Download Black Box SYH6K6RMT-P1
Transcript
© 2005. All rights reserved. Black Box Corporation. Black Box Corporation • 1000 Park Drive • Lawrence, PA 15055-1018 • Tech Support: 724-746-5500 • www.blackbox.com • e-mail: [email protected] SYMMETRA RM Bringing all the time-tested advantages of Symmetra to your rack. Key Features The first rackmount enterprise-level power protector with redundancy! Flexible range of capacity and runtimes. Integrated Web/SNMP management features. Easy-to-manage, menubased diagnostics. Occupies 8 or 10U of rack space. Built-in automatic and manual bypass feature. NEMA L6-30 plug makes installation easy in 208-VAC environments. ith more servers, storage products, and other missioncritical networking equipment becoming rack-based, there’s a growing need for innovative rackmounted power protectors. The Symmetra RM provides 2-, 4-, or 6-kVA power increments that provide N+1 redundancy in just 8 or 10U of rack space. Like the Symmetra, the Symmetra RM lets multiple power modules share the power array’s connected load. All modules run in parallel and share the load evenly. If a module fails or is removed, there’s nothing to worry about: The Symmetra has one more module than is necessary for full-load operation. So you’re still functioning at full power. This load-sharing is what’s known as N+1 redundancy. It ensures maximum uptime and continuous availability. The W Symmetra RM is the first rackmount enterprise-level power protector to offer redundancy. And you won’t experience any downtime when you upgrade your Symmetra RM: hot-swappable components keep your network up and running. To set up your Symmetra system, choose the Symmetra model that you need based on your current VA load and future expansion needs. All Symmetra RM units are available with 208VAC output. Three units also feature a stepdown transformer that converts 208-VAC output into 120-VAC output. This conversion enables you to power the data center or rack enclosure from a single high-powered circuit while providing UPS-protected 120 VAC to each piece of equipment. Add an additional power module for N+1 redundancy. Choose additional battery modules for longer run times if needed; these hot-swappable modules fit into any vacant slot in the Symmetra RM. To expand your power capacity, add more power modules in increments of 2 kVA, up to a maximum of 6 kVA per Symmetra RM unit. If there’s an extended power outage, included PowerChute Network Shutdown software helps you save data and shut down multiple servers over the network. In addition, units with up to 6 kVA are optimized for eight minutes, allowing you to perform orderly shutdowns. And with Symmetra’s menubased remote display, power and UPS information is always available at the touch of a button. You can monitor parameters such (continued on page 2) 1 11/30/2000 #25041 Specifications Input Conformance Nominal Voltage: 208 or 240 VAC Approvals: FCC, CSA, UL 1778 Output Frequency: 50/60 Hz ±5 Hz (autosensing); SYH2K6RMT-P1: 60 Hz ±3 Hz Environmental Capacity: SYH2K6RMT: 2 kVA/1.4 kW; SYH4K6RMT: 4 kVA/2.8 kW; SYH6K6RMT: 6 kVA/4.2 kW; SYH2K6RMT-P1: 2 kVA/1.4 kW; SYH4K6RMT-P1: 4 kVA/2.8 kW; SYH6K6RMT-P1: 6 kVA/4.2 kW Voltage: SYH2K6RMT, SYH4K6RMT, SYH6K6RMT: 208 VAC (240-VAC configurable); SYH2K6RMT-P1, SYH4K6RMT-P1, SYH6K6RMTP1: 