Download GE WV-2HG User's Manual

Transcript
W E L L S M A N U FA C T U R I N G
R
R
STD.4
MODEL
W V- 2 H G
G R I D D L E , 2 C A ST I R O N E L E M E N TS
R
LISTED
E146882
DIMENSIONS:
INCH
(MM)
MINIMUM CLEARANCE REQUIRED FROM UNIT
TO THE NEAREST SURFACE
BACK
NA
NA
SIDE
SEE REQUIRED
SPACERS
BOTTOM
6
(152)
ITEM NO.
WV-FG, WV-2HG, WV-2HSG
VENTLESS GRIDDLE/FRYER/COOKTOPS
TOP
8
(203)
The ventless hood gives you the flexibility to “set up shop” just
about anywhere from malls, stadiums and high-rise buildings
to basement kitchens and kiosks.
COOKING SURFACE ILLUSTRATION
AIR
EXHAUST
Griddle (All Models)
GRIDDLE: 17 1/4 X 18 1/4
9" DIA SOLID CAST IRON ELEMENTS
30 3/8
(771)
48 11/16
(1237)
35 3/8
REQUIRED
6" CLEARANCE
SPACERS & SIDE
SHIELDS
17 3/8
(441)
OPENING
• Griddle surface (17 1/4”W x 18 1/4”D) has
enclosed tubular elements that provide even
heat distribution.
• Griddle is controlled by a positive-off thermostat
adjustable from 100ºF to 400ºF.
• Griddle features include a full-width front grease
trough, an extra-large removable front grease
drawer and a stainless steel splashguard.
(898)
Fryer
79 1/8
(2010)
CONTROL
PANEL
21
36
(533)
(914)
27 1/16
22 3/4
(687)
(578)
6 FT. POWER
SUPPLY CORD
AND PLUG
42 3/8
(1076)
W V - 2 H G E L E C T R I C A L S P E C I F I C AT I O N S :
AMPS PER LINE 3 PHASE
L1
L2
L3
WV-FGRW
MODELS
VOLTS
WATTS
POWER SUPPLY CORD
WV-2HG
208
8000
16
32
23
NEMA 15-60P
WV-2HG
240
9900
18
35
24
NEMA 15-60P
WV-2HGRW*
208
8675
19
32
26
NEMA 15-60P
WV-2HGRW*
240
10800
21
35
27
NEMA 15-60P
*RW Models include optional RW-26 built-in standard double drawer warmers.
NOTE: Specifications are subject to change without notice.
SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors.
Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of
odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area.
WELLS MANUFACTURING COMPANY
2 ERIK CIRCLE, PO BOX 280, VERDI, NV 89439 U.S.A.
USA PHONE: (775) 345-0444 • FAX: (775) 345-0569
FOR ORDERS ONLY: (888) 356-5362 • FAX: (800) 356-5142
www.wells-mfg.com
© 2002 WELLS MANUFACTURING • PRINTED IN THE U.S.A.
05/02 • REV(-) • PART NO. 304421-2
(shown with optional drawer warmer)
Ventless Hood (All Models)
• Ventless Hood System exceeds EPA Standard
202 for the release of particulate matter.
• Interlock System will not allow heating
elements to be energized if any of the filters
are not in place.
• Airflow Sensing System continually monitors
airflow through the filtration system, optimizing
performance and grease removal.
®
• Ansul R-102 Fire Suppression System
is built into the ventless hood to provide
ultimate protection.
• Shatter-resistent interior light for
improved visibility.
(WV-FG, WV-FGRW)
• Two half-size, rear hanging, interchangeable fry
baskets are provided.
• Efficient heating element is flat, heavy-duty
stainless steel.
• Fryer on/off switch is located in recessed front
control panel.
• The positive-off thermostat controls the
element allowing for adjustable and more
consistent temperatures.
• The fryer has a manual reset safety thermostat
that will shut off the heating element if an
over-temperature condition is reached.
• Model WV-FGRW includes a Wells RW-26 built-in
standard double drawer warmer that replaces lower
storage cabinet.
