Download ADTRAN 600e User's Manual

Transcript
TSU 600 & 600e Systems
Preconfigured Plug-and-Play T1/FT1 Multiplexers for Voice or Data
Product Features
■
Pre-configured T1 multiplexers with factory
installed modules
■
Options for Nx data and
FXS, FXO and E&M voice
■
From 12 to 24 ports
per chassis
■
ADTRAN’s industryleading TSU 600 and
TSU 600e technologies
■
Embedded SNMP
management
■
TR-08 Mode 1 compliant
(unconcentrated)
■
Front panel, backlit LCD
■
Extensive network testing
and troubleshooting
■
T-Watch PRO™ and Telnet
support for local and
remote units
■
Industry-leading North
American five-year
warranty
Preconfigured TSU 600™ and TSU 600e™
systems offer the functionality of ADTRAN’s
fully featured T1 multiplexers in pre-installed
and pre-configured equipment packages.
These systems utilize the TSU 600 or TSU 600e
chassis packed with multiple expansion cards
for high volume voice and data applications.
Available packages represent the most
frequently requested configurations of the
TSU 600 and TSU 600e multiplexers, with
expansion cards to support 12 data ports,
or 24 FXO, FXS or E&M voice ports.
The TSU 600 and TSU 600e chassis have
six expansion slots that accommodate various
ADTRAN® expansion cards to support userspecific applications, including analog voice,
digital voice, DDS, Frame Relay, dial backup,
high-speed data and ISDN. Both units include
embedded SNMP functionality. The TSU 600e
adds an integrated 10Base-T interface to the
TSU 600 feature set, along with optional
support for internal, dual redundant power
supplies. Each hot-swappable power supply is
capable of supporting a fully loaded TSU 600e.
The flexibility of the TSU 600/600e multiplexer provides a clear migration path for
growing networks. Each chassis supports up
to 24 DTE interfaces. The user may combine
plug-in and plug-on modules in various
combinations. Single-port and dual-port
data modules support access to Frame Relay,
DDS or Basic Rate ISDN over T1 facilities.
Voice modules allow access to analog voice
circuits or a PBX. The TSU 600/600e supports
mixed-mode networks incorporating voice,
data and video.
The TSU 600/600e equipment packages
are factory-configured before shipping. For
ongoing configuration and management,
the TSU 600/600e and installed expansion
modules are fully SNMP compatible. The
TSU 600 communicates management information via a SLIP (EIA-232) port; while the
TSU 600e offers the convenience of a 10Base-T
port for direct connection to the LAN. Both
units include Telnet functionality and a front
panel LCD for anual configuration.
ADTRAN offers two network management
software programs to support configuration
and management of the TSU 600/600e Series.
T-Watch PRO™ is a Windows‚ 95 or NT‚
compatible program that facilitates easy
configuration and monitoring of all ADTRAN
host and remote devices. For HP OpenView
networks, ADTRAN offers ADVISION™, an
SNMP-based graphical user interface that
integrates seamlessly into a UNIX-based
enterprise-wide network management system.
TSU 600 & 600e Systems
General Information
800 9ADTRAN
[email protected]
www.adtran.com
Pre-Sales
Technical Support
800 615-1176 toll-free
[email protected]
www.adtran.com/support
Where to Buy
877 280-8416 toll-free
[email protected]
www.adtran.com/where2buy
Post-Sales
Technical Support
888 423-8726
[email protected]
www.adtran.com/support
ACES Installation &
Maintenance Service
888 874-ACES
[email protected]
www.adtran.com/support
International Inquiries
256 963 8000 voice
256 963-6300 fax
[email protected]
www.adtran.com/international
For the regional office
nearest you, visit:
CAUTION-RISK OF
ELECTRIC SHOCK
/CHAIN
OUT
Modules for a total of 24 voice ports. Includes
SNMP functionality. TR-08 compatible.
NN
JJ
DD
Z
V
R
L
B
F
J
T
X
D
N
NN
JJ
DD
Z
V
R
L
B
F
J
T
X
N
FF
D
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
TELECOMMUNICATION WIRING.
