Download CH Tech VX402C-64 User's Manual
Transcript
C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com U S E R ’ S ACTIVE MODULE CARRIER MODEL VX402C-64 Document Part No: 11028504B M A N U A L COPYRIGHT C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com C&H Technologies, Inc. (C&H) provides this manual "as is" without warranty of any kind, either expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. C&H may make improvements and/or changes in the product(s) and/or program(s) described in this manual at any time and without notice. This publication could contain technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of this publication. Copyright © 2002, 2008 by C&H Technologies, Inc. The information and/or drawings set forth in this document and all rights in and to inventions disclosed herein which might be granted thereon disclosing or employing the materials, methods, techniques or apparatus described herein, are the exclusive property of C&H Technologies, Inc. A Reader's Comment Form is provided at the back of this publication. If this form has been removed address comments to: C&H Technologies, Inc. Technical Publications 445 Round Rock West Drive Austin, Texas 78681-5012 Or visit our web site for support information at: http://www.chtech.com. C&H may use or distribute any of the information you supply in any way that it believes appropriate without incurring any obligations. . ii C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com AMENDMENT NOTICE C&H Technologies, Inc. makes every attempt to provide up-to-date manuals with the associated equipment. Occasionally, changes are made to the equipment wherein it is necessary to provide amendments to the manual. If any amendments are provided for this manual they are printed on colored paper and will be provided with the module and manual. Manual updates may also be found on out web site at www.chtech.com. NOTE The contents of any amendment may affect operation, maintenance, or calibration of the equipment. REVISION HISTORY Rev * A B Date 03-20-2002 09-13-2004 07-10-2008 Description Original release Corrected Figure A-3 (J1) & A-4 (J2) Pin Configurations Added -0003 and -0004 version information Clarified Electrical information (Section 1.2.2) Clarified Pass-Through Cable information (Section 3.3.3) iii INTRODUCTION C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com This manual describes the operation and use of the C&H Model VX402C-64 VXI Active Carrier Module (Part Number 11028500 Revision B or higher). This VXI module is one of a number of test and data acquisition/control modules in the VME and VXI format provided by C&H. Contained within this manual are the physical and electrical specifications, installation and startup procedures, functional description, and configuration guidelines to adequately use the product. The part numbers covered by this manual are: Part Number 11028500-0001 11028500-0002 11028500-0003 11028500-0004 Description VX402C-64 (with +3.3V supplied from VXI +5V) VX402C-64 (without +3.3V supply) VX402C-64 (with +3.3V supplied from VXI -24V) VX402C-64 (with +3.3V supplied from VXI +24V) iv C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com TABLE OF CONTENTS 1.0 GENERAL DESCRIPTION ..................................................................................................... 7 1.1 PURPOSE OF EQUIPMENT........................................................................................ 7 1.2 SPECIFICATIONS OF EQUIPMENT.......................................................................... 8 1.2.1 Key Features .................................................................................................. 8 1.2.2 Electrical ........................................................................................................ 8 1.2.3 Mechanical................................................................................................... 10 1.2.4 Environmental.............................................................................................. 10 1.2.5 Bus Compliance ........................................................................................... 10 2.0 INSTALLATION .................................................................................................................... 