Cooktop (WV-2HG, WV-2HSG, WV-2HGRW, WV-2HSGRW)
• Model WV-2HG has two solid cast iron 9" french
plate elements that are independently regulated by
an infinite control with a positive-off position.
• Model WV-2HSG has two spiral 8" elements that
are independently regulated by an infinite control
with a positive-off position.
• Models WV-2HGRW and WV-2HSGRW include a
Wells RW-26 built-in standard double drawer
warmer that replaces lower storage cabinet.
WELLS
VENTLESS GRIDDLE/FRYER/COOKTOPS
LISTED
E146882
W E L L S M A N U FA C T U R I N G
W E L L S M A N U FA C T U R I N G
W E L L S M A N U FA C T U R I N G
R
R
LISTED
E146882
MODEL
W V- F G
G R I D D LE, F RYE R
R
STD.4
LISTED
E146882
DIMENSIONS:
INCH
(MM)
MINIMUM CLEARANCE REQUIRED FROM UNIT
TO THE NEAREST SURFACE
BACK
NA
NA
SIDE
SEE REQUIRED
SPACERS
BOTTOM
6
(152)
R
R
LISTED
E146882
MODEL
W V- 2 H S G
G R I D D L E , 2 S P I R A L E L E M E N TS
R
STD.4
LISTED
E146882
DIMENSIONS:
INCH
(MM)
MINIMUM CLEARANCE REQUIRED FROM UNIT
TO THE NEAREST SURFACE
BACK
NA
NA
TOP
8
(203)
AIR
EXHAUST
GRIDDLE: 17 1/4 X 18 1/4
FRYER
30 3/8
(771)
17 3/8
(441)
OPENING
TOP
8
(203)
GRIDDLE: 17 1/4 X 18 1/4
8 INCH SPIRAL ELEMENTS
30 3/8
(771)
48 11/16
(1237)
47 15/16
1217
35 3/8
(898)
REQUIRED
6" CLEARANCE
SPACERS & SIDE
SHIELDS
BOTTOM
6
(152)
COOKING SURFACE ILLUSTRATION
COOKING SURFACE ILLUSTRATION
AIR
EXHAUST
SIDE
SEE REQUIRED
SPACERS
35 3/8
(898)
REQUIRED
6" CLEARANCE
SPACERS & SIDE
SHIELDS
17 3/8
(441)
OPENING
79 1/8
79 1/8
(2010)
(2010)
21
(533)
CONTROL
PANEL
CONTROL
PANEL
36
(914)
27 1/16
(687)
22 3/4
(578)
42 3/8
(1076)
27 1/16
VOLTS
WATTS
WV-FG
208
10750
30
43
WV-FG
240
11650
26
WV-FGRW*
208
11425
WV-FGRW*
240
12550
577
6 FT. POWER
SUPPLY CORD
AND PLUG
42 3/8
1076
W V - 2 H S G E L E C T R I C A L S P E C I F I C AT I O N S :
AMPS PER LINE 3 PHASE
L1
L2
L3
MODELS
22 3/4
688
6 FT. POWER
SUPPLY CORD
AND PLUG
W V - F G E L E C T R I C A L S P E C I F I C AT I O N S :
36
(914)
AMPS PER LINE 3 PHASE
L1
L2
L3
POWER SUPPLY CORD
MODELS
VOLTS
WATTS
24
NEMA 15-60P
WV-2HSG
208
8900
21
35
24
NEMA 15-60P
40
24
NEMA 15-60P
WV-2HSG
240
11100
23
38
24
NEMA 15-60P
32
43
26
NEMA 15-60P
WV-2HSGRW*
208
9575
23
35
26
NEMA 15-60P
28
40
27
NEMA 15-60P
WV-2HSGRW*
240
12000
26
38
27
NEMA 15-60P
POWER SUPPLY CORD
*RW Models include optional RW-26 built-in standard double drawer warmers.
NOTE: Specifications are subject to change without notice.
SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors.
Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of
odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area.
*RW Models include optional RW-26 built-in standard double drawer warmers.
NOTE: Specifications are subject to change without notice.
SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors.
Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of
odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area.
