.9 410 136 36.1 1.00 24 3.64 14.3 423 141 37.2 1.00 22 3.67 14.5 427 142 32.8 0.90 22 3.53 13.8 406 135 35.6 0.93 22 3.61 14.2 419 139 63 36.6 1.00 21 3.64 14.3 423 141 34.9 0.87 23 3.66 14.4 433 149 37.8 0.91 22 3.76 14.8 447 153 38.9 0.95 22 3.79 15.0 451 155 35.1 0.73 19 3.64 14.3 429 147 38.0 0.76 19 3.73 14.7 442 152 67 39.1 0.79 18 3.76 14.8 447 153 105 37.2 0.71 20 3.78 15.0 452 159 40.3 0.74 19 3.88 15.4 466 163 41.5 0.77 19 3.91 15.6 470 165 37.5 0.55 15 3.75 14.8 447 157 40.6 0.57 15 3.85 15.3 461 162 71 41.8 0.59 15 3.88 15.4 466 163 30.3 1.00 23 3.59 14.4 421 133 32.8 1.00 22 3.68 14.8 434 137 33.8 1.00 20 3.71 15.0 439 138 29.8 0.97 22 3.57 14.3 417 131 32.2 1.00 21 3.65 14.7 430 135 59 33.2 1.00 19 3.68 14.8 434 137 30.9 0.98 23 3.67 14.8 453 141 33.4 1.00 22 3.76 15.2 467 145 34.4 1.00 20 3.79 15.4 472 147 30.4 0.91 21 3.64 14.6 449 140 32.9 0.94 20 3.73 15.1 463 144 63 33.9 1.00 20 3.76 15.2 467 145 32.3 0.88 21 3.79 15.3 479 154 35.0 0.91 21 3.88 15.8 493 159 36.1 0.96 20 3.91 15.9 498 160 32.5 0.74 18 3.76 15.2 474 152 35.2 0.76 18 3.85 15.6 488 157 67 36.3 0.80 17 3.88 15.8 493 159 115 34.5 0.71 19 3.91 15.9 499 164 37.4 0.74 18 4.01 16.4 515 169 38.5 0.78 17 4.04 16.5 520 171 34.7 0.55 14 3.88 15.8 494 162 37.6 0.57 14 3.98 16.2 510 167 71 38.8 0.60 14 4.01 16.4 515 169 COOLING OPERATION COOLING PERFORMANCE DATA GSX130421A* 21 22 75 70 IDB* 43.8 0.72 18 3.13 11.5 233 109 40.4 0.69 18 3.05 11.2 226 106 45.8 0.86 20 3.18 11.7 238 111 44.5 0.82 21 3.16 11.6 236 110 41.1 0.79 21 3.08 11.3 228 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1600 1400 1800 1600 1400 63 42.3 0.70 20 3.15 11.5 246 114 45.8 0.73 19 3.22 11.9 253 117 47.2 0.77 18 3.25 12.0 256 118 41.9 0.58 16 3.12 11.4 243 112 45.4 0.60 16 3.20 11.8 251 116 46.7 0.63 15 3.22 11.9 253 117 67 45.8 0.53 16 3.25 11.9 260 124 49.6 0.55 16 3.33 12.3 268 128 51.1 0.58 15 3.36 12.4 270 129 45.9 0.40 12 3.22 11.8 257 123 49.7 0.42 12 3.30 12.1 265 127 51.2 0.44 11 3.33 12.3 268 128 * Entering Indoor Dry Bulb Temperature 1800 MBh S/T Delta T KW AMPS HI PR LO PR 59 45.1 0.75 17 3.16 11.6 236 110 MBh S/T Delta T KW AMPS HI PR LO PR Airflow 65 49.1 0.34 11 3.35 12.4 271 132 53.2 0.36 11 3.44 12.7 279 136 54.8 0.37 10 3.47 12.9 282 138 - - - 71 59 40.1 0.82 22 3.32 12.2 256 113 43.5 0.85 21 3.40 12.5 264 116 44.8 0.89 20 3.43 12.7 267 118 39.5 0.72 19 3.29 12.1 254 112 42.7 0.74 18 3.38 12.4 262 115 44.0 0.78 18 3.40 12.5 264 116 63 67 44.7 0.55 16 3.50 12.9 291 131 48.4 0.57 16 3.59 13.3 300 135 49.9 0.60 15 3.62 13.4 303 136 44.8 0.42 12 3.47 12.8 288 130 48.5 0.43 12 3.56 13.2 297 134 50.0 0.45 12 3.59 13.3 300 135 48.0 0.36 11 3.62 13.4 304 140 52.0 0.37 11 3.71 13.8 313 144 53.6 0.39 11 3.75 13.9 316 145 - - - 71 59 39.2 0.84 22 3.53 13.3 292 117 42.4 0.87 21 3.62 13.7 301 121 43.7 0.91 20 3.65 13.8 304 122 38.5 0.74 19 3.50 13.1 289 116 41.7 0.76 18 3.59 13.5 298 120 43.0 0.80 18 3.62 13.7 301 121 40.3 0.75 20 3.61 13.6 314 125 43.7 0.78 19 3.71 14.0 323 129 45.0 0.81 19 3.74 14.1 327 130 39.9 0.61 16 3.58 13.5 311 124 43.2 0.64 16 3.67 13.9 320 127 44.5 0.67 15 3.70 14.0 323 129 43.7 0.57 16 3.73 14.1 331 136 47.3 0.59 16 3.83 14.5 342 140 48.7 0.62 15 3.86 14.6 345 142 43.7 0.43 12 3.70 13.9 328 135 47.4 0.44 12 3.80 14.3 338 139 48.8 0.46 12 3.83 14.5 342 140 46.8 0.36 11 3.86 14.6 346 145 50.8 0.38 11 3.96 15.0 356 150 52.3 0.40 11 3.99 15.2 360 151 - - - 38.2 0.86 22 3.72 14.2 332 123 41.4 0.90 21 3.82 14.6 342 127 42.6 0.94 20 3.85 14.8 346 128 37.6 0.76 19 3.69 14.1 329 122 40.7 0.79 18 3.79 14.5 339 126 41.9 0.83 18 3.82 14.6 342 127 39.3 0.77 20 3.80 14.6 357 131 42.6 0.80 20 3.90 15.0 368 135 43.9 0.84 19 3.94 15.1 372 136 38.9 0.63 16 3.77 14.4 354 130 42.2 0.66 16 3.87 14.8 365 134 43.5 0.69 15 3.90 15.0 368 135 42.6 0.58 16 3.93 15.1 377 143 46.1 0.61 16 4.04 15.5 389 148 47.5 0.64 15 4.07 15.6 393 149 42.7 0.44 12 3.90 14.9 374 142 46.2 0.46 12 4.00 15.4 385 146 47.6 0.48 12 4.03 15.5 389 147 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 NOTE: Shaded area is ACCA (TVA) conditions 41.3 0.73 20 3.39 12.5 276 120 44.8 0.76 19 3.48 12.9 284 124 46.1 0.79 19 3.51 13.0 287 125 40.9 0.60 16 3.37 12.4 273 119 44.3 0.62 16 3.45 12.7 282 123 45.6 0.65 15 3.48 12.9 284 124 75 MODEL: GSX13048-1A* / CA*F4860*6** / ZP39K5E-PFV 45.7 0.38 11 4.07 15.6 394 152 49.5 0.39 11 4.17 16.1 406 157 51.0 0.41 11 4.21 16.3 410 159 - - - 71 EXPANDED PERFORMANCE DATA 59 36.3 0.90 21 3.88 15.1 374 129 39.3 0.93 21 3.98 15.6 385 133 40.5 0.97 20 4.02 15.7 389 134 35.7 0.79 18 3.85 15.0 370 128 38.7 0.82 18 3.95 15.4 381 132 39.8 0.86 17 3.98 15.6 385 133 63 37.4 0.80 20 3.97 15.5 402 137 40.5 0.83 19 4.07 16.0 415 142 41.7 0.87 19 4.11 16.1 419 143 37.0 0.66 16 3.93 15.4 398 136 40.1 0.68 16 4.04 15.8 410 140 41.3 0.72 15 4.07 16.0 414 142 67 40.5 0.61 16 4.10 16.1 425 150 43.8 0.63 16 4.21 16.5 438 155 45.1 0.66 15 4.25 16.7 442 156 40.5 0.46 12 4.07 15.9 420 148 43.9 0.47 12 4.17 16.4 433 153 45.2 0.50 11 4.21 16.5 438 155 105 43.4 0.39 11 4.24 16.7 443 160 47.0 0.40 11 4.36 17.2 457 165 48.5 0.42 11 4.39 17.3 461 166 - - - 71 59 33.6 0.90 20 4.02 16.1 413 134 36.4 0.94 20 4.12 16.5 426 138 37.5 0.98 19 4.16 16.7 430 139 33.1 0.80 17 3.98 15.9 409 132 35.8 0.82 17 4.09 16.4 421 136 36.9 0.86 16 4.12 16.5 425 138 63 34.6 0.81 18 4.11 16.5 444 142 37.5 0.84 18 4.22 17.0 458 146 38.6 0.88 17 4.26 17.1 463 148 34.3 0.66 15 4.07 16.3 440 141 37.1 0.69 15 4.18 16.8 453 145 38.2 0.72 14 4.22 17.0 458 146 67 37.5 0.61 15 4.25 17.0 469 155 40.6 0.63 15 4.36 17.5 484 160 41.8 0.67 14 4.40 17.7 488 161 37.5 0.46 11 4.21 16.9 464 154 40.7 0.48 11 4.32 17.4 479 158 41.9 0.50 11 4.36 17.5 484 160 115 40.2 0.39 10 4.40 17.7 489 165 43.6 0.41 10 4.51 18.2 504 170 44.9 0.43 10 4.55 18.4 509 172 - - - 71 COOLING OPERATION COOLING PERFORMANCE DATA GSX130481A* 85 80 IDB* 41.8 0.86 24 3.10 11.4 231 108 47.5 0.98 24 3.23 11.9 243 113 46.1 0.94 25 3.21 11.8 240 112 42.5 0.91 25 3.13 11.5 233 109 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1400 1800 1600 1400 43.4 0.87 25 3.20 11.7 251 116 47.0 0.91 24 3.28 12.1 259 120 48.4 0.95 23 3.30 12.2 261 121 42.7 0.81 23 3.17 11.6 248 115 63 47.7 0.88 21 3.28 12.1 259 120 46.3 0.84 22 3.25 12.0 256 118 45.4 0.79 24 3.30 12.1 265 127 49.2 0.82 23 3.38 12.5 273 130 50.7 0.86 22 3.41 12.6 276 132 45.6 0.66 20 3.27 12.0 262 125 67 50.9 0.72 19 3.38 12.5 273 130 49.5 0.68 19 3.36 12.4 270 129 * Entering Indoor Dry Bulb Temperature 1600 1800 59 46.7 0.94 22 3.21 11.8 240 112 45.3 0.90 23 3.18 11.7 238 111 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR Airflow 65 48.5 0.64 20 3.41 12.6 276 135 52.5 0.66 20 3.50 13.0 285 139 54.1 0.70 19 3.53 13.1 288 140 48.8 0.49 16 3.38 12.5 274 133 71 54.4 0.54 15 3.50 13.0 285 139 52.9 0.51 16 3.47 12.9 282 138 41.5 0.94 26 3.38 12.4 262 115 45.0 0.97 25 3.46 12.8 270 119 46.4 1.00 24 3.49 12.9 272 120 40.8 0.90 24 3.35 12.3 259 114 59 45.6 1.00 23 3.46 12.8 270 119 44.2 0.93 24 3.43 12.7 267 118 44.4 0.82 24 3.56 13.2 297 134 48.1 0.85 23 3.65 13.5 306 138 49.5 0.89 22 3.69 13.7 309 139 44.6 0.68 20 3.53 13.0 294 132 67 49.7 0.74 19 3.65 13.5 306 138 48.3 0.71 20 3.62 13.4 303 136 47.3 0.66 21 3.68 13.7 310 142 51.3 0.69 20 3.78 14.1 320 147 52.8 0.72 19 3.81 14.2 323 148 47.7 0.51 16 3.65 13.5 307 141 71 53.2 0.56 15 3.78 14.1 320 147 51.6 0.53 16 3.75 13.9 316 145 40.6 0.96 26 3.59 13.5 297 120 43.9 1.00 25 3.69 13.9 307 123 45.3 1.00 23 3.72 14.0 310 125 39.9 0.92 24 3.56 13.4 295 118 59 44.5 1.00 23 3.69 13.9 307 123 43.2 0.95 24 3.66 13.8 304 122 41.3 0.93 25 3.67 13.9 320 127 44.8 0.96 25 3.77 14.3 330 131 46.1 1.00 24 3.80 14.4 333 133 40.7 0.86 23 3.64 13.7 317 126 43.3 0.84 24 3.79 14.3 338 139 46.9 0.87 23 3.89 14.8 349 143 48.3 0.91 22 3.93 14.9 352 145 43.5 0.70 20 3.76 14.2 335 138 46.2 0.68 21 3.92 14.9 353 148 50.1 0.71 20 4.03 15.3 363 153 51.6 0.74 19 4.06 15.5 367 154 46.5 0.52 16 3.89 14.7 349 147 39.6 0.99 26 3.78 14.5 339 126 42.9 1.00 25 3.88 14.9 349 130 44.2 1.00 23 3.92 15.0 353 131 38.9 0.95 24 3.75 14.3 335 124 40.3 0.96 25 3.87 14.8 365 134 43.7 0.99 25 3.97 15.3 376 138 45.0 1.00 23 4.01 15.4 380 139 39.7 0.89 23 3.84 14.7 361 132 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 45.5 48.6 51.9 43.4 44.3 0.94 0.76 0.57 1.00 0.97 22 19 15 22 22 3.77 3.89 4.03 3.88 3.97 14.3 14.8 15.3 14.9 15.3 330 349 363 349 376 131 143 153 130 138 44.1 47.2 50.4 42.1 43.1 0.89 0.73 0.54 0.98 0.92 23 20 16 24 23 3.74 3.86 3.99 3.85 3.94 14.1 14.6 15.2 14.8 15.1 327 345 360 346 372 130 142 151 128 136 NOTE: Shaded area is AHRI Rating Conditions 42.4 0.91 25 3.45 12.7 281 122 45.9 0.94 25 3.54 13.1 290 126 47.3 0.98 24 3.57 13.2 293 128 41.7 0.84 23 3.42 12.6 279 121 63 46.6 0.91 22 3.54 13.1 290 126 45.2 0.87 23 3.51 13.0 287 125 75 MODEL: GSX13048-1AA / CA*F4860*6** / ZP39K5E-PFV 42.2 0.86 24 4.00 15.3 385 146 45.8 0.90 24 4.10 15.8 397 150 47.1 0.94 23 4.14 15.9 401 152 46.0 0.75 20 4.07 15.7 393 149 42.5 0.72 20 3.97 15.2 381 145 67 47.4 0.79 19 4.10 15.8 397 150 45.1 0.70 21 4.14 15.9 402 155 48.8 0.73 20 4.25 16.4 414 160 50.3 0.76 20 4.28 16.6 418 162 45.4 0.54 16 4.10 15.8 398 154 71 50.6 0.59 15 4.25 16.4 414 160 49.2 0.56 16 4.21 16.3 410 159 EXPANDED PERFORMANCE DATA 37.6 1.00 25 3.95 15.4 381 132 40.7 1.00 23 4.05 15.9 393 136 42.0 1.00 21 4.09 16.0 397 137 36.9 0.98 24 3.91 15.3 377 130 59 41.2 1.00 21 4.05 15.9 393 136 40.0 1.00 23 4.02 15.7 389 134 38.3 0.99 25 4.04 15.8 410 140 41.5 1.00 24 4.14 16.3 423 144 42.8 1.00 22 4.18 16.4 427 146 37.8 0.92 23 4.00 15.7 406 139 63 42.1 1.00 22 4.14 16.3 423 144 40.9 0.96 22 4.11 16.1 419 143 40.1 0.90 24 4.17 16.4 433 153 43.5 0.93 23 4.28 16.8 447 158 44.8 0.98 22 4.32 17.0 451 159 40.3 0.75 20 4.14 16.2 429 151 67 45.0 0.82 19 4.28 16.8 447 158 43.7 0.78 20 4.25 16.7 442 156 105 42.8 0.73 20 4.32 17.0 452 163 46.4 0.76 20 4.43 17.5 466 168 47.8 0.79 19 4.47 17.7 470 170 43.1 0.56 16 4.28 16.8 447 161 71 48.1 0.61 15 4.43 17.5 466 168 46.7 0.58 16 4.39 17.3 461 166 34.8 1.00 23 4.09 16.4 421 136 37.7 1.00 22 4.20 16.9 434 140 38.9 1.00 20 4.23 17.0 439 142 34.2 0.99 22 4.05 16.2 417 135 59 38.2 1.00 20 4.20 16.9 434 140 37.1 1.00 21 4.16 16.7 430 139 35.5 1.00 23 4.18 16.8 453 145 38.5 1.00 22 4.29 17.3 467 149 39.6 1.00 20 4.33 17.4 472 151 35.0 0.93 21 4.15 16.6 449 144 63 39.0 1.00 20 4.29 17.3 467 149 37.9 0.96 21 4.26 17.1 463 148 37.2 0.91 22 4.32 17.4 479 158 40.3 0.94 22 4.44 17.9 493 163 41.5 0.98 21 4.48 18.0 498 165 37.4 0.76 19 4.29 17.2 474 157 67 41.7 0.82 18 4.44 17.9 493 163 40.5 0.78 18 4.40 17.7 488 162 115 39.7 0.73 19 4.47 18.0 499 169 43.0 0.76 19 4.59 18.6 515 174 44.3 0.80 18 4.63 18.8 520 175 39.9 0.57 15 4.43 17.9 494 167 71 44.6 0.62 14 4.59 18.6 515 174 43.3 0.59 15 4.55 18.4 510 172 COOLING OPERATION COOLING PERFORMANCE DATA GSX130481A* 23 24 75 70 IDB* 54.2 0.67 20 3.95 14.7 231 101 50.1 0.65 20 3.85 14.3 224 98 56.8 0.80 22 4.01 15.0 235 103 55.1 0.76 23 3.98 14.8 233 102 50.9 0.73 23 3.88 14.4 226 99 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1700 1488 1913 1700 1488 63 52.4 0.66 21 3.96 14.8 243 105 56.8 0.68 21 4.06 15.2 251 108 58.5 0.71 20 4.09 15.3 253 110 51.9 0.54 17 3.93 14.6 241 104 56.2 0.56 17 4.03 15.0 248 107 57.9 0.59 16 4.06 15.2 251 108 67 56.7 0.50 17 4.09 15.3 257 115 61.5 0.52 17 4.19 15.7 265 118 63.3 0.54 16 4.22 15.9 268 120 56.8 0.37 13 4.05 15.1 254 114 61.6 0.39 13 4.15 15.6 262 117 63.4 0.41 12 4.19 15.7 265 118 * Entering Indoor Dry Bulb Temperature 1913 MBh S/T Delta T KW AMPS HI PR LO PR 59 55.9 0.70 19 3.98 14.8 233 102 MBh S/T Delta T KW AMPS HI PR LO PR Airflow 65 60.9 0.32 12 4.22 15.9 268 122 66.0 0.33 12 4.32 16.3 276 126 67.9 0.35 11 4.36 16.5 279 127 - - - 71 59 49.7 0.76 23 4.18 15.6 254 105 53.9 0.79 23 4.28 16.1 262 108 55.5 0.83 22 4.31 16.2 264 109 48.9 0.67 20 4.14 15.5 251 103 53.0 0.69 20 4.25 15.9 259 107 54.6 0.73 19 4.28 16.1 262 108 63 67 55.4 0.52 18 4.40 16.6 288 121 60.0 0.53 17 4.51 17.0 297 125 61.8 0.56 17 4.55 17.2 300 126 55.5 0.39 13 4.36 16.4 285 120 60.1 0.40 13 4.47 16.9 294 124 62.0 0.42 13 4.51 17.0 297 125 59.5 0.33 12 4.54 17.2 301 129 64.4 0.34 12 4.66 17.7 310 133 66.4 0.36 12 4.69 17.9 313 135 - - - 71 59 48.5 0.78 23 4.44 17.0 289 109 52.6 0.81 23 4.55 17.5 298 112 54.2 0.85 22 4.58 17.7 301 113 47.7 0.69 20 4.40 16.9 286 108 51.7 0.71 20 4.51 17.3 295 111 53.3 0.75 19 4.55 17.5 297 112 50.0 0.70 22 4.53 17.4 311 116 54.1 0.72 21 4.65 18.0 320 119 55.8 0.76 20 4.68 18.1 323 120 49.5 0.57 18 4.49 17.3 307 114 53.6 0.60 17 4.61 17.8 317 118 55.2 0.62 17 4.65 18.0 320 119 54.1 0.53 18 4.68 18.0 328 126 58.6 0.55 17 4.80 18.6 338 130 60.4 0.57 17 4.84 18.8 342 131 54.2 0.40 13 4.64 17.9 325 125 58.7 0.41 13 4.76 18.4 335 129 60.5 0.43 13 4.79 18.6 338 130 58.1 0.34 12 4.83 18.8 342 134 62.9 0.35 12 4.95 19.3 353 139 64.8 0.37 12 4.99 19.5 356 140 - - - 47.3 0.81 24 4.67 18.2 329 114 51.3 0.84 23 4.78 18.8 339 118 52.8 0.88 22 4.82 18.9 342 119 46.6 0.71 20 4.63 18.1 325 113 50.4 0.74 20 4.74 18.6 335 116 52.0 0.77 19 4.78 18.8 339 118 48.8 0.72 22 4.77 18.7 354 121 52.8 0.75 21 4.89 19.2 365 125 54.4 0.78 21 4.93 19.4 368 126 48.3 0.59 18 4.73 18.5 350 120 52.3 0.61 17 4.85 19.1 361 124 53.9 0.64 17 4.89 19.2 365 125 52.8 0.55 18 4.92 19.3 374 133 57.2 0.57 17 5.05 19.9 385 137 58.9 0.59 17 5.09 20.1 389 138 52.9 0.41 13 4.88 19.2 370 131 57.3 0.43 13 5.01 19.7 381 135 59.0 0.45 13 5.05 19.9 385 137 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 NOTE: Shaded area is ACCA (TVA) conditions 51.2 0.68 22 4.27 16.0 273 111 55.5 0.71 21 4.37 16.5 282 115 57.1 0.74 20 4.41 16.6 284 116 50.7 0.56 18 4.23 15.9 270 110 54.9 0.58 17 4.34 16.3 279 113 56.5 0.61 17 4.37 16.5 281 115 75 MODEL: GSX130601A* / CA*F4860*6**/ ZP51K5E-PFV 56.6 0.35 12 5.08 20.1 390 141 61.4 0.36 12 5.22 20.7 402 146 63.2 0.38 12 5.26 20.9 406 147 - - - 71 EXPANDED PERFORMANCE DATA 59 45.0 0.84 23 4.86 19.4 370 120 48.7 0.87 23 4.98 20.0 381 123 50.2 0.91 22 5.03 20.2 385 125 44.2 0.74 20 4.82 19.3 366 118 47.9 0.76 20 4.94 19.8 377 122 49.4 0.80 19 4.98 20.0 381 123 63 46.3 0.75 21 4.97 19.9 398 127 50.2 0.78 21 5.09 20.5 410 131 51.7 0.81 20 5.14 20.7 414 132 45.8 0.61 17 4.93 19.7 394 126 49.7 0.64 17 5.05 20.3 406 130 51.2 0.67 16 5.09 20.5 410 131 67 50.1 0.57 18 5.13 20.6 420 139 54.3 0.59 17 5.26 21.2 433 143 55.9 0.62 17 5.31 21.4 438 145 50.2 0.43 13 5.09 20.4 416 137 54.4 0.44 13 5.22 21.0 429 142 56.1 0.46 12 5.26 21.2 433 143 105 53.8 0.36 12 5.30 21.4 438 148 58.3 0.38 12 5.44 22.1 452 152 60.0 0.40 11 5.48 22.3 456 154 - - - 71 59 41.7 0.84 22 5.03 20.6 409 124 45.1 0.88 21 5.16 21.3 421 128 46.5 0.92 21 5.20 21.5 425 129 41.0 0.74 19 4.99 20.4 404 122 44.4 0.77 18 5.11 21.0 417 126 45.7 0.81 18 5.16 21.2 421 127 63 42.9 0.75 20 5.14 21.2 440 132 46.5 0.78 20 5.27 21.8 453 136 47.9 0.82 19 5.32 22.0 458 137 42.5 0.62 16 5.10 21.0 435 130 46.0 0.64 16 5.23 21.6 449 134 47.4 0.67 15 5.27 21.8 453 136 67 46.4 0.57 16 5.31 21.9 464 144 50.3 0.59 16 5.45 22.6 479 148 51.8 0.62 15 5.49 22.8 483 150 46.5 0.43 12 5.26 21.7 460 142 50.4 0.45 12 5.40 22.3 474 147 51.9 0.47 12 5.45 22.5 479 148 115 49.8 0.37 11 5.49 22.8 484 153 54.0 0.38 11 5.63 23.4 499 158 55.6 0.40 11 5.68 23.7 504 159 - - - 71 COOLING OPERATION COOLING PERFORMANCE DATA GSX130601A* 85 80 IDB* 56.1 0.84 25 4.01 15.0 236 103 51.8 0.81 26 3.91 14.5 228 100 58.8 0.92 26 4.07 15.2 240 105 57.1 0.88 27 4.04 15.1 238 104 52.7 0.85 28 3.94 14.7 231 101 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1700 1488 53.7 0.82 27 4.03 15.0 248 107 58.2 0.85 27 4.13 15.5 256 111 60.0 0.89 26 4.16 15.6 259 112 57.4 0.78 24 4.09 15.3 253 110 52.9 0.76 25 4.00 14.9 246 106 63 59.1 0.82 23 4.13 15.5 256 111 56.3 0.74 26 4.15 15.6 262 117 61.0 0.76 25 4.25 16.0 270 121 62.8 0.80 24 4.29 16.2 273 122 61.3 0.64 21 4.22 15.9 268 120 56.6 0.62 22 4.12 15.4 260 116 67 63.1 0.67 20 4.25 16.0 270 121 * Entering Indoor Dry Bulb Temperature 1913 1488 1700 1913 59 57.8 0.88 24 4.04 15.1 238 104 MBh S/T Delta T KW AMPS HI PR LO PR Airflow 65 60.0 0.60 22 4.28 16.2 273 125 65.0 0.62 22 4.39 16.6 282 129 67.0 0.65 21 4.43 16.8 285 130 65.5 0.48 17 4.36 16.5 279 127 60.5 0.46 17 4.25 16.0 271 124 71 67.5 0.50 16 4.39 16.6 282 129 51.5 0.88 28 4.24 15.9 259 107 55.8 0.91 27 4.35 16.4 267 110 57.5 0.95 26 4.38 16.5 270 111 54.8 0.87 26 4.31 16.2 264 109 50.6 0.84 26 4.21 15.8 256 106 59 56.5 0.91 25 4.35 16.4 267 110 55.0 0.76 26 4.47 16.9 294 124 59.6 0.79 25 4.58 17.4 303 128 61.3 0.83 24 4.62 17.5 306 129 59.9 0.66 21 4.55 17.2 300 126 55.2 0.64 22 4.44 16.7 291 123 67 61.6 0.69 21 4.58 17.4 303 128 58.6 0.62 22 4.62 17.5 307 132 63.5 0.64 22 4.73 18.0 316 136 65.4 0.67 21 4.77 18.2 320 137 64.0 0.49 17 4.70 17.9 313 135 59.1 0.48 17 4.58 17.4 304 131 71 65.9 0.52 16 4.73 18.0 316 136 50.3 0.90 28 4.51 17.3 294 111 54.5 0.93 27 4.62 17.9 304 114 56.1 0.98 26 4.66 18.0 307 115 53.5 0.89 26 4.58 17.7 301 113 49.4 0.86 26 4.47 17.2 292 110 59 55.1 0.93 25 4.62 17.9 304 114 51.2 0.87 27 4.61 17.8 317 118 55.5 0.90 27 4.72 18.3 327 122 57.2 0.94 26 4.76 18.5 330 123 54.7 0.83 25 4.68 18.1 323 120 50.5 0.80 25 4.57 17.6 314 117 53.7 0.78 26 4.75 18.4 335 129 58.1 0.81 25 4.88 18.9 345 133 59.9 0.85 24 4.92 19.1 348 134 58.4 0.68 21 4.84 18.8 342 131 53.9 0.65 22 4.72 18.2 331 127 57.2 0.63 22 4.91 19.1 349 137 62.0 0.66 22 5.04 19.7 360 141 63.9 0.69 21 5.08 19.9 363 143 62.5 0.51 17 5.00 19.5 356 140 57.6 0.49 17 4.87 18.9 346 136 NOTE: Shaded area is AHRI Rating Conditions 52.5 0.85 27 4.33 16.3 279 113 56.9 0.88 27 4.44 16.8 287 117 58.6 0.92 26 4.48 16.9 290 118 56.0 0.81 25 4.41 16.6 284 116 51.7 0.78 25 4.30 16.2 276 112 63 57.7 0.85 24 4.44 16.8 287 117 75 49.0 0.93 28 4.74 18.6 335 116 53.1 0.96 28 4.86 19.1 346 120 54.7 1.00 26 4.90 19.3 349 121 52.2 0.92 26 4.82 18.9 342 119 48.2 0.88 26 4.70 18.4 332 115 50.0 0.89 28 4.85 19.1 361 124 54.2 0.93 27 4.97 19.6 372 128 55.8 0.97 26 5.01 19.8 376 129 53.4 0.86 25 4.93 19.4 368 126 49.2 0.83 25 4.81 18.9 357 123 52.3 0.81 26 5.00 19.7 381 135 56.7 0.84 26 5.13 20.3 393 139 58.4 0.88 25 5.18 20.5 397 141 57.0 0.70 22 5.09 20.1 389 138 52.6 0.67 22 4.96 19.5 377 134 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 56.3 60.2 64.3 53.8 55.0 58.7 0.87 0.71 0.53 0.96 0.90 0.73 24 21 16 25 24 21 4.72 4.88 5.04 4.86 4.97 5.13 18.3 18.9 19.7 19.1 19.6 20.3 327 345 360 346 372 393 122 133 141 120 128 139 55.8 0.65 23 5.17 20.5 397 144 60.5 0.68 22 5.30 21.1 410 148 62.3 0.71 21 5.35 21.3 414 150 60.9 0.52 17 5.26 20.9 406 147 56.2 0.50 18 5.13 20.3 394 143 71 62.8 0.55 17 5.30 21.1 410 148 EXPANDED PERFORMANCE DATA MODEL: GSX130601AA / CA*F4860*6**/ ZP51K5E-PFV 46.6 0.96 28 4.94 19.8 377 122 50.5 1.00 27 5.07 20.4 389 126 52.0 1.00 25 5.11 20.6 393 127 49.6 0.95 26 5.03 20.2 385 125 45.8 0.92 26 4.90 19.6 374 121 59 51.1 1.00 25 5.07 20.4 389 126 