systemSlotHotPlugCanSignal PowerFault(16) Power on fault (and corresponding LED) can be detected due to a short or overcurrent. systemSlotHotPlugCanSignal AdapterPresent(32) Adapter (card) present in slot (may not be powered) can be detected. systemSlotHotPlugCanSignal PowerButtonPressed(64) The system slot power button can be pressed to signal a toggle of the power state. canSupportAllHotPlugCapabi lities(126) The system slot can support all hot-plug capabilities. systemSlotHotPlugIsUnknown (1) The system slot’s capabilities are unknown. systemSlotCanProvide5Volts (128) The system slot can provide a 5-volt (V) supply. systemSlotCanProvide3Point 3Volts(256) The system slot can provide a 3.3-V supply. systemSlotCanSignalIfShared (512) The system slot’s opening, if shared with another slot, can be detected. systemSlotCanSupportCard16 (1024) The system slot can support PC Card-16. systemSlotCanSupportCardBus (2048) The system slot can support CardBus. systemSlotCanSupportZoomVid eo(4096) The system slot can support Zoom Video. systemSlotCanSupportModem RingResume(8192) The system slot can support modem ring resume. systemSlotCanSupportPMESig nal(16384) The system slot can support Power Management Enable (PME#) signal. canSupportAllSlotCapabilit ies(32640) The system slot can support all slot capabilities. Table 880. System Slot State Settings Variable Name: DellSystemSlotStateSettings Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugIsUnknown(1) The system slot’s capabilities are unknown. systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug. systemSlotHotPlugIsPoweredOn(4) The system slot power (and corresponding LED) can be powered on. systemSlotHotPlugIsAtAttention(8) The system slot attention state (and corresponding LED) can be set. systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug. systemSlotHotPlugIsPoweredOn(4) The system slot power (and corresponding LED) is on. systemSlotHotPlugIsAtAttention(8) The system slot attention state (and corresponding LED) is on. systemSlotHotPlugHasPowerFaulted (16) Power on fault (and corresponding LED) was detected due to a short or overcurrent. 261
Related documents
Dell OpenManage Server Administrator Version 7.3 SNMP Reference Guide
Dell OpenManage Server Administrator Version 7.4 SNMP Reference Guide
Dell OpenManage Server Administrator Version 6.0.1 SNMP Reference Guide
Dell OpenManage Server Administrator Version 6.5 SNMP Reference Guide
Dell OpenManage Server Administrator Version 5.5 SNMP Reference Guide
Dell OpenManage Server Administrator Version 7.0 SNMP Reference Guide
Dell OpenManage Server Administrator Version 5.4 SNMP Reference Guide
Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS SNMP Reference Guide
Dell OpenManage Server Administrator Version 6.2 SNMP Reference Guide
Dell OpenManage Server Administrator Version 5.2 SNMP Reference Guide