05/02 • REV(-) • PART NO. 304421-1
05/02 • REV(-) • PART NO. 304421-3
W E L L S M A N U FA C T U R I N G
W E L L S M A N U FA C T U R I N G
R
R
LISTED
E146882
MODEL
W V- F G
G R I D D LE, F RYE R
R
STD.4
LISTED
E146882
DIMENSIONS:
INCH
(MM)
MINIMUM CLEARANCE REQUIRED FROM UNIT
TO THE NEAREST SURFACE
BACK
NA
NA
SIDE
SEE REQUIRED
SPACERS
BOTTOM
6
(152)
R
R
LISTED
E146882
MODEL
W V- 2 H S G
G R I D D L E , 2 S P I R A L E L E M E N TS
R
STD.4
LISTED
E146882
DIMENSIONS:
INCH
(MM)
MINIMUM CLEARANCE REQUIRED FROM UNIT
TO THE NEAREST SURFACE
BACK
NA
NA
TOP
8
(203)
AIR
EXHAUST
GRIDDLE: 17 1/4 X 18 1/4
FRYER
30 3/8
(771)
17 3/8
(441)
OPENING
TOP
8
(203)
GRIDDLE: 17 1/4 X 18 1/4
8 INCH SPIRAL ELEMENTS
30 3/8
(771)
48 11/16
(1237)
47 15/16
1217
35 3/8
(898)
REQUIRED
6" CLEARANCE
SPACERS & SIDE
SHIELDS
BOTTOM
6
(152)
COOKING SURFACE ILLUSTRATION
COOKING SURFACE ILLUSTRATION
AIR
EXHAUST
SIDE
SEE REQUIRED
SPACERS
35 3/8
(898)
REQUIRED
6" CLEARANCE
SPACERS & SIDE
SHIELDS
17 3/8
(441)
OPENING
79 1/8
79 1/8
(2010)
(2010)
21
(533)
CONTROL
PANEL
CONTROL
PANEL
36
(914)
27 1/16
(687)
22 3/4
(578)
42 3/8
(1076)
27 1/16
VOLTS
WATTS
WV-FG
208
10750
30
43
WV-FG
240
11650
26
WV-FGRW*
208
11425
WV-FGRW*
240
12550
577
6 FT. POWER
SUPPLY CORD
AND PLUG
42 3/8
1076
W V - 2 H S G E L E C T R I C A L S P E C I F I C AT I O N S :
AMPS PER LINE 3 PHASE
L1
L2
L3
MODELS
22 3/4
688
6 FT. POWER
SUPPLY CORD
AND PLUG
W V - F G E L E C T R I C A L S P E C I F I C AT I O N S :
36
(914)
AMPS PER LINE 3 PHASE
L1
L2
L3
POWER SUPPLY CORD
MODELS
VOLTS
WATTS
24
NEMA 15-60P
WV-2HSG
208
8900
21
35
24
NEMA 15-60P
40
24
NEMA 15-60P
WV-2HSG
240
11100
23
38
24
NEMA 15-60P
32
43
26
NEMA 15-60P
WV-2HSGRW*
208
9575
23
35
26
NEMA 15-60P
28
40
27
NEMA 15-60P
WV-2HSGRW*
240
12000
26
38
27
NEMA 15-60P
POWER SUPPLY CORD
*RW Models include optional RW-26 built-in standard double drawer warmers.
NOTE: Specifications are subject to change without notice.
SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors.
Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of
odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area.
*RW Models include optional RW-26 built-in standard double drawer warmers.
NOTE: Specifications are subject to change without notice.
SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors.
Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of
odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area.
05/02 • REV(-) • PART NO. 304421-1
05/02 • REV(-) • PART NO. 304421-3
W E L L S M A N U FA C T U R I N G
R
R
STD.4
MODEL
W V- 2 H G
G R I D D L E , 2 C A ST I R O N E L E M E N TS
R
LISTED
E146882
DIMENSIONS:
INCH
(MM)
MINIMUM CLEARANCE REQUIRED FROM UNIT
TO THE NEAREST SURFACE
BACK
NA
NA
SIDE
SEE REQUIRED
SPACERS
BOTTOM
6
(152)
ITEM NO.
