Download Intel Xeon Phi 7120A

Transcript
Figure 3-7
Airflow Requirement vs. Inlet Temperature for the 31S1P at 270W TDP and
SE10P/7120P/3120P at 300W TDP
o
Card Inlet ( C)
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
Total Flow (ft^3/min)
Primary (ft^3/min)
Secondary (ft^3/min)
Card dP (inH2 O)
14.4
14.7
15
15.3
15.6
16
16.3
16.7
17.1
17.6
18
18.5
19.1
19.7
20.3
21
21.7
22.5
23.3
24.3
25.3
26.5
27.8
29.2
30.9
32.8
10.5
10.8
11.1
11.3
11.7
12
12.3
12.7
13
13.4
13.8
14.3
14.8
15.3
15.8
16.4
17
17.6
18.4
19.1
20
20.9
21.9
23
24.2
25.6
3.9
3.9
3.9
3.9
4
4
4
4.1
4.1
4.1
4.2
4.3
4.3
4.4
4.5
4.6
4.7
4.8
5
5.1
5.3
5.6
5.9
6.2
6.7
7.2
0.13
0.13
0.14
0.14
0.15
0.15
0.16
0.16
0.17
0.18
0.19
0.2
0.21
0.22
0.23
0.24
0.26
0.27
0.29
0.31
0.34
0.37
0.4
0.44
0.48
0.54
Intel® Xeon Phi™ Coprocessor Datasheet
24
Document ID Number: 328209 003EN