208 VAC↔120 VAC (240-VAC configurable) Max. Configurable Power with Additional Power Modules: SYH2K6RMT, SYH4K6RMT, SYH6K6RMT: 6 kVA/4.2 kW; SYH2K6RMT-P1, SYH4K6RMTP1, SYH6K6RMT-P1: 6 kVA/ 4.2 kW (max. 5 kVA of 120 VAC) Connections (Always check with local electrical requirement and regulations): SYH2K6RMT, SYH4K6RMT, SYH6K6RMT: (2) NEMA L6-20R, (1) NEMA L630R; SYH2K6RMT-P1, SYH4K6RMT-P1, SYH6K6RMTP1: (2) NEMA L6-20R, (12) NEMA 5-15R Efficiency at Full Load: SYH2K6RMT, SYH4K6RMT, SYH6K6RMT: 91%; SYH2K6RMTP1, SYH4K6RMT-P1, SYH6K6RMT-P1: 86% Bypass: Internal bypass (automatic and manual) Voltage Distortion: <5% at full load Frequency (Sync): 57–63 Hz Frequency (Not Sync): 60 Hz Connection (Always check with local electrical requirements and regulations): (1) NEMA L6-30P Voltage Range: 155–276 V Power Factor: 0.98 Cord Length: 6 feet (1.8 m) Batteries Battery Type: Maintenance-free, sealed lead-acid battery with suspended electrolyte; leakproof Typical Recharge Time (Recharge time to 90 after full discharge): 4 hours Replacement Battery Module: SYH2K6RMT, SYH2K6RMT-P1: (1) SYBT2; SYH4K6RMT, SYH4K6RMT-P1: (2) SYBT2; SYH6K6RMT, SYH6K6RMT-P1: (3) SYBT2 Physical ® Operating Temperature: 32 to 104°F (0 to 40°C) Operating Relative Humidity: Up to 95% Operating Elevation: Up to 10,000 feet (3048 m) Storage Temperature: 5 to 113°F (-15 to +45°C) Storage Relative Humidity: Up to 95% Storage Elevation: Up to 50,000 feet (15,240 m) Audible Noise at 3 ft. (0.9 m): 60 dBA On-Line Thermal Dissipation: SYH2K6RMT: 430 BTU/hr.; SYH4K6RMT: 860 BTU/hr.; SYH6K6RMT: 1290 BTU/hr.; SYH2K6RMT-P1: 590 BTU/hr.; SYH4K6RMT-P1: 1542 BTU/hr.; SYH6K6RMT-P1: 2143 BTU/hr. Size: SYH2K6RMT, SYH4K6RMT, SYH6K6RMT: 14"H (8U) x 19"W x 28.75"D (35.6 x 48.3 x 73 cm); SYH2K6RMT-P1, SYH4K6RMTP1, SYH6K6RMT-P1: 17.5"H (10U) x 19"W x 28.75"D (44.5 x 48.3 x 73 cm) Weight: SYH2K6RMT: 164 lb. (74.4 kg); SYH4K6RMT: 229 lb. (103.9 kg); SYH6K6RMT: 294 lb. (133.4 kg); SYH2K6RMT-P1: 259 (117.5 kg); SYH4K6RMT-P1: 324 lb. (147 kg); SYH6K6RMT-P1: 389 (176.5 kg) Shipping Weight: SYH2K6RMT: 185 lb. (83.9 kg); SYH4K6RMT: 256 lb. (116.1 kg); SYH6K6RMT: 327 lb. (148.3 kg); SYH2K6RMTP1: 295 lb. (133.8 kg); SYH4K6RMT-P1: 366 lb. (166 kg); SYH6K6RMT-P1: 437 lb. (198.2 kg) Communications/ Management Interface Port: (1) DB9 RS-232, (1) RJ-45 10BASE-T Ethernet for Web, (2) SmartSlot™ Control Panel: Multi-function LCD status and control console Management Software: PowerChute Network Shutdown, Web/SNMP Management Card included with each unit ® Audible Alarm: Distinctive lowbattery alarm Emergency Power Off (EPO): Yes Crest Factor: Up to 5:1 What the package includes • • • • • 2 (1) Symmetra RM Rackmounting brackets Rackmounting support rails CD with software Users’ manual (continued from page 1) as input voltage, temperature, level of redundancy, and humidity. The power-factor correction feature also eliminates power-line harmonics and neutral overloads that can cause building wiring to overheat. Symmetra RM also performs self-diagnosis. In the event of an internal failure, the unit sends you an alert via network, SNMP, or Web-based commands. Because of Symmetra RM’s redundancy, the system remains up, running, and protected during repairs. 