11 2.1 UNPACKING AND INSPECTION ............................................................................ 11 2.2 HANDLING PRECAUTIONS.................................................................................... 11 2.3 INSTALLATION ........................................................................................................ 11 2.4 PREPARATION FOR RESHIPMENT....................................................................... 11 3.0 FUNCTIONAL DESCRIPTION ............................................................................................. 13 3.1 GENERAL .................................................................................................................. 13 3.2 TRIGGERS.................................................................................................................. 14 3.2.1 TTL TRIGGERS .......................................................................................... 14 3.2.2 ECL TRIGGERS.......................................................................................... 15 3.3 CONNECTORS........................................................................................................... 15 3.3.1 VXI REAR Connectors................................................................................ 15 3.3.2 VME-64 FRONT CONNECTORS............................................................... 15 3.3.3 PASS-THROUGH CONNECTORS............................................................. 16 3.4 SUMBUS CONFIGURATION .................................................................................... 18 3.4.1 SUMBUS CUSTOM AREA ......................................................................... 18 3.4.2 SUMBUS JUMPER SETTINGS................................................................... 19 4.0 OPERATING INSTRUCTIONS ............................................................................................. 21 APPENDIX A - CONNECTORS................................................................................................ A-1 v C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com LIST OF FIGURES Figure 1. Front Panel and Top View (Top Shield Not Shown) .......................................................7 Figure 2. Power Schematic (-0001 version)....................................................................................8 Figure 3. Power Schematic (-0002 version)....................................................................................9 Figure 4. Power Schematic (-0003 & -0004 versions)....................................................................9 Figure 5. Functional Block Diagram .............................................................................................13 Figure 6. TTL Trigger Direction....................................................................................................14 Figure 7. ECL Trigger Direction ...................................................................................................15 Figure 8. Pass-Through Connector Location ................................................................................16 Figure 9. SUMBUS Custom Area..................................................................................................18 Figure 10. SUMBUS Jumper Settings............................................................................................19 LIST OF TABLES Table I. Power Supply Capabilities...............................................................................................10 Table II. VXI/VME Pass-Through Connections ...........................................................................17 vi 1.0 GENERAL DESCRIPTION The carrier provides an actively-buffered electrical interface for the standard VME bus signals. The VX402C-64 does not support the full VME64 extension bus; however, -0001, -0003, and -0004 versions provide +3.3V power to the P1 row D VME64 extension. The adapter also features a VXI C-size mechanical enclosure to support and shield the VME module. The carrier and its enclosure have been designed so that the front panel of the VME module sits flush with the front panels of other C-size modules as shown in Figure 1. The VX402C-64 supports interrupts and provides a capability for bringing P2 VME signals to the front panel. The carrier also supports VXI VXITTL triggers and a prototype area is provided for