Download Dell OpenManage Server Administrator Version 7.3 Software Support
Transcript
Controller Starting RAID Level Target RAID Level Comments PERC 6/E, PERC 6/I, CERC 6/I, PERC H800 Adapter, PERC H700 Adapter, PERC H700 Integrated, and PERC H700 Modular, PERC H310 Adapter, PERC H310 Mini Monolithic, PERC H310 Mini Blades, PERC H710 Adapter, PERC H710 Mini Blades, PERC H710 Mini Monolithic, PERC H710P Adapter, PERC H710P Mini Blades, PERC H710P Mini Monolithic, PERC H810 Adapter RAID 0 RAID 1 Add a single disk RAID 0 RAID 0, RAID 5 Add at least one additional disk. RAID 0 RAID 6 RAID 6 requires a minimum of 4 disks. Reconfiguration from RAID 0 to RAID 6 requires at least 2 additional disks even when this exceeds the 4disk minimum required by RAID 6 RAID 1 RAID 0 With or without adding additional disks RAID 1 RAID 5, RAID 6 Add at least one additional disk. RAID 6 requires a minimum of 4 disks. RAID 5 RAID 0 With or without adding additional disks RAID 5 RAID 5, RAID 6 Add at least one additional disk. RAID 6 requires a minimum of 4 disks. RAID 6 RAID 0, RAID 5 With or without adding additional disks RAID 6 RAID 6 Add at least one additional disk SAS 6/iR N/A N/A N/A PERC S100, S110, and S300 RAID 0 RAID 0 With or without additional disks RAID 1 RAID 1 Without additional disks RAID 5 RAID 5 With or without additional disks RAID 10 RAID 10 Without additional disks Related Links Choosing RAID Levels And Concatenation Maintaining The Integrity Of Redundant Virtual Disks Does my controller support this feature? See Supported Features. The virtual disk Check Consistency task verifies the accuracy of the redundant (parity) information. This task only applies to redundant virtual disks. When necessary, the Check Consistency task rebuilds the redundant data. 136