47.5 0.93 27 5.05 20.3 406 130 51.4 0.96 27 5.18 20.9 419 134 53.0 1.00 25 5.22 21.1 423 135 50.7 0.89 24 5.14 20.7 414 132 46.8 0.86 25 5.01 20.1 402 129 63 52.2 0.94 23 5.18 20.9 419 134 49.7 0.84 26 5.22 21.0 429 142 53.9 0.87 25 5.35 21.6 442 146 55.5 0.91 24 5.40 21.9 446 148 54.2 0.73 21 5.31 21.4 438 145 50.0 0.70 22 5.17 20.8 424 140 67 55.8 0.76 20 5.35 21.6 442 146 105 53.1 0.68 22 5.39 21.9 447 151 57.5 0.70 22 5.53 22.5 461 156 59.2 0.74 21 5.58 22.7 466 157 57.9 0.54 17 5.48 22.3 456 154 53.4 0.52 17 5.35 21.6 443 149 71 59.6 0.57 16 5.53 22.5 461 156 43.1 0.97 26 5.11 21.0 417 126 46.7 1.00 25 5.24 21.7 430 130 48.2 1.00 23 5.29 21.9 434 131 45.9 0.96 24 5.20 21.5 426 129 42.4 0.93 24 5.07 20.8 413 125 59 47.3 1.00 23 5.24 21.7 430 130 44.0 0.94 25 5.23 21.6 449 134 47.7 0.97 25 5.36 22.2 462 138 49.1 1.00 24 5.41 22.4 467 140 46.9 0.90 23 5.32 22.0 458 137 43.3 0.87 23 5.18 21.4 444 133 63 48.4 0.94 22 5.36 22.2 462 138 46.1 0.84 24 5.40 22.3 474 147 49.9 0.88 24 5.54 23.0 488 151 51.4 0.92 23 5.59 23.2 493 153 50.2 0.73 20 5.49 22.8 484 150 46.3 0.71 20 5.35 22.1 469 145 67 51.7 0.77 19 5.54 23.0 488 151 115 49.1 0.69 21 5.58 23.2 494 156 53.2 0.71 20 5.73 23.9 509 161 54.8 0.75 20 5.78 24.1 514 163 53.6 0.55 16 5.68 23.7 504 159 49.5 0.53 16 5.53 23.0 489 155 71 55.2 0.57 15 5.73 23.9 509 161 COOLING OPERATION COOLING PERFORMANCE DATA GSX130601A* 25 26 75 70 IDB* 63 16.4 0.56 16 1.30 4.7 218 109 17.7 0.58 16 1.33 4.8 225 113 18.3 0.61 15 1.34 4.8 227 114 16.5 0.68 20 1.31 4.7 220 111 17.9 0.70 19 1.34 4.8 227 114 59 15.8 0.67 18 1.27 4.6 203 103 17.1 0.69 18 1.30 4.7 209 106 17.6 0.73 17 1.31 4.7 211 107 MBh 16.1 S/T 0.76 Delta T 21 KW 1.28 AMPS 4.6 HI PR 205 LO PR 104 MBh 17.4 S/T 0.79 Delta T 21 KW 1.31 AMPS 4.7 HI PR 211 LO PR 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 19.4 0.53 16 1.38 5.0 240 124 17.9 0.51 16 1.35 4.9 233 121 67 17.9 0.39 12 1.34 4.8 230 119 19.4 0.40 12 1.37 5.0 238 123 20.0 0.42 11 1.38 5.0 240 124 20.8 0.34 11 1.42 5.2 250 132 19.2 0.33 11 1.39 5.0 243 128 71 - 17.0 0.81 21 1.40 5.1 237 113 15.7 0.79 22 1.37 5.0 230 110 59 15.4 0.69 19 1.36 4.9 228 109 16.7 0.72 18 1.39 5.1 235 112 17.2 0.75 18 1.40 5.1 237 113 17.5 0.73 20 1.43 5.2 255 120 16.2 0.70 20 1.40 5.1 247 117 63 16.0 0.58 16 1.39 5.0 245 116 17.3 0.60 16 1.42 5.2 252 119 17.9 0.63 15 1.43 5.2 255 120 75 19.0 0.55 16 1.48 5.4 269 131 17.5 0.53 16 1.44 5.2 261 127 67 17.5 0.40 12 1.43 5.2 259 126 19.0 0.41 12 1.46 5.3 267 130 19.6 0.43 12 1.48 5.4 269 131 20.3 0.35 11 1.52 5.6 281 140 18.8 0.34 11 1.49 5.4 272 136 71 - 16.6 0.84 21 1.49 5.5 270 118 15.3 0.81 22 1.45 5.4 261 114 59 15.1 0.71 19 1.44 5.3 259 113 16.3 0.74 18 1.48 5.5 267 116 16.8 0.77 18 1.49 5.5 270 118 18.5 0.57 16 1.56 5.8 306 137 17.1 0.55 16 1.53 5.7 297 132 19.9 0.36 11 1.61 6.1 319 145 18.3 0.35 11 1.57 5.9 310 141 17.6 19.1 20.5 0.78 0.59 0.38 19 15 11 1.53 1.57 1.62 5.7 5.9 6.1 293 309 323 126 138 147 (TVA) conditions 17.1 0.75 20 1.52 5.7 290 125 15.8 0.72 20 1.48 5.5 281 121 16.7 0.90 21 1.57 6.0 310 125 16.2 0.86 21 1.56 5.9 307 124 15.0 0.83 22 1.52 5.7 298 120 18.1 0.58 16 1.64 6.2 349 143 16.7 0.77 20 1.59 6.0 330 131 17.2 0.81 19 1.60 6.1 334 133 18.6 0.61 16 1.65 6.3 352 145 16.7 0.56 16 1.60 6.1 338 139 15.4 0.74 20 1.55 5.9 320 127 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 15.6 17.1 14.7 15.2 16.7 0.59 0.41 0.73 0.61 0.42 16 12 19 16 12 1.47 1.51 1.51 1.54 1.59 5.5 5.6 5.7 5.8 6.0 279 294 295 317 335 120 131 119 126 138 16.9 18.5 15.9 16.5 18.1 0.61 0.43 0.76 0.63 0.44 16 12 19 16 12 1.51 1.55 1.55 1.58 1.63 5.6 5.8 5.9 6.0 6.2 287 303 304 327 345 124 135 122 130 142 17.4 19.1 16.4 17.0 18.6 0.64 0.45 0.80 0.66 0.46 15 12 18 15 12 1.52 1.56 1.56 1.59 1.64 5.7 5.8 5.9 6.0 6.2 290 306 307 330 349 125 137 123 131 143 20.0 0.39 11 1.70 6.5 368 154 19.4 0.38 11 1.69 6.5 364 153 17.9 0.36 11 1.65 6.3 353 148 71 - EXPANDED PERFORMANCE DATA MBh 17.9 18.5 20.0 21.5 17.5 18.0 19.5 21.0 17.1 S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 Delta T 20 19 15 10 20 19 15 11 20 675 KW 1.32 1.35 1.39 1.43 1.42 1.44 1.49 1.53 1.50 AMPS 4.8 4.9 5.0 5.2 5.1 5.3 5.4 5.6 5.6 HI PR 213 230 242 253 239 258 272 284 272 LO PR 108 115 126 134 114 122 133 141 119 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA High and low pressures are measured at the liquid and suction service valves. 600 525 675 600 525 Airflow 65 MODEL: GSX130181B* / CA*F1824*6B* 15.8 0.80 19 1.65 6.4 372 138 14.6 0.77 20 1.62 6.3 361 134 63 14.5 0.63 16 1.60 6.2 357 132 15.7 0.66 16 1.64 6.4 368 136 16.2 0.69 15 1.65 6.4 372 138 17.2 0.61 16 1.71 6.6 392 150 15.8 0.58 16 1.67 6.5 381 146 67 15.9 0.44 12 1.65 6.4 377 144 17.2 0.46 12 1.69 6.6 389 149 17.7 0.48 12 1.71 6.6 392 150 18.4 0.39 11 1.76 6.9 409 160 17.0 0.38 11 1.72 6.7 397 155 71 - 14.3 0.90 20 1.67 6.6 382 134 13.2 0.87 20 1.63 6.5 370 130 59 12.9 0.77 17 1.62 6.4 366 129 14.0 0.79 17 1.66 6.6 378 133 14.4 0.83 16 1.67 6.6 382 134 14.7 0.81 18 1.71 6.8 411 142 13.5 0.78 18 1.67 6.6 398 138 63 13.4 0.64 15 1.65 6.6 394 137 14.5 0.66 15 1.70 6.7 407 141 15.0 0.70 14 1.71 6.8 411 142 16.4 0.64 14 1.78 7.1 438 157 15.9 0.61 15 1.76 7.0 434 156 14.7 0.59 15 1.72 6.8 421 151 67 14.7 0.44 11 1.71 6.8 416 149 15.9 0.46 11 1.75 7.0 429 154 16.4 0.48 11 1.76 7.0 434 155 115 15.9 16.3 17.7 19.0 14.7 15.1 0.94 0.84 0.64 0.41 0.95 0.85 20 19 15 11 19 17 1.63 1.67 1.72 1.77 1.69 1.72 6.3 6.5 6.7 6.9 6.7 6.9 349 375 396 413 385 415 131 139 152 162 135 144 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 15.4 0.90 21 1.62 6.3 345 129 14.2 0.86 21 1.58 6.1 335 126 59 14.0 0.76 19 1.57 6.0 332 124 15.1 0.79 18 1.61 6.2 342 128 15.6 0.83 18 1.62 6.3 345 129 105 17.6 0.41 10 1.83 7.4 457 167 17.1 0.39 10 1.82 7.3 452 166 15.7 0.38 10 1.77 7.1 439 161 71 - COOLING OPERATION COOLING PERFORMANCE DATA GSX130181B*/VSX130181A* 85 80 IDB* 18.1 0.81 22 1.35 4.9 230 115 18.7 0.85 22 1.36 4.9 232 116 17.0 0.84 25 1.33 4.8 225 113 18.4 0.87 25 1.36 4.9 232 116 MBh 17.7 S/T 0.86 Delta T 23 KW 1.32 AMPS 4.8 HI PR 213 LO PR 108 MBh 18.3 S/T 0.90 Delta T 22 KW 1.33 AMPS 4.8 HI PR 215 LO PR 109 MBh 16.6 S/T 0.87 Delta T 25 KW 1.30 AMPS 4.7 HI PR 209 LO PR 106 MBh 18.0 S/T 0.90 Delta T 25 KW 1.33 AMPS 4.8 HI PR 215 LO PR 109 600 675 525 19.3 0.79 23 1.40 5.1 245 127 17.8 0.76 24 1.37 5.0 238 123 19.9 0.69 19 1.40 5.1 245 127 19.4 0.66 20 1.39 5.0 242 126 67 17.9 0.63 20 1.36 4.9 235 122 20.5 0.64 20 1.44 5.3 255 135 19.0 0.62 20 1.41 5.1 248 131 21.3 0.52 15 1.44 5.3 255 135 20.7 0.49 16 1.43 5.2 253 134 71 19.1 0.47 16 1.40 5.1 245 130 17.6 0.94 25 1.43 5.2 242 115 16.3 0.90 26 1.39 5.1 235 112 17.8 0.94 23 1.43 5.2 242 115 17.3 0.89 24 1.42 5.1 239 114 59 16.0 0.86 24 1.38 5.0 232 111 18.0 0.90 25 1.45 5.3 260 123 16.6 0.87 25 1.42 5.2 252 119 18.2 0.88 22 1.45 5.3 260 123 17.7 0.84 23 1.44 5.3 258 122 63 16.3 0.81 23 1.41 5.1 250 118 75 18.8 0.82 24 1.50 5.5 275 134 17.4 0.79 24 1.46 5.3 267 130 19.5 0.72 19 1.50 5.5 275 134 18.9 0.68 20 1.49 5.4 272 133 67 17.4 0.66 20 1.45 5.3 264 129 20.1 0.66 20 1.54 5.7 287 143 18.5 0.64 21 1.51 5.5 278 138 20.8 0.53 15 1.54 5.7 287 143 20.2 0.51 16 1.53 5.6 284 141 71 18.6 0.49 16 1.50 5.5 275 137 17.2 0.96 25 1.51 5.6 275 120 15.9 0.93 26 1.47 5.5 267 116 17.4 0.96 23 1.51 5.6 275 120 16.9 0.92 24 1.50 5.6 272 119 59 15.6 0.88 24 1.46 5.4 264 115 18.4 0.84 24 1.59 6.0 313 139 16.9 0.81 24 1.55 5.8 303 135 19.0 0.73 19 1.59 6.0 313 139 18.5 0.70 20 1.58 5.9 309 138 19.6 0.68 20 1.64 6.2 326 148 18.1 0.65 21 1.60 6.0 316 144 20.3 0.55 15 1.64 6.2 326 148 19.7 0.52 16 1.62 6.1 323 147 18.1 18.9 20.2 0.97 0.88 0.71 24 23 20 1.55 1.60 1.65 5.8 6.0 6.2 299 316 329 129 141 150 Rating Conditions 17.5 0.93 25 1.54 5.8 296 128 16.2 0.89 25 1.50 5.6 287 124 17.8 0.90 22 1.54 5.8 296 128 17.3 0.86 23 1.53 5.7 293 126 17.3 1.00 24 1.60 6.1 316 127 16.8 0.99 25 1.58 6.0 313 126 15.5 0.96 26 1.55 5.8 304 122 17.0 1.00 23 1.58 6.0 313 126 16.5 0.95 24 1.57 6.0 310 125 17.6 1.00 24 1.63 6.2 340 135 17.1 0.96 25 1.62 6.2 337 134 15.8 0.92 26 1.58 6.0 327 130 17.4 0.93 22 1.62 6.2 337 134 16.8 0.89 23 1.60 6.1 334 133 18.4 0.91 23 1.68 6.4 359 148 17.9 0.86 24 1.67 6.4 356 146 16.5 0.83 24 1.63 6.2 345 142 18.0 0.72 20 1.65 6.3 352 145 18.5 0.76 19 1.67 6.4 356 146 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 15.9 17.0 18.2 15.2 15.6 16.6 0.83 0.67 0.50 0.91 0.86 0.70 23 20 16 24 23 20 1.49 1.54 1.59 1.53 1.57 1.61 5.6 5.7 6.0 5.8 5.9 6.1 284 300 313 301 324 342 123 134 143 121 129 141 19.7 0.73 20 1.73 6.7 375 157 19.1 0.70 21 1.72 6.6 371 156 17.6 0.68 21 1.68 6.4 360 151 19.8 0.57 15 1.72 6.6 371 156 19.2 0.54 16 1.71 6.5 368 154 71 17.8 0.52 16 1.66 6.4 357 150 EXPANDED PERFORMANCE DATA MBh 18.6 18.9 19.8 21.2 18.1 18.5 19.4 20.7 17.7 S/T 0.95 0.91 0.83 0.67 0.98 0.95 0.86 0.69 1.00 Delta T 24 24 22 19 24 24 23 20 24 675 KW 1.34 1.37 1.41 1.45 1.44 1.47 1.51 1.56 1.52 AMPS 4.9 5.0 5.1 5.3 5.2 5.4 5.5 5.7 5.7 HI PR 218 234 247 258 244 263 278 289 278 LO PR 110 117 128 136 117 124 135 144 121 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI High and low pressures are measured at the liquid and suction service valves. 600 525 63 16.7 0.78 23 1.32 4.8 223 112 59 MBh 16.4 S/T 0.83 Delta T 24 KW 1.29 AMPS 4.6 HI PR 207 LO PR 105 Airflow 65 MODEL: GSX130181B* / CA*F1824*6B* 16.2 0.99 25 1.68 6.5 379 140 15.0 0.96 25 1.64 6.4 368 136 16.5 0.97 22 1.68 6.5 379 140 16.0 0.92 23 1.67 6.5 375 139 63 14.8 0.89 23 1.63 6.3 364 135 17.0 0.90 23 1.73 6.8 400 153 15.7 0.86 24 1.69 6.6 388 149 17.6 0.79 19 1.73 6.8 400 153 17.1 0.75 20 1.72 6.7 396 152 67 15.8 0.72 20 1.68 6.5 385 147 18.2 0.73 20 1.79 7.0 418 163 16.8 0.70 21 1.75 6.8 405 158 18.8 0.59 15 1.79 7.0 418 163 18.3 0.56 16 1.77 6.9 413 162 71 16.9 0.54 16 1.73 6.8 401 157 14.8 1.00 23 1.70 6.8 389 137 13.6 1.00 24 1.66 6.6 378 132 14.9 1.00 20 1.70 6.8 389 137 14.5 0.99 22 1.69 6.7 385 135 59 13.4 0.95 22 1.65 6.5 374 131 15.0 1.00 23 1.74 6.9 419 145 13.9 0.97 23 1.69 6.7 406 141 15.3 1.00 21 1.74 6.9 419 145 14.8 0.93 21 1.72 6.9 415 144 63 13.7 0.90 21 1.68 6.7 402 140 16.2 0.95 21 1.81 7.2 447 160 15.8 0.90 22 1.79 7.2 442 159 14.5 0.87 22 1.75 7.0 429 154 16.3 0.79 18 1.79 7.2 442 159 15.8 0.76 18 1.78 7.1 438 157 67 14.6 0.73 19 1.73 6.9 425 152 115 16.4 16.7 17.5 18.7 15.2 15.5 1.00 1.00 0.94 0.76 1.00 1.00 22 23 22 19 21 21 1.66 1.69 1.75 1.80 1.71 1.75 6.4 6.6 6.8 7.1 6.8 7.0 356 383 404 422 393 423 133 142 155 165 138 147 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 15.9 1.00 24 1.65 6.4 352 132 14.7 0.99 26 1.61 6.2 342 128 16.1 1.00 22 1.65 6.4 352 132 15.7 0.98 24 1.63 6.3 349 131 59 14.5 0.95 24 1.59 6.2 338 127 105 17.3 0.77 18 1.86 7.5 466 171 16.8 0.73 19 1.85 7.4 461 169 15.5 0.71 19 1.80 7.2 448 164 17.4 0.59 14 1.85 7.4 461 169 16.9 0.56 15 1.83 7.4 457 167 71 15.6 0.54 15 1.79 7.2 443 162 COOLING OPERATION COOLING PERFORMANCE DATA GSX130181B*/VSX130181A* 27 28 75 70 IDB* 59 17.8 0.75 18 1.26 10.8 209 106 17.3 0.71 19 1.25 10.8 207 105 16.0 0.69 19 1.22 10.7 201 102 18.1 0.85 21 1.26 10.8 211 108 17.6 0.81 22 1.26 10.8 209 106 MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR 18.1 0.72 20 1.28 10.9 225 113 18.7 0.76 19 1.29 10.9 227 114 63 18.5 0.62 16 1.28 10.9 225 113 17.9 0.59 16 1.27 10.9 223 112 16.6 0.57 17 1.24 10.7 216 109 19.6 0.55 16 1.32 11.0 238 124 20.2 0.57 16 1.33 11.1 240 125 67 20.3 0.43 12 1.32 11.0 238 124 19.7 0.41 12 1.31 11.0 235 122 18.1 0.40 13 1.28 10.9 228 119 21.1 0.35 11 1.35 11.2 248 132 21.7 0.37 11 1.36 11.2 250 133 71 - 17.2 0.84 22 1.34 11.1 235 112 17.7 0.88 21 1.35 11.2 237 114 59 17.4 0.77 18 1.34 11.1 235 112 16.9 0.74 19 1.33 11.1 232 111 15.6 0.71 19 1.30 11.0 225 108 17.7 0.75 20 1.37 11.2 253 120 18.2 0.79 20 1.38 11.3 255 121 63 18.1 0.65 16 1.37 11.2 253 120 17.5 0.62 17 1.36 11.2 250 118 16.2 0.59 17 1.33 11.1 243 115 75 19.2 0.57 17 1.41 11.4 267 131 19.7 0.60 16 1.42 11.4 269 132 67 19.8 0.45 12 1.41 11.4 267 131 19.2 0.43 13 1.40 11.3 264 129 17.7 0.41 13 1.37 11.2 256 125 20.6 0.37 12 1.45 11.6 278 139 21.2 0.38 11 1.46 11.6 281 141 71 - 16.8 0.86 22 1.42 11.5 267 117 17.3 0.90 21 1.43 11.6 270 118 59 17.0 0.79 18 1.42 11.5 267 117 16.5 0.76 19 1.41 11.5 264 116 15.2 0.73 19 1.38 11.3 256 112 18.7 0.58 17 1.49 11.8 303 136 19.3 0.61 16 1.50 11.8 306 137 20.1 0.37 12 1.54 12.0 316 145 20.7 0.39 11 1.55 12.0 320 146 16.0 17.3 18.5 0.74 0.56 0.36 21 17 12 1.42 1.46 1.50 11.5 11.7 11.8 279 294 307 121 132 140 (TVA) conditions 17.3 0.77 20 1.45 11.6 287 124 17.8 0.81 20 1.46 11.7 290 126 15.1 0.86 23 1.45 11.7 295 119 16.4 0.89 22 1.49 11.8 304 123 16.9 0.93 21 1.50 11.9 307 124 18.3 0.60 17 1.57 12.1 346 143 16.8 0.58 17 1.53 12.0 335 138 17.4 0.83 20 1.53 12.0 331 132 16.9 0.79 21 1.52 12.0 327 131 15.6 0.77 21 1.48 11.8 317 127 18.8 0.63 16 1.58 12.2 349 144 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 17.6 19.3 16.6 17.2 18.8 0.66 0.46 0.82 0.68 0.47 16 12 19 16 12 1.45 1.49 1.49 1.52 1.56 11.6 11.8 11.8 12.0 12.1 287 303 304 327 346 124 136 123 131 143 17.1 18.7 16.1 16.7 18.3 0.63 0.44 0.78 0.65 0.45 17 13 19 17 13 1.44 1.48 1.48 1.51 1.55 11.6 11.7 11.8 11.9 12.1 284 300 301 324 342 123 134 122 129 141 15.8 17.3 14.9 15.4 16.9 0.61 0.42 0.75 0.63 0.44 17 13 20 17 13 1.41 1.45 1.44 1.47 1.52 11.5 11.6 11.7 11.8 11.9 276 291 292 314 332 119 130 118 125 137 18.1 0.37 12 1.58 12.2 350 147 19.6 0.39 12 1.61 12.4 360 152 20.2 0.41 11 1.63 12.4 364 153 71 - EXPANDED PERFORMANCE DATA MBh 16.3 16.7 18.1 19.4 15.9 16.3 17.7 19.0 15.5 S/T 0.78 0.70 0.53 0.34 0.81 0.72 0.55 0.35 0.83 DT 22 20 17 12 22 21 17 12 23 525 KW 1.23 1.25 1.29 1.32 1.31 1.34 1.38 1.42 1.39 AMPS 10.7 10.8 10.9 11.1 11.0 11.1 11.3 11.4 11.4 HI PR 203 218 231 241 228 245 259 270 259 LO PR 103 110 120 128 109 116 127 135 113 * Entering Indoor Dry Bulb Tem perature NOTE: Shaded area is ACCA High and low pressures are measured at the liquid and suction service valves. 600 675 525 600 675 Airflow 65 MODEL: VSX130181B* / CA*F1824*6 16.0 0.82 20 1.58 12.3 368 137 16.5 0.86 19 1.59 12.4 372 138 63 16.3 0.71 16 1.58 12.3 368 137 15.9 0.68 16 1.57 12.3 364 136 14.6 0.65 17 1.53 12.1 354 131 17.3 0.62 17 1.63 12.5 389 149 17.9 0.65 16 1.64 12.6 393 151 67 17.9 0.49 12 1.63 12.5 389 149 17.4 0.47 12 1.61 12.4 385 148 16.0 0.45 13 1.58 12.3 373 144 18.6 0.40 11 1.68 12.7 406 159 19.2 0.42 11 1.69 12.8 410 161 71 - 14.4 0.93 21 1.60 12.5 378 133 14.8 0.97 20 1.61 12.6 382 134 59 14.6 0.86 17 1.60 12.5 378 133 14.2 0.82 18 1.58 12.5 374 132 13.1 0.79 18 1.55 12.3 363 128 14.8 0.83 19 1.63 12.6 407 142 15.3 0.87 18 1.64 12.7 411 143 63 15.1 0.72 15 1.63 12.6 407 142 14.7 0.68 15 1.62 12.6 403 140 13.6 0.66 16 1.58 12.4 391 136 14.8 0.61 16 1.64 12.7 417 150 16.1 0.63 15 1.68 12.9 430 155 16.5 0.66 15 1.69 12.9 434 156 67 16.6 0.50 11 1.68 12.8 430 155 16.1 0.47 12 1.67 12.8 425 153 14.9 0.46 12 1.63 12.6 412 148 115 14.4 14.8 16.0 17.2 13.3 13.7 0.89 0.79 0.60 0.39 0.90 0.80 22 21 17 12 21 19 1.51 1.54 1.59 1.64 1.56 1.59 12.0 12.2 12.3 12.6 12.3 12.5 332 357 377 393 367 395 125 133 145 154 129 137 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 15.6 0.92 22 1.55 12.2 342 129 16.0 0.97 21 1.56 12.2 346 130 59 15.8 0.85 18 1.55 12.2 342 129 15.3 0.81 19 1.53 12.1 339 127 14.1 0.78 19 1.50 12.0 329 124 105 15.9 0.39 11 1.69 12.9 435 160 17.2 0.40 11 1.73 13.1 448 165 17.8 0.42 10 1.75 13.1 453 166 71 - COOLING O PERATION COOLING PERFORMANCE DATA GSX130181C*/VSX130181B* 85 80 IDB* 18.8 0.98 25 1.28 10.9 216 110 18.2 0.93 26 1.27 10.9 213 109 16.8 0.90 26 1.25 10.8 207 105 MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR 59 18.5 0.93 23 1.27 10.9 213 109 17.9 0.89 24 1.26 10.8 211 108 16.5 0.86 25 1.24 10.7 205 104 MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR 63 19.1 0.94 25 1.31 11.0 232 117 18.6 0.90 26 1.30 11.0 230 116 17.2 0.87 26 1.27 10.9 223 112 18.9 0.87 22 1.30 11.0 230 116 18.3 0.83 23 1.29 10.9 227 114 16.9 0.80 24 1.26 10.8 221 111 67 20.1 0.85 23 1.35 11.2 245 127 19.5 0.81 24 1.34 11.1 243 126 18.0 0.78 25 1.31 11.0 235 122 20.2 0.71 20 1.34 11.1 243 126 19.6 0.68 20 1.33 11.1 240 125 18.1 0.65 21 1.30 11.0 233 121 71 21.4 0.69 20 1.39 11.3 256 136 20.8 0.66 21 1.38 11.3 253 134 19.2 0.63 21 1.34 11.2 245 130 21.5 0.53 16 1.38 11.3 253 134 20.9 0.51 16 1.37 11.2 251 133 19.3 0.49 17 1.33 11.1 243 129 59 18.3 1.00 25 1.37 11.3 242 116 17.8 0.96 26 1.36 11.2 240 115 16.4 0.93 27 1.33 11.1 232 111 18.0 0.96 24 1.36 11.2 240 115 17.5 0.92 25 1.35 11.2 237 114 16.2 0.89 25 1.32 11.0 230 110 63 18.7 0.98 25 1.40 11.4 260 123 18.2 0.93 26 1.39 11.3 258 122 16.8 0.90 26 1.36 11.2 250 118 18.4 0.90 23 1.39 11.3 258 122 17.9 0.86 24 1.38 11.3 255 121 16.5 0.83 24 1.35 11.2 248 117 75 67 19.6 0.88 23 1.44 11.5 275 135 19.0 0.84 24 1.43 11.5 272 133 17.6 0.81 25 1.40 11.3 264 129 19.7 0.74 20 1.43 11.5 272 133 19.1 0.70 21 1.42 11.4 270 132 17.6 0.68 21 1.39 11.3 261 128 71 20.9 0.71 20 1.49 11.7 287 143 20.3 0.68 21 1.47 11.7 284 142 18.7 0.66 22 1.44 11.5 275 138 21.0 0.55 16 1.47 11.7 284 142 20.4 0.52 16 1.46 11.6 281 141 18.9 0.51 17 1.43 11.5 273 136 59 17.9 1.00 24 1.45 11.6 275 120 17.4 0.99 26 1.44 11.6 272 119 16.0 0.95 27 1.41 11.5 264 116 17.6 1.00 24 1.44 11.6 272 119 17.1 0.94 25 1.43 11.6 270 118 15.8 0.91 25 1.40 11.4 262 115 18.3 1.00 25 1.48 11.8 296 128 17.7 0.95 26 1.47 11.7 293 127 16.4 0.92 26 1.44 11.6 284 123 18.0 0.93 23 1.47 11.7 293 127 17.5 0.88 24 1.46 11.7 290 126 16.1 0.85 24 1.43 11.5 282 122 19.1 0.90 24 1.53 11.9 313 140 18.6 0.86 24 1.52 11.9 310 139 17.1 0.83 25 1.48 11.7 300 134 19.2 0.76 20 1.52 11.9 310 139 18.7 0.72 21 1.50 11.8 307 137 17.2 0.69 21 1.47 11.7 297 133 20.4 0.73 20 1.57 12.1 326 149 19.8 0.70 21 1.56 12.1 323 148 18.3 0.67 22 1.53 11.9 313 143 20.5 0.56 16 1.56 12.1 323 148 19.9 0.54 16 1.55 12.0 320 146 18.4 0.52 17 1.51 11.9 310 142 17.5 1.00 24 1.52 12.0 313 127 17.0 1.00 26 1.51 11.9 310 125 15.7 0.98 27 1.48 11.8 301 122 17.2 1.00 23 1.51 11.9 310 125 16.7 0.97 25 1.50 11.9 307 124 15.4 0.94 25 1.47 11.8 298 120 17.8 1.00 24 1.55 12.1 337 135 17.3 0.99 26 1.54 12.1 334 133 16.0 0.95 27 1.51 11.9 324 129 17.5 0.96 23 1.54 12.1 334 133 17.0 0.91 24 1.53 12.0 331 132 15.7 0.88 24 1.50 11.9 321 128 18.7 0.93 24 1.60 12.3 356 147 18.1 0.89 25 1.59 12.3 353 145 16.7 0.86 25 1.55 12.1 342 141 18.2 0.74 21 1.58 12.2 349 144 16.8 0.72 21 1.54 12.0 339 140 18.7 0.78 20 1.59 12.3 353 145 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 19.9 0.76 21 1.65 12.5 371 156 19.3 0.72 21 1.64 12.5 368 155 17.8 0.70 22 1.60 12.3 357 150 20.0 0.58 16 1.64 12.5 368 155 19.5 0.56 17 1.63 12.4 364 153 18.0 0.54 17 1.59 12.2 353 149 71 EXPANDED PERFORMANCE DATA * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 525 600 675 525 600 675 Airflow 65 MODEL: VSX130181B* / CA*F1824*6 59 63 16.9 1.00 23 1.62 12.5 379 141 16.4 1.00 25 1.60 12.4 