3c Square Pole Architectural Arm Mounting
FIXTURE ARM TO ARM ADAPTER
Torque Top Bolt
to 25 - 32 ft-lbs.
(34-43 N-m)
This luminaire has been configured the same as 3b
and an adapter plate has been included to mount to
a square pole. Hole pattern on square pole shall be in
­accordance with Figure 5.
• Orient adapter block so that oval shaped through hole is closer to top than bottom of adapter.
• With adapter block end oriented properly, mount adapter block to pole with the nut plate and 3/8-16 bolts and washer supplied as shown. Torque 3/8-16 bolts to 25 - 32ft-lbs (34-43 N-m). (See Figure 6)
• Place fixture against adapter block.
• Install 3/8 bolt, lock washer and washer in top as shown and tighten into adapter block.
(See Figure 7)
• Open arm door and Install 3/8 bolt into tapped hole of adapter block. (See Figure 7)
• Torque top and bottom bolts to 25 - 32 ft-lbs (34-43 N-m).
• Inspect installation to ensure fixture is secure.
DRILLING TEMPLATE
SQUARE POLE MOUNTING
.312 in. DIA.
(8 mm DIA.)
5.2500 in.
(133 mm)
(MIN.)
1.8120 in.
(46 mm)
.438 in. DIA.
(11 mm DIA.)
(2 PLACES)
2.1960 in.
(56 mm)
4.3920 in.
(112 mm)
1.250 in. DIA.
(32 mm DIA.)
(HOLE)
Torque Bottom Bolt
to 25 - 32 ft-lbs.
(34-43 N-m)
FIGURE 7
3d Knuckle Slipfitter for 2-3/8 in. (60mm) to 3.0 in.
(76mm) OD Tenon
This luminaire has been configured specifically to provide
0 to 45° vertical aiming in 5° increments and mount on
2-3/8-inch O.D. (73mm) through 3-inch O.D. (76mm) pipe.
•
•
•
•
Place slipfitter on the tenon.
Three set screws are used to clamp the floodlight securely to the pipe. Tighten set screws to 18-22 foot pounds (24-30 N-m).
To aim the luminaire, loosen the knuckle bolt, adjust the aim 0 to 45° , and tighten to 45-50 ft-lbs (61-68 N-m).
Inspect installation to ensure fixture is secure.
26.776 in.
[680 mm]
2.3 in.
[57 mm]
45° max upward aim
.656 in. (17 mm)
1.312 in. (33 mm)
FIGURE 5
5.0 in.
[127 mm]
7.3 in.
[186 mm]
R26.9 in.
[R683 mm]
Tighten Knuckle Bolt
to 45-50 Foot Pounds
3.805 in.
[97 mm]
ADAPTER PLATE FOR
SQUARE POLE
2-3/8 in. (60mm) to 3.0 in. (76mm) OD only
Tighten 3 Set Screws to 18-22
Foot Pounds
Nut Plate
Adapter Block
4
WIRING
CAUTION
Risk of Damage or Injury: Door should be closed with
screw until fixture in final location.
3/8-16 Washer and Bolts
Torque Bolts to 25 - 32ft-lbs.
(34-43 N-m)
FIGURE 6
• NOTE: Make all electrical connections in accordance with the National ­Electrical Code and any applicable ­
local code requirements.
• Strain relief for incoming power must be p
­ rovided in the pole top by the customer.
• Supply Wire Type and Size, for Customer Connection to Terminal Board: 16 AWG (1.5mm2) to 6 AWG (10mm2) Solid or Stranded.