Download Super Talent Technology 1TB RaidDriver II

Transcript
RAIDDrive II PCIe SSD Datasheet
SUPERTALENT RAIDDRIVE II
PCI EXPRESS SOLID STATE DRIVE
Copyright ©, Property of Super Talent Technology. All rights reserved. The information and
specification provided in this document should be used for comparative analysis and
reference purposes. The contents of this document are subject to change without prior
notice.
Rev 1.0 July 2011
Page 1
RAIDDrive II PCIe SSD Datasheet
TABLE OF CONTENTS
Table of Figures ............................................................................................................................... 3
Table of Tables ................................................................................................................................ 4
1.0 product description................................................................................................................... 4
1.1 Product Overview ................................................................................................................. 5
1.2 Target Applications ............................................................................................................... 5
1.3 Product Features ................................................................................................................... 5
2.0 raiddriver architecture .............................................................................................................. 5
2.1 raiddrive architecture ........................................................................................................... 6
2.2 RAID Features........................................................................................................................ 6
2.3 Monitors and Indicators........................................................................................................ 6
2.4 Operating System Support .................................................................................................... 6
3.0 Product Ordering Part Numbers ............................................................................................... 6
3.1 Ordering Part Structure ........................................................................................................ 7
3.2 Valid Ordering Part Numbers ................................................................................................ 7
4.0 Physical Specifications .............................................................................................................. 8
4.1 RAIDDRIVE II board ............................................................................................................... 8
4.2 Dimension ............................................................................................................................. 9
5.0 performance Specifications .................................................................................................... 10
5.1 Performance Test System Configurations .......................................................................... 10
5.2 Benchmarking Software ...................................................................................................... 10
5.3 detail performace test results............................................................................................. 11
5.3.1 atto disk benchmark 2.34 ............................................................................................ 11
Rev 1.0 July 2011
Page 2
RAIDDrive II PCIe SSD Datasheet
5.3.2 pc mark vantage........................................................................................................... 12
5.3.3 crystal disk mark 2.2 .................................................................................................... 13
5.3.4 hd tune pro ............................................................................................................ 13~15
5.3.5 AS SSD Benchmark 1.3.3626 ........................................................................................ 16
5.3.6 IO Meter 2008. 16. 18 RC2........................................................................................... 18
6.0 Electrical Specifications........................................................................................................... 19
6.1 Power supply requirements ................................................................................................ 19
7.0 Environmental Specifications ................................................................................................. 19
8.0 Quality and Reliability Specifications ...................................................................................... 19
9.0 Compliance Specifications ...................................................................................................... 19
10.0 Pin Descriptions .................................................................................................................... 19
10.1 RAIDDrive pcie Pin Assignments ................................................................................. 19~20
11.0 Installation ............................................................................................................................ 21
For More Information ................................................................................................................... 23
Change Record .............................................................................................................................. 23
TABLE OF FIGURES
Figure 1: RAIDDrive PCIe Mother Board Outline Drawing ............... Error! Bookmark not defined.
Figure 2: ATTO Disk Benchmark Scores ........................................................................................ 11
Figure 3: PC Mark Vantage Scores ................................................................................................ 12
Figure 4: Crystal DiskMark Scores ................................................................................................. 13
Figure 5: HD Tune Scores ....................................................................................................... 13~15
Figure 6: AS SSD Benchmark Scores............................................................................................. 16
Rev 1.0 July 2011
Page 3
RAIDDrive II PCIe SSD Datasheet
Figure 7: IO Meter Scores ............................................................................................................ 18
TABLE OF TABLES
Table 1: Ordering Part Structure..................................................................................................... 7
Table 2: Valid Ordering Part Numbers and Descriptions ................................................................ 7
Table 3: Data Pin Signal Assignment ....................................................................................... 19~20
Table 4: Change Record ................................................................................................................ 23
1.0 PRODUCT DESCRIPTION
Rev 1.0 July 2011
Page 4
RAIDDrive II PCIe SSD Datasheet
1.1 PRODUCT OVERVIEW
RAIDDrive II is designed to break the throughput bottleneck in the storage subsystem by
removing the bandwidth limitation of the SATA bus. The PCIe (Gen.2) x8 interface used by
RAIDDrive II supports 4GB/sec bandwidth, more than 10 times that of the SATA-II 3Gbps bus,
and 5 times greater than the SATA-III bus.
Using the latest NAND flash memory and up-to-date RAID controller, RAIDDrive II is able to
support Max. Read speeds of up to 2.4GB/sec. A turbocharged cache system with up to 1GB of
DRAM cache enables Max. Write speeds as fast as 2.8GB/sec. RAIDDrive II, which houses eight
discrete SATA SSDs, comes in a custom formfactor measuring 231.5 x 94 x 20.6 mm.
This small formfactor now can be fitted into the 1U/2U/3U storage server with the RISER card,
which is one of the great advantages over the previous generation RAIDDrive I.
1.2 TARGET APPLICATIONS