376 140 15.2 0.99 26 1.57 12.3 364 135 16.7 1.00 23 1.60 12.4 376 140 16.2 0.95 24 1.59 12.4 372 138 14.9 0.91 24 1.55 12.2 361 134 67 17.7 0.97 23 1.67 12.7 401 154 17.2 0.92 24 1.65 12.6 397 152 15.9 0.89 25 1.61 12.4 385 148 17.8 0.81 20 1.65 12.6 397 152 17.3 0.77 20 1.64 12.6 393 151 16.0 0.74 21 1.60 12.4 381 146 71 18.9 0.79 20 1.72 12.9 418 164 18.4 0.75 21 1.71 12.8 414 162 16.9 0.72 21 1.66 12.7 401 158 19.0 0.60 16 1.71 12.8 414 162 18.5 0.58 16 1.69 12.8 410 161 17.1 0.56 17 1.65 12.6 397 156 59 15.4 1.00 21 1.63 12.7 390 137 14.9 1.00 23 1.62 12.6 386 136 13.8 1.00 24 1.58 12.4 374 132 15.1 1.00 21 1.62 12.6 386 136 14.7 1.00 22 1.61 12.6 382 134 13.5 0.98 23 1.57 12.4 370 130 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 16.6 1.00 23 1.58 12.3 353 133 16.1 1.00 25 1.57 12.3 349 131 14.9 1.00 26 1.53 12.1 339 127 16.3 1.00 22 1.57 12.3 349 131 15.8 1.00 24 1.56 12.2 346 130 14.6 0.97 25 1.52 12.1 335 126 105 63 15.7 1.00 21 1.67 12.8 419 146 15.2 1.00 23 1.66 12.8 415 144 14.0 0.99 24 1.62 12.6 403 140 15.4 1.00 21 1.66 12.8 415 144 15.0 0.96 22 1.64 12.7 411 143 13.8 0.92 22 1.60 12.5 399 139 67 16.4 0.98 22 1.72 13.0 443 159 15.9 0.93 23 1.71 13.0 438 158 14.7 0.90 23 1.67 12.8 425 153 16.5 0.82 18 1.71 13.0 438 158 16.0 0.78 19 1.69 12.9 434 156 14.8 0.75 19 1.65 12.7 421 151 115 17.5 0.79 19 1.78 13.3 462 170 17.0 0.75 20 1.76 13.2 457 168 15.7 0.73 20 1.72 13.0 443 163 17.6 0.61 15 1.76 13.2 457 168 17.1 0.58 15 1.75 13.1 453 166 15.8 0.56 16 1.71 13.0 439 161 71 COOLING OPERATION COOLING PERFORMANCE DATA GSX130181C*/VSX130181B* 29 30 75 70 IDB* 23.7 0.58 16 1.73 6.0 232 110 24.4 0.61 15 1.74 6.0 234 111 22.1 0.69 20 1.71 5.9 227 108 23.9 0.71 20 1.74 6.0 234 111 24.6 0.75 19 1.75 6.1 236 112 MBh 22.8 S/T 0.70 Delta T 18 KW 1.71 AMPS 5.8 HI PR 215 LO PR 103 MBh 23.5 S/T 0.73 Delta T 18 KW 1.71 AMPS 5.9 HI PR 217 LO PR 104 MBh 21.4 S/T 0.77 Delta T 22 KW 1.69 AMPS 5.7 HI PR 211 LO PR 101 MBh 23.2 S/T 0.79 Delta T 21 KW 1.71 AMPS 5.9 HI PR 218 LO PR 104 MBh 23.9 S/T 0.83 Delta T 20 KW 1.72 AMPS 5.9 HI PR 220 LO PR 105 800 900 700 800 900 26.7 0.56 15 1.79 6.3 250 122 25.9 0.54 16 1.78 6.2 247 121 23.9 0.52 16 1.75 6.1 240 118 26.7 0.42 12 1.78 6.2 247 121 25.9 0.40 12 1.77 6.2 245 120 67 23.9 0.39 12 1.74 6.0 237 116 28.6 0.36 11 1.83 6.5 260 130 27.8 0.35 11 1.82 6.5 258 129 25.6 0.33 11 1.79 6.3 250 125 - - 71 - 23.4 0.86 21 1.82 6.4 247 111 22.7 0.82 21 1.81 6.4 244 110 20.9 0.79 22 1.78 6.2 237 107 23.0 0.76 18 1.81 6.4 244 110 22.3 0.72 19 1.80 6.3 242 109 59 20.6 0.70 19 1.77 6.1 234 106 24.1 0.77 19 1.85 6.6 265 119 23.4 0.74 20 1.84 6.5 263 117 21.6 0.71 20 1.80 6.3 255 114 23.8 0.63 15 1.84 6.5 263 117 23.1 0.61 16 1.82 6.5 260 116 63 21.3 0.58 16 1.79 6.3 252 113 75 26.0 0.58 16 1.89 6.8 280 129 25.3 0.56 16 1.88 6.7 277 128 23.3 0.54 16 1.84 6.6 269 124 26.1 0.44 12 1.88 6.7 277 128 25.3 0.42 12 1.87 6.7 275 127 67 23.4 0.40 12 1.83 6.5 266 123 27.9 0.38 11 1.93 7.1 292 138 27.1 0.36 11 1.92 7.0 289 136 25.0 0.35 11 1.89 6.8 281 132 - - 71 - 22.8 0.89 21 1.90 7.0 280 116 22.1 0.84 21 1.89 6.9 278 115 20.4 0.81 22 1.86 6.7 269 111 22.4 0.78 18 1.89 6.9 278 115 21.8 0.74 19 1.88 6.9 275 114 59 20.1 0.72 19 1.84 6.7 267 110 23.5 0.79 19 1.93 7.2 302 123 22.8 0.76 20 1.92 7.1 299 122 21.0 0.73 20 1.88 6.9 290 118 23.2 0.65 15 1.92 7.1 299 122 22.6 0.62 16 1.91 7.0 296 121 25.4 0.60 16 1.98 7.4 319 135 24.7 0.57 16 1.97 7.3 315 133 22.8 0.55 16 1.93 7.1 306 129 25.5 0.45 12 1.97 7.3 315 133 24.7 0.43 12 1.95 7.3 312 132 27.3 0.39 11 2.03 7.7 332 143 26.5 0.37 11 2.01 7.6 329 142 24.4 0.35 11 1.98 7.4 319 138 - - 22.2 0.91 21 1.97 7.5 319 122 21.6 0.87 22 1.96 7.4 316 120 19.9 0.84 22 1.93 7.2 307 117 21.9 0.80 18 1.96 7.4 316 120 21.2 0.77 19 1.95 7.3 313 119 22.2 0.57 17 2.00 7.6 348 136 24.1 0.59 16 2.04 7.8 359 140 24.8 0.62 16 2.06 7.9 363 141 22.2 0.78 20 1.99 7.6 340 128 22.9 0.82 19 2.01 7.6 344 129 24.8 0.47 12 2.04 7.8 359 140 24.1 0.44 12 2.03 7.8 356 138 20.5 0.75 20 1.96 7.4 330 124 22.7 0.67 16 1.99 7.6 340 128 22.0 0.64 16 1.98 7.5 337 127 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 20.8 22.8 19.6 20.3 22.3 0.60 0.41 0.74 0.62 0.43 16 12 19 16 13 1.87 1.92 1.91 1.94 1.99 6.8 7.1 7.1 7.3 7.5 287 303 304 327 345 117 128 116 123 134 26.6 0.40 11 2.11 8.2 378 150 25.8 0.38 11 2.09 8.1 375 149 23.8 0.37 11 2.05 7.9 363 145 - - 71 - EXPANDED PERFORMANCE DATA * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 700 63 21.8 0.56 16 1.70 5.8 225 107 59 MBh 21.1 S/T 0.67 Delta T 19 KW 1.68 AMPS 5.7 HI PR 209 LO PR 100 Airflow 65 MODEL: GSX130241B* / CA*F1824*6B* 21.8 0.85 19 2.07 8.1 387 136 21.1 0.81 20 2.06 8.1 383 134 19.5 0.78 20 2.02 7.8 371 130 21.5 0.70 15 2.06 8.1 383 134 20.9 0.66 16 2.04 8.0 379 133 63 19.3 0.64 16 2.01 7.8 368 129 23.6 0.64 15 2.12 8.4 408 148 22.9 0.61 16 2.11 8.3 404 147 21.1 0.59 16 2.07 8.1 392 142 23.6 0.48 12 2.11 8.3 404 147 22.9 0.46 12 2.09 8.3 400 145 67 21.1 0.44 12 2.05 8.0 388 141 25.3 0.41 11 2.18 8.7 426 158 24.5 0.39 11 2.16 8.6 422 156 22.7 0.38 11 2.12 8.4 409 151 - - 71 - 19.6 0.96 19 2.09 8.4 397 132 19.0 0.91 20 2.08 8.3 393 131 17.5 0.88 20 2.04 8.1 381 127 19.3 0.84 17 2.08 8.3 393 131 18.7 0.80 17 2.06 8.3 389 129 59 17.3 0.77 18 2.02 8.0 377 125 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 21.1 0.95 20 2.04 7.9 359 127 20.5 0.90 21 2.02 7.9 356 126 18.9 0.87 22 1.99 7.7 345 122 20.8 0.83 18 2.02 7.9 356 126 20.2 0.80 18 2.01 7.8 352 125 59 18.6 0.77 19 1.97 7.6 342 121 105 20.2 0.86 18 2.13 8.6 427 140 19.6 0.82 18 2.11 8.5 423 139 18.1 0.79 19 2.07 8.3 410 135 20.0 0.70 14 2.11 8.5 423 139 19.4 0.67 15 2.10 8.5 419 137 63 17.9 0.65 15 2.06 8.2 406 133 21.8 0.65 14 2.18 8.9 451 153 21.2 0.62 15 2.17 8.8 447 152 19.6 0.60 15 2.12 8.6 433 147 21.9 0.49 11 2.16 8.8 446 152 21.2 0.46 11 2.15 8.7 442 150 67 19.6 0.45 12 2.11 8.5 429 146 115 23.4 0.42 10 2.24 9.3 470 163 22.7 0.40 10 2.22 9.2 466 161 21.0 0.38 11 2.18 8.9 452 157 - - 71 - COOLING OPERATION COOLING PERFORMANCE DATA GSX130241B*/VSX130241A* 85 80 IDB* 63 22.3 0.79 23 1.72 5.9 229 109 24.1 0.82 23 1.75 6.1 236 112 24.9 0.86 22 1.76 6.1 239 113 22.6 0.85 25 1.73 6.0 232 110 24.5 0.88 25 1.76 6.1 239 113 59 21.8 0.84 24 1.70 5.8 213 102 23.6 0.87 24 1.72 5.9 220 105 24.3 0.91 23 1.73 6.0 222 107 MBh 22.2 S/T 0.88 Delta T 26 KW 1.70 AMPS 5.8 HI PR 215 LO PR 103 MBh 24.0 S/T 0.91 Delta T 25 KW 1.73 AMPS 6.0 HI PR 222 LO PR 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 25.7 0.80 23 1.80 6.3 252 124 23.7 0.77 24 1.77 6.2 245 120 67 23.8 0.64 20 1.76 6.1 242 119 25.8 0.67 20 1.79 6.3 250 123 26.6 0.70 19 1.80 6.3 252 124 27.4 0.65 20 1.84 6.6 263 132 25.3 0.62 21 1.81 6.4 255 128 71 25.5 0.48 16 1.80 6.3 253 127 27.6 0.50 16 1.83 6.5 260 130 28.4 0.52 15 1.84 6.6 263 132 23.5 0.95 26 1.83 6.5 249 113 21.7 0.91 26 1.80 6.3 242 109 59 21.3 0.87 24 1.79 6.3 239 108 23.1 0.90 24 1.82 6.4 247 111 23.8 0.95 23 1.83 6.5 249 113 23.9 0.91 25 1.86 6.6 268 120 22.1 0.88 26 1.82 6.5 260 116 63 21.8 0.82 23 1.81 6.4 257 115 23.6 0.85 23 1.85 6.6 265 119 24.3 0.89 22 1.86 6.6 268 120 75 25.1 0.82 24 1.90 6.9 283 131 23.1 0.80 24 1.87 6.7 274 127 67 23.3 0.67 20 1.86 6.6 272 126 25.2 0.69 20 1.89 6.8 280 129 26.0 0.72 19 1.90 6.9 283 131 26.8 0.67 21 1.95 7.1 295 139 24.7 0.65 21 1.91 6.9 286 135 71 24.9 0.50 16 1.90 6.9 283 134 26.9 0.52 16 1.93 7.1 292 138 27.7 0.54 15 1.95 7.1 295 139 22.9 0.97 26 1.91 7.0 283 117 21.2 0.94 26 1.88 6.9 275 113 59 20.8 0.89 24 1.87 6.8 272 112 22.5 0.93 24 1.90 7.0 280 116 23.2 1.00 24 1.91 7.0 283 117 24.5 0.85 24 1.99 7.5 322 136 22.6 0.82 24 1.95 7.3 312 132 26.1 0.69 21 2.04 7.7 336 145 24.1 0.66 21 2.00 7.5 326 140 24.1 25.2 26.9 0.98 0.89 0.72 24 23 20 1.96 2.00 2.05 7.3 7.5 7.8 308 325 339 126 137 146 Rating Conditions 23.4 0.94 25 1.94 7.2 305 124 21.6 0.90 26 1.91 7.0 296 121 23.0 1.00 24 2.00 7.6 326 124 22.4 1.00 26 1.99 7.5 323 123 20.6 0.97 26 1.95 7.3 313 119 23.5 1.00 24 2.03 7.8 351 132 22.8 0.97 25 2.02 7.7 347 131 21.0 0.93 26 1.98 7.5 337 127 24.6 0.92 23 2.08 8.0 370 144 23.9 0.87 24 2.07 8.0 367 143 22.0 0.84 24 2.03 7.8 356 138 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 21.3 22.7 24.3 20.3 20.7 22.2 0.84 0.68 0.51 0.92 0.86 0.70 23 20 16 25 24 20 1.90 1.94 1.99 1.94 1.97 2.02 7.0 7.2 7.5 7.3 7.4 7.7 293 309 322 310 333 352 120 130 139 118 126 137 23.0 24.6 26.3 22.0 22.5 24.0 0.87 0.71 0.53 0.96 0.90 0.73 20 23 20 16 24 23 2.06 1.93 1.98 2.03 1.97 2.01 7.2 7.4 7.7 7.5 7.6 7.9 302 319 332 319 344 363 123 135 143 122 129 141 23.7 25.3 27.1 22.6 23.1 24.7 0.91 0.74 0.55 1.00 0.94 0.77 22 19 15 23 22 19 1.94 1.99 2.04 1.99 2.02 2.07 7.2 7.5 7.7 7.5 7.7 8.0 305 322 336 323 347 367 124 136 145 123 131 143 26.2 0.74 20 2.14 8.4 386 154 25.5 0.71 21 2.12 8.3 382 152 23.5 0.68 21 2.08 8.0 371 147 71 23.7 0.53 16 2.07 8.0 367 146 25.7 0.55 16 2.11 8.2 379 150 26.4 0.57 15 2.12 8.3 382 152 EXPANDED PERFORMANCE DATA MBh 24.8 25.2 26.4 28.2 24.2 24.7 25.8 27.6 23.6 S/T 0.96 0.92 0.83 0.68 0.99 0.96 0.86 0.70 1.00 Delta T 24 24 23 20 25 24 23 20 24 900 KW 1.74 1.77 1.81 1.85 1.84 1.87 1.91 1.96 1.92 AMPS 6.1 6.2 6.4 6.6 6.5 6.7 6.9 7.2 7.1 HI PR 224 241 255 266 251 271 286 298 286 LO PR 108 114 125 133 114 121 132 141 118 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI High and low pressures are measured at the liquid and suction service valves. 800 700 900 800 700 Airflow 65 MODEL: GSX130241B* / CA*F1824*6B* 21.7 1.00 25 2.08 8.2 390 137 20.0 0.97 25 2.04 8.0 379 133 63 19.7 0.90 23 2.03 7.9 375 132 21.3 0.93 23 2.07 8.1 387 136 22.0 1.00 22 2.08 8.2 390 137 22.7 0.91 24 2.14 8.5 412 150 20.9 0.87 24 2.09 8.3 400 145 67 21.0 0.73 20 2.08 8.2 396 144 22.8 0.76 20 2.12 8.4 408 148 23.5 0.79 19 2.14 8.5 412 150 24.2 0.74 20 2.19 8.8 430 159 22.3 0.71 21 2.15 8.6 417 155 71 22.5 0.55 16 2.13 8.5 413 153 24.4 0.57 16 2.18 8.7 426 158 25.1 0.59 15 2.19 8.8 430 159 19.7 1.00 23 2.10 8.5 401 133 18.2 1.00 24 2.06 8.3 389 129 59 17.9 0.97 23 2.05 8.2 385 128 19.3 1.00 22 2.09 8.4 397 132 19.9 1.00 20 2.10 8.5 401 133 20.1 1.00 23 2.14 8.7 431 142 18.5 0.98 24 2.10 8.5 419 137 63 18.2 0.91 22 2.08 8.4 414 136 19.8 0.94 21 2.13 8.6 427 140 20.4 1.00 21 2.14 8.7 431 142 21.6 0.96 21 2.21 9.1 460 156 21.0 0.91 22 2.19 9.0 456 155 19.4 0.88 22 2.15 8.7 442 150 67 19.5 0.74 19 2.14 8.7 438 149 21.1 0.76 19 2.18 8.9 451 153 21.8 0.80 18 2.19 9.0 456 155 115 21.9 22.3 23.4 24.9 20.3 20.7 1.00 1.00 0.95 0.77 1.00 1.00 22 23 23 20 21 21 2.06 2.10 2.15 2.21 2.12 2.15 8.1 8.3 8.6 8.9 8.6 8.8 366 394 416 434 405 436 143 130 138 151 161 135 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 21.2 1.00 24 2.05 8.0 363 129 19.6 1.00 26 2.01 7.8 352 125 59 19.3 0.96 24 2.00 7.7 348 124 20.9 0.99 24 2.04 7.9 359 127 21.5 1.00 22 2.05 8.0 363 129 105 23.1 0.78 18 2.27 9.4 480 166 22.4 0.74 19 2.25 9.3 475 165 20.7 0.71 19 2.21 9.1 461 160 71 20.8 0.55 15 2.19 9.0 456 158 22.6 0.57 15 2.24 9.3 470 163 23.3 0.60 14 2.25 9.3 475 165 COOLING OPERATION COOLING PERFORMANCE DATA GSX130241B*/VSX130241A* 31 32 75 70 IDB* 28.8 0.63 15 2.04 7.2 256 113 26.1 0.70 19 1.99 7.1 248 110 28.3 0.73 19 2.04 7.2 256 113 MBh 27.8 S/T 0.75 Delta T 17 KW 2.00 AMPS 7.1 HI PR 237 LO PR 106 MBh 25.4 S/T 0.79 Delta T 21 KW 1.95 AMPS 6.9 HI PR 230 LO PR 103 MBh 27.5 S/T 0.82 Delta T 21 KW 2.00 AMPS 7.1 HI PR 238 LO PR 106 1125 875 30.6 0.55 16 2.10 7.5 270 124 28.3 0.53 16 2.05 7.3 262 120 31.6 0.44 11 2.10 7.5 270 124 67 28.3 0.40 12 2.03 7.2 259 119 30.7 0.42 12 2.08 7.4 267 122 32.9 0.36 11 2.16 7.8 282 132 30.3 0.34 11 2.11 7.6 273 128 - 71 - 26.8 0.85 21 2.14 7.7 267 112 24.8 0.82 21 2.09 7.4 259 109 27.2 0.78 17 2.14 7.7 266 112 59 24.4 0.72 18 2.08 7.4 256 108 26.4 0.74 18 2.13 7.6 264 111 27.6 0.76 19 2.19 7.8 287 120 25.5 0.73 20 2.14 7.6 278 116 28.2 0.65 15 2.19 7.8 287 120 63 25.2 0.60 16 2.12 7.6 275 115 27.4 0.62 16 2.17 7.8 284 118 75 29.9 0.57 16 2.25 8.1 303 131 27.6 0.55 16 2.20 7.9 294 127 30.9 0.45 11 2.25 8.1 303 131 67 27.7 0.42 12 2.18 7.8 291 125 30.0 0.43 12 2.24 8.0 300 129 32.1 0.37 11 2.32 8.4 316 139 29.6 0.36 11 2.27 8.2 306 135 - 71 - 26.2 0.87 21 2.27 8.3 303 117 24.2 0.84 21 2.22 8.1 294 113 26.5 0.80 17 2.27 8.3 303 117 59 23.8 0.74 18 2.20 8.0 291 112 25.8 0.76 18 2.25 8.2 300 116 29.2 0.59 16 2.39 8.8 344 136 26.9 0.57 16 2.33 8.6 334 132 30.1 0.46 11 2.39 8.8 344 136 31.3 0.38 11 2.47 9.1 359 145 28.9 0.36 11 2.41 8.9 349 140 - 27.8 30.1 32.3 0.81 0.62 0.40 18 15 10 2.34 2.41 2.49 8.6 8.9 9.2 329 348 363 126 137 146 (TVA) conditions 27.0 0.78 19 2.32 8.5 326 124 24.9 0.75 20 2.26 8.3 316 121 27.5 0.67 15 2.32 8.5 326 124 26.3 0.94 20 2.40 9.0 349 124 25.6 0.90 21 2.39 8.9 345 123 23.6 0.86 21 2.33 8.6 335 119 25.9 0.83 17 2.39 8.9 345 123 28.5 0.61 16 2.51 9.4 392 143 29.3 0.64 15 2.53 9.5 396 144 27.1 0.84 19 2.46 9.2 375 132 26.3 0.58 16 2.45 9.2 381 138 29.4 0.48 11 2.51 9.4 392 143 24.3 0.77 20 2.38 8.9 360 127 26.3 0.80 19 2.44 9.1 372 131 26.8 0.69 15 2.44 9.1 371 131 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 24.6 27.0 23.2 24.0 26.3 0.61 0.43 0.76 0.63 0.44 16 12 19 16 12 2.25 2.32 2.31 2.36 2.43 8.2 8.5 8.6 8.8 9.1 313 331 332 357 377 119 130 118 125 137 26.7 29.3 25.1 26.1 28.5 0.64 0.44 0.79 0.66 0.46 16 12 18 16 12 2.30 2.37 2.37 2.42 2.49 8.4 8.7 8.8 9.0 9.3 323 341 342 368 388 123 134 122 129 141 31.5 0.41 11 2.61 9.9 413 153 30.6 0.39 11 2.59 9.8 409 152 28.2 0.38 11 2.53 9.5 397 147 - 71 - EXPANDED PERFORMANCE DATA MBh 28.3 29.1 31.5 33.9 27.6 28.5 30.8 33.1 27.0 S/T 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91 Delta T 20 18 15 10 20 18 15 10 20 1125 KW 2.01 2.05 2.11 2.18 2.16 2.20 2.27 2.34 2.29 AMPS 7.1 7.3 7.6 7.8 7.7 7.9 8.2 8.5 8.4 HI PR 240 258 273 284 269 290 306 319 306 LO PR 107 114 125 133 114 121 132 140 118 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA High and low pressures are measured at the liquid and suction service valves. 1000 1000 875 63 25.8 0.58 16 1.98 7.0 245 109 28.0 0.60 15 2.02 7.2 253 112 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 59 24.9 0.69 18 1.94 6.8 228 102 27.0 0.72 18 1.98 7.0 235 105 Airflow 65 MODEL: GSX130301B* / CA*F3030*6B* 25.0 0.83 19 2.53 9.7 418 137 23.1 0.80 19 2.47 9.4 405 133 25.5 0.72 15 2.53 9.7 418 137 63 22.8 0.66 16 2.45 9.3 401 131 24.7 0.68 16 2.51 9.6 414 135 27.1 0.63 16 2.62 10.0 441 149 25.0 0.61 16 2.55 9.7 428 145 27.9 0.50 11 2.62 10.0 441 149 67 25.0 0.46 12 2.53 9.7 424 143 27.1 0.47 12 2.59 9.9 437 148 29.0 0.40 11 2.70 10.4 460 159 26.8 0.39 11 2.63 10.1 447 154 - 71 - 22.5 0.94 19 2.57 10.0 429 133 20.8 0.90 20 2.50 9.7 416 129 22.8 0.86 16 2.56 10.0 429 133 59 20.4 0.80 17 2.48 9.7 412 128 22.1 0.82 17 2.54 9.9 425 132 23.2 0.84 18 2.62 10.3 462 142 21.4 0.81 18 2.56 10.0 448 137 23.6 0.72 14 2.62 10.3 462 142 63 21.2 0.66 15 2.54 9.9 443 136 22.9 0.69 15 2.60 10.2 457 140 25.8 0.67 14 2.73 10.7 493 156 25.1 0.63 15 2.70 10.6 488 155 23.1 0.61 15 2.64 10.3 473 150 25.9 0.50 11 2.70 10.6 488 155 67 23.2 0.46 11 2.62 10.2 468 148 25.1 0.48 11 2.68 10.5 483 153 115 25.0 25.8 27.9 29.9 23.2 23.9 0.97 0.87 0.66 0.42 0.98 0.88 20 18 15 10 19 17 2.50 2.56 2.64 2.72 2.59 2.64 9.6 9.8 10.1 10.5 10.1 10.4 392 422 446 465 433 466 130 138 151 161 134 143 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 24.3 0.93 21 2.48 9.5 388 129 22.4 0.90 21 2.42 9.2 377 125 24.6 0.86 17 2.48 9.5 388 129 59 22.0 0.79 18 2.40 9.1 373 124 23.9 0.82 18 2.46 9.4 384 127 105 27.7 0.43 10 2.82 11.1 514 166 26.9 0.41 10 2.79 11.0 509 165 24.8 0.39 10 2.72 10.7 493 160 - 71 - CO OLING OPERATION COOLING PERFORMANCE DATA GSX130301B*/VSX130301A* 85 80 IDB* 28.6 0.84 22 2.05 7.3 258 114 29.4 0.88 21 2.07 7.4 261 116 28.0 0.90 23 2.01 7.1 240 107 28.8 0.94 22 2.03 7.2 242 109 26.3 0.91 25 1.98 7.0 235 105 28.5 0.94 25 2.03 7.2 242 109 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 26.8 0.87 25 2.02 7.2 253 112 29.0 0.91 24 2.07 7.4 261 116 63 26.4 0.81 22 2.01 7.1 250 111 59 MBh 25.8 S/T 0.86 Delta T 23 KW 1.97 AMPS 7.0 HI PR 233 LO PR 104 28.0 0.79 23 2.08 7.4 267 122 30.4 0.82 23 2.13 7.6 275 126 30.5 0.68 19 2.12 7.6 273 125 31.4 0.72 18 2.13 7.6 275 126 67 28.2 0.66 20 2.07 7.3 264 121 29.9 0.64 20 2.15 7.7 279 130 32.4 0.66 20 2.20 7.9 287 134 32.6 0.51 15 2.18 7.8 284 133 33.6 0.54 15 2.20 7.9 287 134 71 30.1 0.49 16 2.13 7.6 276 129 25.7 0.94 25 2.13 7.6 264 111 27.8 0.97 25 2.18 7.8 272 115 27.3 0.93 23 2.16 7.7 269 114 28.1 1.00 23 2.18 7.8 272 115 59 25.2 0.90 24 2.11 7.5 261 110 26.1 0.91 25 2.17 7.8 284 118 28.3 0.94 24 2.22 8.0 293 122 27.9 0.87 22 2.20 7.9 290 121 28.7 0.91 21 2.22 8.0 293 122 63 25.8 0.84 23 2.15 7.7 281 117 75 27.4 0.82 24 2.24 8.0 300 129 29.7 0.85 23 2.29 8.2 309 133 29.8 0.71 19 2.27 8.2 306 132 30.7 0.74 19 2.29 8.2 309 133 67 27.5 0.68 20 2.22 7.9 297 128 29.2 0.66 20 2.31 8.3 313 138 31.7 0.69 20 2.36 8.6 322 142 31.9 0.53 16 2.34 8.5 319 140 32.8 0.56 15 2.36 8.6 322 142 71 29.4 0.51 16 2.29 8.2 310 136 25.0 0.96 25 2.25 8.2 300 116 27.1 1.00 25 2.31 8.5 309 119 26.7 0.95 23 2.29 8.4 306 118 27.5 1.00 22 2.31 8.5 309 119 59 24.6 0.92 24 2.24 8.2 297 114 26.7 0.84 24 2.37 8.7 341 134 29.0 0.87 23 2.43 9.0 351 138 29.1 0.73 19 2.41 8.9 348 137 30.0 0.76 19 2.43 9.0 351 138 28.5 0.68 20 2.45 9.0 356 143 30.9 0.71 20 2.51 9.3 367 147 31.1 0.54 16 2.49 9.2 363 146 32.1 0.57 15 2.51 9.3 367 147 28.5 29.8 31.8 1.00 0.91 0.74 23 22 19 2.37 2.45 2.53 8.8 9.0 9.4 336 355 370 128 140 149 Rating Conditions 25.5 0.93 25 2.30 8.4 323 123 27.7 0.96 24 2.36 8.7 333 127 27.2 0.89 22 2.34 8.6 330 126 28.1 0.94 21 2.36 8.7 333 127 27.3 1.00 22 2.44 9.1 356 126 24.4 0.99 25 2.37 8.8 342 121 26.5 1.00 24 2.42 9.1 352 125 26.0 0.98 23 2.40 9.0 349 124 26.8 1.00 22 2.42 9.1 352 125 27.8 1.00 23 2.49 9.4 383 135 24.9 0.96 25 2.42 9.0 368 129 27.0 0.99 25 2.48 9.3 379 133 26.6 0.92 23 2.46 9.2 375 132 27.4 0.97 22 2.48 9.3 379 133 29.1 0.94 22 2.57 9.7 404 147 26.1 0.86 24 2.49 9.3 388 141 28.3 0.90 23 2.55 9.6 400 145 28.4 0.75 20 2.53 9.5 396 144 29.3 0.79 19 2.55 9.6 400 145 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 25.1 26.9 28.7 24.0 24.5 26.2 0.86 0.70 0.52 0.95 0.89 0.72 23 20 16 24 23 20 2.28 2.35 2.43 2.35 2.40 2.47 8.4 8.6 9.0 8.7 8.9 9.2 320 338 352 338 364 384 122 133 142 120 128 140 31.1 0.76 19 2.66 10.0 422 156 27.8 0.70 21 2.57 9.7 405 150 30.1 0.73 20 2.64 10.0 417 155 30.4 0.56 16 2.61 9.9 413 153 31.3 0.59 15 2.64 10.0 417 155 71 28.0 0.54 16 2.55 9.6 401 149 EXPANDED PERFORMANCE DATA MBh 29.3 29.9 31.3 33.4 28.6 29.2 30.6 32.6 27.9 S/T 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 Delta T 24 23 22 19 23 23 22 19 23 1125 KW 2.04 2.08 2.15 2.21 2.19 2.24 2.31 2.38 2.33 AMPS 7.3 7.4 7.7 8.0 7.9 8.1 8.3 8.6 8.5 HI PR 245 263 278 290 275 296 312 326 312 LO PR 110 117 127 136 116 123 135 143 120 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI High and low pressures are measured at the liquid and suction service valves. 