buffering the VXI SUMBUS signal. These features allow the VME module to transparently interface to a C-size chassis. VME P1 USER’S VME MODULE C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com The VX402C-64 Active Carrier allows an A- or B-size VME, VXI, or VME64 module to be used in a C-size VXI mainframe chassis. Throughout the rest of this manual, the VME/VXI card being carried will be referred to as the VME module. J1 USER’S VME MODULE P1 VX402C-64 P2 J2 P2 VME Figure 1. Front Panel and Top View (Top Shield Not Shown) 1.1 PURPOSE OF EQUIPMENT This VX402C-64 was designed to provide an interface for using B-size VME modules in a VXI C-size chassis. The active nature of the module allows extensions of the VXI bus without violation of VME/VXI electrical bus standards. 7 1.2 SPECIFICATIONS OF EQUIPMENT 1.2.1 Key Features Provides direct access to the VME module’s front panel I/O connections C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com Supplies buffered data, address, interrupt, and trigger lines (ECL and TTL) Includes direct SUMBUS connections, as well as a prototyping area with fused ±12V power supplies for buffered SUMBUS connections (jumper selectable) Conforms with VMEbus/VXIbus driving and loading specifications Provides VME64 +3.3V supplies (-0001, -0003, and -0004 versions only) Mates with VXI, VME, and VME64 rear connectors 1.2.2 Electrical The -0001, -0003, and -0004 versions provide +3.3V power to the P1 row D VME64 extension. The -0002 version does not provide +3.3V power. A simplified power schematic for each version is shown in Figure 2, Figure 3, and Figure 4. Excluding the +3.3V supply, the VX402C64 only requires 300mA of +5V power from the VXI backplane. This power requirement is for the VX402C-64 alone. Any attached module will increase this value by the amount specified in its data sheet. Table I provides a summary of the supply capabilities of each version. The table assumes that the VXI backplane is capable providing 1.2A on each of the seven +5V power pins. For versions -0003 and -0004, 1.2A on the -24V and +24V pins. VXI BACKPLANE VME64 CONNECTORS +5V (7 PINS) +5V DC-DC CONVERTER (7 PINS) +3.3V (10 PINS) INTERNAL LOGIC GND GND Figure 2. Power Schematic (-0001 version) 8 C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com VXI BACKPLANE VME64 CONNECTORS +5V +5V (7 PINS) (7 PINS) INTERNAL LOGIC GND GND Figure 3. Power Schematic (-0002 version) VXI BACKPLANE VME64 CONNECTORS +5V +5V (7 PINS) (7 PINS) INTERNAL LOGIC GND +24V or -24V GND ISOLATED DC-DC CONVERTER (1 PIN) OUTOUT+ +3.3V (10 PINS) Figure 4. Power Schematic (-0003 & -0004 versions) 9 C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com Table I. Power Supply Capabilities VXI +5V Supply Capability VXI +24V Supply Capability VXI -24V Supply Capability Internal +5V Power Consumption Remaining +5V Power Available +3.3V Converter Efficiency +5V Power Available to VME Module +3.3V Power Available to VME Module -0001 42.0W not used not used 1.5W 40.5W 92% 37W Total VX402C-64 Version -0002 -0003 42.0W 42.0W not used not used not used 29W 1.5W 1.5W 40.5W 40.5W n/a 40.5W 0W 80% 40.5W 23W -0004 42.0W 29W not used 1.5W 40.5W 80% 40.5W 23W n/a = not applicable 1.2.3 Mechanical The mechanical dimensions of the VX402C-64 are in conformance with the VXI bus specification for the height and width of Size-C modules. The nominal dimensions are 233.35 mm (9.187 in) high x 156.337 mm (6.155 in) deep. Once the VX402C-64 is adapted to a VME module, the total dimensions are 233.35 mm (9.187 in) high x 340.0 mm (13.386 in) deep. The module is designed for a mainframe with 30.48 mm (1.2 in) spacing between slots. 1.2.4 Environmental The environmental specifications of the module are: Operating Temperature: Storage Temperature: Humidity: 0C to +55C -40C to +75C <95% without condensation 1.2.5 Bus Compliance The module complies with the VXIbus Specification Revision 1.4 and with VMEbus Specification ANSI/IEEE STD 1014-1987, IEC 821 and IEC 822. Module: Device Type: VME to VXI Extender Active Carrier 10 2.0 INSTALLATION C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com 2.1 UNPACKING AND INSPECTION In most cases the VX402C-64 is individually sealed and packaged for shipment. Verify that there has been no damage to the shipping container. If damage exists then the container should be retained as it