WV-FG, WV-2HG, WV-2HSG
VENTLESS GRIDDLE/FRYER/COOKTOPS
TOP
8
(203)
The ventless hood gives you the flexibility to “set up shop” just
about anywhere from malls, stadiums and high-rise buildings
to basement kitchens and kiosks.
COOKING SURFACE ILLUSTRATION
AIR
EXHAUST
Griddle (All Models)
GRIDDLE: 17 1/4 X 18 1/4
9" DIA SOLID CAST IRON ELEMENTS
30 3/8
(771)
48 11/16
(1237)
35 3/8
REQUIRED
6" CLEARANCE
SPACERS & SIDE
SHIELDS
17 3/8
(441)
OPENING
• Griddle surface (17 1/4”W x 18 1/4”D) has
enclosed tubular elements that provide even
heat distribution.
• Griddle is controlled by a positive-off thermostat
adjustable from 100ºF to 400ºF.
• Griddle features include a full-width front grease
trough, an extra-large removable front grease
drawer and a stainless steel splashguard.
(898)
Fryer
79 1/8
(2010)
CONTROL
PANEL
21
36
(533)
(914)
27 1/16
22 3/4
(687)
(578)
6 FT. POWER
SUPPLY CORD
AND PLUG
42 3/8
(1076)
W V - 2 H G E L E C T R I C A L S P E C I F I C AT I O N S :
AMPS PER LINE 3 PHASE
L1
L2
L3
WV-FGRW
MODELS
VOLTS
WATTS
POWER SUPPLY CORD
WV-2HG
208
8000
16
32
23
NEMA 15-60P
WV-2HG
240
9900
18
35
24
NEMA 15-60P
WV-2HGRW*
208
8675
19
32
26
NEMA 15-60P
WV-2HGRW*
240
10800
21
35
27
NEMA 15-60P
*RW Models include optional RW-26 built-in standard double drawer warmers.
NOTE: Specifications are subject to change without notice.
SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors.
Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of
odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area.
WELLS MANUFACTURING COMPANY
2 ERIK CIRCLE, PO BOX 280, VERDI, NV 89439 U.S.A.
USA PHONE: (775) 689-5700 • FAX: (775) 689-5972
FOR ORDERS ONLY: (888) 356-5362 • FAX: (800) 356-5142
www.wells-mfg.com
© 2002 WELLS MANUFACTURING • PRINTED IN THE U.S.A.
05/02 • REV(-) • PART NO. 304421-2
(shown with optional drawer warmer)
Ventless Hood (All Models)
• Ventless Hood System exceeds EPA Standard
202 for the release of particulate matter.
• Interlock System will not allow heating
elements to be energized if any of the filters
are not in place.
• Airflow Sensing System continually monitors
airflow through the filtration system, optimizing
performance and grease removal.
®
• Ansul R-102 Fire Suppression System
is built into the ventless hood to provide
ultimate protection.
• Shatter-resistent interior light for
improved visibility.
(WV-FG, WV-FGRW)
• Two half-size, rear hanging, interchangeable fry
baskets are provided.
• Efficient heating element is flat, heavy-duty
stainless steel.
• Fryer on/off switch is located in recessed front
control panel.
• The positive-off thermostat controls the
element allowing for adjustable and more
consistent temperatures.
• The fryer has a manual reset safety thermostat
that will shut off the heating element if an
over-temperature condition is reached.
• Model WV-FGRW includes a Wells RW-26 built-in
standard double drawer warmer that replaces lower
storage cabinet.
Cooktop (WV-2HG, WV-2HSG, WV-2HGRW, WV-2HSGRW)
• Model WV-2HG has two solid cast iron 9" french
plate elements that are independently regulated by
an infinite control with a positive-off position.
• Model WV-2HSG has two spiral 8" elements that
are independently regulated by an infinite control
with a positive-off position.
• Models WV-2HGRW and WV-2HSGRW include a
Wells RW-26 built-in standard double drawer
warmer that replaces lower storage cabinet.
WELLS
VENTLESS GRIDDLE/FRYER/COOKTOPS
LISTED
E146882
W E L L S M A N U FA C T U R I N G