Download American Standard Townsend Champion 4 Round Front Height Toilet 3180.016 User's Manual

Transcript
TOWNSEND CHAMPION® 4
ROUND FRONT RIGHT HEIGHT™ TOILET
VITREOUS CHINA
TOWNSEND CHAMPION ® 4 ROUND FRONT
RIGHT HEIGHT™ TOILET
❑ 2735.014
•Vitreous china
•EverClean™ anti-microbial surface which
inhibits the growth of stain and odor causing
bacteria, mold, and mildew
•Low-consumption (6.0 Lpf/1.6 gpf)
• Features Champion®4 Flushing System
performance platform
•4" non-adjustable, piston action Accelerator™
flush valve
•16-1/2" rim height for accessible applications
•Round Front siphon action jetted bowl
•2-3/8" fully-glazed trapway
•Speed Connect™ tank/bowl coupling system
•Chrome-plated trip lever
•Sanitary pier on bowl
•100% factory flush tested
•2 bolt caps
•10 year warranty
FINISHED WALL
721mm
(28-3/8)
19mm ± 6mm
(1 ± 1/4)
216mm
(8-1/2)
❑ 3180.016 Round Front Right Height™ Bowl
❑ 4281.014 Tank
419mm
(16-1/2)
356mm
(14)
C/L OF SEAT POST HOLES
140mm (5-1/2 CENTERS)
Nominal Dimensions:
721 x 479 x 873mm
(28-3/8" x 18-7/8" x 34-3/8")
To Be Specified:
❏ Color:
❏ White ❏ Bone ❏ Silver ❏ Linen ❏ Black
❏ Seat: (please specify color)
❏ Champion ® Slow Close Round Front #5330.010
❏ Rise & Shine Round Front #5322.011
❏ Laurel Round Front #5308.014
❏ Supply with stop:
873mm
(34-3/8)
SUPPLY
AS
REQ'D
83mm
(3-1/4)
Fixture only, seat and supply by others
Compliance Certifications Meets or Exceeds the Following Specifications:
• ASME A112.19.2M for Vitreous China Fixtures includes Flush Performance, Ball Pass Diameter,
Trap Seal Depth and all Dimensions
• Los Angeles Department of Water and Power
Supplementary Purchase Specification for
Non-Adjustability - July, 2003 revision
479mm
(18-7/8)
419mm
(16-1/2)
254mm
(10)
267mm
(10-1/2)
305mm
(12)
16mm
(5/8)
379mm
(14-7/8)
FOOT ON
BOTTOM
OF BOWL
152mm
(6)
FINISHED
FLOOR
284mm
(11-3/16)
C/L OF OUTLET
NOTES:
THIS TOILET IS DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION OF
305MM (12") FROM FINISHED WALL TO C/L OF OUTLET.
SUPPLY NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED
SEPARATELY.
* DIMENSION SHOWN FOR LOCATION OF SUPPLY IS SUGGESTED.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the
range of tolerances established by ANSI Standard A112.19.2.
These measurements are subject to change or cancellation. No responsibility
is assumed for use of superseded or voided pages.
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND
ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE
BUILDING FACILITIES-CHECK LOCAL CODES.
© 2008 AS America Inc.
K22
Revised 07/07