Download Emerson DLC3020f Instruction Manual
Transcript
Field Communicator Menu Tree FIELDVUE™ DLC3020f Digital Level Controller Overview Overview Check Status Primary Purpose Variables Shortcuts www.Fisher.com For the telephone number of the Emerson Process Management sales office nearest you, contact: In North America Fisher Controls International LLC 1 (641) 754‐3011 In Latin America Fisher Controls International LLC 1 (314) 746‐9900 Check Status Device Status: Good Failed Maintenance or Advisory Mode Status: In Service or Not in Service Shortcuts Device Information Calibration/Setup Logs DLC3020f Digital Level Controller In Asia Pacific Emerson Process Management Asia Pacific Private Ltd. (65) 6777‐8211 In Europe Emerson Process Management Ltd. +44 1634 895800 475 Field Communicator For equipment service or support needs, contact your local Emerson Process Management sales office www.Fisher.com D103602X012 May 2012 FIELDVUE and Fisher are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson, Emerson Process Management, and the Emerson logo are trademarks and service marks of Emerson Electric Co. © 2012 Fisher Controls International LLC. All rights reserved. Home Overview Configure Service Tools (on back side) Advanced Manual Setup Configure Instrument Setup Manual Setup Alert Setup (on back side) Calibrate (on back side) Temperature Compensation Temperature Input Temperature For Compensation (Visible if Temperature Input = None only) Calibration/Setup Log Methods View Restore Save Current Rename Delete Upper Fluid Fluid Name Density in Use Lower Fluid Fluid Name Density in Use Density Tables Upper Fluid Density Table Lower Fluid Density Table DLC3020f Digital Level Controller Device Information Device Overview Version Information Manufacturing Information Manufacturing Information Lever Assembly ID Communication Module ID Sensor Module ID Shop Order Number Terminal Box Date Code Calibration/Setup Logs Calibration in Use Calibration/Setup Log Methods Manual Setup Mode Device Process Fluid (Level only) Process Fluids (Interface only) Instrument Display Snap Acting Control Options (continued on back side) Process Fluids (Interface only) Upper Fluid Lower Fluid Change Process Fluid Temperature Compensation Density Tables Upper Fluid Density Table Lower Fluid Density Table Temperature 1 Density 1 Temperature 2 Density 2 ... ... Temperature 10 Density 10 Device Overview Instrument Model Number Instrument Serial Number Version Information Device Revision Firmware Revision Hardware Revision Major Sensor Revision Minor Sensor Revision DD Information Calibration In Use Name Date Calibration Method Calibrator Device Variable Configuration Sensor Units Sensor Parameters Torque Tube Sensor Hardware Information Process Fluid (Level only) Process Fluid Change Process Fluid Temperature Compensation Density Table Density Table Temperature 1 Density 1 Temperature 2 Density 2 ... ... ... ... Temperature 10 Density 10 Menu Tree applies to Device Revision Hardware Revision Firmware Revision DD Revision 1 1.0 1.0 0x03 Italics text = Method Variable Configuration Type of Measurement Primary Value Range High Primary Value Range Low Primary Value Offset Primary Value Range Units Sensor Parameters Displacer Length Displacer Volume Displacer Weight Driver Rod Length Instrument Mount Position Torque Tube Torque Tube Material Compensated Torque Rate Torque Tube Table Sensor Hardware Information Model Type End Connection Style End Connection Type Body Material Pressure Rating Mechanical Sensor Serial Number Displacer Size Displacer Material Displacer Rating G Dimension Torque Tube Material Torque Tube Wall Heat Insulator Temperature Compensation Temperature Input Temperature For Compensation (Visible if Temperature Input = None only) Sensor Units Unit System Length Units Volume Units Weight Units Temperature Units Torque Rate Units Fluid Density Units Torque Tube Table Temperature 1 Gain 1 Temperature 2 Gain 2 ... ... ... ... Temperature 10 Gain 10 Process Fluid Fluid Name Density in Use Manual Setup (continued) Configure Instrument Setup Manual Setup Alert Setup Calibrate Manual Setup (continued) Mode Device Process Fluid (Level) Process Fluids (Interface) Instrument Display Snap Acting Control Options Options Resource Block Tag Transducer Block Tag Write Lock Confirm Time Communication Timeout Function Block Available Features Selected Write Alarm Block Alarm Alert Key Block Alarm Block Alarm Disabled Block Alarm Alarm State Block Alarm Unacknowledged Write Alarm Disc Alarm Disabled Write Alarm Alarm State Write Alarm Unacknowledged Resource Block Tag Tag Description Strategy Transducer Block Tag Tag Description Strategy Instrument Display Display Option Device Display Primary Value Units Decimal Places Display Primary Value Offset Scroll Message Control Scroll Message Control Primary Value Bad Primary Value Uncertain Failed Alert Maintenance Alert Advisory Alert Snap Acting Control Primary Value Primary Value Percent Snap Acting Control Snap Units DI1 Trip Point Settings DI2 Trip Point Settings DI1 Trip Point Settings DI1 Action DI1 Trip Point DI1 Deadband DI1 Readback DI2 Trip Point Settings DI2 Action DI2 Trip Point DI2 Deadband DI2 Readback Write Lock Write Lock Write Priority Communication Timeout Shed Remote Cascade Shed Remote Out Function Block Available CasIn to Transducer Block Features Selected Reports Fault State Write Lock Reannunciation Alert Setup Configure Instrument Setup Manual Setup Alert Setup Calibrate Alert Setup Rapid Rate Limit (length/sec) Clear Rate Limit Alert PlantWeb Alert Enable PlantWeb Alert Reporting PlantWeb Alert Reporting Failed Suppress Maintenance Suppress Advisory Suppress Calibrate Configure Instrument Setup Manual Setup Alert Setup Calibrate Calibrate Calibration in Use Full Calibration (Bench) Full Calibration (Field) Expert User Calibration Bench Calibration Weight Min/Max Two Point Expert User Calibration Bench Calibration Field Calibration Trim Current Calibration Field Calibration Simple Zero/Span Min/Max Two Point Two Point Time Delay Trim Current Calibration Zero Trim Gain Trim Default Gain Service Tools Home Overview Configure Service Tools Advanced Service Tools Mode Alerts Variables Maintenance Simulate Maintenance Calibration/Setup Logs Restart Options LCD Test Simulate Simulate Alert Conditions Simulate Active Alerts PlantWeb Alert Enable Failed Enable Maintenance Enable Advisory Enable Calibration in Use Name Date Calibration Method Calibrator Simulate Active Alerts Failed Active Maintenance Active Advisory Active Primary Value Primary Value Primary Value Percent Variables Type of Measurement Primary Value Upper Fluid (Interface only) Lower Fluid (interface only) Process Fluid (Level only) Compensated Torque Rate Temperature Compensation Run Time Extremes Upper Fluid (Interface only) Fluid Name Density in Use Calibration/Setup Logs Calibration In Use Calibration/Setup Log Methods Process Fluid (Level only) Fluid Name Density in Use Calibration/Setup Log Methods View Restore Save Current Rename Delete LCD Test Enable/Disable LCD Test Device Display Test Display Primary Value Display Primary Value Percent Lower Fluid (Interface only) Fluid Name Density in Use Calibration In Use Name Date Calibration Method Calibrator Run Time Extremes Run Time Time Since Reset Instrument Temperature Maximum Recorded Temperature Minimum Recorded Temperature Time Over Upper Temperature Limit Time Under Lower Temperature Limit Temperature Integral (deg-days)