OUT MON
NETWORK
PORT X.3
IN
10 BASE T
E
P
Y
K
A
CC
HH
MM
U
S
C
M
H
W
EE
AA
KK
NN
JJ
DD
Z
V
R
L
B
F
J
T
X
N
FF
LL
BB
D
E
P
Y
K
A
CC
HH
MM
U
S
M
H
W
EE
KK
AA
C
PORT X.4
NN
JJ
DD
Z
V
L
F
B
R
T
X
N
FF
LL
BB
J
E
P
Y
K
A
CC
HH
B
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
O
F
F
O
F
F
O
N
O
N
PORT X.4
PORT X.2
DUAL
FXS
DUAL FXS
PORT X.1
PORT X.2
PORT X.4
MM
U
S
C
H
M
W
P
W
R
A
PORT X.3
PORT X.2
DUAL
FXS
PORT X.3
P
W
R
PORT X.2
DUAL
FXS
DUAL FXS
PORT X.1
PORT X.2
DUAL
FXS
PORT X.3
MODULE 5
MODULE 6
MODULE 4
PORT X.3
PORT X.2
DUAL FXS
PORT X.1
PORT X.2
EE
D
OUT
DUAL FXS
PORT X.1
PORT X.2
PORT X.4
DUAL FXS
PORT X.1
PORT X.2
MODULE 2
MODULE 3
MODULE 1
CONTROL
ALL EMPTY SLOTS MUST BE
COVERED WITH BLANK PANELS
PORT X.2
DUAL
FXS
CAUTION:
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
KK
NN
JJ
DD
Z
V
R
L
B
F
J
T
X
N
FF
LL
BB
D
E
P
Y
K
A
CC
HH
MM
U
S
H
M
W
EE
KK
C
CAUTION:
MAINTENANCE TO BE
PERFORMED BY TRAINED
SERVICE PERSONEL ONLY
IN
DUAL FXS
PORT X.1
PORT X.2
90-120 VAC
50/60 HZ.
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
Nx56/64 PORT X.2
AA
E
P
Y
K
A
CC
HH
MM
U
S
C
M
H
W
EE
AA
KK
NN
JJ
DD
Z
V
R
L
B
F
J
T
X
N
FF
LL
BB
D
E
P
Y
K
A
CC
HH
MM
U
S
C
M
H
W
EE
KK
AA
NN
JJ
Z
DD
R
V
X
FF
LL
BB
T
P
Y
CC
HH
MM
U
S
W
EE
AA
KK
NN
JJ
Z
DD
R
V
X
FF
LL
BB
T
P
Y
CC
HH
MM
U
S
W
EE
KK
AA
CAUTION-RISK OF
ELECTRIC SHOCK
Nx56/64 PORT X.2
Nx56/64 PORT X.1
V.35
AA
P
Y
CC
HH
MM
U
S
W
EE
KK
AA
E
K
A
C
H
M
L
B
F
J
N
D
E
K
A
C
H
M
L
B
F
J
N
D
E
K
A
C
H
M
E
P
Y
K
A
CC
HH
MM
U
S
C
M
H
W
EE
KK
NN
JJ
DD
Z
V
R
L
F
J
T
X
N
FF
LL
BB
D
E
P
Y
K
A
CC
HH
MM
U
S
C
M
H
W
EE
KK
NN
JJ
DD
Z
V
R
L
F
J
T
X
N
FF
LL
BB
D
E
P
Y
K
A
CC
HH
Nx56/64 PORT X.1
V.35
Nx56/64 PORT X.2
MM
U
S
C
H
M
W
B
Nx56/64 PORT X.1
V.35
V.35
Nx56/64 PORT X.2
/CHAIN
■ TSU 600e multiplexer with six Quad FXS Plus
O
Nx56/64 PORT X.2
FF
IN
Nx56/64 PORT X.1
NN
JJ
DD
Z
V
R
F
B
L
T
FF
X
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
I TELECOMMUNICATION WIRING.
CONTROL
LL
MODULE 6
BB
MODULE 4
MODULE 5
MODULE 3
LL
BB
NN
D
J
JJ
DD
Z
V
R
L
F
J
T
X
D
N
FF
LL
BB
B
TSU 600e VP24 FXS
V.35
AA
B
Nx56/64 PORT X.1
and six Nx56/64 Plug-On Modules for a total of 12
data ports. Includes SNMP functionality.
MODULE 1
MODULE 2
LL
NETWORK
Nx56/64 PORT X.2
5A/250V
V.35
AA
■ TSU 600 multiplexer with six Nx56/64 V.35 Modules
OUT MON
BB
IN
Nx56/64 PORT X.1
N
TSU 600 DP12 NX
EE
256 963-8000 voice
256 963-8699 fax
256 963-8200 fax back
Product Specifications
KK
P.O. Box 140000
Huntsville, AL 35814-4000
Preconfigured Plug-and-Play T1/FT1 Multiplexers for Voice or Data
AA
ADTRAN, Inc.