1000 875 1125 1000 875 Airflow 65 MODEL: GSX130301B* / CA*F3030*6B* 23.7 0.99 25 2.51 9.6 414 135 25.6 1.00 24 2.58 9.9 426 140 25.3 0.96 22 2.56 9.8 422 138 26.0 1.00 21 2.58 9.9 426 140 63 23.3 0.92 23 2.49 9.5 410 134 24.8 0.90 23 2.59 9.9 437 148 26.8 0.93 23 2.66 10.2 450 152 27.0 0.78 19 2.64 10.1 446 151 27.8 0.82 19 2.66 10.2 450 152 67 24.9 0.75 20 2.57 9.8 432 146 26.4 0.73 20 2.68 10.3 456 157 28.6 0.76 20 2.74 10.6 470 162 28.8 0.58 15 2.72 10.5 465 161 29.7 0.61 15 2.74 10.6 470 162 71 26.6 0.56 16 2.66 10.2 451 156 21.5 1.00 23 2.54 9.9 425 132 23.3 1.00 21 2.61 10.2 438 136 22.9 1.00 21 2.59 10.1 433 134 23.6 1.00 19 2.61 10.2 438 136 59 21.1 0.99 22 2.52 9.8 420 130 21.9 1.00 23 2.60 10.2 457 140 23.7 1.00 22 2.66 10.5 471 144 23.4 0.96 21 2.64 10.4 466 143 24.1 1.00 20 2.66 10.5 471 144 63 21.6 0.93 21 2.58 10.1 452 139 25.6 0.98 21 2.77 10.9 503 159 23.0 0.91 22 2.68 10.5 483 153 24.9 0.94 21 2.75 10.8 498 158 25.0 0.78 18 2.73 10.7 493 156 25.7 0.82 17 2.75 10.8 498 158 67 23.1 0.76 18 2.66 10.4 478 151 115 25.9 26.4 27.7 29.5 24.0 24.5 1.00 1.00 0.98 0.79 1.00 1.00 21 22 22 19 20 20 2.54 2.60 2.68 2.77 2.63 2.69 9.7 10.0 10.3 10.7 10.3 10.6 400 431 455 474 442 476 133 141 154 164 137 146 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 23.2 1.00 24 2.46 9.4 384 127 25.1 1.00 23 2.52 9.6 396 131 24.7 1.00 23 2.50 9.6 392 130 25.5 1.00 21 2.52 9.6 396 131 59 22.8 0.98 24 2.44 9.3 381 126 105 27.3 0.80 18 2.86 11.3 524 170 24.5 0.73 19 2.77 10.9 503 163 26.5 0.76 19 2.84 11.2 519 168 26.7 0.59 14 2.82 11.1 514 166 27.5 0.62 14 2.84 11.2 519 168 71 24.7 0.57 15 2.75 10.8 498 161 COOLING OPERATION COOLING PERFORMANCE DATA GSX130301B*/VSX130301A* 33 34 75 70 IDB* 34.2 0.82 22 2.47 9.1 223 103 MBh S/T Delta T KW AMPS HI PR LO PR 1200 35.3 0.73 20 2.52 9.3 240 110 32.5 0.71 20 2.46 9.0 233 107 38.2 0.56 16 2.60 9.6 254 120 35.2 0.54 17 2.54 9.3 246 117 38.2 0.42 12 2.58 9.5 251 119 39.4 0.44 12 2.60 9.6 254 120 41.0 0.36 11 2.68 10.0 265 128 37.8 0.34 11 2.62 9.7 257 124 - 71 - 33.5 0.85 22 2.65 9.8 251 109 30.9 0.82 22 2.59 9.5 243 106 32.9 0.75 19 2.63 9.7 248 108 33.9 0.78 18 2.65 9.8 250 109 59 30.4 0.72 19 2.57 9.4 241 105 34.4 0.76 20 2.71 10.0 270 116 31.8 0.73 20 2.65 9.8 262 113 34.1 0.62 16 2.69 10.0 267 115 35.1 0.65 16 2.71 10.0 270 116 63 31.5 0.60 17 2.63 9.7 259 112 37.3 0.58 16 2.79 10.4 285 127 34.4 0.55 17 2.73 10.1 276 123 37.4 0.43 12 2.77 10.3 282 126 38.5 0.45 12 2.79 10.4 285 127 67 34.5 0.42 13 2.71 10.0 273 122 40.0 0.37 11 2.88 10.8 297 135 36.9 0.36 12 2.81 10.5 288 131 - 71 - 32.7 0.87 22 2.82 10.7 285 114 30.1 0.84 22 2.75 10.4 276 110 32.1 0.77 19 2.79 10.6 282 112 33.1 0.80 18 2.82 10.7 285 114 59 29.6 0.74 19 2.73 10.3 274 109 33.6 0.78 20 2.88 10.9 307 121 31.0 0.75 20 2.81 10.6 297 117 33.3 0.64 16 2.85 10.8 304 120 34.3 0.67 16 2.88 10.9 307 121 36.4 0.59 16 2.97 11.3 324 132 33.6 0.57 17 2.89 11.0 314 128 36.5 0.44 12 2.94 11.2 321 131 37.6 0.47 12 2.97 11.3 324 132 36.1 0.37 12 2.99 11.4 328 136 29.4 0.87 22 2.89 11.1 315 116 31.3 0.79 19 2.93 11.3 321 118 32.3 0.83 18 2.96 11.4 324 119 32.8 0.94 21 2.98 11.5 328 121 31.6 0.79 22 2.41 8.8 217 100 MBh S/T Delta T KW AMPS HI PR LO PR 34.9 0.60 16 2.50 9.2 238 109 36.0 0.63 15 2.52 9.3 240 110 67 35.3 0.40 12 2.52 9.2 244 115 MBh 35.3 36.3 39.3 42.2 34.5 35.5 38.4 41.2 33.6 34.6 37.5 40.2 S/T 0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.91 0.82 0.62 0.40 Delta T 21 19 16 11 21 19 16 11 21 19 16 11 1350 KW 2.49 2.54 2.62 2.70 2.68 2.73 2.82 2.91 2.84 2.90 2.99 3.09 AMPS 9.1 9.4 9.7 10.0 9.9 10.1 10.5 10.9 10.8 11.0 11.4 11.8 HI PR 226 243 256 267 253 272 288 300 288 310 327 341 LO PR 104 111 121 129 110 117 128 137 115 122 133 142 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 33.7 0.72 19 2.45 9.0 221 102 34.7 0.76 18 2.47 9.1 223 103 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 63 32.2 0.58 16 2.44 8.9 231 106 30.3 0.78 21 2.95 11.4 339 123 32.8 0.80 20 3.02 11.7 349 127 33.8 0.84 19 3.05 11.8 353 128 32.5 0.66 16 3.00 11.6 346 126 33.4 0.69 16 3.02 11.7 349 127 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 30.7 33.7 28.9 30.0 0.62 0.43 0.76 0.64 17 13 19 17 2.78 2.87 2.86 2.92 10.5 10.9 11.0 11.3 294 311 312 335 116 127 115 122 31.9 0.90 22 2.96 11.4 325 119 59 31.1 0.70 19 2.40 8.7 214 99 MBh S/T Delta T KW AMPS HI PR LO PR 75 36.6 0.64 16 3.14 12.2 372 140 35.5 0.61 17 3.12 12.1 369 139 32.8 0.59 17 3.04 11.7 358 134 35.6 0.46 12 3.09 12.0 365 137 36.6 0.48 12 3.12 12.1 369 139 67 32.8 0.44 13 3.02 11.6 354 133 39.3 0.41 11 3.25 12.7 388 149 38.1 0.39 11 3.22 12.5 385 148 35.2 0.38 12 3.14 12.2 373 143 - 71 - EXPANDED PERFORMANCE DATA 39.1 0.38 11 3.06 11.7 338 141 1050 1350 1200 1050 Airflow 65 MODEL: GSX130361B* / CA*F3036*6C* 31.2 0.83 20 3.15 12.5 393 133 28.8 0.81 20 3.07 12.1 381 129 30.8 0.69 16 3.12 12.3 389 132 31.8 0.72 16 3.15 12.5 393 133 63 28.5 0.66 16 3.04 12.0 377 128 33.7 0.63 16 3.25 12.9 415 145 31.1 0.61 17 3.17 12.5 402 141 33.8 0.48 12 3.22 12.8 411 144 34.8 0.50 12 3.25 12.9 415 145 67 31.2 0.46 13 3.14 12.4 398 139 36.2 0.41 11 3.35 13.4 433 155 33.4 0.39 11 3.27 13.0 420 150 - 71 - 28.0 0.94 20 3.18 12.9 403 129 25.9 0.91 21 3.11 12.5 391 125 27.6 0.83 17 3.16 12.8 399 128 28.4 0.87 17 3.18 12.9 403 129 59 25.4 0.80 18 3.08 12.4 387 124 28.9 0.84 19 3.25 13.2 434 138 26.6 0.81 19 3.17 12.8 421 133 28.6 0.69 15 3.23 13.1 430 136 29.4 0.73 15 3.25 13.2 434 138 63 26.4 0.67 15 3.15 12.7 417 132 32.2 0.67 15 3.39 13.8 463 152 31.2 0.64 15 3.36 13.7 458 150 28.8 0.61 16 3.28 13.3 445 146 31.3 0.48 11 3.33 13.5 454 149 32.2 0.50 11 3.36 13.7 458 150 67 28.9 0.46 12 3.25 13.1 440 144 115 31.2 32.1 34.7 37.3 28.9 29.7 0.98 0.88 0.66 0.43 0.99 0.88 21 19 16 11 19 18 3.10 3.17 3.27 3.38 3.21 3.28 12.3 12.6 13.0 13.5 13.0 13.3 369 397 419 437 407 438 126 134 147 156 131 139 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 30.3 0.93 22 3.08 12.2 365 125 27.9 0.90 22 3.00 11.8 354 121 29.8 0.82 19 3.05 12.0 361 124 30.7 0.86 18 3.08 12.1 365 125 59 27.5 0.79 19 2.98 11.7 351 120 105 34.5 0.43 10 3.50 14.3 483 162 33.5 0.41 11 3.47 14.2 478 160 31.0 0.40 11 3.38 13.8 464 155 - 71 - COOLING OPERATION COOLING PERFORMANCE DATA GSX130361B*/VSX130361A* 85 80 IDB* 34.9 0.90 24 2.49 9.1 226 105 35.9 0.94 23 2.51 9.2 228 106 32.7 0.91 26 2.45 9.0 221 102 35.5 0.94 26 2.51 9.2 228 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1200 1350 1050 34.6 0.98 26 2.70 10.0 256 112 32.0 0.94 26 2.63 9.7 248 108 35.1 1.00 24 2.70 10.0 256 112 34.0 0.93 24 2.68 9.9 253 110 59 31.4 0.90 25 2.61 9.6 245 107 35.3 0.94 26 2.75 10.2 275 119 32.6 0.91 26 2.69 10.0 267 115 35.8 0.92 22 2.75 10.2 275 119 34.8 0.87 23 2.73 10.1 272 117 63 32.1 0.84 24 2.67 9.9 264 114 37.0 0.85 24 2.84 10.6 290 130 34.1 0.82 25 2.77 10.3 282 126 38.3 0.75 19 2.84 10.6 290 130 37.2 0.71 20 2.82 10.5 288 128 67 34.3 0.69 21 2.75 10.2 279 124 39.5 0.69 21 2.93 11.0 303 138 36.4 0.67 21 2.86 10.7 294 134 40.9 0.56 16 2.93 11.0 303 138 39.7 0.53 16 2.91 10.9 300 137 71 36.7 0.51 16 2.84 10.6 291 132 33.8 1.00 26 2.86 10.9 291 116 31.2 0.97 26 2.79 10.6 282 112 34.2 1.00 23 2.86 10.9 291 116 33.2 0.96 24 2.84 10.8 288 115 59 30.7 0.92 25 2.77 10.5 279 111 34.5 0.97 26 2.92 11.1 313 123 31.8 0.93 26 2.85 10.8 303 120 35.0 0.94 22 2.92 11.1 313 123 34.0 0.90 23 2.90 11.0 310 122 36.1 0.87 24 3.01 11.5 330 135 33.3 0.84 25 2.94 11.2 320 131 37.4 0.76 19 3.01 11.5 330 135 36.3 0.73 20 2.99 11.4 327 133 35.6 0.68 21 3.04 11.6 334 139 40.0 0.57 16 3.11 11.9 345 143 38.8 0.55 16 3.09 11.8 341 142 30.5 1.00 27 2.93 11.3 321 118 33.4 1.00 23 3.01 11.6 331 122 32.4 0.99 25 2.98 11.5 328 121 34.0 1.00 23 3.03 11.7 334 123 40.4 0.67 21 2.72 10.1 270 131 37.3 0.64 21 2.66 9.9 262 127 41.9 0.54 15 2.72 10.1 270 131 40.7 0.51 16 2.70 10.0 267 129 71 37.5 0.49 16 2.64 9.8 259 125 MBh 36.5 37.2 39.0 41.6 35.7 36.4 38.1 40.6 34.8 35.5 37.2 39.7 S/T 0.99 0.95 0.86 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.91 0.74 Delta T 25 24 23 20 24 24 23 20 24 24 23 20 1350 KW 2.53 2.58 2.66 2.74 2.72 2.77 2.86 2.95 2.88 2.95 3.04 3.14 AMPS 9.3 9.5 9.9 10.2 10.1 10.3 10.7 11.1 11.0 11.2 11.6 12.1 HI PR 230 248 261 273 258 278 293 306 294 316 334 348 107 113 124 132 113 120 131 139 117 125 136 145 LO PR * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 1200 37.9 0.82 24 2.64 9.8 259 123 34.9 0.79 24 2.58 9.5 251 119 39.2 0.72 19 2.64 9.8 259 123 38.1 0.69 20 2.62 9.7 256 121 67 35.1 0.66 20 2.56 9.4 249 118 34.6 1.00 24 3.10 12.0 360 131 33.6 1.00 26 3.07 11.9 356 130 31.0 0.96 26 3.00 11.6 346 126 34.1 0.97 23 3.07 11.9 356 130 33.1 0.93 23 3.05 11.8 353 128 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 31.3 33.5 35.8 29.9 30.6 0.86 0.70 0.53 0.95 0.89 24 21 16 25 24 2.83 2.92 3.01 2.91 2.97 10.7 11.1 11.5 11.2 11.5 300 317 331 318 342 118 129 138 117 124 33.0 1.00 25 3.01 11.6 331 122 36.2 0.91 25 2.56 9.5 245 112 33.4 0.88 26 2.50 9.2 238 109 36.7 0.88 22 2.56 9.5 245 112 35.6 0.84 23 2.54 9.4 243 111 63 32.9 0.81 23 2.48 9.1 235 108 75 36.3 0.94 23 3.20 12.4 380 143 35.2 0.90 24 3.17 12.3 376 141 32.5 0.87 25 3.09 12.0 365 137 35.4 0.75 20 3.14 12.2 373 140 36.5 0.79 20 3.17 12.3 376 141 67 32.7 0.73 21 3.07 11.9 361 136 38.7 0.77 20 3.30 12.9 396 152 37.6 0.73 21 3.27 12.8 392 151 34.7 0.70 21 3.19 12.4 381 146 39.0 0.59 16 3.27 12.8 392 151 37.8 0.56 16 3.25 12.7 389 149 71 34.9 0.54 17 3.17 12.3 377 145 EXPANDED PERFORMANCE DATA 38.5 0.71 21 3.11 11.9 345 143 1050 59 32.2 0.87 24 2.43 8.9 219 101 MBh S/T Delta T KW AMPS HI PR LO PR Airflow 65 MODEL: GSX130361B* / CA*F3036*6C* 31.9 1.00 24 3.20 12.7 401 136 29.5 1.00 26 3.12 12.3 389 132 32.4 1.00 22 3.20 12.7 401 136 31.5 0.96 23 3.17 12.6 397 134 63 29.1 0.93 24 3.09 12.2 385 130 33.5 0.93 24 3.30 13.1 423 148 30.9 0.90 24 3.22 12.8 411 144 34.6 0.82 19 3.30 13.1 423 148 33.6 0.78 20 3.27 13.0 419 147 67 31.0 0.75 20 3.19 12.6 406 142 35.7 0.76 21 3.41 13.6 441 158 33.0 0.73 21 3.33 13.2 428 153 37.0 0.61 15 3.41 13.6 441 158 36.0 0.58 16 3.38 13.5 437 156 71 33.2 0.56 16 3.30 13.1 424 152 29.0 1.00 22 3.24 13.1 412 132 26.8 1.00 23 3.16 12.8 399 128 29.4 1.00 20 3.24 13.1 412 132 28.5 1.00 22 3.21 13.0 407 131 59 26.3 1.00 23 3.13 12.6 395 127 29.6 1.00 23 3.31 13.5 443 140 27.3 1.00 24 3.23 13.1 430 136 30.0 1.00 20 3.31 13.5 443 140 29.2 0.97 22 3.28 13.3 438 139 63 26.9 0.93 22 3.20 13.0 425 135 31.9 0.99 21 3.44 14.0 472 155 31.0 0.94 22 3.42 13.9 468 153 28.6 0.91 23 3.33 13.5 454 149 32.1 0.83 18 3.42 13.9 468 153 31.2 0.79 19 3.39 13.8 463 152 67 28.8 0.76 19 3.30 13.4 449 147 115 32.3 32.9 34.5 36.8 29.9 30.5 1.00 1.00 0.98 0.80 1.00 1.00 22 22 23 20 20 21 3.16 3.22 3.33 3.44 3.26 3.33 12.5 12.8 13.2 13.8 13.3 13.6 376 405 427 446 416 447 129 137 150 159 133 142 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 31.3 1.00 24 3.13 12.4 372 128 28.9 1.00 25 3.05 12.0 361 124 31.7 1.00 22 3.13 12.4 372 128 30.8 1.00 24 3.11 12.3 369 126 59 28.4 0.99 25 3.03 11.9 358 123 105 34.1 0.80 19 3.56 14.6 493 165 33.1 0.76 19 3.53 14.5 488 163 30.5 0.74 20 3.44 14.0 473 158 34.3 0.62 14 3.53 14.5 488 163 33.3 0.59 15 3.50 14.3 483 162 71 30.7 0.57 15 3.41 13.9 468 157 COOLING OPERATION COOLING PERFORMANCE DATA GSX130361B*/VSX130361A* 35 36 75 70 IDB* 39.0 0.71 18 2.84 10.9 216 104 40.2 0.75 18 2.87 11.0 218 105 36.6 0.78 21 2.80 10.8 212 102 39.7 0.81 21 2.87 11.0 218 105 40.9 0.85 20 2.89 11.1 220 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1400 1575 1225 1400 1575 42.1 0.76 19 2.94 11.4 237 113 40.8 0.72 19 2.92 11.3 235 112 37.7 0.70 20 2.86 11.0 228 108 41.6 0.62 15 2.92 11.3 235 112 40.4 0.59 16 2.90 11.2 232 111 63 37.3 0.57 16 2.84 10.9 225 107 45.5 0.57 15 3.03 11.8 250 123 44.2 0.55 16 3.01 11.7 248 122 40.8 0.53 16 2.94 11.3 240 118 45.6 0.43 11 3.01 11.7 248 122 44.3 0.41 12 2.98 11.6 245 121 67 40.9 0.40 12 2.92 11.2 238 117 48.9 0.37 11 3.12 12.2 261 131 47.4 0.35 11 3.10 12.1 259 130 43.8 0.34 11 3.03 11.8 251 126 - - 71 - 39.9 0.88 20 3.09 12.0 247 112 38.7 0.84 21 3.07 11.9 245 111 35.8 0.81 22 3.00 11.6 237 108 39.2 0.77 18 3.07 11.9 245 111 38.1 0.74 18 3.05 11.8 242 110 59 35.2 0.71 19 2.98 11.5 235 106 41.1 0.79 19 3.15 12.3 266 119 39.9 0.75 20 3.13 12.2 263 118 36.8 0.72 20 3.06 11.9 256 114 40.7 0.65 15 3.13 12.2 263 118 39.5 0.62 16 3.11 12.1 261 117 63 36.4 0.59 16 3.04 11.8 253 113 75 44.5 0.60 15 3.25 12.7 281 130 43.2 0.57 16 3.22 12.6 278 129 39.9 0.55 16 3.15 12.2 270 125 44.6 0.45 12 3.22 12.6 278 129 43.3 0.43 12 3.20 12.5 275 127 67 39.9 0.41 12 3.13 12.1 267 124 47.7 0.38 11 3.35 13.2 293 139 46.3 0.37 11 3.32 13.0 290 137 42.8 0.35 11 3.24 12.7 281 133 - - 71 - 39.0 0.90 21 3.27 13.0 281 116 37.8 0.86 21 3.25 12.9 278 115 34.9 0.83 22 3.17 12.6 270 112 38.3 0.79 18 3.25 12.9 278 115 37.2 0.76 18 3.22 12.8 276 114 59 34.3 0.73 19 3.15 12.5 267 111 40.1 0.81 19 3.34 13.3 303 124 38.9 0.77 20 3.31 13.2 300 123 35.9 0.74 20 3.24 12.9 291 119 39.7 0.66 15 3.31 13.2 300 123 38.5 0.63 16 3.29 13.1 297 121 43.4 0.61 15 3.44 13.8 320 135 42.2 0.58 16 3.41 13.6 316 134 38.9 0.56 16 3.33 13.3 307 130 43.5 0.46 12 3.41 13.6 316 134 42.2 0.44 12 3.39 13.5 313 132 46.6 0.39 11 3.55 14.3 333 144 45.2 0.37 11 3.52 14.1 330 143 41.8 0.36 11 3.44 13.8 320 138 - - 38.0 0.93 21 3.43 13.9 320 122 36.9 0.89 22 3.41 13.8 317 121 34.1 0.86 22 3.33 13.4 308 117 37.4 0.82 18 3.41 13.8 317 121 36.3 0.78 19 3.38 13.7 314 120 41.1 0.60 16 3.58 14.6 360 141 42.4 0.63 16 3.61 14.7 364 142 39.1 0.83 19 3.50 14.2 345 130 38.0 0.58 17 3.50 14.2 350 136 42.4 0.47 12 3.58 14.6 360 141 41.2 0.45 12 3.55 14.4 357 139 35.1 0.77 20 3.39 13.7 331 125 38.0 0.79 20 3.48 14.1 341 129 38.7 0.68 15 3.48 14.1 341 129 37.6 0.65 16 3.45 14.0 338 127 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 35.6 39.0 33.5 34.7 38.0 0.61 0.42 0.75 0.63 0.44 16 12 19 16 12 3.21 3.31 3.30 3.37 3.47 12.7 13.2 13.3 13.6 14.0 288 304 304 328 346 118 129 116 124 135 45.5 0.41 11 3.72 15.2 380 151 44.1 0.39 11 3.70 15.1 376 150 40.7 0.37 11 3.61 14.7 365 145 - - 71 - EXPANDED PERFORMANCE DATA * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 1225 59 36.0 0.69 19 2.78 10.7 209 101 MBh S/T Delta T KW AMPS HI PR LO PR Airflow 65 MODEL: GSX130421B* / CA*F3642*6C* 37.2 0.86 19 3.64 15.1 388 136 36.1 0.82 20 3.61 15.0 384 135 33.3 0.79 20 3.53 14.6 372 131 36.8 0.71 15 3.61 15.0 384 135 35.7 0.68 16 3.58 14.9 380 134 63 33.0 0.65 16 3.50 14.5 369 130 40.2 0.65 15 3.76 15.6 409 149 39.1 0.62 16 3.73 15.5 405 147 36.1 0.60 16 3.64 15.1 393 143 40.3 0.49 12 3.73 15.5 405 147 39.1 0.47 12 3.70 15.3 401 146 67 36.1 0.45 12 3.61 14.9 389 141 43.2 0.42 11 3.87 16.2 427 158 41.9 0.40 11 3.84 16.1 423 157 38.7 0.39 11 3.75 15.6 410 152 - - 71 - 33.4 0.97 19 3.68 15.6 398 133 32.5 0.93 20 3.66 15.5 394 131 30.0 0.90 20 3.57 15.1 382 127 32.9 0.86 16 3.66 15.5 394 131 31.9 0.82 17 3.63 15.4 390 130 59 29.5 0.79 17 3.54 14.9 378 126 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 36.1 0.97 20 3.57 14.8 360 128 35.1 0.92 21 3.54 14.6 357 127 32.4 0.89 22 3.46 14.2 346 123 35.5 0.85 18 3.54 14.6 357 127 34.5 0.81 18 3.51 14.5 353 126 59 31.8 0.78 19 3.43 14.1 343 122 105 34.4 0.87 18 3.76 16.0 428 141 33.4 0.83 18 3.73 15.9 424 140 30.9 0.80 19 3.64 15.4 411 135 34.1 0.72 14 3.73 15.9 424 140 33.1 0.68 15 3.70 15.7 420 138 63 30.5 0.66 15 3.61 15.3 407 134 37.3 0.66 14 3.88 16.5 452 154 36.2 0.63 15 3.85 16.4 448 152 33.4 0.61 15 3.76 15.9 434 148 37.3 0.50 11 3.85 16.4 448 152 36.3 0.47 11 3.82 16.2 443 151 67 33.5 0.46 11 3.73 15.8 430 146 115 40.0 0.42 10 4.00 17.2 472 164 38.8 0.40 10 3.97 17.0 467 162 35.8 0.39 10 3.88 16.5 453 157 - - 71 - COOLING OPERATION COOLING PERFORMANCE DATA GSX130421B*/VSX130421A* 85 80 IDB* 41.6 0.93 23 2.91 11.2 223 107 37.9 0.90 26 2.84 10.9 216 104 41.1 0.93 25 2.91 11.2 223 107 42.3 0.98 24 2.93 11.3 225 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1575 1225 1400 1575 43.1 0.94 24 2.99 11.6 242 115 41.9 0.90 25 2.96 11.5 240 114 38.6 0.87 25 2.90 11.2 232 110 42.5 0.87 22 2.96 11.5 240 114 63 38.1 0.80 23 2.88 11.1 230 109 41.3 0.83 23 2.94 11.4 237 113 * Entering Indoor Dry Bulb Temperature 1400 1225 59 37.3 0.86 24 2.82 10.8 214 103 40.4 0.89 24 2.89 11.1 220 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR Airflow 65 45.2 0.85 22 3.07 12.0 255 126 43.9 0.81 23 3.05 11.9 253 124 40.5 0.78 24 2.98 11.6 245 121 45.4 0.71 19 3.05 11.9 253 124 67 40.7 0.65 20 2.96 11.4 243 119 44.1 0.68 20 3.03 11.8 250 123 48.2 0.69 19 3.17 12.4 266 134 46.8 0.66 20 3.14 12.3 264 132 43.2 0.63 21 3.07 12.0 256 128 48.5 0.53 15 3.14 12.3 264 132 71 43.5 0.49 16 3.05 11.9 253 127 47.1 0.51 16 3.12 12.2 261 131 MODEL: G/VSX130421B* / CA*F3642*6C* 41.3 1.00 24 3.14 12.2 252 114 40.1 0.96 25 3.11 12.1 250 113 37.0 0.93 26 3.04 11.8 242 110 40.6 0.96 23 3.11 12.1 250 113 59 36.4 0.89 24 3.02 11.7 240 109 39.4 0.92 24 3.09 12.0 247 112 44.1 0.88 23 3.30 12.9 287 133 42.8 0.84 24 3.27 12.8 284 131 39.5 0.81 24 3.20 12.5 275 127 44.3 0.74 19 3.27 12.8 284 131 67 39.7 0.68 20 3.17 12.4 273 126 43.1 0.70 20 3.25 12.7 281 130 47.1 0.71 20 3.40 13.4 299 141 45.7 0.68 20 3.37 13.3 296 140 42.2 0.66 21 3.29 12.9 287 136 47.4 0.55 15 3.37 13.3 296 140 71 42.5 0.51 16 3.27 12.8 284 134 46.0 0.52 16 3.35 13.2 293 139 40.3 1.00 24 3.32 13.3 287 119 39.2 0.99 25 3.30 13.1 284 118 36.2 0.95 26 3.22 12.8 276 114 39.6 1.00 23 3.30 13.1 284 118 59 35.5 0.91 24 3.20 12.7 273 113 38.5 0.94 24 3.27 13.0 281 116 41.1 1.00 24 3.39 13.6 309 126 39.9 0.95 25 3.36 13.5 306 125 36.9 0.92 25 3.29 13.1 297 121 43.1 0.90 23 3.49 14.0 326 138 41.8 0.86 24 3.47 13.9 323 137 38.6 0.83 24 3.39 13.5 313 132 45.9 0.73 20 3.60 14.5 340 147 44.6 0.70 20 3.58 14.4 337 145 41.2 0.67 21 3.49 14.0 327 141 39.4 1.00 23 3.49 14.2 327 125 38.2 1.00 25 3.46 14.0 324 123 35.3 0.98 26 3.38 13.6 314 120 40.1 1.00 23 3.56 14.5 352 133 39.0 0.98 25 3.53 14.4 348 131 36.0 0.95 26 3.45 14.0 338 127 42.0 0.93 23 3.67 15.0 371 145 40.8 0.89 24 3.64 14.8 368 143 37.7 0.86 24 3.55 14.4 357 139 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 36.3 38.8 41.5 34.7 35.4 37.8 0.85 0.69 0.52 0.94 0.88 0.72 23 20 16 24 23 20 3.26 3.36 3.46 3.35 3.42 3.53 13.0 13.4 13.9 13.5 13.8 14.3 294 310 323 311 334 353 120 131 140 119 126 138 39.3 42.0 44.9 37.6 38.4 41.0 0.88 0.72 0.54 0.97 0.91 0.74 20 23 20 16 24 23 3.61 3.34 3.44 3.55 3.43 3.50 13.3 13.8 14.3 13.9 14.2 14.7 303 320 333 320 345 364 124 135 144 122 130 142 40.5 43.3 46.3 38.7 39.5 42.2 0.93 0.75 0.56 1.00 0.96 0.78 22 19 15 23 22 19 3.36 3.47 3.58 3.46 3.53 3.64 13.5 13.9 14.4 14.0 14.4 14.8 306 323 337 324 348 368 125 137 145 123 131 143 NOTE: Shaded area is AHRI Rating Conditions 42.1 0.98 24 3.20 12.5 271 122 40.9 0.93 25 3.18 12.4 269 120 37.7 0.90 25 3.11 12.1 261 117 41.5 0.90 22 3.18 12.4 269 120 63 37.2 0.83 23 3.08 12.0 258 116 40.3 0.86 23 3.15 12.3 266 119 75 44.8 0.76 20 3.78 15.5 387 154 43.5 0.72 21 3.75 15.4 383 153 40.2 0.70 21 3.66 15.0 372 148 45.1 0.58 15 3.75 15.4 383 153 71 40.5 0.54 16 3.64 14.8 368 147 43.8 0.56 16 3.72 15.2 380 151 EXPANDED PERFORMANCE DATA 38.1 1.00 22 3.70 15.4 396 139 37.0 1.00 24 3.67 15.3 392 138 34.2 0.99 25 3.58 14.9 380 134 37.6 1.00 22 3.67 15.3 392 138 63 33.6 0.91 23 3.56 14.7 376 132 36.5 0.95 23 3.64 15.1 388 136 39.9 0.97 23 3.82 15.9 418 152 38.8 0.92 23 3.79 15.8 414 150 35.8 0.89 24 3.70 15.3 401 146 40.1 0.81 19 3.79 15.8 414 150 67 36.0 0.74 20 3.67 15.2 397 144 39.0 0.77 20 3.76 15.6 410 149 42.6 0.78 20 3.94 16.5 436 162 41.3 0.75 20 3.91 16.4 431 160 38.2 0.72 21 3.81 15.9 418 155 42.9 0.60 15 3.91 16.4 431 160 71 38.4 0.56 16 3.78 15.8 414 154 41.6 0.58 16 3.88 16.2 427 158 34.6 1.00 20 3.74 15.9 406 135 33.6 1.00 22 3.71 15.8 402 134 31.0 1.00 23 3.63 15.4 390 130 34.0 1.00 20 3.71 15.8 402 134 59 30.5 0.98 22 3.60 15.2 386 129 33.0 1.00 22 3.68 15.6 398 133 AMPS=outdoor unit amps (comp.