Transcript
AN 131 ULTRA-ZONE HUMIDIFIER Z100 ASSEMBLY INSTALLATION INSTRUCTIONS & OWNER'S MANUAL Z100 REPLACEMENT INSTRUCTIONS SUPPLEMENT THE ULTRA-ZONE ELECTRONIC STEAM POWER HUMIDIFIERS SUPPLEMENT TOTO THE ELECTRONIC STEAM POWER MODEL #S2000 AND S2020 MODELHUMIDIFIERS # S2000 AND S2020 TheULTRA-ZONE Field Controlssteam Steam Humidifier now comes equipped a factory installed acts The humidifier now comes equipped withwith a factory installed Z100,Z100, whichwhich acts as a as a sacrificial metal. Put simply, minerals in the water will attack and cling to the Z100. The sacrificial metal. Put simply, the chemicals in the water will attack and cling to the Z100. The chemicals minerals will the not other attackcomponents the other components inside the longIsasactive. the Z100 is present will not attack inside the humidifier ashumidifier long as theasZ100 and active. This results in a dramatic decrease in chemical and scale build up on the stainless steel components This results in In a dramatic in mineral and scale up on element the critical components inside the tank. particular,decrease it means less scale build up on build the heating which is subject inside to damage excessiveitscaling heating. Thisonalso efficiency stays high andto the tank.from In particular, meansand lessover scale build up themeans heatingthat element which is subject faster and preventive maintenance damage from excessiveisscaling andeasier over.heating. This also means that efficiency stays high and preventive maintenance is faster and easier. The Z100 is positioned on the baffle plate inside the tank and is easily removed and replaced. Remember that the Z100’s to become target chemical it will beand heavily covered The Z100 is positioned onjob theisbaffle plate the inside theoftank and isattack, easily so removed replaced. with scale and should be replaced for best results. Remember that the Z100ʼs job isannually to become the target of mineral attack, so it will be heavily covered with scale and should be replaced annually for best results. To remove the Z100 you must have already unplugged and shutdown your steam humidifier and allowed it to the cool.Z100 The you watermust tankhave has been drained, the water drainyour linessteam and electrical wiring To remove already unplugged andsupply, shutdown humidifier and have been disconnected and the unit has been removed from the duct. allowed it to cool. The water tank has been drained, the water supply, drain lines and electrical wiring have been disconnected and the unit has been removed from the duct. Using a phillips screwdriver, remove the two screws that hold the baffle plate to the tank. Lift the baffle slightly back to clear the water probe and then straight up and out of the tank. You can then see the ReferZ100 to the blow up what view is onleft Page a phillips remove thebuild two screws that Z100 round , or rather of it 11. afterUsing a single season.screwdriver, Notice the heavy scale up on the hold the baffle plate to the tank. Lift the baffle slightly back to clear the water probe and then straight that would have been on your element, if the Z100 was not there. Use a rag or pliers to grasp the edges and outand of the tank.unscrew You canit then the round what is left it after ascale single Z100 ofupthe simply from see the baffle plate.Z100, Rinseoroffrather or wipe away anyofresidual from season. Notice the heavy scale build up on the Z100 that would have been on your element, if the the baffle plate and install the new Z100. Leave a slight gap between the bottom of the Z100 and the Z100plate. was not there. Use the a rag or pliers to grasp the and edges of the Z100 simply unscrew baffle Now re-insert baffle plate into the tank secure with the and two screws that wereit from the baffle plate. Rinse off or wipe away any residual scale from the baffle plate and install a new removed previously. It’s that simple. Z100. Leave a slight gap between the bottom of the Z100 and the baffle plate. Now re-insert the baffle plate the tank and secure with steam the two screws that were lay removed previously. Z100 The caninto also benefit the older model humidifiers. Simply the Z100 down intoItʼs thethat baffle simple. plate in the same location as the factory installed model. DO NOT lay the Z100 down into the main tank. It may come in contact with the heating element and damage it. The dimensions of the baffle Z100 The Z100 can benefit the older model steam humidifiers. Simply lay the Z100 down into the plate prevent thealso from falling down into the tank. baffle plate in the same location as the factory installed model. DO NOT lay the Z100 down into the The Z100 is Itjust thecome latestininnovation in the Steam line as dimensions we continue of in the our main tank. may contact with theULTRA-ZONE heating element andHumidifier damage it. The pursuit of Excellence Without baffle plate prevent the Z100Compromise. from falling down into the tank. P/N 090376A0131 P/N B090376A0131 C 10/2011 REV. COPYRIGHT REV. © 2002-2006, EWC Controls Inc., All Rights Reserved Copyright © 2011, Field Controls Inc., All Rights Reserved EWC Controls Inc. 385 Highway 33Airport Englishtown, NJ 07726 732-446-5362 FAX: [email protected] Field Controls Inc. 2630 Road Kinston, NC 800-446-3110 28504 PH: FAX 252.522.3031 252.522.0214