Download GE WV-2HG User's Manual
Transcript
W E L L S M A N U FA C T U R I N G R R STD.4 MODEL W V- 2 H G G R I D D L E , 2 C A ST I R O N E L E M E N TS R LISTED E146882 DIMENSIONS: INCH (MM) MINIMUM CLEARANCE REQUIRED FROM UNIT TO THE NEAREST SURFACE BACK NA NA SIDE SEE REQUIRED SPACERS BOTTOM 6 (152) ITEM NO. WV-FG, WV-2HG, WV-2HSG VENTLESS GRIDDLE/FRYER/COOKTOPS TOP 8 (203) The ventless hood gives you the flexibility to “set up shop” just about anywhere from malls, stadiums and high-rise buildings to basement kitchens and kiosks. COOKING SURFACE ILLUSTRATION AIR EXHAUST Griddle (All Models) GRIDDLE: 17 1/4 X 18 1/4 9" DIA SOLID CAST IRON ELEMENTS 30 3/8 (771) 48 11/16 (1237) 35 3/8 REQUIRED 6" CLEARANCE SPACERS & SIDE SHIELDS 17 3/8 (441) OPENING • Griddle surface (17 1/4”W x 18 1/4”D) has enclosed tubular elements that provide even heat distribution. • Griddle is controlled by a positive-off thermostat adjustable from 100ºF to 400ºF. • Griddle features include a full-width front grease trough, an extra-large removable front grease drawer and a stainless steel splashguard. (898) Fryer 79 1/8 (2010) CONTROL PANEL 21 36 (533) (914) 27 1/16 22 3/4 (687) (578) 6 FT. POWER SUPPLY CORD AND PLUG 42 3/8 (1076) W V - 2 H G E L E C T R I C A L S P E C I F I C AT I O N S : AMPS PER LINE 3 PHASE L1 L2 L3 WV-FGRW MODELS VOLTS WATTS POWER SUPPLY CORD WV-2HG 208 8000 16 32 23 NEMA 15-60P WV-2HG 240 9900 18 35 24 NEMA 15-60P WV-2HGRW* 208 8675 19 32 26 NEMA 15-60P WV-2HGRW* 240 10800 21 35 27 NEMA 15-60P *RW Models include optional RW-26 built-in standard double drawer warmers. NOTE: Specifications are subject to change without notice. SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors. Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area. WELLS MANUFACTURING COMPANY 2 ERIK CIRCLE, PO BOX 280, VERDI, NV 89439 U.S.A. USA PHONE: (775) 345-0444 • FAX: (775) 345-0569 FOR ORDERS ONLY: (888) 356-5362 • FAX: (800) 356-5142 www.wells-mfg.com © 2002 WELLS MANUFACTURING • PRINTED IN THE U.S.A. 05/02 • REV(-) • PART NO. 304421-2 (shown with optional drawer warmer) Ventless Hood (All Models) • Ventless Hood System exceeds EPA Standard 202 for the release of particulate matter. • Interlock System will not allow heating elements to be energized if any of the filters are not in place. • Airflow Sensing System continually monitors airflow through the filtration system, optimizing performance and grease removal. ® • Ansul R-102 Fire Suppression System is built into the ventless hood to provide ultimate protection. • Shatter-resistent interior light for improved visibility. (WV-FG, WV-FGRW) • Two half-size, rear hanging, interchangeable fry baskets are provided. • Efficient heating element is flat, heavy-duty stainless steel. • Fryer on/off switch is located in recessed front control panel. • The positive-off thermostat controls the element allowing for adjustable and more consistent temperatures. • The fryer has a manual reset safety thermostat that will shut off the heating element if an over-temperature condition is reached. • Model WV-FGRW includes a Wells RW-26 built-in standard double drawer warmer that replaces lower storage cabinet. Cooktop (WV-2HG, WV-2HSG, WV-2HGRW, WV-2HSGRW) • Model WV-2HG has two solid cast iron 9" french plate elements that are independently regulated by an infinite control with a positive-off position. • Model WV-2HSG has two spiral 8" elements that are independently regulated by an infinite control with a positive-off position. • Models WV-2HGRW and WV-2HSGRW include a Wells RW-26 built-in standard double drawer warmer that replaces lower storage cabinet. WELLS VENTLESS GRIDDLE/FRYER/COOKTOPS LISTED E146882 W E L L S M A N U FA C T U R I N G W E L L S M A N U FA C T U R I N G W E L L S M A N U FA C T U R I N G R R LISTED E146882 MODEL W V- F G G R I D D LE, F RYE R R STD.4 LISTED E146882 DIMENSIONS: INCH (MM) MINIMUM CLEARANCE REQUIRED FROM UNIT TO THE NEAREST SURFACE BACK NA NA SIDE SEE REQUIRED SPACERS