+fan) 37.4 1.00 22 3.62 15.0 368 131 36.3 1.00 24 3.60 14.9 364 129 33.5 1.00 25 3.51 14.5 353 126 36.7 1.00 21 3.60 14.9 364 129 59 32.9 0.97 24 3.48 14.4 350 124 35.7 1.00 23 3.57 14.8 360 128 105 35.3 1.00 21 3.82 16.3 437 144 34.3 1.00 23 3.79 16.2 433 142 31.6 0.99 24 3.70 15.7 420 138 34.8 1.00 20 3.79 16.2 433 142 63 31.2 0.92 22 3.67 15.6 416 137 33.8 0.96 21 3.76 16.0 428 141 37.0 0.98 21 3.94 16.9 462 157 35.9 0.93 22 3.91 16.7 457 155 33.1 0.90 22 3.82 16.2 443 151 37.2 0.82 18 3.91 16.7 457 155 67 33.3 0.75 19 3.79 16.1 439 149 36.1 0.78 18 3.88 16.5 452 154 115 39.4 0.79 18 4.07 17.5 481 167 38.3 0.75 19 4.04 17.3 477 166 35.4 0.73 19 3.94 16.8 462 161 39.7 0.61 14 4.04 17.3 477 166 71 35.6 0.56 15 3.91 16.7 458 159 38.6 0.58 15 4.01 17.2 472 164 COOLING OPERATION COOLING PERFORMANCE DATA GSX130421B*/VSX130421A* 37 38 75 70 IDB* 59 40.4 0.71 19 3.17 11.6 215 104 43.8 0.73 18 3.24 12.0 221 108 45.1 0.77 18 3.26 12.1 223 109 41.1 0.81 22 3.19 11.7 217 105 44.5 0.84 21 3.26 12.1 223 109 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 45.8 0.75 20 3.33 12.4 240 116 42.3 0.72 20 3.25 12.0 233 112 45.4 0.61 16 3.30 12.3 238 114 46.7 0.64 15 3.33 12.4 240 116 63 41.9 0.59 16 3.23 11.9 231 111 49.6 0.57 16 3.42 12.8 254 126 45.8 0.55 16 3.35 12.4 246 122 49.7 0.43 12 3.40 12.7 251 125 51.2 0.45 12 3.42 12.8 254 126 67 45.9 0.41 12 3.32 12.3 244 121 53.2 0.36 11 3.53 13.2 265 134 49.1 0.35 11 3.45 12.9 257 130 - 71 - 43.5 0.87 22 3.50 13.1 251 115 40.1 0.83 22 3.42 12.7 243 111 42.7 0.76 19 3.47 12.9 248 114 44.0 0.80 18 3.50 13.0 251 115 59 39.5 0.73 19 3.39 12.6 241 110 44.8 0.77 20 3.57 13.4 270 122 41.3 0.75 20 3.49 13.0 262 118 44.3 0.64 16 3.54 13.2 267 121 45.6 0.67 16 3.57 13.4 270 122 63 40.9 0.61 16 3.46 12.9 259 117 75 48.4 0.59 16 3.68 13.8 285 133 44.7 0.56 17 3.59 13.4 276 129 48.5 0.44 12 3.65 13.7 282 132 50.0 0.46 12 3.67 13.8 285 133 67 44.8 0.42 12 3.56 13.3 274 128 52.0 0.38 11 3.79 14.3 297 142 48.0 0.36 11 3.70 13.9 288 138 - 71 - 42.4 0.89 22 3.70 14.2 285 119 39.2 0.86 22 3.62 13.8 277 116 41.7 0.78 19 3.67 14.1 282 118 43.0 0.82 18 3.70 14.2 285 119 59 38.5 0.75 19 3.59 13.7 274 115 47.3 0.60 16 3.90 15.0 324 139 43.7 0.58 17 3.80 14.6 314 134 47.4 0.45 12 3.87 14.9 321 137 48.8 0.47 12 3.90 15.0 324 139 50.8 0.39 11 4.02 15.6 338 148 46.8 0.37 11 3.92 15.1 328 143 - 45.0 48.7 52.3 0.83 0.63 0.41 19 16 11 3.81 3.93 4.05 14.7 15.1 15.7 310 327 341 128 140 149 (TVA) conditions 43.7 0.79 20 3.78 14.5 307 127 40.3 0.77 20 3.69 14.1 298 123 43.2 0.65 16 3.75 14.4 304 126 44.5 0.68 16 3.78 14.5 307 127 42.6 0.96 21 3.92 15.3 328 127 41.4 0.92 22 3.89 15.2 325 125 38.2 0.88 22 3.79 14.7 315 122 40.7 0.81 19 3.86 15.0 321 124 41.9 0.85 18 3.89 15.2 325 125 46.1 0.62 16 4.09 16.1 369 146 47.5 0.65 16 4.12 16.2 373 147 43.9 0.86 19 4.00 15.7 353 135 42.6 0.60 17 3.99 15.6 358 141 46.2 0.47 12 4.06 15.9 365 144 47.6 0.49 12 4.09 16.0 369 146 39.3 0.79 20 3.87 15.1 339 129 42.6 0.82 20 3.97 15.5 349 133 42.2 0.67 16 3.94 15.4 346 132 43.5 0.71 16 3.97 15.5 349 133 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 39.9 43.7 37.6 38.9 42.7 0.63 0.44 0.78 0.65 0.45 16 13 19 17 13 3.66 3.77 3.77 3.84 3.96 14.0 14.5 14.6 15.0 15.5 295 311 312 336 354 122 133 120 128 140 51.0 0.42 11 4.26 16.8 389 157 49.5 0.40 11 4.22 16.7 385 155 45.7 0.38 12 4.12 16.2 373 150 - 71 - EXPANDED PERFORMANCE DATA MBh 45.8 47.2 51.1 54.8 44.8 46.1 49.9 53.6 43.7 S/T 0.88 0.78 0.59 0.38 0.91 0.81 0.61 0.40 0.93 Delta T 21 19 15 11 21 19 16 11 21 1800 KW 3.29 3.35 3.45 3.55 3.52 3.59 3.70 3.82 3.73 AMPS 12.2 12.5 12.9 13.4 13.2 13.5 13.9 14.5 14.3 HI PR 226 243 256 267 253 272 288 300 288 LO PR 110 117 127 136 116 123 135 143 120 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA High and low pressures are measured at the liquid and suction service valves. 1600 1400 1800 1600 1400 Airflow 65 MODEL: GSX130481B* / CA*F4860*6B* 40.5 0.85 20 4.13 16.5 393 140 37.4 0.82 20 4.03 16.1 381 136 40.1 0.70 16 4.09 16.4 389 138 41.3 0.73 15 4.13 16.5 393 140 63 37.0 0.67 16 4.00 15.9 377 134 43.8 0.64 16 4.26 17.1 415 153 40.5 0.62 16 4.15 16.6 403 148 43.9 0.48 12 4.22 16.9 411 151 45.2 0.51 12 4.26 17.1 415 152 67 40.5 0.47 12 4.12 16.5 399 146 47.0 0.41 11 4.39 17.7 433 162 43.4 0.40 11 4.29 17.2 420 158 - 71 - 36.4 0.96 20 4.18 17.1 404 136 33.6 0.92 20 4.08 16.6 391 132 35.8 0.84 17 4.14 16.9 400 134 36.9 0.88 17 4.18 17.1 404 136 59 33.1 0.81 18 4.04 16.5 388 130 37.5 0.86 18 4.26 17.5 434 145 34.6 0.83 19 4.16 17.0 421 140 37.1 0.70 15 4.23 17.4 430 143 38.2 0.74 14 4.26 17.5 434 144 63 34.3 0.68 15 4.13 16.9 417 139 41.8 0.68 15 4.44 18.3 463 159 40.6 0.65 15 4.40 18.1 459 158 37.5 0.63 15 4.29 17.6 445 153 40.7 0.49 11 4.36 17.9 454 156 41.9 0.51 11 4.40 18.1 459 158 67 37.5 0.47 12 4.26 17.4 440 151 115 40.5 41.7 45.1 48.5 37.5 38.6 1.00 0.89 0.67 0.43 1.00 0.90 21 19 16 11 19 18 4.07 4.16 4.29 4.43 4.21 4.30 16.3 16.7 17.2 17.9 17.3 17.7 369 397 419 437 408 439 133 141 154 164 137 146 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 39.3 0.95 21 4.04 16.1 365 131 36.3 0.92 22 3.95 15.7 354 127 38.7 0.84 19 4.01 16.0 362 130 39.8 0.88 18 4.04 16.1 365 131 59 35.7 0.81 19 3.91 15.5 351 126 105 44.9 0.44 10 4.58 19.0 483 170 43.6 0.42 10 4.54 18.8 478 168 40.2 0.40 11 4.43 18.3 464 163 - 71 - CO OLING O PERATION COOLING PERFORMANCE DATA GSX130481B*/VSX130481A* 85 80 IDB* 59 41.8 0.88 24 3.21 11.9 219 106 45.3 0.92 24 3.29 12.2 226 110 46.7 0.96 23 3.31 12.3 228 111 42.5 0.93 26 3.24 12.0 221 108 46.1 0.96 25 3.31 12.3 228 111 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 43.4 0.89 25 3.30 12.2 238 114 47.0 0.93 25 3.38 12.6 245 118 63 42.7 0.83 23 3.28 12.1 236 113 46.3 0.86 23 3.35 12.5 243 117 47.7 0.90 22 3.38 12.6 245 118 45.4 0.81 24 3.40 12.6 251 125 49.2 0.84 24 3.48 13.0 259 129 67 45.6 0.67 20 3.37 12.5 249 124 49.5 0.70 20 3.45 12.9 256 127 50.9 0.73 19 3.48 13.0 259 129 48.5 0.65 21 3.50 13.1 262 133 52.5 0.68 20 3.58 13.5 270 137 71 48.8 0.50 16 3.47 13.0 259 132 52.9 0.52 16 3.56 13.4 267 136 54.4 0.55 15 3.58 13.5 270 137 41.5 0.96 26 3.47 12.9 248 114 45.0 1.00 26 3.55 13.3 256 117 59 40.8 0.92 25 3.44 12.8 246 112 44.2 0.95 24 3.52 13.2 253 116 45.6 1.00 23 3.55 13.3 256 117 42.4 0.93 26 3.54 13.2 267 121 45.9 0.96 25 3.62 13.6 275 125 63 41.7 0.86 24 3.51 13.1 264 120 45.2 0.89 23 3.59 13.5 272 123 46.6 0.93 22 3.62 13.6 275 125 75 44.4 0.84 24 3.65 13.7 282 132 48.1 0.87 24 3.73 14.1 291 136 67 44.6 0.70 20 3.62 13.6 279 131 48.3 0.72 20 3.70 13.9 288 135 49.7 0.76 19 3.73 14.1 291 136 47.3 0.68 21 3.76 14.2 294 140 51.3 0.70 21 3.85 14.6 303 145 71 47.7 0.52 16 3.73 14.1 291 139 51.6 0.54 16 3.82 14.5 300 143 53.2 0.57 15 3.85 14.6 303 145 40.6 0.98 26 3.67 14.0 282 118 43.9 1.00 25 3.76 14.4 291 122 59 39.9 0.94 25 3.65 13.9 279 117 43.2 0.97 24 3.73 14.3 288 120 44.5 1.00 23 3.76 14.4 291 122 43.3 0.86 24 3.86 14.9 321 137 46.9 0.89 24 3.96 15.3 331 141 46.2 0.70 21 3.99 15.4 334 146 50.1 0.72 21 4.08 15.9 345 151 46.1 48.3 51.6 1.00 0.93 0.76 24 23 20 3.87 3.99 4.11 14.9 15.4 16.0 316 334 348 131 143 152 Rating Conditions 41.3 0.95 26 3.75 14.4 304 126 44.8 0.98 25 3.84 14.8 313 129 44.2 1.00 23 3.98 15.6 335 129 39.6 1.00 26 3.85 15.0 321 124 42.9 1.00 25 3.95 15.4 331 128 45.0 1.00 23 4.06 16.0 360 137 40.3 0.98 26 3.94 15.4 346 132 43.7 1.00 25 4.03 15.8 356 136 47.1 0.96 23 4.19 16.5 380 150 42.2 0.88 25 4.06 15.9 365 144 45.8 0.92 24 4.16 16.4 376 148 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 40.7 43.5 46.5 38.9 39.7 42.5 0.88 0.72 0.54 0.97 0.91 0.74 24 20 16 25 24 21 3.72 3.83 3.95 3.82 3.90 4.03 14.3 14.7 15.3 14.9 15.2 15.8 301 317 331 318 342 362 124 136 145 123 131 143 44.1 47.2 50.4 42.1 43.1 46.0 0.91 0.74 0.56 1.00 0.94 0.77 20 23 20 16 24 23 4.12 3.81 3.93 4.05 3.92 4.00 14.7 15.2 15.7 15.3 15.7 16.2 310 327 341 328 353 373 128 140 149 127 135 147 44.3 47.4 45.5 48.6 51.9 43.4 0.96 0.78 0.58 1.00 1.00 0.80 22 19 15 22 23 19 3.84 3.96 4.08 3.95 4.03 4.16 14.8 15.3 15.9 15.4 15.8 16.4 313 331 345 331 356 376 129 141 151 128 136 148 50.3 0.78 20 4.32 17.1 397 160 45.1 0.72 21 4.19 16.5 381 153 48.8 0.74 21 4.29 17.0 393 158 71 45.4 0.55 16 4.15 16.3 377 152 49.2 0.57 16 4.26 16.8 389 157 50.6 0.60 16 4.29 17.0 393 158 EXPANDED PERFORMANCE DATA MBh 47.5 48.4 50.7 54.1 46.4 47.3 49.5 52.8 45.3 S/T 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 Delta T 24 24 23 20 24 24 23 20 23 1800 KW 3.34 3.40 3.50 3.61 3.58 3.65 3.76 3.88 3.79 AMPS 12.4 12.7 13.1 13.6 13.4 13.7 14.2 14.7 14.6 HI PR 230 248 262 273 258 278 294 306 294 LO PR 112 119 130 138 118 126 137 146 123 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI High and low pressures are measured at the liquid and suction service valves. 1600 1400 1800 1600 1400 Airflow 65 MODEL: GSX130481B* / CA*F4860*6B* 38.3 1.00 25 4.09 16.4 389 138 41.5 1.00 24 4.19 16.8 401 143 63 37.8 0.94 23 4.06 16.2 385 137 40.9 0.98 23 4.16 16.7 397 141 42.1 1.00 22 4.19 16.8 401 143 40.1 0.92 24 4.22 16.9 411 151 43.5 0.95 24 4.33 17.4 423 156 67 40.3 0.77 20 4.19 16.8 407 149 43.7 0.80 20 4.29 17.3 419 154 45.0 0.83 19 4.33 17.4 423 156 42.8 0.74 21 4.36 17.6 428 161 46.4 0.77 21 4.47 18.1 442 166 71 43.1 0.57 16 4.32 17.4 424 159 46.7 0.60 16 4.43 17.9 437 164 48.1 0.62 15 4.47 18.1 442 166 34.8 1.00 23 4.14 16.9 399 134 37.7 1.00 22 4.24 17.4 412 139 59 34.2 1.01 23 4.11 16.8 395 133 37.1 1.00 21 4.21 17.3 408 137 38.2 1.00 20 4.24 17.4 412 139 35.5 1.00 23 4.23 17.4 430 143 38.5 1.00 22 4.33 17.9 443 147 63 35.0 0.95 22 4.20 17.2 426 142 37.9 0.99 21 4.30 17.7 439 146 39.0 1.00 20 4.33 17.9 443 147 41.5 1.00 21 4.51 18.6 473 163 37.2 0.93 23 4.36 17.9 454 156 40.3 0.96 22 4.47 18.5 468 161 67 37.4 0.77 19 4.33 17.8 449 155 40.5 0.80 19 4.44 18.3 463 159 41.7 0.84 18 4.47 18.5 468 161 115 42.0 42.8 44.8 47.8 38.9 39.6 1.00 1.00 1.00 0.81 1.00 1.00 21 22 23 20 20 20 4.14 4.23 4.36 4.50 4.28 4.37 16.6 17.0 17.6 18.2 17.6 18.0 376 405 428 446 416 448 135 144 157 167 140 149 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 37.6 1.00 25 4.01 16.0 361 130 40.7 1.00 23 4.11 16.4 373 134 59 36.9 1.01 24 3.98 15.8 358 129 40.0 1.00 23 4.07 16.3 369 133 41.2 1.00 21 4.11 16.4 373 134 105 44.3 0.82 18 4.65 19.3 493 173 39.7 0.75 20 4.50 18.6 473 166 43.0 0.78 19 4.62 19.2 488 171 71 39.9 0.58 15 4.47 18.5 469 165 43.3 0.60 15 4.58 19.0 483 170 44.6 0.63 14 4.62 19.2 488 171 COOLING O PERATION COOLING PERFORMANCE DATA GSX130481B*/VSX130481A* 39 40 75 70 IDB* 59 50.1 0.67 21 3.87 14.4 229 101 54.2 0.69 20 3.96 14.8 236 105 55.9 0.73 19 3.99 15.0 238 106 50.9 0.76 24 3.90 14.6 231 103 55.1 0.79 23 3.99 15.0 238 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 56.8 0.71 21 4.07 15.3 256 112 52.4 0.68 22 3.98 14.9 249 109 63 51.9 0.56 18 3.95 14.8 246 108 56.2 0.58 17 4.04 15.2 254 111 57.9 0.61 16 4.07 15.3 256 112 61.5 0.53 17 4.20 15.8 271 123 56.7 0.51 18 4.10 15.4 263 119 67 56.8 0.39 13 4.07 15.3 260 118 61.6 0.40 13 4.17 15.7 268 122 63.4 0.42 12 4.20 15.8 271 123 66.0 0.34 12 4.33 16.4 282 131 60.9 0.33 12 4.23 16.0 274 127 71 - 53.9 0.82 23 4.29 16.2 267 112 49.7 0.79 24 4.19 15.8 259 108 59 48.9 0.69 21 4.16 15.6 257 107 53.0 0.72 20 4.26 16.1 265 111 54.6 0.75 19 4.29 16.2 267 112 55.5 0.73 21 4.38 16.6 288 119 51.2 0.70 22 4.28 16.1 279 115 63 50.7 0.58 18 4.24 16.0 276 114 54.9 0.60 17 4.35 16.4 285 118 56.5 0.63 16 4.38 16.6 288 119 75 60.0 0.55 17 4.52 17.2 304 130 55.4 0.53 18 4.41 16.7 295 126 67 55.5 0.40 14 4.38 16.5 292 125 60.1 0.42 13 4.48 17.0 301 128 62.0 0.44 12 4.52 17.2 304 130 64.4 0.36 12 4.66 17.8 317 138 59.5 0.34 13 4.55 17.3 307 134 71 - 52.6 0.84 23 4.56 17.6 304 116 48.5 0.81 24 4.45 17.1 295 113 59 47.7 0.71 21 4.41 17.0 292 111 51.7 0.74 20 4.52 17.5 301 115 53.3 0.77 19 4.56 17.6 304 116 58.6 0.57 17 4.80 18.7 346 135 54.1 0.55 18 4.68 18.1 335 131 62.9 0.36 12 4.96 19.4 360 144 58.1 0.35 13 4.84 18.8 350 139 55.8 60.4 64.8 0.79 0.59 0.38 20 16 11 4.69 4.84 5.00 18.2 18.8 19.6 331 349 364 125 136 145 (TVA) conditions 54.1 0.75 21 4.65 18.1 327 123 50.0 0.72 22 4.54 17.6 317 120 52.8 0.91 22 4.83 19.0 350 123 51.3 0.86 23 4.79 18.9 346 122 47.3 0.83 24 4.67 18.3 336 118 57.2 0.59 18 5.05 20.0 394 142 52.8 0.77 21 4.89 19.3 373 130 54.4 0.81 20 4.93 19.5 376 131 58.9 0.61 17 5.09 20.2 398 143 52.8 0.56 18 4.93 19.4 382 137 48.8 0.75 22 4.77 18.8 362 126 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 49.5 54.2 46.6 48.3 52.9 0.59 0.41 0.73 0.61 0.42 18 14 21 18 14 4.50 4.65 4.63 4.73 4.89 17.4 18.0 18.2 18.6 19.2 314 332 333 358 378 119 129 117 125 136 53.6 58.7 50.4 52.3 57.3 0.62 0.43 0.76 0.64 0.44 17 13 20 17 13 4.62 4.76 4.75 4.85 5.01 17.9 18.5 18.7 19.1 19.8 324 342 343 369 390 122 133 121 128 140 55.2 60.5 52.0 53.9 59.0 0.65 0.45 0.80 0.67 0.46 16 12 19 16 13 4.65 4.80 4.79 4.89 5.05 18.1 18.7 18.9 19.3 20.0 327 346 346 373 394 123 135 122 130 142 63.2 0.39 11 5.26 20.9 415 152 61.4 0.38 12 5.22 20.8 411 151 56.6 0.36 13 5.09 20.2 398 146 71 - EXPANDED PERFORMANCE DATA MBh 56.8 58.5 63.3 67.9 55.5 57.1 61.8 66.4 54.2 S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 Delta T 22 20 16 11 22 20 16 11 22 2000 KW 4.02 4.11 4.23 4.37 4.33 4.42 4.56 4.70 4.59 AMPS 15.1 15.5 16.0 16.6 16.4 16.8 17.3 18.0 17.8 HI PR 241 259 274 285 270 291 307 320 307 LO PR 107 114 124 132 113 120 131 139 117 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA High and low pressures are measured at the liquid and suction service valves. 1750 1500 2000 1750 1500 Airflow 65 MODEL: GSX130601B* / CA*F4961*6A* 50.2 0.80 21 5.10 20.6 419 136 46.3 0.77 22 4.97 20.0 407 132 63 45.8 0.64 18 4.93 19.8 403 130 49.7 0.66 17 5.05 20.4 415 135 51.2 0.69 16 5.10 20.6 419 136 54.3 0.61 17 5.26 21.3 443 148 50.1 0.59 18 5.13 20.7 430 144 67 50.2 0.44 14 5.09 20.5 425 142 54.4 0.46 13 5.22 21.1 438 147 56.1 0.48 12 5.26 21.3 443 148 58.3 0.39 12 5.44 22.1 462 158 53.8 0.38 12 5.30 21.5 448 153 71 - 45.1 0.91 21 5.16 21.3 431 132 41.7 0.87 22 5.03 20.7 418 128 59 41.0 0.77 19 4.99 20.5 413 127 44.4 0.80 19 5.12 21.1 426 131 45.7 0.83 18 5.16 21.3 430 132 46.5 0.81 20 5.27 21.8 463 141 42.9 0.78 21 5.14 21.2 449 136 63 42.5 0.64 17 5.10 21.0 445 135 46.0 0.66 16 5.23 21.6 459 139 47.4 0.70 15 5.27 21.8 463 141 51.8 0.64 15 5.49 22.8 494 155 50.3 0.61 16 5.44 22.6 489 153 46.4 0.59 17 5.31 21.9 475 149 67 46.5 0.44 13 5.26 21.7 470 147 50.4 0.46 12 5.40 22.4 484 152 51.9 0.48 12 5.44 22.6 489 153 115 50.2 51.7 55.9 60.0 46.5 47.9 0.94 0.84 0.64 0.41 0.95 0.85 22 20 16 11 20 19 5.03 5.14 5.31 5.48 5.20 5.32 20.3 20.8 21.5 22.3 21.5 22.0 394 424 447 466 435 468 129 137 150 160 133 142 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 48.7 0.90 23 4.99 20.1 390 128 45.0 0.87 24 4.86 19.5 378 124 59 44.2 0.76 21 4.82 19.3 374 123 47.9 0.79 20 4.95 19.9 386 126 49.4 0.83 19 4.99 20.1 390 128 105 55.6 0.41 11 5.67 23.7 515 165 54.0 0.39 11 5.63 23.5 510 163 49.8 0.38 12 5.48 22.8 495 159 71 - CO OLING O PERATION COOLING PERFORMANCE DATA GSX130601B*/VSX130601B* 85 80 IDB* 56.1 0.86 25 4.02 15.1 241 107 57.8 0.91 24 4.05 15.2 243 108 52.7 0.87 28 3.96 14.8 236 105 57.1 0.91 27 4.05 15.2 243 108 58.8 0.95 26 4.09 15.4 246 109 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1750 2000 63 60.0 0.92 25 4.17 15.8 264 116 58.2 0.87 27 4.14 15.6 262 115 53.7 0.84 28 4.04 15.2 254 111 57.4 0.81 24 4.11 15.5 259 114 59.1 0.85 23 4.14 15.6 262 115 52.9 0.78 25 4.01 15.1 251 110 67 62.8 0.83 24 4.30 16.3 279 126 61.0 0.79 25 4.27 16.1 276 125 56.3 0.76 26 4.17 15.7 268 121 61.3 0.66 21 4.23 16.0 274 124 63.1 0.69 20 4.27 16.1 276 125 56.6 0.64 22 4.13 15.6 265 120 71 67.0 0.67 21 4.44 16.9 291 135 65.0 0.64 22 4.40 16.7 288 133 60.0 0.62 23 4.30 16.3 280 129 65.5 0.49 17 4.37 16.6 285 132 67.5 0.52 16 4.40 16.7 288 133 60.5 0.48 18 4.26 16.1 277 128 59 57.5 0.99 26 4.39 16.7 276 115 55.8 0.94 28 4.36 16.5 273 114 51.5 0.91 29 4.26 16.0 265 110 54.8 0.90 26 4.33 16.4 270 113 56.5 0.94 24 4.36 16.5 273 114 50.6 0.86 27 4.22 15.9 262 109 63 58.6 0.95 26 4.49 17.1 297 122 56.9 0.91 27 4.45 16.9 294 121 52.5 0.87 28 4.35 16.4 285 118 56.0 0.84 25 4.42 16.8 291 120 57.7 0.88 23 4.45 16.9 294 121 51.7 0.81 26 4.31 16.3 282 116 75 67 61.3 0.86 24 4.63 17.6 313 134 59.6 0.82 26 4.59 17.5 310 132 55.0 0.79 27 4.48 17.0 301 128 59.9 0.68 22 4.56 17.3 307 131 61.6 0.72 20 4.59 17.5 310 132 55.2 0.66 22 4.45 16.8 298 127 71 65.4 0.70 21 4.78 18.3 327 142 63.5 0.66 22 4.74 18.1 323 141 58.6 0.64 23 4.62 17.6 314 137 64.0 0.51 17 4.70 18.0 320 140 65.9 0.54 16 4.74 18.1 323 141 59.1 0.49 18 4.59 17.5 311 135 59 56.1 1.00 26 4.67 18.1 313 120 54.5 0.96 28 4.63 18.0 310 118 50.3 0.93 29 4.52 17.5 301 115 53.5 0.92 26 4.59 17.8 307 117 55.1 0.96 24 4.63 18.0 310 118 49.4 0.89 27 4.48 17.3 298 114 57.2 0.97 26 4.77 18.6 337 127 55.5 0.93 27 4.73 18.4 334 126 51.2 0.90 28 4.61 17.9 324 122 54.7 0.86 25 4.69 18.2 331 125 56.3 0.90 23 4.73 18.4 334 126 50.5 0.83 26 4.58 17.7 321 121 59.9 0.88 24 4.92 19.2 356 139 58.1 0.84 26 4.88 19.0 353 137 53.7 0.81 27 4.76 18.5 342 133 58.4 0.70 22 4.84 18.8 349 136 60.2 0.74 20 4.88 19.0 353 137 53.9 0.68 22 4.72 18.3 339 132 63.9 0.71 21 5.08 19.9 371 148 62.0 0.68 22 5.04 19.8 368 146 57.2 0.66 23 4.92 19.2 357 142 62.5 0.52 17 5.00 19.6 364 145 64.3 0.55 16 5.04 19.8 368 146 57.6 0.51 18 4.88 19.0 353 141 54.7 1.00 25 4.91 19.4 357 126 53.1 0.99 28 4.87 19.2 353 124 49.0 0.96 29 4.75 18.7 343 121 52.2 0.95 26 4.83 19.0 350 123 53.8 1.00 25 4.87 19.2 353 124 48.2 0.91 27 4.71 18.5 339 119 55.8 1.00 26 5.01 19.9 384 134 54.2 0.96 27 4.97 19.7 380 132 50.0 0.93 28 4.85 19.1 369 128 53.4 0.89 25 4.93 19.5 377 131 55.0 0.93 24 4.97 19.7 380 132 49.2 0.86 26 4.81 19.0 365 127 58.4 0.91 24 5.18 20.6 406 146 56.7 0.87 26 5.13 20.4 402 144 52.3 0.83 27 5.01 19.8 390 140 