Audio/Video Streaming Server Cache storage
Data Center Server Cache storage
Web server Cache storage
Supercomputing
Near-line backup
Security systems
1.3 PRODUCT FEATURES








PCIe Gen.2 x8 lane host interface
Max Speed: Read 2.4GB/s, Write 2.8GB/s
Capacities up to 2TB
MLC NAND Flash
Minimum 10 year data retention
Built in wear leveling algorithm and error detection and correction
100% tested HW and SW
Designed and Manufactured in USA
2.0 RAIDDRIVER ARCHITECTURE
Rev 1.0 July 2011
Page 5
RAIDDrive II PCIe SSD Datasheet
2.1 RAIDDRIVE ARCHITECTURE






LSI 2108 ROC Processor for RAID core and SAS microcode
1GB On-board DDR2 SDRAM cache with ECC protection
Write back cache support
Supports up to 2TB capacity
NVRAM for RAID configuration & transaction log
Redundant flash image for adapter availability
2.2 RAID FEATURES



User configurable RAID level 0 or 5.
Instant Availability and background initialization
Field-upgradeable firmware in flash ROM
2.3 MONITORS AND INDICATORS




System status indication through global HDD activity/fault connector, alarm buzzer
SMTP support for email notification
SNMP support for remote manager
Enclosure management (SES2, SMP and SGPIO) ready
2.4 OPERATING SYSTEM SUPPORT







Windows® 2000/XP/Server2003/Vista/Win7/2008
Linux
VMWare
Mac OS X 10.x (EFI Bios Support)
FreeBSD
Solaris® 10 x86/x86_64
Others. (Contact SuperTalent Sales)
3.0 PRODUCT ORDERING PART NUMBERS
Rev 1.0 July 2011
Page 6
RAIDDrive II PCIe SSD Datasheet
3.1 ORDERING PART STRUCTURE
RAIDDrive II is available in capacities up to 2TB, in RAID 0 or RAID 5 configurations with MLC
NAND flash. (For SLC solution, please contact our Sales) Table 1 shows currently available part
numbers and their specifics
Prefix
R2S
RAID Level
X
Density
XXX
Version Number
X
STT RAIDDrive II
0-RAID 0
5-RAID 5
480-480GB
1T-1TB
1-Version 1 (Now)
2-Version 2 (for Future use)
2T-2TB
Table 1: Ordering Part Structure
3.2 VALID ORDERING PART NUMBERS
Part Number
Capacity
RAID Level
# of Enclosure
Media Storage
R2S0(5)4801
480GB (420GB)
0 (5)
8
MLC
R2S0(5)1T1
1TB (840GB)
0 (5)
8
MLC
R2S0(5)2T1
2TB (1.6TB)
0 (5)
8
MLC
Table 2: Valid Ordering Part Numbers and Descriptions. (*Capacity may differ from User capacity when it is formatted)
Rev 1.0 July 2011
Page 7
RAIDDrive II PCIe SSD Datasheet
4.0 PHYSICAL SPECIFICATIONS
4.1 RAIDDRIVE II BOARD
View from the Right hand side
Rev 1.0 July 2011
Page 8
RAIDDrive II PCIe SSD Datasheet
View from the Bottom
View from the Top
4.2 DIMENSION
RAIDDrive II: 231.5 x 94 x 20.6 mm
Rev 1.0 July 2011
Page 9
RAIDDrive II PCIe SSD Datasheet
5.0 PERFORMANCE SPECIFICATIONS (EXAMPLE – 1TB RAIDDRIVE II)
Interface: PCIe (Generation 2) x8
Access Time: 0.1 ms
Max. Speed: READ-2.4GB/sec, WRITE-2.8GB/sec
5.1 PERFORMANCE TEST SYSTEM CONFIGURATIONS
The following Performance Benchmark is showing the most popular configuration of the
RAIDDRIVE II. It is 1TB storage and its part number is R2S01T1.
Test Platform
1. Mother Board:
ASUS P6X58D PREMIUM
2. CPU:
Intel i7 975 @3.33GHz
3. Memory:
DDR3 2000 6GB (3 channel)
4. OS:
Windows 7 ULTIMATE 64bit
5. OS DRIVE:
SuperTalent ULTRA SSD MT 240GB
6. North Bridge:
INTEL X58
7. South Bridge:
INTEL ICH10R
8. Bios SATA Mode:
AHCI
5.2 BENCHMARKING SOFTWARE