3000 1950 — 12 min. 25 min. — 13 min. 26 min. 2500 1625 — 17 min. 34 min. — 18 min. 34 min. 2200 1430 — 22 min. 40 min. — 22 min. 41 min. 1600 1040 11 min. 35 min. 59 min. 11 min. 36 min. 1 hr. 900 585 29 min. 1 hr., 10 min. 1 hr., 46 min. 30 min. 1 hr., 13 min. 1 hr., 50 min. VA Watts SYH2K6RMT-P1 SYH4K6RMT-P1 SYH6K6RMT-P1 SYH2K6RMT SYH4K6RMT SYH6K6RMT 1000 650 24 min. 1 hr., 2 min. 1 hr., 36 min. 25 min. 1 hr., 5 min. 1 hr., 39 min. 1200 780 18 min. 51 min. 1 hr., 21 min. 19 min. 52 min. 1 hr., 23 min. 1400 910 14 min. 42 min. 1 hr., 9 min. 14 min. 43 min. 1 hr., 10 min. 2000 1300 7 min. 25 min. 45 min. 7 min. 26 min. 46 min. 34 min. 1 hr., 19 min. 1 hr., 57 min. 35 min. 1 hr., 22 min. 2 hr., 2 min. 40 min. 1 hr., 29 min. 2 hr., 11 min. 42 min. 1 hr., 34 min. 2 hr., 16 min. 48 min. 1 hr., 43 min. 2 hr., 27 min. 51 min. 1 hr., 48 min. 2 hr., 34 min. 59 min. 2 hr. 2 hr., 46 min. 1 hr., 3 min. 2 hr., 7 min. 2 hr., 55 min. 1 hr., 13 min. 2 hr., 21 min. 3 hr., 11 min. 1 hr., 20 min. 2 hr., 31 min. 3 hr., 23 min. 1 hr., 35 min. 2 hr., 50 min. 3 hr., 43 min. 1 hr., 45 min. 3 hr., 5 min. 3 hr., 59 min. 3 hr., 49 min. 5 hr., 18 min 6 hr., 5 min. 4 hr., 45 min. 6 hr., 8 min. 6 hr., 47 min. SYH2K6RMT-P1 SYH4K6RMT-P1 SYH6K6RMT-P1 SYH2K6RMT SYH4K6RMT SYH6K6RMT 3 hr., 3 min. 4 hr., 34 min. 5 hr., 25 min. 3 hr., 38 min. 5 hr., 10 min. 5 hr., 58 min. 2 hr., 7 min. 3 hr., 31 min. 4 hr., 26 min. 2 hr., 24 min. 3 hr., 53 min. 4 hr., 48 min. 400 260 50 33 VA Watts 100 65 200 130 300 195 500 325 600 390 700 455 800 520 Runtime by Load for Symmetra RM 3 Why Buy From Black Box? Exceptional Value. Exceptional Tech Support. Period. Recognize any of these situations? • You wait more than 30 minutes to get through to a vendor’s tech support. • The so-called “tech” can’t help you or gives you the wrong answer. • You don’t have a purchase order number and the tech refuses to help you. • It’s 9 p. m. and you need help, but your vendor’s tech support line is closed. According to a survey by Data Communications magazine, 90% of network managers surveyed say that getting the technical support they need is extremely important when choosing a vendor. But even though network managers pay anywhere from 10 to 20% of their overall purchase price for a basic service and support contract, the technical support and service they receive falls far short of their expectations—and certainly isn’t worth what they paid. At Black Box, we guarantee the best value and the best support. You can even consult our Technical Support Experts before you buy if you need help selecting just the right component for your application. Don’t waste time and money—call Black Box today. Ordering Information ITEM CODE Symmetra RM 208-VAC Output 2 kVA (Expandable to 6 kVA) ...................SYH2K6RMT 4 kVA (Expandable to 6 kVA) ...................SYH4K6RMT 6 kVA .............................................................SYH6K6RMT 208-VAC Output with 120-Volt Transformer 2 kVA (Expandable to 6 kVA) .............SYH2K6RMT-P1 4 kVA (Expandable to 6 kVA) .............SYH4K6RMT-P1 6 kVA .......................................................SYH6K6RMT-P1 Add optional Power Modules for N+1 redundancy… 2-kVA Power Module ........................................SYPM2KU Choose single Battery Modules for longer run times (if needed)… Battery Module..........................................................SYBT2