57.0 0.72 22 5.09 20.2 398 143 58.7 0.76 20 5.13 20.4 402 144 52.6 0.70 23 4.97 19.6 386 139 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 62.3 0.74 21 5.35 21.3 423 155 60.5 0.70 22 5.30 21.1 419 154 55.8 0.68 23 5.17 20.5 406 149 60.9 0.54 17 5.26 20.9 415 152 62.8 0.57 16 5.30 21.1 419 154 56.2 0.52 18 5.13 20.4 402 148 71 EXPANDED PERFORMANCE DATA * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 1500 2000 1750 1500 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 59 51.8 0.83 26 3.93 14.7 234 104 MBh S/T Delta T KW AMPS HI PR LO PR Airflow 65 MODEL: GSX130601B* / CA*F4961*6A* 59 63 53.0 1.00 24 5.22 21.2 432 140 51.4 1.00 27 5.18 21.0 428 139 47.5 0.96 28 5.05 20.4 415 134 50.7 0.92 25 5.14 20.8 424 137 52.2 0.97 23 5.18 21.0 428 139 46.8 0.89 26 5.01 20.2 411 133 67 55.5 0.94 24 5.39 21.9 456 153 53.9 0.90 25 5.35 21.7 452 151 49.7 0.87 26 5.22 21.1 438 147 54.2 0.75 21 5.31 21.5 447 150 55.8 0.79 20 5.35 21.7 452 151 50.0 0.72 22 5.17 20.9 434 145 71 59.2 0.76 21 5.57 22.7 476 163 57.5 0.73 22 5.53 22.5 471 161 53.1 0.70 23 5.39 21.9 457 156 57.9 0.56 17 5.48 22.3 467 160 59.6 0.59 16 5.53 22.5 471 161 53.4 0.54 18 5.34 21.7 453 155 59 48.2 1.00 22 5.29 21.9 444 136 46.7 1.00 25 5.24 21.7 439 135 43.1 1.00 26 5.11 21.1 426 131 45.9 0.99 24 5.20 21.5 435 133 47.3 1.00 22 5.24 21.7 439 135 42.4 0.96 25 5.07 20.9 422 129 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 52.0 1.00 24 5.11 20.7 402 132 50.5 1.00 27 5.07 20.5 398 130 46.6 1.00 28 4.94 19.9 386 126 49.6 0.98 26 5.03 20.3 394 129 51.1 1.00 23 5.07 20.5 398 130 45.8 0.95 27 4.90 19.7 382 125 105 63 49.1 1.00 23 5.40 22.5 477 145 47.7 1.00 25 5.36 22.3 473 143 44.0 0.97 26 5.23 21.6 459 139 46.9 0.93 23 5.32 22.0 468 142 48.4 1.00 22 5.36 22.3 473 143 43.3 0.90 24 5.18 21.4 454 138 67 51.4 0.95 22 5.58 23.2 504 158 49.9 0.91 24 5.54 23.0 499 157 46.1 0.87 25 5.40 22.4 484 152 50.2 0.76 20 5.49 22.8 494 155 51.7 0.79 19 5.54 23.0 499 157 46.3 0.73 21 5.35 22.2 479 150 115 54.8 0.77 19 5.77 24.1 526 168 53.2 0.74 21 5.72 23.9 521 167 49.1 0.71 21 5.58 23.2 505 162 53.6 0.57 16 5.67 23.7 515 165 55.2 0.59 15 5.72 23.9 521 167 49.5 0.55 17 5.53 23.0 500 160 71 COOLING O PERATION COOLING PERFORMANCE DATA GSX130601B*/VSX130601B* 41 42 75 70 IDB* 234 107 31.6 0.79 22 HI PR LO PR MBh S/T Delta T 63 22 S/T Delta T 21 S/T Delta T 6.4 236 108 A MPS HI PR LO PR 2.52 0.77 0.86 MBh KW 36.3 107 35.3 LO PR 6.5 115 254 6.5 2.57 19 114 252 6.3 234 HI PR 2.55 20 111 A MPS 2.50 0.73 0.82 MBh KW 35.3 104 34.2 LO PR 6.3 244 6.2 227 HI PR 2.49 20 0.71 32.5 114 252 6.5 2.55 15 0.63 36.0 113 249 6.4 2.53 16 0.60 34.9 109 242 6.3 2.47 16 0.58 32.2 A MPS 2.44 6.3 KW 2.50 18 Delta T KW 0.76 S/T A MPS 106 34.7 231 HI PR MBh 6.3 LO PR 2.48 19 Delta T KW 0.72 S/T A MPS 103 33.7 224 HI PR MBh 6.1 LO PR 2.42 KW 19 Delta T A MPS 0.70 S/T 59 31.1 MBh 67 280 134 126 7.0 2.72 11 0.37 42.2 133 277 6.9 2.70 11 0.36 41.0 129 269 6.7 2.64 11 0.34 37.8 - - - - - - - - - - - - - - - - - - - - - 71 268 6.7 2.64 16 0.58 39.3 124 266 6.7 2.62 16 0.56 38.2 121 258 6.5 2.56 17 0.54 35.2 124 266 6.7 2.62 12 0.44 39.4 123 263 6.6 2.60 12 0.42 38.2 120 255 6.5 2.54 12 0.40 35.3 59 114 265 6.9 2.70 21 0.89 34.5 113 262 6.8 2.68 22 0.85 33.5 110 254 6.6 2.62 22 0.82 30.9 113 262 6.8 2.68 18 0.78 33.9 112 260 6.8 2.66 19 0.75 32.9 109 252 6.6 2.60 19 0.72 30.4 63 67 133 301 7.3 2.84 16 0.60 38.4 131 298 7.2 2.82 16 0.58 37.3 128 289 7.0 2.75 17 0.55 34.4 131 298 7.2 2.81 12 0.45 38.5 130 295 7.1 2.79 12 0.43 37.4 126 286 7.0 2.73 13 0.42 34.5 141 314 7.5 2.92 11 0.39 41.2 140 311 7.5 2.90 11 0.37 40.0 136 302 7.3 2.83 12 0.36 36.9 - - - - - - - - - - - - - - - - - - - - - 71 59 119 301 7.5 2.86 21 0.91 33.6 118 298 7.4 2.84 22 0.87 32.7 114 289 7.2 2.77 22 0.84 30.1 118 298 7.4 2.84 18 0.80 33.1 116 295 7.3 2.81 19 0.77 32.1 113 286 7.1 2.75 19 0.74 29.6 126 324 7.6 2.92 19 0.82 34.6 125 321 7.6 2.90 20 0.78 33.6 121 311 7.4 2.83 20 0.75 31.0 125 321 7.6 2.90 16 0.67 34.3 124 318 7.5 2.87 16 0.64 33.3 120 308 7.3 2.81 17 0.62 30.7 63 138 342 7.9 3.01 16 0.62 37.5 137 339 7.8 2.98 16 0.59 36.4 133 329 7.6 2.91 17 0.57 33.6 137 339 7.8 2.98 12 0.47 37.6 135 336 7.7 2.96 12 0.44 36.5 131 326 7.5 2.89 13 0.43 33.7 67 147 357 8.2 3.10 11 0.40 40.2 146 354 8.1 3.08 11 0.38 39.1 141 343 7.9 3.01 12 0.37 36.1 - - - - - - - - - - - - - - - - - - - - - 71 125 343 8.0 3.00 21 0.94 32.8 124 340 7.9 2.98 22 0.90 31.9 120 330 7.7 2.91 22 0.87 29.4 124 340 7.9 2.98 18 0.83 32.3 122 336 7.8 2.95 19 0.79 31.3 119 326 7.6 2.88 19 0.76 28.9 59 133 369 8.1 3.06 19 0.84 33.8 131 366 8.1 3.04 20 0.80 32.8 128 355 7.9 2.97 21 0.78 30.3 131 366 8.1 3.04 16 0.69 33.4 130 362 8.0 3.02 16 0.66 32.5 126 351 7.8 2.94 17 0.64 30.0 63 67 145 390 8.4 3.16 16 0.64 36.6 144 386 8.3 3.13 17 0.61 35.5 139 375 8.1 3.06 17 0.59 32.8 144 386 8.3 3.13 12 0.48 36.6 142 382 8.3 3.11 12 0.46 35.6 138 371 8.0 3.04 13 0.44 32.8 Ente r ing Indoor We t Bulb Te m pe rature 95 Outdoor Am bie nt Te m pe rature 85 NOTE: Shaded area is A CCA (TV A ) conditions 122 285 7.0 2.75 19 0.80 35.5 120 282 7.0 2.73 20 0.76 34.4 117 274 6.8 2.67 20 0.73 31.8 120 282 7.0 2.73 16 0.65 35.1 119 279 6.9 2.71 16 0.62 34.1 116 271 6.7 2.65 17 0.60 31.5 75 EXPANDED PERFORM ANCE DATA High and low pressures are measured at the liquid and suction service valves. * Entering Indoor Dry Bulb Temperature 1350 1200 1050 1350 1200 1050 Airflow 65 MODEL: GSX130363 A* / CA*F3636*6C* 154 407 8.7 3.26 11 0.41 39.3 153 403 8.6 3.23 11 0.39 38.1 148 391 8.4 3.16 12 0.38 35.2 - - - - - - - - - - - - - - - - - - - - - 71 59 63 139 415 8.7 3.19 19 0.88 32.1 138 411 8.6 3.16 20 0.83 31.2 134 399 8.3 3.09 20 0.81 28.8 138 411 8.6 3.16 16 0.72 31.8 136 407 8.5 3.14 16 0.69 30.8 132 395 8.3 3.06 16 0.66 28.5 67 152 439 8.9 3.29 16 0.66 34.7 150 434 8.9 3.26 16 0.63 33.7 146 421 8.6 3.18 17 0.61 31.1 150 434 8.9 3.26 12 0.50 34.8 149 430 8.8 3.24 12 0.48 33.8 144 417 8.5 3.16 13 0.46 31.2 162 458 9.3 3.39 11 0.43 37.3 160 453 9.2 3.37 11 0.41 36.2 155 439 8.9 3.29 11 0.39 33.4 - - - - - - - - - - - - - - - - - - - - - 71 59 135 427 8.9 3.23 19 0.99 28.9 134 422 8.9 3.20 20 0.94 28.0 130 410 8.6 3.12 21 0.91 25.9 134 422 8.9 3.20 17 0.87 28.4 133 418 8.8 3.17 17 0.83 27.6 129 406 8.5 3.10 18 0.80 25.4 63 144 459 9.2 3.29 18 0.88 29.7 143 454 9.1 3.27 19 0.84 28.9 138 441 8.8 3.19 19 0.81 26.6 143 454 9.1 3.27 15 0.73 29.4 141 450 9.0 3.24 15 0.69 28.6 137 436 8.7 3.16 15 0.67 26.4 AMPS=outdoor unit amps (comp.+fan) KW =Total system power 131 386 8.5 3.12 21 0.98 31.2 130 382 8.4 3.10 22 0.93 30.3 126 371 8.2 3.02 22 0.90 27.9 130 382 8.4 3.10 18 0.86 30.7 128 378 8.3 3.07 19 0.82 29.8 124 367 8.1 3.00 19 0.79 27.5 105 115 157 485 9.5 3.40 15 0.67 32.2 156 480 9.4 3.37 15 0.64 31.2 151 466 9.1 3.29 16 0.61 28.8 156 480 9.4 3.37 11 0.50 32.2 154 475 9.3 3.34 11 0.48 31.3 149 461 9.0 3.26 12 0.46 28.9 67 167 506 9.8 3.51 10 0.43 34.5 166 501 9.7 3.48 11 0.41 33.5 161 486 9.5 3.40 11 0.40 31.0 - - - - - - - - - - - - - - - - - - - - - 71 COOLING OPERATION COOLING PERFORMANCE DATA GSX130363A* 85 80 IDB* 35.6 0.84 105 34.9 0.90 24 LO PR MBh S/T Delta T 6.4 0.94 23 S/T Delta T 32.7 0.91 26 LO PR MBh S/T Delta T 0.91 0.94 26 MBh S/T Delta T 25 Delta T 6.5 241 110 AMPS HI PR LO PR 2.55 0.99 S/T KW 36.5 MBh 117 259 6.7 2.61 24 0.95 37.2 116 257 238 109 HI PR 2.59 6.6 25 113 2.54 6.4 LO PR KW AMPS 36.2 106 35.5 LO PR 6.4 249 6.3 231 HI PR 2.53 26 0.88 33.4 116 257 6.6 2.59 22 115 AMPS 2.48 109 HI PR KW 6.4 238 AMPS 2.54 0.88 35.9 MBh KW 36.7 108 LO PR 254 236 HI PR 2.57 6.5 2.52 6.4 KW AMPS 23 112 246 6.2 229 HI PR 2.51 AMPS 2.46 KW 24 23 0.81 0.87 S/T Delta T 63 32.9 59 32.2 MBh 67 128 274 6.9 2.68 23 0.86 39.0 127 271 2.66 6.8 24 0.82 37.9 123 263 6.6 2.60 24 0.79 34.9 127 271 6.8 2.66 19 0.72 39.2 126 268 2.64 6.7 20 0.69 38.1 122 260 6.6 2.58 20 0.66 35.1 71 137 285 7.1 2.76 20 0.70 41.6 135 283 2.74 7.0 21 0.67 40.4 131 274 6.9 2.68 21 0.64 37.3 135 283 7.0 2.74 15 0.54 41.9 134 280 2.72 7.0 16 0.51 40.7 130 271 6.8 2.66 16 0.49 37.5 59 117 270 7.0 2.74 24 1.00 35.7 116 268 2.72 6.9 26 0.98 34.6 112 260 6.8 2.66 26 0.94 32.0 116 268 6.9 2.72 24 1.00 35.1 114 265 2.70 6.9 24 0.93 34.0 111 257 6.7 2.64 25 0.90 31.4 63 67 135 307 7.4 2.88 23 0.89 38.1 134 304 2.86 7.3 24 0.85 37.0 130 295 7.1 2.79 25 0.82 34.1 134 304 7.3 2.86 19 0.75 38.3 133 301 2.84 7.3 20 0.71 37.2 129 292 7.1 2.77 21 0.69 34.3 71 144 320 7.7 2.97 20 0.72 40.6 143 317 2.95 7.6 21 0.69 39.5 139 308 7.4 2.88 21 0.67 36.4 143 317 7.6 2.95 16 0.56 40.9 141 314 2.93 7.5 16 0.53 39.7 137 305 7.3 2.86 16 0.51 36.7 59 121 307 7.6 2.90 24 1.00 34.8 120 304 2.88 7.5 26 1.00 33.8 116 295 7.3 2.81 26 0.97 31.2 120 304 7.5 2.88 23 1.00 34.2 119 301 2.86 7.5 24 0.96 33.2 115 292 7.3 2.79 25 0.92 30.7 Outdoor Ambient Temperature 129 331 7.8 2.96 24 1.00 35.5 128 328 2.94 7.7 26 0.97 34.5 124 318 7.5 2.87 26 0.93 31.8 128 328 7.7 2.94 22 0.94 35.0 126 324 2.92 7.6 23 0.90 34.0 123 315 7.4 2.85 24 0.86 31.3 63 141 349 8.0 3.06 23 0.91 37.2 139 346 3.03 8.0 24 0.87 36.1 135 335 7.7 2.96 25 0.84 33.3 139 346 8.0 3.03 19 0.76 37.4 138 342 3.01 7.9 20 0.73 36.3 134 332 7.7 2.94 21 0.70 33.5 67 150 364 8.3 3.15 20 0.74 39.7 148 361 3.13 8.2 21 0.71 38.5 144 350 8.0 3.05 21 0.68 35.6 148 361 8.2 3.13 16 0.57 40.0 147 357 3.10 8.2 16 0.55 38.8 143 346 8.0 3.03 16 0.53 35.8 71 127 350 8.1 3.05 23 1.00 34.0 126 347 3.02 8.0 25 1.00 33.0 122 336 7.8 2.95 27 1.00 30.5 126 347 8.0 3.02 23 1.00 33.4 125 343 3.00 8.0 25 0.99 32.4 121 333 7.7 2.93 25 0.95 29.9 59 135 377 8.3 3.11 24 1.00 34.6 134 373 3.09 8.2 26 1.00 33.6 130 362 8.0 3.01 26 0.96 31.0 134 373 8.2 3.09 23 0.97 34.1 133 369 3.06 8.1 23 0.93 33.1 129 358 7.9 2.99 24 0.89 30.6 63 Entering Indoor Wet Bulb Temperature 85 NOTE: Shaded area is ARI Rating Conditions 124 291 7.2 2.80 24 0.99 36.4 123 288 2.77 7.1 26 0.94 35.3 119 279 6.9 2.71 26 0.91 32.6 123 288 7.1 2.77 22 0.92 35.8 122 285 2.75 7.0 23 0.87 34.8 118 277 6.9 2.69 24 0.84 32.1 75 95 71 148 398 8.6 3.21 23 0.94 36.3 146 394 3.19 8.5 24 0.90 35.2 142 382 8.3 3.11 25 0.87 32.5 146 394 8.5 3.19 20 0.79 158 415 8.9 3.31 20 0.77 38.7 156 411 3.29 8.8 21 0.73 37.6 151 399 8.6 3.21 21 0.70 34.7 156 411 8.8 3.29 16 0.59 39.0 154 36.5 407 145 3.26 8.7 16 0.56 37.8 150 395 8.5 3.18 17 0.54 34.9 390 8.4 20 3.16 0.75 35.4 141 378 8.2 3.08 21 0.73 32.7 67 EXPANDED PERFORMANCE DATA High and low press ures are measured at the liquid and suction service valves. * Entering Indoor Dry Bulb Temperature 1350 1200 1050 1350 1200 1050 Airflow 65 MODEL: GSX130363 A* / CA*F3636*6C* 59 63 142 424 8.8 3.24 22 1.00 32.9 141 420 3.21 8.7 24 1.00 31.9 136 407 8.5 3.14 26 1.00 29.5 141 420 8.7 3.21 22 1.00 32.4 139 415 3.19 8.7 23 0.96 31.5 135 403 8.4 3.11 24 0.93 29.1 67 155 448 9.1 3.34 23 0.98 34.5 153 443 3.32 9.0 24 0.93 33.5 149 430 8.8 3.23 24 0.90 30.9 153 443 9.0 3.32 19 0.82 34.6 152 439 3.29 8.9 20 0.78 33.6 147 426 8.7 3.21 20 0.75 31.0 71 165 467 9.4 3.45 20 0.80 36.8 163 462 3.42 9.4 21 0.76 35.7 159 448 9.1 3.34 21 0.73 33.0 163 462 9.4 3.42 15 0.61 37.0 162 458 3.39 9.3 16 0.58 36.0 157 444 9.0 3.31 16 0.56 33.2 59 138 435 9.1 3.28 20 1.00 29.9 137 431 3.25 9.0 22 1.00 29.0 133 418 8.8 3.17 23 1.00 26.8 137 431 9.0 3.25 20 1.00 29.4 135 427 3.23 8.9 22 1.00 28.5 131 414 8.7 3.15 23 1.00 26.3 63 147 468 9.3 3.35 21 1.00 30.5 145 464 3.32 9.2 23 1.00 29.6 141 450 9.0 3.24 24 1.00 27.3 145 464 9.2 3.32 20 1.00 30.0 144 459 3.29 9.2 22 0.97 29.2 140 445 8.9 3.21 22 0.93 26.9 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 133 394 8.6 3.17 22 1.00 32.3 132 390 3.15 8.5 24 1.00 31.3 128 378 8.3 3.07 25 1.00 28.9 132 390 8.5 3.15 22 1.00 31.7 131 386 3.12 8.5 24 1.00 30.8 127 375 8.2 3.05 25 0.99 28.4 105 115 160 495 9.6 3.46 21 0.99 31.9 159 490 3.43 9.5 22 0.94 31.0 154 475 9.3 3.34 23 0.91 28.6 159 490 9.5 3.43 18 0.83 32.1 157 485 3.40 9.5 19 0.79 31.2 152 470 9.2 3.32 19 0.76 28.8 67 COOLING OPERATION 71 171 516 10.0 3.57 19 0.80 34.1 169 511 3.54 9.9 19 0.76 33.1 164 495 9.6 3.45 20 0.74 30.5 169 511 9.9 3.54 14 0.62 34.3 167 506 3.51 9.8 15 0.59 33.3 162 490 9.5 3.42 15 0.57 30.7 COOLING PERFORMANCE DATA GSX130363A* 43 44 75 70 IDB* 22 63 0.84 21 S/T Delta T 0.88 21 S/T Delta T 7.2 230 110 AMPS HI PR LO PR 3.27 0.78 45.8 MBh KW 47.2 109 LO PR 7.2 117 248 7.3 3.33 19 116 245 7.1 228 HI PR 3.30 20 112 AMPS 3.24 0.75 44.5 MBh KW 45.8 105 LO PR 7.1 238 6.9 221 HI PR 3.23 20 0.72 42.3 116 245 7.2 3.30 15 0.64 46.7 114 243 7.2 3.28 16 0.61 45.4 111 235 7.0 3.21 16 0.59 41.9 AMPS 3.17 Delta T KW 41.1 109 LO PR 0.81 228 HI PR S/T 7.1 MBh 3.24 18 Delta T KW 0.77 S/T AMPS 108 45.1 225 HI PR MBh 7.0 LO PR 3.22 18 Delta T KW 0.73 S/T AMPS 104 43.8 219 HI PR MBh 6.9 LO PR 3.15 KW 19 Delta T AMPS 0.71 S/T 59 40.4 MBh 67 127 261 7.5 3.42 15 0.59 51.1 126 259 7.5 3.40 16 0.57 49.6 122 251 7.3 3.32 16 0.55 45.8 126 259 7.5 3.40 12 0.45 51.2 125 256 7.4 3.37 12 0.43 49.7 121 249 7.2 3.30 12 0.41 45.9 136 273 7.8 3.52 11 0.38 54.8 134 270 7.7 3.50 11 0.36 53.2 130 262 7.5 3.42 11 0.35 49.1 - - - - - - - - - - - - - - - - - - - - - 71 59 116 258 7.7 3.49 21 0.91 44.8 115 256 7.6 3.47 22 0.87 43.5 111 248 7.4 3.39 22 0.83 40.1 115 256 7.6 3.47 18 0.80 44.0 114 253 7.5 3.44 19 0.76 42.7 110 245 7.4 3.37 19 0.73 39.5 63 67 135 293 8.1 3.67 16 0.61 49.9 133 290 8.0 3.64 16 0.59 48.4 129 282 7.8 3.56 17 0.56 44.7 133 290 8.0 3.64 12 0.46 50.0 132 287 7.9 3.61 12 0.44 48.5 128 279 7.7 3.53 12 0.42 44.8 143 306 8.3 3.78 11 0.40 53.6 142 303 8.3 3.75 11 0.38 52.0 138 294 8.1 3.66 11 0.36 48.0 - - - - - - - - - - - - - - - - - - - - - 71 59 120 294 8.2 3.69 21 0.93 43.7 119 291 8.2 3.67 22 0.89 42.4 116 282 8.0 3.58 22 0.86 39.2 119 291 8.2 3.67 18 0.82 43.0 118 288 8.1 3.64 19 0.78 41.7 115 279 7.9 3.56 19 0.75 38.5 128 316 8.4 3.77 19 0.83 45.0 127 313 8.4 3.74 20 0.79 43.7 123 303 8.2 3.65 20 0.77 40.3 127 313 8.4 3.74 16 0.68 44.5 126 310 8.3 3.71 16 0.65 43.2 122 300 8.1 3.63 16 0.63 39.9 63 140 334 8.7 3.88 16 0.63 48.7 139 330 8.6 3.85 16 0.60 47.3 134 320 8.4 3.76 17 0.58 43.7 139 330 8.6 3.85 12 0.47 48.8 137 327 8.5 3.82 12 0.45 47.4 133 317 8.3 3.73 13 0.44 43.7 67 149 348 9.0 4.00 11 0.41 52.3 148 345 8.9 3.97 11 0.39 50.8 143 334 8.7 3.88 11 0.37 46.8 - - - - - - - - - - - - - - - - - - - - - 71 127 334 8.8 3.87 21 0.96 42.6 125 331 8.7 3.84 22 0.92 41.4 122 321 8.5 3.75 22 0.88 38.2 125 331 8.7 3.84 18 0.85 41.9 124 328 8.6 3.81 19 0.81 40.7 120 318 8.4 3.72 19 0.78 37.6 59 135 360 8.9 3.95 19 0.86 43.9 133 356 8.9 3.92 20 0.82 42.6 129 346 8.7 3.83 20 0.79 39.3 133 356 8.9 3.92 16 0.71 43.5 132 353 8.8 3.89 16 0.67 42.2 128 342 8.6 3.80 17 0.65 38.9 63 67 147 380 9.2 4.07 16 0.65 47.5 146 376 9.1 4.04 16 0.62 46.1 141 365 8.9 3.94 17 0.60 42.6 146 376 9.1 4.04 12 0.49 47.6 144 372 9.1 4.01 12 0.47 46.2 140 361 8.8 3.91 13 0.45 42.7 Ente r ing Indoor We t Bulb Te m pe rature 95 Outdoor Am bie nt Te m pe rature 85 NOTE: Shaded area is ACCA (TV A ) conditions 123 278 7.8 3.56 19 0.81 46.1 122 275 7.8 3.53 20 0.77 44.8 118 267 7.6 3.46 20 0.75 41.3 122 275 7.8 3.53 16 0.67 45.6 121 272 7.7 3.51 16 0.64 44.3 117 264 7.5 3.43 16 0.61 40.9 75 EXPANDED PERFORMANCE DATA High and low pressures are measured at the liquid and suction service valves. * Entering Indoor Dry Bulb Temperature 1800 1600 1400 1800 1600 1400 Airflow 65 MODEL: GSX130483A* / CA*F4860*6B* 157 396 9.5 4.19 11 0.42 51.0 155 392 9.5 4.16 11 0.40 49.5 150 381 9.2 4.06 12 0.38 45.7 - - - - - - - - - - - - - - - - - - - - - 71 59 63 141 405 9.5 4.10 19 0.89 41.7 140 401 9.4 4.07 20 0.85 40.5 136 389 9.2 3.98 20 0.82 37.4 140 401 9.4 4.07 15 0.73 41.3 138 397 9.3 4.04 16 0.70 40.1 134 385 9.1 3.95 16 0.67 37.0 67 154 427 9.8 4.23 16 0.67 45.1 153 423 9.7 4.20 16 0.64 43.8 148 411 9.4 4.10 16 0.62 40.5 152 423 9.7 4.20 12 0.51 45.2 151 419 9.6 4.16 12 0.48 43.9 146 406 9.4 4.07 12 0.47 40.5 164 446 10.1 4.36 11 0.43 48.5 162 441 10.0 4.33 11 0.41 47.0 158 428 9.8 4.23 11 0.40 43.4 - - - - - - - - - - - - - - - - - - - - - 71 59 137 416 9.8 4.15 19 1.00 37.5 136 412 9.7 4.12 20 0.96 36.4 132 399 9.4 4.02 20 0.92 33.6 136 411 9.7 4.12 17 0.88 36.9 134 407 9.6 4.09 17 0.84 35.8 130 395 9.4 3.99 18 0.81 33.1 63 146 447 10.0 4.24 18 0.90 38.6 145 443 9.9 4.20 18 0.86 37.5 140 430 9.6 4.11 19 0.83 34.6 144 443 9.9 4.20 14 0.74 38.2 143 438 9.8 4.17 15 0.70 37.1 139 425 9.6 4.07 15 0.68 34.3 AMPS=outdoor unit amps (comp.