Attn: Enterprise Networks
901 Explorer Boulevard
Huntsville, AL 35806
PORT X.4
PORT X.2
90-120 VAC
50/60 HZ.
.7A MAX
DUAL
FXS
PORT X.3
90-120 VAC
50/60 HZ.
.7A MAX
PORT X.4
TSU 600 VP24 FXS
■ TSU 600 multiplexer with six Quad FXS Plus
CAUTION-RISK OF
ELECTRIC SHOCK
IN
Modules for a total of 24 voice ports. Includes
SNMP functionality. TR-08 compatible.
OUT MON
NETWORK
DUAL FXS
PORT X.1
PORT X.2
MODULE 1
MODULE 4
MODULE 2
MODULE 5
MODULE 3
MODULE 6
PORT X.2
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
I TELECOMMUNICATION WIRING.
CONTROL
/CHAIN
IN
OUT
DUAL FXS
PORT X.1
PORT X.2
DUAL
FXS
O
PORT X.2
DUAL
FXS
5A/250V
PORT X.3
PORT X.4
DUAL FXS
PORT X.1
PORT X.2
PORT X.3
PORT X.2
DUAL FXS
PORT X.1
PORT X.2
DUAL
FXS
PORT X.3
PORT X.4
PORT X.4
PORT X.2
90-120 VAC
50/60 HZ.
DUAL
FXS
PORT X.3
PORT X.4
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
DUAL FXS
PORT X.1
PORT X.2
PORT X.2
DUAL FXS
PORT X.1
PORT X.2
DUAL
FXS
PORT X.3
TSU 600 DC VP24 FXS
PORT X.4
PORT X.2
DUAL
FXS
PORT X.3
CAUTION:
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
PORT X.4
■ DC powered version of the TSU 600 multiplexer with
six Quad FXS Plus Modules for a total of 24 voice
ports. Includes SNMP functionality. TR-08 compatible.
CAUTION-RISK OF
ELECTRIC SHOCK
MODULE 1
IN
OUT MON
NETWORK
DUAL FXS
PORT X.1
PORT X.2
MODULE 5
MODULE 6
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
I TELECOMMUNICATION WIRING.
CONTROL
/CHAIN
IN
OUT
DUAL FXS
PORT X.1
PORT X.2
DUAL
FXS
PORT X.2
O
DUAL
FXS
5A/250V
PORT X.3
PORT X.4
DUAL FXS
PORT X.1
PORT X.2
PORT X.3
PORT X.2
PORT X.4
DUAL FXS
PORT X.1
PORT X.2
PORT X.2
DUAL
FXS
PORT X.3
PORT X.2
PORT X.4
[email protected]
-48V@1A
PORT X.4
DUAL FXS
PORT X.1
PORT X.2
DUAL
FXS
PORT X.3
PORT X.4
DUAL FXS
PORT X.1
PORT X.2
DUAL
FXS
PORT X.3
TSU 600e VP24 FXO
MODULE 4
MODULE 2
MODULE 3
PORT X.2
PORT X.2
+–
DUAL
FXS
PORT X.3
CAUTION:
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
PORT X.4
■ TSU 600e multiplexer with six Dual 2FXO Modules
and six Dual 2FXO Plug-Ons for a total of 24 voice
ports. Includes SNMP functionality.
CAUTION-RISK OF
ELECTRIC SHOCK
CAUTION:
MAINTENANCE TO BE
PERFORMED BY TRAINED
SERVICE PERSONEL ONLY
IN
OUT MON
DUAL FXO
PORT X.1
PORT X.2
NETWORK
DUAL FXO
PORT X.1
PORT X.2
PORT X.4
PORT X.3
PORT X.4
B
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
O
F
F
O
F
F
O
N
O
N
PORT X.4
PORT X.2
DUAL
FXO
PORT X.4
PORT X.2
90-120 VAC
50/60 HZ.
.7A MAX
DUAL
FXO
PORT X.3
90-120 VAC
50/60 HZ.
.7A MAX
PORT X.4
CAUTION-RISK OF
ELECTRIC SHOCK
MODULE 1
IN
■ TSU 600 multiplexer with six Dual E&M/TO Modules
P
W
R
A
PORT X.2
DUAL
FXO
DUAL FXO
PORT X.1
PORT X.2
PORT X.4
OUT MON
NETWORK
DUAL FXO
PORT X.1
PORT X.2
TSU 600 VP24 E&M
P
W
R
MODULE 4
PORT X.3
PORT X.2
six Dual 2FXO Plug-Ons for a total of 24 voice ports.