ATTO Disk Benchmark 2.34
PC Mark Vantage Pro 64-bit
Crystal Disk Mark 3.0
HD Tune Pro 3.50
AS SSD Benchmark 1.3.3626
IO Meter 2008.16.18-RC2
Rev 1.0 July 2011
Page 10
RAIDDrive II PCIe SSD Datasheet
5.3 DETAIL PERFORMACE TEST RESULTS
5.3.1 ATTO DISK BENCHMARK 2.46
The following screenshot show the ATTO disk benchmark with the Queue Depth of 10.
This ATTO test only shows the Sequential READ/WRITE speed.
Figure 1: ATTO Disk Benchmark Scores
Rev 1.0 July 2011
Page 11
RAIDDrive II PCIe SSD Datasheet
5.3.2 PC MARK VANTAGE
The RAIDDrive posted excellent scores in Media Center, but relatively slow scores in other
applications because they are mostly using small file application except Video Editing.
Figure 2: PC Mark Vantage Scores
Rev 1.0 July 2011
Page 12
RAIDDrive II PCIe SSD Datasheet
5.3.3 CRYSTAL DISK MARK 3.0
In Crystal DiskMark tested for five loops with 4000MB, 1000MB and 100MB data sizes.
Figure 3: Crystal DiskMark Scores
Rev 1.0 July 2011
Page 13
RAIDDrive II PCIe SSD Datasheet
5.3.4 HD TUNE PRO 3.50
HD TUNE showed average read speeds of around 1,600MB/sec and average write speeds of
around 2,000MB/sec, This HD TUNE benchmark shows Sequential speed and the next page
shows the random access on READ and WRITE.
Rev 1.0 July 2011
Page 14
RAIDDrive II PCIe SSD Datasheet
Rev 1.0 July 2011
Page 15
RAIDDrive II PCIe SSD Datasheet
Figure 4: HD TUNE PRO 3.50 Scores
Rev 1.0 July 2011
Page 16
RAIDDrive II PCIe SSD Datasheet
5.3.5 AS SSD BENCHMARK 1.3.3626
The AS SSD Benchmark is almost same as the mix of Crystal DiskMark and PC Mark Vantage.
Figure 5: AS SSD Scores
Rev 1.0 July 2011
Page 17
RAIDDrive II PCIe SSD Datasheet
5.3.6 IO METER
IO Meter tests the RAIDDrive’s transaction speed in I/O operations per second. We ran this test
with queue depth settings of 1 ~ 64. The larger queue depth tended to offer the highest
transaction speeds. We specially ran this program for 50 minutes per each thread at the Steady
State SSD status.
Test SPEC
IOps
MBps
128KB-RR
128KB-RW
128KB-SR
128KB-SW
4KB-RR
4KB-RW
4KB-SR
4KB-SW
64KB-RW
8KB-RW
Database
File Server
Web Server
Workstation
QD=1
10,642
10,250
11,095
10,261
35,013
33,034
28,179
33,177
15,723
29,850
29,939
28,625
28,904
31,026
QD=2
17,300
19,828
19,789
20,374
85,603
87,279
49,262
88,179
31,215
80,812
61,591
52,355
54,919
67,221
QD=4
17,400
20,745
19,836
22,419
132,609
119,161
54,956
116,929
41,614
109,962
78,587
68,413
74,057
87,045
QD=8
17,406
20,758
19,913
22,460
132,717
117,774
57,297
115,972
41,721
110,233
82,650
80,922
90,284
93,647
QD=16
17,364
20,738
19,918
22,464
132,673
118,205
58,461
116,824
41,692
110,441
90,408
88,613
100,279
102,770
QD=32
17,272
20,579
19,919
22,467
132,880
117,944
64,528
116,204
41,408
109,921
95,186
78,802
103,360
93,758
QD=64
17,267
20,571
19,922
22,467
126,301
118,375
61,957
118,692
41,382
110,523
82,988
76,357
87,376
88,203
QD=1
1,330
1,281
1,387
1,283
137
129
110
130
983
233
234
310
442
242
QD=2
2,162
2,479
2,474
2,547
334
341
192
344
1,951
631
481
566
840
525
QD=4
2,175
2,593
2,479
2,802
518
465
215
457
2,601
859
614
740
1,133
680
QD=8
2,176
2,595
2,489
2,808
518
460
224
453
2,608
861
646
876
1,381
732
QD=16
2,170
2,592
2,490
2,808
518
462
228
456
2,606
863
706
959
1,534
803
QD=32
2,159
2,572
2,490
2,808
519
461
252
454
2,588
859
744
853
1,581
732
QD=64
2,158
2,571
2,490
2,808
493
462
242
464
2,586
863
648
826
1,336
689
64KB Stream Read
64KB Stream Write
128KB Stream Read
128KB Stream Write
256KB Stream Read
256KB Stream Write
512KB Stream Read
512KB Stream Write
17,134
15,904
11,049
10,288
6,373
6,114
3,466
3,404
33,458
32,059
19,802
20,471
10,017
11,401
4,556
5,190
39,126
45,029
19,857
22,440
10,037
11,462
4,559
5,198
39,120
45,136
19,930
22,486
10,041
11,463
4,563
5,199
39,155
45,096
19,935
22,495
10,042
11,465
4,557
5,174
39,148
45,108
19,938
22,503
10,043
11,463
4,556
5,174
39,146
45,121
19,929
22,500
10,044
11,465
4,556
5,173
1,071
994
1,381
1,286
1,593
1,528
1,733
1,702
2,091
2,004
2,475
2,559
2,504
2,850
2,278
2,595
2,445
2,814
2,482
2,805
2,509
2,865
2,280
2,599
2,445
2,821
2,491
2,811
2,510
2,866
2,282
2,599
2,447
2,819
2,492
2,812
2,511
2,866
2,278
2,587
2,447
2,819
2,492
2,813
2,511
2,866
2,278
2,587
2,447
2,820
2,491
2,813
2,511
2,866
2,278
2,587
Figure 6: IO Meter Scores
Rev 1.0 July 2011
Page 18
RAIDDrive II PCIe SSD Datasheet
6.0 ELECTRICAL SPECIFICATIONS
6.1 POWER SUPPLY REQUIREMENTS
Power Rail
+3.3V
+12V
Voltage Tolerance
Max +/-9%
Max +/-8%
+3.3Vaux
Max +/-9%
Supply Current
Max 3.0A
Max 2.1A
Wakeup Enabled-Max 375mA
Non-wakeup Enabled-Max 20mA
Capacitive Load
Max 1000µF
Max 1000µF
Max 150µF
7.0 ENVIRONMENTAL SPECIFICATIONS
Operating Temperature: Commercial Temp Range Only