+fan) KW =Total system power 133 376 9.3 4.02 21 1.00 40.5 131 372 9.2 3.99 21 0.95 39.3 127 361 9.0 3.90 22 0.92 36.3 131 372 9.2 3.99 18 0.88 39.8 130 369 9.1 3.96 19 0.84 38.7 126 358 8.9 3.87 19 0.81 35.7 105 115 159 472 10.3 4.37 15 0.68 41.8 158 468 10.2 4.33 15 0.65 40.6 153 454 9.9 4.23 15 0.63 37.5 158 468 10.2 4.33 11 0.51 41.9 156 463 10.1 4.30 11 0.49 40.7 151 449 9.9 4.20 12 0.47 37.5 67 170 493 10.7 4.51 10 0.44 44.9 168 488 10.6 4.47 10 0.42 43.6 163 473 10.3 4.36 11 0.40 40.2 - - - - - - - - - - - - - - - - - - - - - 71 COOLING OPERATION COOLING PERFORMANCE DATA GSX130483A* 85 80 IDB* 1.00 24 S/T Delta T 7.3 235 112 AMPS HI PR LO PR 3.31 47.5 MBh KW 232 111 HI PR LO PR 119 253 7.4 3.38 24 0.97 48.4 118 250 25 3.35 7.4 25 Delta T 0.93 47.0 243 114 7.2 25 3.28 0.89 43.4 118 7.4 250 3.35 22 117 3.29 7.2 0.96 S/T KW AMPS 46.1 MBh 26 3.22 Delta T KW 7.0 0.93 S/T 225 108 42.5 MBh HI PR LO PR 111 LO PR AMPS 7.2 232 23 AMPS HI PR 0.96 S/T Delta T 3.29 0.90 46.7 MBh KW 47.7 110 LO PR 248 230 3.33 7.3 23 HI PR 24 Delta T 0.86 46.3 3.27 7.2 0.92 S/T KW AMPS 45.3 MBh 113 240 223 106 HI PR 3.26 7.1 3.20 7.0 LO PR KW AMPS 24 23 0.83 0.88 S/T Delta T 63 42.7 59 41.8 MBh 67 130 267 7.6 3.47 23 0.88 50.7 129 264 3.45 7.6 24 0.84 49.2 256 125 7.4 24 3.37 0.81 45.4 129 7.6 264 3.45 19 0.73 50.9 127 261 3.42 7.5 20 0.70 49.5 124 254 3.35 7.3 20 0.67 45.6 71 138 278 7.9 3.58 20 0.71 54.1 137 275 3.55 7.8 20 0.68 52.5 267 133 7.6 21 3.47 0.65 48.5 137 7.8 275 3.55 15 0.55 54.4 136 273 3.52 7.8 16 0.52 52.9 132 265 3.45 7.6 16 0.50 48.8 59 118 263 7.8 3.54 24 1.00 46.4 117 261 3.52 7.7 26 1.00 45.0 253 114 7.5 26 3.44 0.96 41.5 117 7.7 261 3.52 23 1.00 45.6 116 258 3.49 7.7 24 0.95 44.2 112 250 3.42 7.5 25 0.92 40.8 63 126 283 8.0 3.61 24 1.00 47.3 125 281 3.59 7.9 25 0.96 45.9 272 121 7.7 26 3.51 0.93 42.4 125 7.9 281 3.59 22 0.93 46.6 123 278 3.56 7.8 23 0.89 45.2 120 269 3.48 7.6 24 0.86 41.7 75 67 137 299 8.2 3.72 23 0.91 49.5 136 296 3.69 8.1 24 0.87 48.1 287 132 7.9 24 3.61 0.84 44.4 136 8.1 296 3.69 19 0.76 49.7 135 293 3.67 8.1 20 0.72 48.3 131 285 3.58 7.9 20 0.70 44.6 71 146 312 8.5 3.83 20 0.74 52.8 145 309 3.80 8.4 21 0.70 51.3 300 140 8.2 21 3.72 0.68 47.3 145 8.4 309 3.80 15 0.57 53.2 143 306 3.78 8.3 16 0.54 51.6 139 297 3.69 8.1 16 0.52 47.7 59 123 300 8.4 3.75 23 1.00 45.3 122 297 3.72 8.3 25 1.00 43.9 288 118 8.1 26 3.64 0.98 40.6 122 8.3 297 3.72 23 1.00 44.5 120 294 3.69 8.2 24 0.97 43.2 117 285 3.61 8.0 25 0.94 39.9 131 322 8.6 3.82 24 1.00 46.1 129 319 3.80 8.5 25 0.98 44.8 310 126 8.3 26 3.71 0.95 41.3 129 8.5 319 3.80 22 0.96 45.5 128 316 3.77 8.4 23 0.91 44.1 124 306 3.68 8.2 24 0.88 40.7 143 340 8.8 3.94 23 0.93 48.3 141 337 3.91 8.8 24 0.89 46.9 327 137 8.5 24 3.82 0.86 43.3 141 8.8 337 3.91 19 0.78 48.6 140 334 3.88 8.7 20 0.74 47.2 136 324 3.79 8.5 20 0.72 43.5 152 355 9.1 4.06 20 0.76 51.6 151 351 4.03 9.0 21 0.72 50.1 341 146 8.8 21 3.94 0.70 46.2 151 9.0 351 4.03 15 0.58 51.9 149 348 4.00 9.0 16 0.56 50.4 145 338 3.91 8.7 16 0.54 46.5 129 341 8.9 3.93 23 1.00 44.2 128 338 3.90 8.8 25 1.00 42.9 328 124 8.6 26 3.81 1.00 39.6 128 8.8 338 3.90 22 1.00 43.4 127 334 3.87 8.8 24 1.00 42.1 123 324 3.78 8.5 25 0.97 38.9 137 367 9.1 4.01 23 1.00 45.0 136 363 3.98 9.0 25 1.00 43.7 353 132 8.8 26 3.89 0.98 40.3 136 9.0 363 3.98 23 1.00 44.3 135 360 3.95 8.9 23 0.94 43.1 131 349 3.86 8.7 24 0.91 39.7 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 85 Outdoor Ambient Temperature 95 150 388 9.4 4.13 23 0.96 47.1 148 384 4.10 9.3 24 0.92 45.8 372 144 9.1 25 4.01 0.88 42.2 148 9.3 384 4.10 19 0.80 47.4 380 147 9.2 20 4.07 0.77 46.0 143 369 3.97 9.0 21 0.74 42.5 67 EXPANDED PERFORMANCE DATA * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 1800 1600 1400 1800 1600 1400 Airflow 65 MODEL: GSX130483A* / CA*F4860*6B* 71 160 404 9.7 4.26 20 0.78 50.3 158 400 4.23 9.6 21 0.74 48.8 388 153 9.4 21 4.13 0.72 45.1 158 9.6 400 4.23 16 0.60 50.6 157 396 4.20 9.5 16 0.57 49.2 152 384 4.10 9.3 16 0.55 45.4 59 63 144 413 9.6 4.17 22 1.00 42.8 143 409 4.14 9.6 24 1.00 41.5 397 138 9.3 25 4.04 1.00 38.3 143 9.6 409 4.14 22 1.00 42.1 141 405 4.10 9.5 23 0.98 40.9 137 393 4.01 9.2 23 0.94 37.8 67 157 436 9.9 4.30 23 1.00 44.8 156 432 4.26 9.8 24 0.95 43.5 419 151 9.6 24 4.16 0.92 40.1 156 9.8 432 4.26 19 0.83 45.0 154 428 4.23 9.8 20 0.80 43.7 149 415 4.13 9.5 20 0.77 40.3 71 167 455 10.3 4.43 20 0.81 47.8 166 450 4.40 10.2 21 0.77 46.4 437 161 9.9 21 4.29 0.74 42.8 166 10.2 450 4.40 15 0.62 48.1 164 446 4.36 10.1 16 0.60 46.7 159 433 4.26 9.8 16 0.57 43.1 59 140 424 9.9 4.22 20 1.00 38.9 139 420 4.18 9.8 22 1.00 37.7 407 134 9.6 23 4.09 1.00 34.8 139 9.8 420 4.18 20 1.00 38.2 137 416 4.15 9.8 21 1.00 37.1 133 403 4.05 9.5 23 1.01 34.2 63 149 456 10.2 4.30 20 1.00 39.6 147 452 4.27 10.1 22 1.00 38.5 438 143 9.8 23 4.17 1.00 35.5 147 10.1 452 4.27 20 1.00 39.0 146 447 4.24 10.0 21 0.99 37.9 142 434 4.14 9.7 22 0.95 35.0 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 135 384 9.4 4.08 21 1.00 42.0 134 380 4.05 9.3 23 1.00 40.7 369 130 9.1 25 3.96 1.00 37.6 134 9.3 380 4.05 21 1.00 41.2 133 376 4.02 9.3 23 1.00 40.0 129 365 3.93 9.0 24 1.01 36.9 105 115 163 482 10.5 4.44 21 1.00 41.5 161 477 4.40 10.4 22 0.96 40.3 463 156 10.1 23 4.30 0.93 37.2 161 10.4 477 4.40 18 0.84 41.7 159 472 4.37 10.3 19 0.80 40.5 155 458 4.26 10.0 19 0.77 37.4 67 COOLING OPERATION 71 173 503 10.8 4.58 18 0.82 44.3 171 498 4.54 10.7 19 0.78 43.0 483 166 10.5 20 4.43 0.75 39.7 171 10.7 498 4.54 14 0.63 44.6 170 493 4.51 10.7 15 0.60 43.3 165 478 4.40 10.4 15 0.58 39.9 COOLING PERFORMANCE DATA GSX130483A* 45 46 75 70 IDB* 228 109 41.1 0.81 22 HI PR LO PR MBh S/T Delta T 63 21 S/T Delta T 21 S/T Delta T 3.9 230 110 AMPS HI PR LO PR 3.26 0.78 0.88 MBh KW 47.2 109 45.8 LO PR 3.9 117 248 4.0 3.33 19 116 245 3.9 228 HI PR 3.30 20 112 AMPS 3.24 0.75 0.84 MBh KW 45.8 105 44.5 LO PR 3.8 238 3.8 221 HI PR 3.23 20 0.72 42.3 116 245 3.9 3.30 15 0.64 46.7 114 243 3.9 3.28 16 0.61 45.4 111 235 3.8 3.21 16 0.59 41.9 AMPS 3.17 3.9 KW 3.24 18 Delta T KW 0.77 S/T AMPS 108 45.1 225 HI PR MBh 3.8 LO PR 3.22 18 Delta T KW 0.73 S/T AMPS 104 43.8 219 HI PR MBh 3.7 LO PR 3.15 KW 19 Delta T AMPS 0.71 S/T 59 40.4 MBh 67 273 136 127 4.2 3.52 11 0.38 54.8 134 270 4.2 3.50 11 0.36 53.2 130 262 4.1 3.42 11 0.35 49.1 - - - - - - - - - - - - - - - - - - - - - 71 261 4.1 3.42 15 0.59 51.1 126 259 4.0 3.40 16 0.57 49.6 122 251 3.9 3.32 16 0.55 45.8 126 259 4.0 3.40 12 0.45 51.2 125 256 4.0 3.37 12 0.43 49.7 121 249 3.9 3.30 12 0.41 45.9 59 116 258 4.2 3.49 21 0.91 44.8 115 256 4.1 3.47 22 0.87 43.5 111 248 4.0 3.39 22 0.83 40.1 115 256 4.1 3.47 18 0.80 44.0 114 253 4.1 3.44 19 0.76 42.7 110 245 4.0 3.36 19 0.73 39.5 63 67 135 293 4.4 3.66 16 0.61 49.9 133 290 4.3 3.64 16 0.59 48.4 129 282 4.2 3.56 17 0.56 44.7 133 290 4.3 3.64 12 0.46 50.0 132 287 4.3 3.61 12 0.44 48.5 128 279 4.2 3.53 12 0.42 44.8 143 306 4.5 3.77 11 0.40 53.6 142 303 4.5 3.75 11 0.38 52.0 138 294 4.4 3.66 11 0.36 48.0 - - - - - - - - - - - - - - - - - - - - - 71 59 120 294 4.5 3.69 21 0.93 43.7 119 291 4.4 3.67 22 0.89 42.4 116 282 4.3 3.58 22 0.86 39.2 119 291 4.4 3.66 18 0.82 43.0 118 288 4.4 3.64 19 0.78 41.7 115 279 4.3 3.56 19 0.75 38.5 128 316 4.6 3.77 19 0.83 45.0 127 313 4.5 3.74 20 0.79 43.7 123 303 4.4 3.65 20 0.77 40.3 127 313 4.5 3.74 16 0.68 44.5 126 310 4.5 3.71 16 0.65 43.2 122 300 4.4 3.63 16 0.63 39.9 63 140 334 4.7 3.88 16 0.63 48.7 139 330 4.7 3.85 16 0.60 47.3 134 320 4.6 3.76 17 0.58 43.7 139 330 4.7 3.85 12 0.47 48.8 137 327 4.6 3.82 12 0.45 47.4 133 317 4.5 3.73 13 0.44 43.7 67 149 348 4.9 4.00 11 0.41 52.3 148 345 4.8 3.97 11 0.39 50.8 143 334 4.7 3.88 11 0.37 46.8 - - - - - - - - - - - - - - - - - - - - - 71 127 334 4.8 3.87 21 0.96 42.6 125 331 4.7 3.84 22 0.92 41.4 122 321 4.6 3.75 22 0.88 38.2 125 331 4.7 3.84 18 0.85 41.9 124 328 4.7 3.81 19 0.81 40.7 120 318 4.6 3.72 19 0.78 37.6 59 135 360 4.9 3.95 19 0.86 43.9 133 356 4.8 3.92 20 0.82 42.6 129 346 4.7 3.83 20 0.79 39.3 133 356 4.8 3.92 16 0.71 43.5 132 353 4.8 3.89 16 0.67 42.2 128 342 4.7 3.80 17 0.65 38.9 63 67 147 380 5.0 4.07 16 0.65 47.5 146 376 5.0 4.04 16 0.62 46.1 141 365 4.8 3.94 17 0.60 42.6 146 376 5.0 4.04 12 0.49 47.6 144 372 4.9 4.01 12 0.47 46.2 140 361 4.8 3.91 13 0.45 42.7 Ente ring Indoor We t Bulb Te m pe rature 95 Outdoor Am bie nt Te m pe rature 85 NOTE: Shaded area is A CCA (TV A) conditions 123 278 4.2 3.56 19 0.81 46.1 122 275 4.2 3.53 20 0.77 44.8 118 267 4.1 3.46 20 0.75 41.3 122 275 4.2 3.53 16 0.67 45.6 121 272 4.2 3.51 16 0.64 44.3 117 264 4.1 3.43 16 0.61 40.9 75 EXPANDED PERFORMANCE DATA High and low pressures are measured at the liquid and suction service valves. * Entering Indoor Dry Bulb Temperature 1800 1600 1400 1800 1600 1400 Airflow 65 MODEL: GSX130484 A* / CA*F4860*6B* 157 396 5.2 4.19 11 0.42 51.0 155 392 5.1 4.16 11 0.40 49.5 150 381 5.0 4.06 12 0.38 45.7 - - - - - - - - - - - - - - - - - - - - - 71 59 63 141 405 5.1 4.10 19 0.89 41.7 140 401 5.1 4.07 20 0.85 40.5 136 389 5.0 3.98 20 0.82 37.4 140 401 5.1 4.07 15 0.73 41.3 138 397 5.1 4.04 16 0.70 40.1 134 385 4.9 3.95 16 0.67 37.0 67 154 427 5.3 4.23 16 0.67 45.1 153 423 5.3 4.20 16 0.64 43.8 148 411 5.1 4.10 16 0.62 40.5 152 423 5.3 4.20 12 0.51 45.2 151 419 5.2 4.16 12 0.48 43.9 146 406 5.1 4.07 12 0.47 40.5 164 446 5.5 4.36 11 0.43 48.5 162 441 5.4 4.33 11 0.41 47.0 158 428 5.3 4.23 11 0.40 43.4 - - - - - - - - - - - - - - - - - - - - - 71 59 137 416 5.3 4.15 19 1.00 37.5 136 412 5.3 4.12 20 0.96 36.4 132 399 5.1 4.02 20 0.92 33.6 136 411 5.3 4.12 17 0.88 36.9 134 407 5.2 4.09 17 0.84 35.8 130 395 5.1 3.99 18 0.81 33.1 63 146 447 5.4 4.24 18 0.90 38.6 145 443 5.4 4.20 18 0.86 37.5 140 430 5.2 4.11 19 0.83 34.6 144 443 5.4 4.20 14 0.74 38.2 143 438 5.3 4.17 15 0.70 37.1 139 425 5.2 4.07 15 0.68 34.3 AMPS=outdoor unit amps (comp.+fan) KW =Total system power 133 376 5.0 4.02 21 1.00 40.5 131 372 5.0 3.99 21 0.95 39.3 127 361 4.9 3.90 22 0.92 36.3 131 372 5.0 3.99 18 0.88 39.8 130 369 4.9 3.96 19 0.84 38.7 126 358 4.8 3.87 19 0.81 35.7 105 115 159 472 5.6 4.37 15 0.68 41.8 158 468 5.5 4.33 15 0.65 40.6 153 454 5.4 4.23 15 0.63 37.5 158 468 5.5 4.33 11 0.51 41.9 156 463 5.5 4.30 11 0.49 40.7 151 449 5.4 4.20 12 0.47 37.5 67 170 493 5.8 4.51 10 0.44 44.9 168 488 5.7 4.47 10 0.42 43.6 163 473 5.6 4.36 11 0.40 40.2 - - - - - - - - - - - - - - - - - - - - - 71 COOLING OPERATION COOLING PERFORMANCE DATA GSX130484A* 85 80 IDB* 46.3 0.86 45.3 0.92 24 MBh S/T Delta T 240 24 3.9 235 112 AMPS HI PR LO PR 3.31 0.97 1.00 S/T Delta T KW 48.4 47.5 MBh 119 253 4.0 3.38 24 118 232 111 HI PR LO PR 250 25 3.35 4.0 25 Delta T 0.93 47.0 243 114 3.9 25 3.28 0.89 43.4 118 4.0 250 3.35 22 117 3.29 3.9 0.96 S/T KW AMPS 46.1 MBh 26 3.22 Delta T KW 3.8 0.93 S/T 225 108 42.5 MBh HI PR LO PR 111 LO PR AMPS 3.9 232 23 AMPS HI PR 0.96 S/T Delta T 3.29 0.90 46.7 MBh KW 47.7 110 LO PR 248 230 HI PR 3.33 4.0 3.26 3.9 KW AMPS 23 113 223 106 HI PR 3.25 3.9 3.19 3.8 LO PR KW AMPS 24 23 0.83 0.88 S/T Delta T 63 42.7 59 41.8 MBh 67 130 267 4.1 3.47 23 0.88 50.7 129 264 3.45 4.1 24 0.84 49.2 256 125 4.0 24 3.37 0.81 45.4 129 4.1 264 3.45 19 0.73 50.9 127 261 3.42 4.1 20 0.70 49.5 124 254 3.35 4.0 20 0.67 45.6 71 138 278 4.3 3.57 20 0.71 54.1 137 275 3.55 4.2 20 0.68 52.5 267 133 4.1 21 3.47 0.65 48.5 137 4.2 275 3.55 15 0.55 54.4 136 273 3.52 4.2 16 0.52 52.9 132 265 3.44 4.1 16 0.50 48.8 59 118 263 4.2 3.54 24 1.00 46.4 117 261 3.52 4.2 26 1.00 45.0 253 114 4.1 26 3.44 0.96 41.5 117 4.2 261 3.52 23 1.00 45.6 116 258 3.49 4.2 24 0.95 44.2 112 250 3.41 4.1 25 0.92 40.8 63 126 283 4.3 3.61 24 1.00 47.3 125 281 3.59 4.3 25 0.96 45.9 272 121 4.2 26 3.51 0.93 42.4 125 4.3 281 3.59 22 0.93 46.6 123 278 3.56 4.2 23 0.89 45.2 120 269 3.48 4.1 24 0.86 41.7 75 67 137 299 4.4 3.72 23 0.91 49.5 136 296 3.69 4.4 24 0.87 48.1 287 132 4.3 24 3.61 0.84 44.4 136 4.4 296 3.69 19 0.76 49.7 135 293 3.67 4.4 20 0.72 48.3 131 285 3.58 4.3 20 0.70 44.6 71 146 312 4.6 3.83 20 0.74 52.8 145 309 3.80 4.6 21 0.70 51.3 300 140 4.4 21 3.72 0.68 47.3 145 4.6 309 3.80 15 0.57 53.2 143 306 3.78 4.5 16 0.54 51.6 139 297 3.69 4.4 16 0.52 47.7 59 123 300 4.6 3.75 23 1.00 45.3 122 297 3.72 4.5 25 1.00 43.9 288 118 4.4 26 3.64 0.98 40.6 122 4.5 297 3.72 23 1.00 44.5 120 294 3.69 4.5 24 0.97 43.2 117 285 3.61 4.4 25 0.94 39.9 131 322 4.7 3.82 24 1.00 46.1 129 319 3.80 4.6 25 0.98 44.8 310 126 4.5 26 3.71 0.95 41.3 129 4.6 319 3.80 22 0.96 45.5 128 316 3.77 4.6 23 0.91 44.1 124 306 3.68 4.5 24 0.88 40.7 355 152 143 5.0 4.06 20 0.76 51.6 151 351 4.03 4.9 21 0.72 50.1 341 146 4.8 21 3.94 0.70 46.2 151 4.9 351 4.03 15 0.58 51.9 149 348 4.00 4.9 16 0.56 50.4 145 338 3.91 4.8 16 0.54 46.5 340 4.8 3.94 23 0.93 48.3 141 337 3.91 4.8 24 0.89 46.9 327 137 4.6 24 3.82 0.86 43.3 141 4.8 337 3.91 19 0.78 48.6 140 334 3.88 4.7 20 0.74 47.2 136 324 3.79 4.6 20 0.72 43.5 129 341 4.8 3.93 23 1.00 44.2 128 338 3.90 4.8 25 1.00 42.9 328 124 4.7 26 3.81 1.00 39.6 128 4.8 338 3.90 22 1.00 43.4 127 334 3.87 4.8 24 1.00 42.1 123 324 3.78 4.6 25 0.97 38.9 137 367 4.9 4.01 23 1.00 45.0 136 363 3.98 4.9 25 1.00 43.7 353 132 4.8 26 3.89 0.98 40.3 136 4.9 363 3.98 23 1.00 44.3 135 360 3.95 4.9 23 0.94 43.1 131 349 3.86 4.7 24 0.91 39.7 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 85 Outdoor Ambient Temperature 95 150 388 5.1 4.13 23 0.96 47.1 148 384 4.10 5.1 24 0.92 45.8 372 144 4.9 25 4.00 0.88 42.2 148 5.1 384 4.10 19 0.80 47.4 380 147 5.0 20 4.07 0.77 46.0 143 369 3.97 4.9 21 0.74 42.5 67 EXPANDED PERFORMANCE DATA * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 1800 1600 1400 1800 1600 1400 Airflow 65 MODEL: GSX130484 A* / CA*F4860*6B* 71 160 404 5.3 4.26 20 0.78 50.3 158 400 4.23 5.2 21 0.74 48.8 388 153 5.1 21 4.13 0.72 45.1 158 5.2 400 4.23 16 0.60 50.6 157 396 4.20 5.2 16 0.57 49.2 152 384 4.10 5.1 16 0.55 45.4 59 63 144 413 5.2 4.17 22 1.00 42.8 143 409 4.14 5.2 24 1.00 41.5 397 138 5.1 25 4.04 1.00 38.3 143 5.2 409 4.14 22 1.00 42.1 141 405 4.10 5.1 23 0.98 40.9 137 393 4.01 5.0 23 0.94 37.8 67 157 436 5.4 4.30 23 1.00 44.8 156 432 4.26 5.3 24 0.95 43.5 419 151 5.2 24 4.16 0.92 40.1 156 5.3 432 4.26 19 0.83 45.0 154 428 4.23 5.3 20 0.80 43.7 149 415 4.13 5.2 20 0.77 40.3 71 167 455 5.6 4.43 20 0.81 47.8 166 450 4.40 5.5 21 0.77 46.4 437 161 5.4 21 4.29 0.74 42.8 166 5.5 450 4.40 15 0.62 48.1 164 446 4.36 5.5 16 0.60 46.7 159 433 4.26 5.3 16 0.57 43.1 59 140 424 5.4 4.22 20 1.00 38.9 139 420 4.18 5.4 22 1.00 37.7 407 134 5.2 23 4.09 1.00 34.8 139 5.4 420 4.18 20 1.00 38.2 137 416 4.15 5.3 21 1.00 37.1 133 403 4.05 5.2 23 1.01 34.2 63 149 456 5.5 4.30 20 1.00 39.6 147 452 4.27 5.5 22 1.00 38.5 438 143 5.3 23 4.17 1.00 35.5 147 5.5 452 4.27 20 1.00 39.0 146 447 4.24 5.4 21 0.99 37.9 142 434 4.14 5.3 22 0.95 35.0 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 135 384 5.1 4.08 21 1.00 42.0 134 380 4.05 5.1 23 1.00 40.7 369 130 4.9 25 3.96 1.00 37.6 134 5.1 380 4.05 21 1.00 41.2 133 376 4.02 5.0 23 1.00 40.0 129 365 3.93 4.9 24 1.01 36.9 105 115 163 482 5.7 4.44 21 1.00 41.5 161 477 4.40 5.6 22 0.96 40.3 463 156 5.5 23 4.30 0.93 37.2 161 5.6 477 4.40 18 0.84 41.7 159 472 4.37 5.6 19 0.80 40.5 155 458 4.27 5.5 19 0.77 37.4 67 COOLING OPERATION 71 173 503 5.9 4.58 18 0.82 44.3 171 498 4.54 5.8 19 0.78 43.0 483 166 5.7 20 4.43 0.75 39.7 171 5.8 498 4.54 14 0.63 44.6 170 493 4.51 5.8 15 0.60 43.3 165 478 4.40 5.6 15 0.58 39.9 COOLING PERFORMANCE DATA GSX130484A* 47 48 75 70 IDB* 107 50.9 0.76 24 LO PR MBh S/T Delta T 63 0.79 23 S/T Delta T 0.83 22 S/T Delta T 9.5 242 108 AMPS HI PR LO PR 4.17 0.74 56.8 MBh KW 58.5 107 LO PR 9.6 115 260 9.7 4.25 20 114 257 9.4 239 HI PR 4.22 21 111 AMPS 4.15 0.71 55.1 MBh KW 56.8 104 LO PR 9.4 250 9.2 232 HI PR 4.13 22 0.68 52.4 114 257 9.6 4.22 16 0.61 57.9 113 255 9.5 4.19 17 0.58 56.2 109 247 9.3 4.10 18 0.56 51.9 AMPS 4.06 239 HI PR KW 9.4 AMPS 19 Delta T 4.14 0.73 S/T KW 106 55.9 MBh 237 HI PR LO PR 9.3 AMPS 20 Delta T 4.12 0.69 S/T KW 103 54.2 MBh 230 HI PR LO PR 9.1 AMPS 21 4.03 Delta T KW 0.67 S/T 59 50.1 MBh 67 126 274 10.0 4.37 16 0.56 63.3 124 272 9.9 4.34 17 0.53 61.5 121 264 9.7 4.25 18 0.51 56.7 124 272 9.9 4.34 12 0.42 63.4 123 269 9.8 4.31 13 0.40 61.6 120 261 9.6 4.22 13 0.39 56.8 134 286 10.4 4.50 11 0.36 67.9 133 283 10.3 4.46 12 0.34 66.0 129 275 10.0 4.37 12 0.33 60.9 - - - - - - - - - - - - - - - - - - - - - 71 59 114 271 10.2 4.46 22 0.86 55.5 113 268 10.1 4.43 23 0.82 53.9 110 260 9.9 4.33 24 0.79 49.7 113 268 10.1 4.43 19 0.75 54.6 112 266 10.0 4.39 20 0.72 53.0 109 258 9.8 4.30 21 0.69 48.9 63 67 133 308 10.8 4.67 16 0.58 61.8 131 305 10.7 4.64 17 0.55 60.0 128 296 10.4 4.54 18 0.53 55.4 131 305 10.7 4.64 12 0.44 62.0 130 302 10.6 4.61 13 0.42 60.1 126 293 10.3 4.50 14 0.40 55.5 141 321 11.2 4.81 11 0.37 66.4 140 318 11.1 4.77 12 0.36 64.4 136 309 10.8 4.67 13 0.34 59.5 - - - - - - - - - - - - - - - - - - - - - 71 59 119 308 11.1 4.71 22 0.88 54.2 118 305 11.0 4.67 23 0.84 52.6 114 296 10.7 4.57 24 0.81 48.5 118 305 11.0 4.67 19 0.77 53.3 116 302 10.9 4.64 20 0.74 51.7 113 293 10.6 4.54 21 0.71 47.7 126 332 11.3 4.80 20 0.79 55.8 125 328 11.2 4.76 21 0.75 54.1 121 319 10.9 4.66 22 0.72 50.0 125 328 11.2 4.76 16 0.65 55.2 124 325 11.1 4.73 17 0.62 53.6 120 315 10.8 4.62 18 0.59 49.5 63 138 350 11.7 4.94 16 0.59 60.4 137 347 11.6 4.90 17 0.57 58.6 133 336 11.3 4.79 18 0.55 54.1 137 347 11.6 4.90 12 0.45 60.5 135 343 11.5 4.87 13 0.43 58.7 131 333 11.2 4.76 14 0.41 54.2 67 147 365 12.1 5.09 11 0.38 64.8 146 362 12.0 5.05 12 0.36 62.9 141 351 11.7 4.94 13 0.35 58.1 - - - - - - - - - - - - - - - - - - - - - 71 125 351 11.8 4.93 22 0.91 52.8 124 348 11.7 4.89 23 0.86 51.3 120 337 11.4 4.78 24 0.83 47.3 124 348 11.7 4.89 19 0.80 52.0 122 344 11.6 4.86 20 0.76 50.4 119 334 11.3 4.75 21 0.73 46.6 59 133 378 12.1 5.03 20 0.81 54.4 131 374 12.0 4.99 21 0.77 52.8 128 363 11.7 4.88 22 0.75 48.8 131 374 12.0 4.99 16 0.67 53.9 130 370 11.9 4.95 17 0.64 52.3 126 359 11.6 4.84 18 0.61 48.3 63 67 145 399 12.5 5.18 17 0.61 58.9 144 395 12.4 5.14 18 0.59 57.2 139 383 12.0 5.02 18 0.56 52.8 144 395 12.4 5.14 13 0.46 59.0 142 391 12.3 5.10 13 0.44 57.3 138 379 11.9 4.98 14 0.42 52.9 Ente ring Indoor We t Bulb Te m pe rature 95 Outdoor Am bie nt Te m pe rature 85 NOTE: Shaded area is ACCA (TVA ) conditions 122 292 10.5 4.54 20 0.77 57.1 120 289 10.4 4.51 21 0.73 55.5 117 280 10.1 4.41 22 0.70 51.2 120 289 10.4 4.51 16 0.63 56.5 119 286 10.3 4.48 17 0.60 54.9 116 277 10.0 4.38 18 0.58 50.7 75 EXPANDED PERFORMANCE DATA High and low pressures are measured at the liquid and suction service valves. * Entering Indoor Dry Bulb Temperature 2000 1750 1500 2000 1750 1500 Airflow 65 MODEL: GSX130603 A* / CA*F4961*6A* 154 416 12.9 5.33 11 0.39 63.2 153 412 12.8 5.29 12 0.38 61.4 148 400 12.5 5.17 13 0.36 56.6 - - - - - - - - - - - - - - - - - - - - - 71 59 63 139 425 12.9 5.22 20 0.84 51.7 138 421 12.7 5.18 21 0.80 50.2 134 408 12.4 5.06 22 0.77 46.3 138 421 12.7 5.18 16 0.69 51.2 136 417 12.6 5.14 17 0.66 49.7 132 404 12.3 5.02 18 0.64 45.8 67 152 449 13.3 5.38 16 0.64 55.9 150 444 13.2 5.33 17 0.61 54.3 146 431 12.8 5.21 18 0.59 50.1 150 444 13.2 5.33 12 0.48 56.1 149 440 13.0 5.29 13 0.46 54.4 144 427 12.7 5.17 14 0.44 50.2 162 468 13.8 5.54 11 0.41 60.0 160 463 13.6 5.50 12 0.39 58.3 155 450 13.3 5.37 12 0.38 53.8 - - - - - - - - - - - - - - - - - - - - - 71 59 135 436 13.3 5.28 20 0.95 46.5 134 432 13.2 5.24 21 0.91 45.1 130 419 12.8 5.12 22 0.87 41.7 134 432 13.2 5.24 18 0.83 45.7 133 428 13.0 5.20 19 0.80 44.4 129 415 12.7 5.08 19 0.77 41.0 63 144 470 13.6 5.39 19 0.85 47.9 143 465 13.5 5.34 20 0.81 46.5 138 451 13.1 5.22 21 0.78 42.9 143 465 13.5 5.34 15 0.70 47.4 141 460 13.4 5.30 16 0.66 46.0 137 446 13.0 5.18 17 0.64 42.5 AMPS=outdoor unit amps (comp.