Includes SNMP functionality.
MODULE 5
MODULE 6
DUAL FXO
PORT X.1
PORT X.2
DUAL
FXO
PORT X.3
MODULE 2
PORT X.3
PORT X.2
DUAL FXO
PORT X.1
PORT X.2
OUT
DUAL FXO
PORT X.1
PORT X.2
DUAL
FXO
■ TSU 600 multiplexer with six Dual 2FXO Modules and
IN
10 BASE T
DUAL
FXO
PORT X.3
TSU 600 VP24 FXO
ALL EMPTY SLOTS MUST BE
COVERED WITH BLANK PANELS
PORT X.2
MODULE 3
MODULE 1
CONTROL
/CHAIN
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
TELECOMMUNICATION WIRING.
MODULE 4
MODULE 2
MODULE 5
MODULE 3
MODULE 6
PORT X.2
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
I TELECOMMUNICATION WIRING.
CONTROL
/CHAIN
IN
OUT
DUAL FXO
PORT X.1
PORT X.2
DUAL
FXO
PORT X.2
O
DUAL
FXO
5A/250V
PORT X.3
PORT X.4
DUAL FXO
PORT X.1
PORT X.2
PORT X.3
PORT X.2
DUAL FXO
PORT X.1
PORT X.2
DUAL
FXO
PORT X.3
PORT X.4
PORT X.4
PORT X.2
90-120 VAC
50/60 HZ.
DUAL
FXO
PORT X.3
PORT X.4
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
DUAL FXO
PORT X.1
PORT X.2
PORT X.2
and six Dual E&M/TO Plug-Ons for a total of 24 E&M
ports. 2713 Hz loopback detection.
Includes SNMP functionality.
DUAL FXO
PORT X.1
PORT X.2
DUAL
FXO
PORT X.3
PORT X.4
PORT X.2
DUAL
FXO
PORT X.3
CAUTION:
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
PORT X.4
CAUTION-RISK OF
ELECTRIC SHOCK
IN
OUT MON
NETWORK
DUAL E&M
PORT X.1
PORT X.2
www.adtran.com/regional
MODULE 1
MODULE 4
MODULE 2
MODULE 5
MODULE 3
MODULE 6
PORT X.2
DUAL
E&M
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
I TELECOMMUNICATION WIRING.
CONTROL
/CHAIN
IN
OUT
DUAL E&M
PORT X.1
PORT X.2
PORT X.2
O
DUAL
E&M
5A/250V
PORT X.3
DUAL E&M
PORT X.1
PORT X.2
PORT X.4
PORT X.2
DUAL
E&M
PORT X.3
PORT X.3
DUAL E&M
PORT X.1
PORT X.2
PORT X.4
PORT X.4
PORT X.2
90-120 VAC
50/60 HZ.
DUAL
E&M
PORT X.3
PORT X.4
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
DUAL E&M
PORT X.1
PORT X.2
PORT X.2
DUAL
E&M
PORT X.3
For more detailed specifications on the TSU 600 or 600e
multiplexers or the voice and data expansion cards
included in the Preconfigured TSU 600 Systems, please
call 800 9ADTRAN and request a copy of the TSU 600 &
600e data sheet (document number 61202076L1-8B), the
Nx56/64 Solutions data sheet (document number
61202054L1-8B), or the Analog Voice Modules data
sheet (document number 61200080L1#HS-8A).
ADTRAN is a ISO 9001:2000
certified supplier.
PORT X.4
Equipment
Specifications subject to change without notice. ADVISION, T-Watch PRO, TSU 600
and TSU 600e are trademarks of ADTRAN, Inc. ADTRAN is a registered trademark
of ADTRAN, Inc. All other registered trademarks and trademarks mentioned in this
publication are the property of their respective owners.
PORT X.4
CAUTION:
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
Part #
TSU 600
1202076L2
TSU 600e
1202076L1
TSU 600 DP12 Nx
4200076L2
TSU 600e VP24 FXS
4202076L1
TSU 600 VP24 FXS
4200076L1
TSU 600e VP24 FXO
Printed in the U.S.A.
64200076LX-8D February 2004
Copyright©2004 ADTRAN, Inc.
All rights reserved.
PORT X.2
DUAL
E&M
PORT X.3
Ordering Information
TSU 600 DC VP24 FXS
ADTRAN is a TL 9000 3.0
certified supplier.
DUAL E&M
PORT X.1
PORT X.2
4200076L1#DC
4202076L3
TSU 600 VP24 FXO
4200076L3
TSU 600 VP24 E&M
4200076L5