Types 627W and 627WH Note Startup It is important that the regulator be installed so that the vent hole in the spring case is unobstructed at all times. For outdoor installations, the regulator should be located away from vehicular traffic and positioned so that water, ice, and other foreign materials cannot enter the spring case through the vent. Avoid placing the regulator beneath eaves or downspouts, and be sure it is above the probable snow level. Overpressure Protection The recommended pressure limitations are stamped on the regulator nameplate. Some type of overpressure protection is needed if the actual inlet pressure exceeds the maximum operating outlet pressure rating. Overpressure protection should also be provided if the regulator inlet pressure is greater than the safe working pressure of the downstream equipment. Regulator operation below the maximum pressure limitations does not preclude the possibility of damage from external sources or debris in the line. The regulator should be inspected for damage after any overpressure condition. The regulator is factory set at approximately the midpoint of the spring range or the pressure requested, so an initial adjustment may be required to give the desired results. With proper installation completed and relief valves properly adjusted, slowly open the upstream and downstream shutoff valves. Adjustment To change the outlet pressure, remove the closing cap or loosen the locknut and turn the adjusting screw clockwise to increase outlet pressure or counterclockwise to decrease pressure. Monitor the outlet pressure with a test gauge during the adjustment. Replace the closing cap or tighten the locknut to maintain the desired setting. Taking Out of Service (Shutdown) To avoid personal injury resulting from sudden release of pressure, isolate the regulator from all pressure before attempting disassembly. Table 1. Maximum Spring and Diaphragm Casing Pressure(1) SPRING AND DIAPHRAGM CASING STYLE TYPE 627W bar (psig) TYPE 627WH psig (bar) Maximum pressure to spring and diaphragm casings to prevent leak to atmosphere (internal parts damage may occur) Ductile Iron 17,2 (250) --- --- Steel or Stainless Steel 17,2 (250) 55,2 (800) Maximum pressure to spring and diaphragm casings to prevent burst of casings during abnormal operation (leak to atmosphere and internal parts damage may occur) Ductile Iron 32,1 (465) --- --- Steel or Stainless Steel 103 (1500) 103 (1500) Maximum diaphragm casing overpressure (above setpoint) to prevent damage to internal parts. All Styles 4,1 (60) 8,3 (120) 1. If the spring case is pressurized, a metal adjusting screw cap is required. Table 2. Maximum Inlet Pressure, Differential Pressure, and Outlet Pressure Ranges TYPE OUTLET PRESSURE RANGE, SPRING PART NO., AND COLOR, BAR (psig) 0,69 to 1,4 (10 to 20) 10B 3076X 012 yellow 1,0 to 2,8 (15 to 40) 10B 3077X 012 green ORIFICE DIAMETER MAXIMUM INLET PRESSURE BAR (psig) MAXIMUM DIFFERENTIAL PRESSURE BAR (psig) elastomer disk nylon disk elastomer disk nylon disk 6,4 (1/4) 15,2 (220) 29,0 (420) 13,8 (200) 27,6 (400) 12,7 (1/2) 15,2 (220) 17,2 (250) 13,8 (200) 17,2 (250) 6,4 (1/4) 16,6 (240) 30,3 (440) 13,8 (200) 27,6 (400) 12,7 (1/2) 16,6 (240) 20,7 (300) 13,8 (200) 20,7 (300) 6,4 (1/4) 19,3 (280) 33,1 (480) 13,8 (200) 27,6 (400) 12,7 (1/2) 19,3 (280) 33,1 (480) 13,8 (200) 27,6 (400) 627W 2,4 to 5,5 (35 to 80) 10B 3079X 012 blue 4,8 to 10,3 (70 to 150) 10B 3078X 012 red 6,4 (1/4) 24,1 (350) 37,9 (550) 13,8 (200) 27,6 (400) 12,7 (1/2) 24,1 (350) 37,9 (550) 13,8 (200) 27,6 (400) 9,7 to 17,2 (140 to 250) 10B 3078X 012 blue 6,4 (1/4) 31,0 (450) 44,8 (650) 13,8 (200) 27,6 (400) 12,7 (1/2) 31,0 (450) 34,5 (500) 13,8 (200) 17,2 (250) 6,4 (1/4) 48,3 (700) 62,1 (900) 13,8 (200) 27,6 (400) 12,7 (1/2) 48,3 (700) 51,7 (750) 13,8 (200) 17,2 (250) 627WH 16,6 to 34,5 (240 to 500) 10B 3079X 012 red 2