+fan) KW =Total system power 131 395 12.6 5.12 22 0.94 50.2 130 391 12.4 5.08 23 0.90 48.7 126 379 12.1 4.96 24 0.87 45.0 130 391 12.4 5.08 19 0.83 49.4 128 387 12.3 5.04 20 0.79 47.9 124 375 12.0 4.93 21 0.76 44.2 105 115 157 496 14.0 5.55 15 0.64 51.8 156 491 13.9 5.51 16 0.61 50.3 151 476 13.5 5.38 17 0.59 46.4 156 491 13.9 5.51 12 0.48 51.9 154 486 13.8 5.46 12 0.46 50.4 149 471 13.4 5.34 13 0.44 46.5 67 167 517 14.6 5.72 11 0.41 55.6 166 512 14.4 5.68 11 0.39 54.0 161 497 14.0 5.54 12 0.38 49.8 - - - - - - - - - - - - - - - - - - - - - 71 COOLING OPERATION COOLING PERFORMANCE DATA GSX130603A* 85 80 IDB* 252 234 105 56.1 0.86 25 HI PR LO PR MBh S/T Delta T 0.95 26 S/T Delta T 9.6 246 110 AMPS HI PR LO PR 4.23 58.8 MBh KW 263 109 117 265 9.9 4.31 25 0.92 60.0 116 244 HI PR LO PR 27 4.28 9.8 27 Delta T 0.87 58.2 255 113 9.5 28 4.19 0.84 53.7 116 9.8 263 4.28 23 115 4.20 9.6 0.91 S/T KW AMPS 57.1 MBh 28 4.12 Delta T KW 9.3 0.87 S/T 237 106 52.7 MBh HI PR LO PR 109 LO PR AMPS 9.6 244 24 AMPS HI PR 0.91 S/T Delta T 4.20 0.85 57.8 MBh KW 59.1 108 LO PR 260 242 HI PR 4.25 9.7 4.17 9.5 KW AMPS 24 0.81 57.4 112 4.16 9.4 4.09 9.2 KW AMPS 26 25 0.78 0.83 S/T Delta T 63 52.9 59 51.8 MBh 67 128 280 10.2 4.43 24 0.83 62.8 127 277 4.40 10.1 25 0.79 61.0 269 123 9.8 26 4.31 0.76 56.3 127 10.1 277 4.40 20 0.69 63.1 126 275 4.37 10.0 21 0.66 61.3 122 266 4.28 9.7 22 0.64 56.6 71 137 292 10.5 4.56 21 0.67 67.0 135 289 4.53 10.5 22 0.64 65.0 281 131 10.2 23 4.43 0.62 60.0 135 10.5 289 4.53 16 0.52 67.5 134 286 4.50 10.4 17 0.49 65.5 130 278 4.40 10.1 18 0.48 60.5 59 117 277 10.4 4.52 26 0.99 57.5 116 274 4.49 10.3 28 0.94 55.8 266 112 10.0 29 4.39 0.91 51.5 116 10.3 274 4.49 24 0.94 56.5 114 271 4.46 10.2 26 0.90 54.8 111 263 4.36 10.0 27 0.86 50.6 63 124 298 10.6 4.61 26 0.95 58.6 123 295 4.58 10.6 27 0.91 56.9 286 119 10.3 28 4.48 0.87 52.5 123 10.6 295 4.58 23 0.88 57.7 122 292 4.54 10.5 25 0.84 56.0 118 283 4.44 10.2 26 0.81 51.7 75 67 135 314 11.0 4.74 24 0.86 61.3 134 311 4.71 10.9 26 0.82 59.6 302 130 10.6 27 4.60 0.79 55.0 134 10.9 311 4.71 20 0.72 61.6 133 308 4.67 10.8 22 0.68 59.9 129 299 4.57 10.5 22 0.66 55.2 71 144 328 11.4 4.88 21 0.70 65.4 143 324 4.85 11.3 22 0.66 63.5 315 139 11.0 23 4.74 0.64 58.6 143 11.3 324 4.85 16 0.54 65.9 141 321 4.81 11.2 17 0.51 64.0 137 312 4.70 10.9 18 0.49 59.1 59 121 314 11.3 4.78 26 1.00 56.1 120 311 4.74 11.2 28 0.96 54.5 302 116 10.9 29 4.64 0.93 50.3 120 11.2 311 4.74 24 0.96 55.1 119 308 4.71 11.1 26 0.92 53.5 115 299 4.60 10.8 27 0.89 49.4 129 338 11.5 4.87 26 0.97 57.2 128 335 4.84 11.4 27 0.93 55.5 325 124 11.1 28 4.73 0.90 51.2 128 11.4 335 4.84 23 0.90 56.3 126 332 4.80 11.3 25 0.86 54.7 123 322 4.69 11.0 26 0.83 50.5 141 357 11.9 5.01 24 0.88 59.9 139 354 4.98 11.8 26 0.84 58.1 343 135 11.5 27 4.87 0.81 53.7 139 11.8 354 4.98 20 0.74 60.2 138 350 4.94 11.7 22 0.70 58.4 134 340 4.83 11.4 22 0.68 53.9 150 373 12.4 5.17 21 0.71 63.9 148 369 5.13 12.2 22 0.68 62.0 358 144 11.9 23 5.01 0.66 57.2 148 12.2 369 5.13 16 0.55 64.3 147 365 5.09 12.1 17 0.52 62.5 143 354 4.97 11.8 18 0.51 57.6 127 358 12.0 5.00 25 1.00 54.7 126 355 4.97 11.9 28 0.99 53.1 344 122 11.6 29 4.85 0.96 49.0 126 11.9 355 4.97 25 1.00 53.8 125 351 4.93 11.8 26 0.95 52.2 121 341 4.82 11.5 27 0.91 48.2 135 385 12.3 5.10 26 1.00 55.8 134 382 5.06 12.2 27 0.96 54.2 370 130 11.9 28 4.95 0.93 50.0 134 12.2 382 5.06 24 0.93 55.0 133 378 5.03 12.1 25 0.89 53.4 129 367 4.91 11.8 26 0.86 49.2 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 85 Outdoor Ambient Temperature 95 148 407 12.7 5.25 24 0.91 58.4 146 403 5.22 12.6 26 0.87 56.7 391 142 12.3 27 5.10 0.83 52.3 146 12.6 403 5.22 20 0.76 58.7 399 145 12.5 22 5.18 0.72 57.0 141 387 5.06 12.2 23 0.70 52.6 67 EXPANDED PERFORMANCE DATA * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 2000 1750 1500 2000 1750 1500 Airflow 65 MODEL: GSX130603 A* / CA*F4961*6A* 71 158 425 13.2 5.42 21 0.74 62.3 156 420 5.37 13.1 22 0.70 60.5 408 151 12.7 23 5.25 0.68 55.8 156 13.1 420 5.37 16 0.57 62.8 154 416 5.33 13.0 17 0.54 60.9 150 404 5.21 12.6 18 0.52 56.2 59 63 142 434 13.1 5.30 24 1.00 53.0 141 429 5.26 13.0 27 1.00 51.4 416 136 12.6 28 5.14 0.96 47.5 141 13.0 429 5.26 23 0.97 52.2 139 425 5.22 12.9 25 0.92 50.7 135 412 5.10 12.5 26 0.89 46.8 67 155 458 13.5 5.46 24 0.94 55.5 153 453 5.42 13.4 25 0.90 53.9 440 149 13.0 26 5.29 0.87 49.7 153 13.4 453 5.42 20 0.79 55.8 152 449 5.38 13.3 21 0.75 54.2 147 435 5.25 12.9 22 0.72 50.0 71 165 478 14.0 5.63 21 0.76 59.2 163 473 5.58 13.9 22 0.73 57.5 459 159 13.5 23 5.45 0.70 53.1 163 13.9 473 5.58 16 0.59 59.6 162 468 5.54 13.8 17 0.56 57.9 157 454 5.41 13.4 18 0.54 53.4 59 138 445 13.5 5.36 22 1.00 48.2 137 441 5.32 13.4 25 1.00 46.7 428 133 13.0 26 5.20 1.00 43.1 137 13.4 441 5.32 22 1.00 47.3 135 436 5.28 13.3 24 0.99 45.9 131 423 5.16 12.9 25 0.96 42.4 63 147 479 13.9 5.47 23 1.00 49.1 145 474 5.43 13.7 25 1.00 47.7 460 141 13.4 26 5.30 0.97 44.0 145 13.7 474 5.43 22 1.00 48.4 144 470 5.39 13.6 23 0.93 46.9 140 456 5.26 13.2 24 0.90 43.3 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 133 403 12.8 5.19 24 1.00 52.0 132 399 5.15 12.7 27 1.00 50.5 387 128 12.3 28 5.04 1.00 46.6 132 12.7 399 5.15 23 1.00 51.1 131 395 5.12 12.6 26 0.98 49.6 127 383 5.00 12.2 27 0.95 45.8 105 115 160 506 14.3 5.64 22 0.95 51.4 159 501 5.59 14.2 24 0.91 49.9 486 154 13.8 25 5.46 0.87 46.1 159 14.2 501 5.59 19 0.79 51.7 157 496 5.55 14.1 20 0.76 50.2 152 481 5.42 13.7 21 0.73 46.3 67 COOLING OPERATION 71 171 528 14.8 5.81 19 0.77 54.8 169 522 5.77 14.7 21 0.74 53.2 507 164 14.3 21 5.63 0.71 49.1 169 14.7 522 5.77 15 0.59 55.2 167 517 5.72 14.6 16 0.57 53.6 162 502 5.59 14.2 17 0.55 49.5 COOLING PERFORMANCE DATA GSX130603A* 49 50 75 70 IDB* 21 20 Delta T 19 Delta T 50.9 0.76 24 LO PR MBh S/T Delta T 63 23 S/T Delta T 22 S/T Delta T 5.3 260 107 A MPS HI PR LO PR 4.17 0.74 0.83 MBh KW 58.5 106 56.8 LO PR 5.4 114 280 5.4 4.25 20 113 277 5.3 258 HI PR 4.21 21 110 A MPS 4.14 0.71 0.79 MBh KW 56.8 103 55.1 LO PR 5.3 269 5.2 250 HI PR 4.12 22 0.68 52.4 113 277 5.4 4.21 16 0.61 57.9 112 275 5.3 4.18 17 0.58 56.2 109 266 5.2 4.09 18 0.56 51.9 A MPS 4.05 106 HI PR KW 5.3 258 A MPS 4.13 0.73 S/T KW 105 55.9 MBh HI PR LO PR 5.2 255 A MPS 4.10 0.69 S/T KW 102 54.2 MBh HI PR LO PR 5.1 247 A MPS 4.02 Delta T KW 0.67 S/T 59 50.1 MBh 67 309 133 125 5.8 4.50 11 0.36 67.9 132 305 5.7 4.46 12 0.34 66.0 128 296 5.6 4.36 12 0.33 60.9 - - - - - - - - - - - - - - - - - - - - - 71 296 5.6 4.37 16 0.56 63.3 124 293 5.5 4.34 17 0.53 61.5 120 284 5.4 4.24 18 0.51 56.7 124 293 5.5 4.34 12 0.42 63.4 122 290 5.5 4.30 13 0.40 61.6 119 281 5.4 4.21 13 0.39 56.8 59 114 292 5.7 4.46 22 0.86 55.5 112 289 5.6 4.42 23 0.82 53.9 109 281 5.5 4.33 24 0.79 49.7 112 289 5.6 4.42 19 0.75 54.6 111 286 5.6 4.39 20 0.72 53.0 108 278 5.5 4.29 21 0.69 48.9 63 67 132 332 6.0 4.68 16 0.58 61.8 131 329 5.9 4.65 17 0.55 60.0 127 319 5.8 4.54 18 0.53 55.4 131 329 5.9 4.64 12 0.44 62.0 129 325 5.9 4.61 13 0.42 60.1 125 316 5.7 4.51 14 0.40 55.5 140 346 6.2 4.82 11 0.37 66.4 139 343 6.1 4.79 12 0.36 64.4 135 332 6.0 4.68 13 0.34 59.5 - - - - - - - - - - - - - - - - - - - - - 71 59 118 332 6.1 4.72 22 0.88 54.2 117 329 6.1 4.68 23 0.84 52.6 113 319 5.9 4.57 24 0.81 48.5 117 329 6.1 4.68 19 0.77 53.3 116 326 6.0 4.64 20 0.74 51.7 112 316 5.9 4.54 21 0.71 47.7 126 357 6.2 4.81 20 0.79 55.8 124 354 6.2 4.78 21 0.75 54.1 121 343 6.0 4.67 22 0.72 50.0 124 354 6.2 4.77 16 0.65 55.2 123 350 6.1 4.74 17 0.62 53.6 119 340 6.0 4.63 18 0.59 49.5 63 137 378 6.4 4.96 16 0.59 60.4 136 374 6.4 4.92 17 0.57 58.6 132 363 6.2 4.81 18 0.55 54.1 136 374 6.4 4.92 12 0.45 60.5 134 370 6.3 4.88 13 0.43 58.7 130 359 6.2 4.77 14 0.41 54.2 67 146 394 6.6 5.11 11 0.38 64.8 145 390 6.6 5.07 12 0.36 62.9 140 378 6.4 4.95 13 0.35 58.1 - - - - - - - - - - - - - - - - - - - - - 71 124 378 6.5 4.94 22 0.91 52.8 123 375 6.4 4.91 23 0.86 51.3 119 363 6.3 4.79 24 0.83 47.3 123 375 6.4 4.91 19 0.80 52.0 122 371 6.4 4.87 20 0.76 50.4 118 360 6.2 4.76 21 0.73 46.6 59 132 407 6.6 5.05 20 0.81 54.4 131 403 6.6 5.01 21 0.77 52.8 127 391 6.4 4.89 22 0.75 48.8 131 403 6.6 5.01 16 0.67 53.9 129 399 6.5 4.97 17 0.64 52.3 125 387 6.3 4.85 18 0.61 48.3 63 67 144 430 6.8 5.20 17 0.61 58.9 143 426 6.7 5.16 18 0.59 57.2 138 413 6.6 5.04 18 0.56 52.8 143 426 6.7 5.16 13 0.46 59.0 141 421 6.7 5.12 13 0.44 57.3 137 409 6.5 5.00 14 0.42 52.9 Ente ring Indoor We t Bulb Te m pe rature 95 Outdoor Am bie nt Te m pe rature 85 NOTE: Shaded area is A CCA (TVA ) conditions 121 314 5.8 4.55 20 0.77 57.1 120 311 5.8 4.51 21 0.73 55.5 116 302 5.6 4.41 22 0.70 51.2 120 311 5.8 4.51 16 0.63 56.5 118 308 5.7 4.48 17 0.60 54.9 115 299 5.6 4.38 18 0.58 50.7 75 EXPANDED PERFORM ANCE DATA High and low pressures are measured at the liquid and suction service valves. * Entering Indoor Dry Bulb Temperature 2000 1750 1500 2000 1750 1500 Airflow 65 MODEL: GSX130604 A* / CA*F4961*6A* 153 448 7.0 5.36 11 0.39 63.2 152 444 7.0 5.32 12 0.38 61.4 147 431 6.8 5.19 13 0.36 56.6 - - - - - - - - - - - - - - - - - - - - - 71 59 63 138 458 7.0 5.24 20 0.84 51.7 137 454 6.9 5.20 21 0.80 50.2 133 440 6.8 5.08 22 0.77 46.3 137 453 6.9 5.20 16 0.69 51.2 135 449 6.9 5.16 17 0.66 49.7 131 435 6.7 5.04 18 0.64 45.8 67 151 484 7.2 5.41 16 0.64 55.9 149 479 7.1 5.36 17 0.61 54.3 145 465 7.0 5.24 18 0.59 50.1 149 479 7.1 5.36 12 0.48 56.1 148 474 7.1 5.32 13 0.46 54.4 143 460 6.9 5.20 14 0.44 50.2 161 505 7.4 5.58 11 0.41 60.0 159 500 7.4 5.53 12 0.39 58.3 154 485 7.2 5.40 12 0.38 53.8 - - - - - - - - - - - - - - - - - - - - - 71 59 134 470 7.2 5.31 20 0.95 46.5 133 466 7.1 5.26 21 0.91 45.1 129 452 7.0 5.14 22 0.87 41.7 133 466 7.1 5.26 18 0.83 45.7 132 461 7.1 5.22 19 0.80 44.4 128 447 6.9 5.10 19 0.77 41.0 63 143 506 7.3 5.42 19 0.85 47.9 142 501 7.3 5.37 20 0.81 46.5 137 486 7.1 5.25 21 0.78 42.9 142 501 7.3 5.37 15 0.70 47.4 140 496 7.2 5.33 16 0.66 46.0 136 481 7.0 5.21 17 0.64 42.5 AMPS=outdoor unit amps (comp.+fan) KW =Total system power 130 426 6.8 5.14 22 0.94 50.2 129 421 6.8 5.10 23 0.90 48.7 125 409 6.6 4.98 24 0.87 45.0 129 421 6.8 5.10 19 0.83 49.4 127 417 6.7 5.06 20 0.79 47.9 124 405 6.6 4.94 21 0.76 44.2 105 115 156 534 7.6 5.58 15 0.64 51.8 155 529 7.5 5.54 16 0.61 50.3 150 513 7.3 5.41 17 0.59 46.4 155 529 7.5 5.54 12 0.48 51.9 153 524 7.4 5.50 12 0.46 50.4 148 508 7.3 5.37 13 0.44 46.5 67 166 557 7.8 5.76 11 0.41 55.6 165 552 7.8 5.72 11 0.39 54.0 160 535 7.6 5.58 12 0.38 49.8 - - - - - - - - - - - - - - - - - - - - - 71 COOLING OPERATION COOLING PERFORMANCE DATA GSX130604A* 85 80 IDB* 272 253 104 56.1 0.86 25 HI PR LO PR MBh S/T Delta T 0.95 26 S/T Delta T 5.4 266 110 AMPS HI PR LO PR 4.23 58.8 MBh KW 109 117 286 5.5 4.31 25 0.92 60.0 116 283 263 HI PR LO PR 27 4.28 5.5 27 Delta T 0.87 58.2 274 112 5.3 28 4.18 0.84 53.7 116 5.5 283 4.28 23 114 4.20 5.4 0.91 S/T KW AMPS 57.1 MBh 28 4.10 Delta T KW 5.2 0.87 S/T 255 105 52.7 MBh HI PR LO PR 109 LO PR AMPS 5.4 263 24 AMPS HI PR 0.91 S/T Delta T 4.20 0.85 57.8 MBh KW 59.1 107 LO PR 280 260 HI PR 4.25 5.4 4.17 5.3 KW AMPS 24 0.81 57.4 111 4.15 5.3 4.07 5.2 KW AMPS 26 25 0.78 0.83 S/T Delta T 63 52.9 59 51.8 MBh 67 127 302 5.7 4.43 24 0.83 62.8 126 299 4.40 5.6 25 0.79 61.0 290 122 5.5 26 4.30 0.76 56.3 126 5.6 299 4.40 20 0.69 63.1 125 296 4.37 5.6 21 0.66 61.3 121 287 4.27 5.4 22 0.64 56.6 71 136 315 5.8 4.56 21 0.67 67.0 134 312 4.53 5.8 22 0.64 65.0 302 130 5.7 23 4.43 0.62 60.0 134 5.8 312 4.53 16 0.52 67.5 133 309 4.50 5.8 17 0.49 65.5 129 299 4.40 5.6 18 0.48 60.5 59 116 298 5.8 4.52 26 0.99 57.5 115 295 4.49 5.7 28 0.94 55.8 286 111 5.6 29 4.39 0.91 51.5 115 5.7 295 4.49 24 0.94 56.5 114 292 4.46 5.7 26 0.90 54.8 110 283 4.36 5.5 27 0.86 50.6 63 123 321 5.9 4.61 26 0.95 58.6 122 318 4.58 5.8 27 0.91 56.9 308 118 5.7 28 4.48 0.87 52.5 122 5.8 318 4.58 23 0.88 57.7 121 314 4.55 5.8 25 0.84 56.0 117 305 4.44 5.7 26 0.81 51.7 75 67 135 339 6.1 4.75 24 0.86 61.3 133 335 4.72 6.0 26 0.82 59.6 325 129 5.9 27 4.61 0.79 55.0 133 6.0 335 4.72 20 0.72 61.6 132 332 4.68 6.0 22 0.68 59.9 128 322 4.57 5.8 22 0.66 55.2 71 143 353 6.3 4.90 21 0.70 65.4 142 350 4.86 6.2 22 0.66 63.5 339 138 6.1 23 4.75 0.64 58.6 142 6.2 350 4.86 16 0.54 65.9 140 346 4.82 6.2 17 0.51 64.0 136 336 4.71 6.0 18 0.49 59.1 59 120 339 6.2 4.79 26 1.00 56.1 119 336 4.75 6.2 28 0.96 54.5 325 116 6.0 29 4.64 0.93 50.3 119 6.2 336 4.75 24 0.96 55.1 118 332 4.72 6.1 26 0.92 53.5 114 322 4.61 6.0 27 0.89 49.4 128 365 6.3 4.89 26 0.97 57.2 127 361 4.85 6.3 27 0.93 55.5 350 123 6.1 28 4.74 0.90 51.2 127 6.3 361 4.85 23 0.90 56.3 126 358 4.81 6.2 25 0.86 54.7 122 347 4.70 6.1 26 0.83 50.5 402 149 140 6.7 5.19 21 0.71 63.9 147 398 5.15 6.7 22 0.68 62.0 386 143 6.5 23 5.03 0.66 57.2 147 6.7 398 5.15 16 0.55 64.3 146 394 5.11 6.6 17 0.52 62.5 142 382 4.99 6.5 18 0.51 57.6 385 6.5 5.03 24 0.88 59.9 138 381 4.99 6.5 26 0.84 58.1 370 134 6.3 27 4.88 0.81 53.7 138 6.5 381 4.99 20 0.74 60.2 137 378 4.96 6.4 22 0.70 58.4 133 366 4.84 6.3 22 0.68 53.9 126 386 6.6 5.02 25 1.00 54.7 125 382 4.98 6.5 28 0.99 53.1 371 121 6.4 29 4.87 0.96 49.0 125 6.5 382 4.98 25 1.00 53.8 124 378 4.94 6.5 26 0.95 52.2 120 367 4.83 6.3 27 0.91 48.2 135 415 6.7 5.12 26 1.00 55.8 133 411 5.08 6.7 27 0.96 54.2 399 129 6.5 28 4.97 0.93 50.0 133 6.7 411 5.08 24 0.93 55.0 132 407 5.05 6.6 25 0.89 53.4 128 395 4.93 6.4 26 0.86 49.2 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 85 Outdoor Ambient Temperature 95 147 439 6.9 5.28 24 0.91 58.4 145 434 5.24 6.9 26 0.87 56.7 421 141 6.7 27 5.12 0.83 52.3 145 6.9 434 5.24 20 0.76 58.7 430 144 6.8 22 5.20 0.72 57.0 140 417 5.08 6.6 23 0.70 52.6 67 EXPANDED PERFORMANCE DATA * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 2000 1750 1500 2000 1750 1500 Airflow 65 MODEL: GSX130604 A* / CA*F4961*6A* 71 156 458 7.1 5.45 21 0.74 62.3 155 453 5.40 7.1 22 0.70 60.5 439 150 6.9 23 5.28 0.68 55.8 155 7.1 453 5.40 16 0.57 62.8 153 448 5.36 7.0 17 0.54 60.9 149 435 5.24 6.9 18 0.52 56.2 59 63 141 467 7.1 5.33 24 1.00 53.0 140 463 5.29 7.0 27 1.00 51.4 449 135 6.9 28 5.16 0.96 47.5 140 7.0 463 5.29 23 0.97 52.2 138 458 5.24 7.0 25 0.92 50.7 134 444 5.12 6.8 26 0.89 46.8 67 154 493 7.3 5.49 24 0.94 55.5 152 489 5.45 7.2 25 0.90 53.9 474 148 7.1 26 5.32 0.87 49.7 152 7.2 489 5.45 20 0.79 55.8 151 484 5.41 7.2 21 0.75 54.2 146 469 5.28 7.0 22 0.72 50.0 71 164 515 7.6 5.67 21 0.76 59.2 162 510 5.62 7.5 22 0.73 57.5 494 157 7.3 23 5.49 0.70 53.1 162 7.5 510 5.62 16 0.59 59.6 161 505 5.58 7.4 17 0.56 57.9 156 489 5.44 7.2 18 0.54 53.4 59 137 480 7.3 5.39 22 1.00 48.2 136 475 5.35 7.3 25 1.00 46.7 461 132 7.1 26 5.22 1.00 43.1 136 7.3 475 5.35 22 1.00 47.3 134 470 5.31 7.2 24 0.99 45.9 130 456 5.18 7.0 25 0.96 42.4 63 146 516 7.5 5.50 23 1.00 49.1 144 511 5.46 7.4 25 1.00 47.7 496 140 7.2 26 5.33 0.97 44.0 144 7.4 511 5.46 22 1.00 48.4 143 506 5.42 7.3 23 0.93 46.9 139 491 5.29 7.2 24 0.90 43.3 AMPS=outdoor unit amps (comp.+fan) KW=Total system power 133 434 6.9 5.22 24 1.00 52.0 131 430 5.18 6.9 27 1.00 50.5 417 127 6.7 28 5.06 1.00 46.6 131 6.9 430 5.18 23 1.00 51.1 130 426 5.14 6.8 26 0.98 49.6 126 413 5.02 6.7 27 0.95 45.8 105 115 159 545 7.7 5.67 22 0.95 51.4 158 540 5.63 7.6 24 0.91 49.9 524 153 7.4 25 5.50 0.87 46.1 158 7.6 540 5.63 19 0.79 51.7 156 534 5.59 7.6 20 0.76 50.2 151 518 5.45 7.4 21 0.73 46.3 67 COOLING OPERATION 71 170 569 8.0 5.86 19 0.77 54.8 168 563 5.81 7.9 21 0.74 53.2 546 163 7.7 21 5.67 0.71 49.1 168 7.9 563 5.81 15 0.59 55.2 166 557 5.76 7.8 16 0.57 53.6 161 541 5.62 7.6 17 0.55 49.5 COOLING PERFORMANCE DATA GSX130604A* 51 PERFORMANCE DATA PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and high side pressures and power will not change. 2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will occur in low and high side pressures and power. A properly operating unit should be within plus or minus 2 degrees of the subcooling value shown in the installation instructions. A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown. A properly operating unit should be within plus or minus 10 PSIG of the HI PR shown. A properly operating unit should be within plus or minus 5 PSIG of the LO PR shown. A properly operating unit should be within plus or minus 3 Amps of the typical value shown. NOTE: Pressures are measures at the liquid and suction service valve ports. 52 L2 L1 1 SR IO CM AUX MAIN ALTERNATE DOUBLE POLE CONTACTOR T2 T1 YL 2 5 BK BL BK BR PU BK YL RD CONTROL BOX C R AUX MAIN COMP S HPS BL/PK BL/PK BL T1 L1 C L2 T2 BK BK BK RCCF YL YL BL HERM YL F SA (IF USED) NOTE 2 RD BR C RD RD RD YL EQUIPMENT GROUND USE COPPER CONDUCTORS ONLY RD PU RD RD SC C Y NOTE 1 L1 C T1 C CM IO IO MA CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. Y IN X AU SR 2 SC C (IF USED) SA RCCF C F H 1 T2 C 0140R00116 USE N.E.C. CLASS 2 WIRE NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR THERMOSTAT. 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. HPS C X S AU COMP MA IN R 5 OUTDOOR POWER SUPPLY SEE RATING PLATE COMPONENT CODE C --------------- CONTACTOR CM ------------ OUTDOOR FAN MOTOR COMP -------- COMPRESSOR IO -------------- INTERNAL OVERLOAD LVJB ---------- LOW VOLTAGE JUNCTION BOX RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN SA ------------- START ASSIST SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) HPS ----------- HIGH PRESSURE SWITCH FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE COLOR CODE BK --------------- BLACK BL --------------- BLUE BR --------------- BROWN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL --------------- YELLOW BL/PK ----------- BLUE/PINK STRIPE BL BL/PK ALTERNATE DOUBLE POLE CONTACTOR ONLY LVJB L2 WIRING DIAGRAMS GSX130[18-60]1A* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 53 L2 L1 1 IO CM AUX MAIN ALTERNATE DOUBLE POLE CONTACTOR T2 T1 YL 2 SR BL BK BR PU BK YL RD C R AUX MAIN COMP S YL BL L1 C L2 YL BL HERM YL YL F YL RCCF SA (IF USED) NOTE 2 RD BR C RD RD RD EQUIPMENT GROUND USE COPPER CONDUCTORS ONLY RD PU RD T2 T1 RD BK BK BK SC Y C NOTE 1 L1 C T1 CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. COMPONENT CODE C --------------- CONTACTOR CM ------------ OUTDOOR FAN MOTOR COMP -------- COMPRESSOR IO -------------- INTERNAL OVERLOAD LVJB ---------- LOW VOLTAGE JUNCTION BOX RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN SA ------------- START ASSIST SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) S R ------------- START RELAY FOR COMPRESSOR (OPTIONAL) FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE COLOR CODE BK --------------- BLACK BL --------------- BLUE BR --------------- BROWN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL --------------- YELLOW YL BL LVJB ALTERNATE DOUBLE POLE CONTACTOR ONLY 54 5 BK CONTROL BOX C Y SR 2 C F SC C (IF USED) SA RCCF H 1 T2 C L2 0140R00015P USE N.E.C. CLASS 2 WIRE NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR THERMOSTAT. 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. C R X S AU COMP M AI N X AU M A CM IN IO IO 5 OUTDOOR POWER SUPPLY SEE RATING PLATE WIRING DIAGRAMS GSX130[18-60]1B*/GSX130181C* VSX130[18-60]1A* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. WIRING DIAGRAMS VSX130181B* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. OT--------------OUTDOOR THERMOSTAT 0140R00165-A Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 55 56 IO CM AUX MAIN BK BR PU YL YL T1 BK BL CONTROLBOX Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. COMP T2 L2 L1 T3 RD L3 T3 T2 T1 C YL RD BK BK PU RD RD BR EQUIPMENTGROUND USECOPPER CONDUCTORSONLY FC C LVJB NOTE1 L1 C T1 CONTROLSSHOWNWITHTHERMOSTATIN'OFF'POSITION. COMPONENTCODE C---------------CONTACTOR CM------------OUTDOORFANMOTOR COMP--------COMPRESSOR FC-------------FANCAPACITOR IO--------------INTERNALOVERLOAD LVJB ----------LOWVOLTAGE JUNCTIONBOX FIELDWIRING HIGHVOLTAGE LOWVOLTAGE WIRINGCODE FACTORYWIRING HIGHVOLTAGE LOWVOLTAGE OPTIONALHIGHVOLTAGE COLORCODE BK---------------BLACK BL---------------BLUE BR---------------BROWN OR---------------ORANGE PU---------------PURPLE RD---------------RED WH--------------WHITE YL---------------YELLOW Y YL BL LVJB C IO Y T1 CM IO M X C C FC L2 T3 C 0140R00160REV.B USE N.E.C.CLASS2WIRE NOTES: 1)TOINDOORUNITLOWVOLTAGE TERMINALBLOCK &INDOOR THERMOSTAT. C AI N AU T3 COMP T2 T2 OUTDOORPOWERSUPPLY SEERATINGPLATE L3 WIRING DIAGRAMS GSX130[36-60][3,4]A* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.