Commercial +0°C to +70°C
Storage Temperature: -40°C to +70°C
Humidity: 5% to ~ 90% RH
8.0 QUALITY AND RELIABILITY SPECIFICATIONS
Data Retention: Maximum of 10 years
Wear Leveling: Dynamic and static wear-leveling
Bad Block Management: Drive will self identify bad blocks and remap physical to logical
addresses to avoid bad blocks.
ECC/EDC (Error Correction Code/Error Detection Code): Built in error detection and correction
will correct physical bit errors in NAND.
MTBF: >1,500,000 hours
Power Cycle: TBD
9.0 COMPLIANCE SPECIFICATIONS
All RAIDDrive II are compliant with the following standards and regulations:

RoHS
Rev 1.0 July 2011
Page 19
RAIDDrive II PCIe SSD Datasheet
10.0 PIN DESCRIPTIONS
10.1 RAIDDRIVE PCIE PIN ASSIGNMENTS
Pin
Side B
Name
Side A
Description
Name
Description
1
+12V
12V Power
PRSNT1#
Hot-Plug presence detect
2
+12V
12V Power
+12V
12V Power
3
RSVD
Reserved
+12V
12V Power
4
GND
Ground
GND
Ground
5
SMCLK
JTAG2
TCK (Test Clock), clock input for
JTAG interface
6
SMDAT
JTAG3
TDI (Test Data Input)
7
GND
Ground
JTAG4
TDO (Test Data Output)
8
+3.3V
3.3V Power
JTAG5
TMS (Test Mode Select)
9
JTAG1
TRST# (Test Reset) resets the JTAG
interface
+3.3V
3.3V power
10
3.3Vaux
3.3V auxiliary power
+3.3V
3.3V power
11
WAKE#
Signal for Link reactivation
PERST#
Fundamental reset
SMBus (System Management Bus)
Clock
SMBus (System Management Bus)
Data
Mechanical Key
12
RSVD
Reserved
GND
Ground
13
GND
Ground
REFCLK+
14
PETp0
REFCLK-
15
PETn0
Transmitter differential pair,
Lane 0
Reference clock
(differential pair)
GND
Ground
16
GND
Ground
PERp0
17
PRSNT2#
Hot-Plug presence detect
PERn0
Receiver differential pair,
Lane 0
18
GND
Ground
GND
Ground
End of the x1 connector
19
PETp1
RSVD
Reserved
PETn1
Transmitter differential pair,
Lane 1
20
GND
Ground
21
GND
Ground
PERp1
22
GND
Ground
PERn1
Receiver differential pair,
Lane 1
23
PETp2
GND
Ground
24
PETn2
Transmitter differential pair,
Lane 2
GND
Ground
25
GND
Ground
PERp2
Receiver differential pair,
Rev 1.0 July 2011
Page 20
RAIDDrive II PCIe SSD Datasheet
Pin
Side B
Name
Side A
Description
Name
Description
26
GND
Ground
PERn2
Lane 2
27
PETp3
GND
Ground
28
PETn3
Transmitter differential pair,
Lane 3
GND
Ground
29
GND
Ground
PERp3
30
RSVD
Reserved
PERn3
Receiver differential pair,
Lane 3
31
PRSNT2#
Hot-Plug presence detect
GND
Ground
32
GND
Ground
RSVD
Reserved
End of the x4 connector
33
PETp4
Transmitter differential pair,
Lane 4
RSVD
Reserved
34
PETn4
GND
Ground
35
GND
Ground
PERp4
36
GND
Ground
PERn4
Receiver differential pair,
Lane 4
37
PETp5
GND
Ground
38
PETn5
Transmitter differential pair,
Lane 5
GND
Ground
39
GND
Ground
PERp5
40
GND
Ground
PERn5
Receiver differential pair,
Lane 5
41
PETp6