will provide evidence of carrier caused problems. Such problems should be reported to the carrier immediately as well as to C&H. If there is no damage to the shipping container, carefully remove the module from its box and anti static bag and inspect for any signs of physical damage. If damage exists, report immediately to C&H. 2.2 HANDLING PRECAUTIONS The VX402C-64 contains components that are sensitive to electrostatic discharge. When handling the module for any reason, do so at a static-controlled workstation, whenever possible. At a minimum, avoid work areas that are potential static sources, such as carpeted areas. Avoid unnecessary contact with the components on the module. 2.3 INSTALLATION CAUTION: Read the entire User's Manual before proceeding with the installation and application of power. If necessary, remove the shield from the VX402C-64 and configure the switches and jumpers. Replace the shield and insert the carrier into the appropriate slot according to the desired priority. Insert the VME module through the front panel of the VX402C-64. Push firmly until the VME module’s rear connectors are fully inserted into the front connector of the VX402C-64. Apply power. If no obvious problems exist, proceed to communicate with the VME module. The VX402C-64 connectors require high insertion force to completely connect with the VME module. If it is difficult to assemble the unit through the front panel, it is recommended that the VX402C-64 shield be removed, and the boards be mated before insertion into the chassis. 2.4 PREPARATION FOR RESHIPMENT If the module is to be shipped separately it should be enclosed in a suitable water and vapor proof anti static bag. Heat seal or tape the bag to insure a moisture-proof closure. When sealing the bag, keep trapped air volume to a minimum. The shipping container should be a rigid box of sufficient size and strength to protect the equipment from damage. If the module was received separately from a C&H system, then the original module shipping container and packing material may be re-used if it is still in good condition. 11 12 C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com 3.0 FUNCTIONAL DESCRIPTION C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com 3.1 GENERAL VX402C-64 is a general purpose carrier module for VXI C-Size chasses. The module provides actively buffered signals, which meet all VME specifications, to the VME module. A functional block diagram is shown in Figure 5. P1 J1 Trigger Buffer Interrupt Buffer To VME Module Address Buffer P2 J2 Data Buffer Pass-Through Connectors Trigger Buffer Figure 5. Functional Block Diagram 13 To VXI Backplane 3.2 TRIGGERS C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com Both ECL and TTL triggers are supplied through the VX402C-64. There are switches on the carrier which are used to set the direction of the triggers (to the backplane and from the backplane). 3.2.1 TTL TRIGGERS Eight TTL Trigger lines pass through the VX402C-64 to the front panel: TTLTRG0-7. Each trigger line may be set as an input or output trigger. The trigger direction is set using switch S1 which can be seen in Figure 6. The directions are also clearly marked on the board itself. ` J1 P1 S1 TTLTRG0 TTLTRG1 1 ON TTLTRG2 TTLTRG3 TTLTRG4 TTLTRG5 TTLTRG6 TTLTRG7 J2 P2 S1 TO BACKPLANE FROM BACKPLANE TTLTRG Figure 6. TTL Trigger Direction 14 3.2.2 ECL TRIGGERS C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com The VX402C-64 supports two ECL Trigger lines: ECLTRG0-1. Each trigger line may be set as an input or output trigger. The trigger direction is set using switch S2 which can be seen in Figure 7. The trigger directions are clearly marked on the board itself. J1 P1 S2 ECLTRG0 ECLTRG1 1 ON S2 TO BACKPLANE FROM BACKPLANE ECLTRG J2 P2 Figure 7. ECL Trigger Direction 3.3 CONNECTORS 3.3.1 VXI REAR Connectors The P1 and P2 connectors are configured in accordance with the VXI specification and utilize the ECL and TTL trigger lines. Pinout details for the rear connectors can be found in Appendix A. 3.3.2 VME-64 FRONT CONNECTORS The VX402C-64 interfaces with the VME module through two 160 pin VME-64 connectors: J1 and J2. These connectors conform to VME and VXI specifications and can accept both 160 pin VME-64 (DIN 41 612 type C) and standard 96 pin VME/VXI connectors. Pinout details for the front