BOTTOM 6 (152) R R LISTED E146882 MODEL W V- 2 H S G G R I D D L E , 2 S P I R A L E L E M E N TS R STD.4 LISTED E146882 DIMENSIONS: INCH (MM) MINIMUM CLEARANCE REQUIRED FROM UNIT TO THE NEAREST SURFACE BACK NA NA TOP 8 (203) AIR EXHAUST GRIDDLE: 17 1/4 X 18 1/4 FRYER 30 3/8 (771) 17 3/8 (441) OPENING TOP 8 (203) GRIDDLE: 17 1/4 X 18 1/4 8 INCH SPIRAL ELEMENTS 30 3/8 (771) 48 11/16 (1237) 47 15/16 1217 35 3/8 (898) REQUIRED 6" CLEARANCE SPACERS & SIDE SHIELDS BOTTOM 6 (152) COOKING SURFACE ILLUSTRATION COOKING SURFACE ILLUSTRATION AIR EXHAUST SIDE SEE REQUIRED SPACERS 35 3/8 (898) REQUIRED 6" CLEARANCE SPACERS & SIDE SHIELDS 17 3/8 (441) OPENING 79 1/8 79 1/8 (2010) (2010) 21 (533) CONTROL PANEL CONTROL PANEL 36 (914) 27 1/16 (687) 22 3/4 (578) 42 3/8 (1076) 27 1/16 VOLTS WATTS WV-FG 208 10750 30 43 WV-FG 240 11650 26 WV-FGRW* 208 11425 WV-FGRW* 240 12550 577 6 FT. POWER SUPPLY CORD AND PLUG 42 3/8 1076 W V - 2 H S G E L E C T R I C A L S P E C I F I C AT I O N S : AMPS PER LINE 3 PHASE L1 L2 L3 MODELS 22 3/4 688 6 FT. POWER SUPPLY CORD AND PLUG W V - F G E L E C T R I C A L S P E C I F I C AT I O N S : 36 (914) AMPS PER LINE 3 PHASE L1 L2 L3 POWER SUPPLY CORD MODELS VOLTS WATTS 24 NEMA 15-60P WV-2HSG 208 8900 21 35 24 NEMA 15-60P 40 24 NEMA 15-60P WV-2HSG 240 11100 23 38 24 NEMA 15-60P 32 43 26 NEMA 15-60P WV-2HSGRW* 208 9575 23 35 26 NEMA 15-60P 28 40 27 NEMA 15-60P WV-2HSGRW* 240 12000 26 38 27 NEMA 15-60P POWER SUPPLY CORD *RW Models include optional RW-26 built-in standard double drawer warmers. NOTE: Specifications are subject to change without notice. SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors. Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area. *RW Models include optional RW-26 built-in standard double drawer warmers. NOTE: Specifications are subject to change without notice. SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors. Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area. 05/02 • REV(-) • PART NO. 304421-1 05/02 • REV(-) • PART NO. 304421-3 W E L L S M A N U FA C T U R I N G W E L L S M A N U FA C T U R I N G R R LISTED E146882 MODEL W V- F G G R I D D LE, F RYE R R STD.4 LISTED E146882 DIMENSIONS: INCH (MM) MINIMUM CLEARANCE REQUIRED FROM UNIT TO THE NEAREST SURFACE BACK NA NA SIDE SEE REQUIRED SPACERS BOTTOM 6 (152) R R LISTED E146882 MODEL W V- 2 H S G G R I D D L E , 2 S P I R A L E L E M E N TS R STD.4 LISTED E146882 DIMENSIONS: INCH (MM) MINIMUM CLEARANCE REQUIRED FROM UNIT TO THE NEAREST SURFACE BACK NA NA TOP 8 (203) AIR EXHAUST GRIDDLE: 17 1/4 X 18 1/4 FRYER 30 3/8 (771) 17 3/8 (441) OPENING TOP 8 (203) GRIDDLE: 17 1/4 X 18 1/4 8 INCH SPIRAL ELEMENTS 30 3/8 (771) 48 11/16 (1237) 47 15/16 1217 35 3/8 (898) REQUIRED 6" CLEARANCE SPACERS & SIDE SHIELDS BOTTOM 6 (152) COOKING SURFACE ILLUSTRATION COOKING SURFACE ILLUSTRATION AIR EXHAUST SIDE SEE REQUIRED SPACERS 35 3/8 (898) REQUIRED 6" CLEARANCE SPACERS & SIDE SHIELDS 17 3/8 (441) OPENING 79 1/8 79 1/8 (2010) (2010) 21 (533) CONTROL PANEL CONTROL PANEL 36 (914) 27 1/16 (687) 22 3/4 (578) 42 3/8 (1076) 27 1/16 VOLTS WATTS WV-FG 208 10750 30 43 WV-FG 240 11650 26 WV-FGRW* 208 11425 WV-FGRW* 240 12550 577 6 FT. POWER SUPPLY CORD AND PLUG 42 3/8 1076 W V - 2 H S G E L E C T R I C A L S P E C I F I C AT I O N S : AMPS PER LINE 3 PHASE L1 L2 L3 MODELS 22 3/4 688 6 FT. POWER SUPPLY CORD AND PLUG W V - F G E L E C T R I C A L S P E C I F I C AT I O N S : 36 (914) AMPS PER LINE 3 PHASE L1 L2 L3 POWER SUPPLY CORD MODELS VOLTS WATTS 24 NEMA 15-60P WV-2HSG 208 8900 21 35 24 NEMA 15-60P 40 24 NEMA 15-60P WV-2HSG 240 11100 23 38 24 NEMA 15-60P 32 43 26 NEMA 15-60P WV-2HSGRW* 208 9575 23 35 26 NEMA 15-60P 28 40 27 NEMA 15-60P WV-2HSGRW* 240 12000 26 38 27 NEMA 15-60P POWER SUPPLY CORD *RW Models include optional RW-26 built-in standard double drawer warmers. NOTE: Specifications are subject to change without notice. SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors. Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area. *RW Models include optional RW-26 built-in standard double drawer warmers. NOTE: Specifications are subject to change without notice. SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors. Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area. 05/02 • REV(-) • PART NO. 304421-1 05/02 • REV(-) • PART NO. 304421-3 W E L L S M A N U FA C T U R I N G R R STD.4 MODEL W V- 2 H G G R I D D L E , 2 C A ST I R O N E L E M E N TS R LISTED E146882 DIMENSIONS: INCH (MM) MINIMUM CLEARANCE REQUIRED FROM UNIT TO THE NEAREST SURFACE BACK NA NA SIDE SEE REQUIRED SPACERS BOTTOM 6 (152) ITEM NO. WV-FG, WV-2HG, WV-2HSG VENTLESS GRIDDLE/FRYER/COOKTOPS TOP 8 (203) The ventless hood gives you the flexibility to “set up shop” just about anywhere from malls, stadiums and high-rise buildings to basement kitchens and kiosks. COOKING SURFACE ILLUSTRATION AIR EXHAUST Griddle (All Models) GRIDDLE: 17 1/4 X 18 1/4 9" DIA SOLID CAST IRON ELEMENTS 30 3/8 (771) 48 11/16 (1237) 35 3/8 REQUIRED 6" CLEARANCE SPACERS & SIDE SHIELDS 17 3/8 (441) OPENING • Griddle surface (17 1/4”W x 18 1/4”D) has enclosed tubular elements that provide even heat distribution. • Griddle is controlled by a positive-off thermostat adjustable from 100ºF to 400ºF. • Griddle features include a full-width front grease trough, an extra-large removable front grease drawer and a stainless steel splashguard. (898) Fryer 79 1/8 (2010) CONTROL PANEL 21 36 (533) (914) 27 1/16 22 3/4 (687) (578) 6 FT. POWER SUPPLY CORD AND PLUG 42 3/8 (1076) W V - 2 H G E L E C T R I C A L S P E C I F I C AT I O N S : AMPS PER LINE 3 PHASE L1 L2 L3 WV-FGRW MODELS VOLTS WATTS POWER SUPPLY CORD WV-2HG 208 8000 16 32 23 NEMA 15-60P WV-2HG 240 9900 18 35 24 NEMA 15-60P WV-2HGRW* 208 8675 19 32 26 NEMA 15-60P WV-2HGRW* 240 10800 21 35 27 NEMA 15-60P *RW Models include optional RW-26 built-in standard double drawer warmers. NOTE: Specifications are subject to change without notice. SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors. Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area. WELLS MANUFACTURING COMPANY 2 ERIK CIRCLE, PO BOX 280, VERDI, NV 89439 U.S.A. USA PHONE: (775) 689-5700 • FAX: (775) 689-5972 FOR ORDERS ONLY: (888) 356-5362 • FAX: (800) 356-5142 www.wells-mfg.com © 2002 WELLS MANUFACTURING • PRINTED IN THE U.S.A. 05/02 • REV(-) • PART NO. 304421-2 (shown with optional drawer warmer) Ventless Hood (All Models) • Ventless Hood System exceeds EPA Standard 202 for the release of particulate matter. • Interlock System will not allow heating elements to be energized if any of the filters are not in place. • Airflow Sensing System continually monitors airflow through the filtration system, optimizing performance and grease removal. ® • Ansul R-102 Fire Suppression System is built into the ventless hood to provide ultimate protection. • Shatter-resistent interior light for improved visibility. (WV-FG, WV-FGRW) • Two half-size, rear hanging, interchangeable fry baskets are provided. • Efficient heating element is flat, heavy-duty stainless steel. • Fryer on/off switch is located in recessed front control panel. • The positive-off thermostat controls the element allowing for adjustable and more consistent temperatures. • The fryer has a manual reset safety thermostat that will shut off the heating element if an over-temperature condition is reached. • Model WV-FGRW includes a Wells RW-26 built-in standard double drawer warmer that replaces lower storage cabinet. Cooktop (WV-2HG, WV-2HSG, WV-2HGRW, WV-2HSGRW) • Model WV-2HG has two solid cast iron 9" french plate elements that are independently regulated by an infinite control with a positive-off position. • Model WV-2HSG has two spiral 8" elements that are independently regulated by an infinite control with a positive-off position. • Models WV-2HGRW and WV-2HSGRW include a Wells RW-26 built-in standard double drawer warmer that replaces lower storage cabinet. WELLS VENTLESS GRIDDLE/FRYER/COOKTOPS LISTED E146882 W E L L S M A N U FA C T U R I N G