GND
Ground
42
PETn6
Transmitter differential pair,
Lane 6
GND
Ground
43
GND
Ground
PERp6
44
GND
Ground
PERn6
Receiver differential pair,
Lane 6
45
PETp7
GND
Ground
46
PETn7
Transmitter differential pair,
Lane 7
GND
Ground
47
GND
Ground
PERp7
48
PRSNT2#
Hot-Plug presence detect
PERn7
Receiver differential pair,
Lane 7
49
GND
Ground
GND
Ground
End of the x8 connector
Table 3: Data Pin Signal Assignment
Rev 1.0 July 2011
Page 21
RAIDDrive II PCIe SSD Datasheet
11.0 INSTALLATION
BEFORE YOU BEGIN INSTALLATION
Thanks for purchasing the RAIDDRIVE II as your data storage solution. The following
shows you simple step-by-step instructions for installing and configuring the RAIDDRIVE II.
PACKAGE CONTENTS
1. If your package is missing any of the items listed below, please contact your dealer
before you install.
2. The RAIDDRIVE II box includes the following items.
a. RAIDDRIVE II in an ESD-protective bag.
b. CD – containing drivers, user’s manual, other information for drive.
c. You can download the latest driver from Super Talent website/FORUM.
i. http://www.supertalent.com/home/forum/viewforum.php?f=52
TOOLS REQUIRED
An ESD grounding strap or mat is required. You may also require some standard tools to
open your system’s case.
INSTALLATION (PLEASE REFER TO THE USER’S MANUAL FOR THE DETAILS)
1. Unpack the RAIDDRIVE II box
2. Power PC/Server off
3. Install the RAIDDRIVE II (PCIe x8 slot should be available)
a. Plug the 4pin power cable into the RAIDDRIVE II. (*optional)
4. Power up the system
5. Go into the RAIDDRIVE II BIOS (*press F6 key)
a. Make sure it is configured right.
b. RAID0 or RAID5, Stripe size, …
c. See the “How to set up the RAIDDRIVE” pdf file in a CD for the details.
6. After the completion of OS, install the driver.
a. See the manual for the details.
7. After the completion of the driver installation, please restart the system.
Rev 1.0 July 2011
Page 22
RAIDDrive II PCIe SSD Datasheet
FOR MORE INFORMATION
For Technical Support:
If additional support is needed, please visit the Super Talent Web site at www.supertalent.com
for the following topics:



Warranty Services: Includes the warranty service policy and the RMA request forms.
Technical Information: Includes product data sheets and various SSD whitepapers.
Tools Section: Includes frequently asked questions (FAQs).
For More Information or Further Technical Support Please Contact:
Super Talent Technology
2077 North Capitol Avenue
San Jose, CA 95132
USA
Tel: +1 (408) 934-2560
Support: [email protected]
Sales: [email protected]
OEM Sales: [email protected]
CHANGE RECORD
Version
1.0
Release Date
July 1, 2011
Changes
Initial Release
Table 4: Change Record
Rev 1.0 July 2011
Page 23