connectors can be found in Appendix A. 15 C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com 3.3.3 PASS-THROUGH CONNECTORS One major difference between the VME bus and the VXI bus is that the outer rows of the P2 connector are not defined on the VME bus and they are defined on the VXI bus. For this reason, the VX402C-64 Active Module Carrier provides a Pass-Through Connector system that be used to optionally connect or not connect the VME P2 Rows A & C signals to the VXI P2 Rows A & C signals. The VX402C-64 can be shipped with an optional pass-through connector cable (110285080001). This cable is used to make internal connections between the P2 and J2 connectors on the VX402C-64. When the cable is installed, signals on the J2 connector of the VME module are routed to signals on the P2 connector of the backplane. Only use this cable for modules which utilize the outer rows on the J2 connector and completely adhere to the VXI specification. If the VME module has no outer row connections, it is unnecessary to install the cable. If the VME module has P2 signals which do not conform to the VXI spec, it may be necessary to make a custom pass-through cable. Also, if the VME module does not support the outer row of the J2 connector, a longer cable may be used to directly access these signals. Pinout details for the pass-through connectors can be found in Appendix A. Figure 8 shows the placement of the pass-through connectors on the VX402C-64. J1 P1 Pass-Through Connectors To J2 Front Connector To P2 Rear Connector P2 J2 J12 J11 Figure 8. Pass-Through Connector Location 16 C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com A one-to-one cable that connects Pin 1 (C32) on the VXI side to Pin 1 (C32) on the VME side, and so on, could only be used if the VME module was designed to meet all of the VXI bus specifications for these pins. If the installed VME module can not handle -24V, +24V, -5.2V or any other signal on the corresponding pin, then a one-to-one cable can not be used. The signal list for both the VXI side and the VME side is shown in Table II. The pass-through connectors on the PCB are standard 64-pin (32x2) shrouded headers, specifically Samtec TST132-01-S-D. Mating connectors are very common in both IDC and discreet wire varieties. Table II. VXI/VME Pass-Through Connections VXI SIDE PASS-THROUGH CONNECTOR PIN 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 P2 C32 C31 C30 C29 C28 C27 C26 C25 C24 C23 C22 C21 C20 C19 C18 C17 C16 C15 C14 C13 C12 C11 C10 C9 C8 C7 C6 C5 C4 C3 C2 C1 SIGNAL -24V +24V GND RSV3 GND TTLTRG7* TTLTRG5* GND TTLTRG3* TTLTRG1* GND LBUSC11 LBUSC10 -5.2V LBUSC09 LBUSC08 GND LBUSC07 LBUSC06 -2V LBUSC05 LBUSC04 GND LBUSC03 LBUSC02 GND LBUSC01 LBUSC00 -5.2V GND CLK10CLK10+ PIN 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 P2 A32 A31 A30 A29 A28 A27 A26 A25 A24 A23 A22 A21 A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 VME SIDE PASS-THROUGH CONNECTOR SIGNAL SUMBUS GND MODID RSV2 GND TTLTRG6* TTLTRG4* +5V TTLTRG2* TTLTRG0* GND LBUSA11 LBUSA10 -5.2V LBUSA09 LBUSA08 GND LBUSA07 LBUSA06 -5.2V LBUSA05 LBUSA04 GND LBUSA03 LBUSA02 -5.2V LBUSA01 LBUSA00 GND ECLTRG1 -2V ECLTRG0 PIN 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 P2 C32 C31 C30 C29 C28 C27 C26 C25 C24 C23 C22 C21 C20 C19 C18 C17 C16 C15 C14 C13 C12 C11 C10 C9 C8 C7 C6 C5 C4 C3 C2 C1 SIGNAL USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF PIN 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 P2 A32 A31 A30 A29 A28 A27 A26 A25 A24 A23 A22 A21 A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 SIGNAL USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF USER DEF To use the VXI TTLTRG signals, a custom cable should be used that connects each TTLTRG signal to the desired VME P2 connector signal. The VX402C-64 has a set of eight switches that are set to specify the direction of the trigger signal as shown Figure 6. If the trigger signal is an input to the VME module, the switch should be ON (closed). If the trigger signal is output from the VME module, the switch should be OFF (open). 17 3.4 SUMBUS CONFIGURATION C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com The VX402C-64 provides a direct connection of the SUMBUS signal through the pass-through connector to the front connectors. The board also has a prototyping area so that the user can hardwire a custom buffer for the SUMBUS signal. 3.4.1 SUMBUS CUSTOM AREA The SUMBUS custom area consists of a prototyping grid, ±12V supplies, and two jumpers for configuring the signal. The prototyping area is a 10x10 grid of 0.1” spaced through-hole pads which can be used in any way desired. The SUMBUS signal can be wired to the prototyping area using the two pads next to jumpers J21 and J13, and the jumpers must be configured to the proper setting. The location of the custom area can be seen in Figure 9. J1 P1 J2 P2 SUMBUS CUSTOM AREA -12V +12V J21 J13 Figure 9. SUMBUS Custom Area 18 3.4.2 SUMBUS JUMPER SETTINGS C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com In order to use the SUMBUS signal, the jumpers J11 and J12 must be configured properly. The three different settings for the jumpers can be seen in Figure 10. The SUMBUS signal can be connected directly to the front panel (A), connected through the prototyping area (B), or disconnected (C). The pass-through connector must be installed for the SUMBUS signal to route to the front panel. Also, both jumpers must be configured the same, or the SUMBUS signal will be disconnected. J21 J13 J21 J13 J21 J13 DIR DIR DIR SUMBUS SUMBUS SUMBUS CUST CUST CUST Direct Connection Custom Connection (A) (B) Figure 10. SUMBUS Jumper Settings 19 Disconnected (C) 20 C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com 4.0 OPERATING INSTRUCTIONS C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com While the VX402C-64 is an active carrier, it is designed to be completely transparent to the host interface. For this reason, the VME module can be accessed as if it were plugged directly into the host backplane. In order to operate the VME module, first set up the hardware configurations on the VX402C-64. Then set the necessary trigger directions using the switches. Ensure the jumpers are set for proper SUMBUS signal routing. Install or remove the pass-through connector cable as desired and replace the shield if necessary. The unit is now ready to be inserted into the chassis. Next, install the VME module into the front connectors of the VX402C-64. Once power is applied, the VME module can be readily accessed as if it were plugged directly in the backplane. 21 22 C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com APPENDIX A - CONNECTORS PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 C D08 D09 D10 D11 D12 D13 D14 D15 GND SYSFAIL* BERR* SYSRESET* LWORD* AM5 A23 A22 A21 A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A09 A08 +12 V +5 V B ACFAIL* BGIN0* BGOUT0* BGIN1* BG0UT1* BGIN2* BG0UT2* BGIN3* BGOUT3* AM0 AM1 AM2 AM3 GND GND IRQ7* IRQ6* IRQ5* IRQ4* IRQ3* IRQ2* IRQ1* +5VSTBY +5 V A D00 D01 D02 D03 D04 D05 D06 D07 GND SYSCLK GND DS1* DS0* WRITE* GND DTACK* GND AS* GND IACK* IACKIN* IACKOUT* AM4 A07 A06 A05 A04 A03 A02 A01 -12 V +5 V Figure A-1. P1 Pin Configuration NOTE: BGINx tied directly to BGOUTx A-1 C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 C CLK10+ CLK10GND -5.2V LBUSC00 LBUSC01 GND LBUSC02 LBUSC03 GND LBUSC04 LBUSC05 -2V LBUSC06 LBUSC07 GND LBUSC08 LBUSC09 -5.2V LBUSC10 LBUSC11 GND TTLTRG1* TTLTRG3* GND TTLTRG5* TTLTRG7* GND RSV3 GND +24V -24V B +5V GND RSV1 A24 A25 A26 A27 A28 A29 A30 A31 GND +5V D16 D17 D18 D19 D20 D21 D22 D23 GND D24 D25 D26 D27 D28 D29 D30 D31 GND +5V A ECLTRG0 -2V ECLTRG1 GND LBUSA00 LBUSA01 -5.2V LBUSA02 LBUSA03 GND LBUSA04 LBUSA05 -5.2V LBUSA06 LBUSA07 GND LBUSA08 LBUSA09 -5.2V LBUSA10 LBUSA11 GND TTLTRG0* TTLTRG2* +5V TTLTRG4* TTLTRG6* GND RSV2 MODID GND SUMBUS Figure A-2. P2 Pin Configuration A-2 C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 D GND +3.3V +3.3V +3.3V +3.3V +3.3V +3.3V +3.3V +3.3V +3.3V +3.3V GND - C BD08 BD09 BD10 BD11 BD12 BD13 BD14 BD15 GND BSYSFAIL* BBERR* BSYSRESET* BLWORD* BAM5 BA23 BA22 BA21 BA20 BA19 BA18 BA17 BA16 BA15 BA14 BA13 BA12 BA11 BA10 BA09 BA08 +12 V +5 V B BACFAIL* IN0* OUT0* IN1* 0UT1* IN2* 0UT2* IN3* OUT3* BAM0 BAM1 BAM2 BAM3 GND GND BIRQ7* BIRQ6* BIRQ5* BIRQ4* BIRQ3* BIRQ2* BIRQ1* +5VSTBY +5 V A BD00 BD01 BD02 BD03 BD04 BD05 BD06 BD07 GND BSYSCLK GND BDS1* BDS0* BWRITE* GND BDTACK* GND BAS* GND BIACK* BIACKIN* BIACKOUT* BAM4 BA07 BA06 BA05 BA04 BA03 BA02 BA01 -12 V +5 V Figure A-3. J1 Pin Configuration NOTES: 1. INx tied directly to OUTx. 2. +3.3V supplied on Version -0001 only A-3 Z GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 D GND - C CLK10+n CLK10-n GND14 -5.2V5 LBUSC00n LBUSC01n GND12 LBUSC02n LBUSC03n GND10 LBUSC04n LBUSC05n -2V1 LBUSC06n LBUSC07n GND08 LBUSC08n LBUSC09n -5.2V1 LBUSC10n LBUSC11n GND06 BTTLTRG1* BTTLTRG3* GND05 BTTLTRG5* BTTLTRG7* GND03 RSV3n GND02 +24Vn -24Vn B +5V GND RSV1 BA24 BA25 BA26 BA27 BA28 BA29 BA30 BA31 GND +5V BD16 BD17 BD18 BD19 BD20 BD21 BD22 BD23 GND BD24 BD25 BD26 BD27 BD28 BD29 BD30 BD31 GND +5V A BECLTRG0 -2V2 BECLTRG1 GND13 LBUSA00n LBUSA01n -5.2V4 LBUSA02n LBUSA03n GND11 LBUSA04n LBUSA05n -5.2V3 LBUSA06n LBUSA07n GND09 LBUSA08n LBUSA09n -5.2V2 LBUSA10n LBUSA11n GND07 BTTLTRG0* BTTLTRG2* +5Vn BTTLTRG4* BTTLTRG6* GND04 RSV2n MODIDn GND01 BSUMBUSn Figure A-4. J2 Pin Configuration NOTES: 1. Signals on Rows A & C are only connected, if the pass-through cable is installed. 2. +3.3V supplied on Version -0001 only A-4 Z GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com PIN 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 TO FRONT CONNECTOR J2 PIN -24Vn 2 BSUMBUSn +24Vn 4 GND01 GND02 6 MODIDn RSV3n 8 RSV2n GND03 10 GND04 BTTLTRG7*n 12 BTTLTRG6*n BTTLTRG5*n 14 BTTLTRG4*n GND05 16 +5Vn BTTLTRG3*n 18 BTTLTRG2*n BTTLTRG1*n 20 BTTLTRG0*n GND06 22 GND07 LBUSC11n 24 LBUSA11n LBUSC10n 26 LBUSA10n -5.2V1 28 -5.2V2 LBUSC09n 30 LBUSA09n LBUSC08n 32 LBUSA08n GND08 34 GND09 LBUSC07n 36 LBUSA07n LBUSC06n 38 LBUSA06n -2V1 40 -5.2V3 LBUSC05n 42 LBUSA05n LBUSC04n 44 LBUSA04n GND10 46 GND11 LBUSC03n 48 LBUSA03n LBUSC02n 50 LBUSA02n GND12 52 -5.2V4 LBUSC01n 54 LBUSA01n LBUSC00n 56 LBUSA00n -5.2V5 58 GND13 GND14 60 BECLTRG1n CLK10-n 62 -2V2 CLK10+n 64 BECLTRG0n PIN 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 TO REAR CONNECTOR P2 PIN -24V 2 BSUMBUS +24V 4 GND GND 6 MODID RSV3 8 RSV2 GND 10 GND BTTLTRG7* 12 BTTLTRG6* BTTLTRG5* 14 BTTLTRG4* GND 16 +5V BTTLTRG3* 18 BTTLTRG2* BTTLTRG1* 20 BTTLTRG0* GND 22 GND LBUSC11 24 LBUSA11 LBUSC10 26 LBUSA10 -5.2V 28 -5.2V LBUSC09 30 LBUSA09 LBUSC08 32 LBUSA08 GND 34 GND LBUSC07 36 LBUSA07 LBUSC06 38 LBUSA06 -2V 40 -5.2V LBUSC05 42 LBUSA05 LBUSC04 44 LBUSA04 GND 46 GND LBUSC03 48 LBUSA03 LBUSC02 50 LBUSA02 GND 52 -5.2V LBUSC01 54 LBUSA01 LBUSC00 56 LBUSA00 -5.2V 58 GND GND 60 BECLTRG1 CLK1062 -2V CLK10+ 64 BECLTRG0 Figure A-5. P2 Pin Configuration A-5 A-6 C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com NOTES: C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com READER'S COMMENT FORM C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com Your comments assist us in improving the usefulness of C&H's publications; they are an important part of the inputs used for revision. C&H Technologies, Inc. may use and distribute any of the information that you supply in any way that it believes to be appropriate without incurring any obligation whatsoever. You may, of course, continue to use the information which you supply. Please refrain from using this form for technical questions or for requests for additional publications; this will only delay the response. Instead, please direct your technical questions to your authorized C&H representative. COMMENTS: Thank you for helping C&H to deliver the best possible product. Your support is appreciated. Sincerely, F.R.Harrison President and CEO C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com INSTRUCTIONS In its continuing effort to improve documentation, C&H Technologies, Inc. provides this form for use in submitting any comments or suggestions that the user may have. This form may be detached, folded along the lines indicated, taped along the loose edge (DO NOT STAPLE), and mailed. Please try to be as specific as possible and reference applicable sections of the manual or drawings if appropriate. Also, indicate if you would like an acknowledgment mailed to you stating whether or not your comments were being incorporated. NOTE: This form may not be used to request copies of documents or to request waivers, deviations, or clarification of specification requirements on current contracts. Comments submitted on this form do not constitute or imply authorization to waive any portion of the referenced document(s) or to amend contractual requirements. (Fold along this line) (Fold along this line) Place Stamp Here ______________________ ______________________ ______________________ C&H Technologies, Inc. Technical Publications 445 Round Rock West Drive Round Rock, Texas 78681