Download Transcend 512MB DDR266 ECC Unbuffer Memory

Transcript
184PIN DDR266 Unbuffered DIMM
512MB With 32Mx8 CL2.5
TS64MLD72V6F5
Description
Placement
The TS64MLD72V6F5 is a 64M x 72bits Double
Data Rate SDRAM high-density for DDR266. The
TS64MLD72V6F5 consists of 18pcs CMOS 32Mx8 bits
Double Data Rate SDRAMs in 66 pin TSOP-II 400mil
packages and a 2048 bits serial EEPROM on a 184-pin
printed circuit board. The TS64MLD72V6F5 is a Dual
In-Line Memory Module and is intended for mounting into
184-pin edge connector sockets.
Synchronous design allows precise cycle control with the
use of system clock. Data I/O transactions are possible
A
on both edges of DQS. Range of operation frequencies,
programmable latencies allow the same device to be
useful for a variety of high bandwidth, high performance
memory system applications.
B
Features
•
Power supply: VDD: 2.5V ± 0.2V, VDDQ: 2.5V ± 0.2V
•
Max clock Freq: 133MHZ.
•
Double-data-rate architecture; two data transfers per
C
D
clock cycle
•
Differential clock inputs(CK and /CK)
•
DLL aligns DQ and DQS transition with CK transition
•
Auto and Self Refresh 7.8us refresh interval.
•
Data I/O transactions on both edge of data strobe.
•
Edge aligned data output, center aligned data input.
•
Serial Presence Detect (SPD) with serial EEPROM.
•
SSTL-2 compatible inputs and outputs.
•
MRS cycle with address key programs.
I
H
G
F
E
PCB : 09- 0920
CAS Latency (Access from column address) : 2.5
Burst Length (2,4,8 )
Data Sequence (Sequential & Interleave)
Transcend Information Inc.
1
184PIN DDR266 Unbuffered DIMM
512MB With 32Mx8 CL2.5
TS64MLD72V6F5
Dimensions
Pin Identification
Symbol
Inches
Function
Side
Millimeters
A
133.35±0.20
5.250±0.008
B
72.39
2.850
DQ0~DQ63,
C
6.35
0.250000
CB0~CB7
Data Input / Output.
D
2.20
0.0870
DQS0~DQS8
Data strobe input/output
E
31.75±0.20
1.250±0.00800
CK0, /CK0,
F
19.80
0.779
CK1, /CK1
G
4.00
0.157
H
12.00
0.472
I
1.27±0.10
0.050±0.004
A0~A12,BA0,BA1
Address input
Clock Input.
CK2, /CK2
(Refer Placement)
CKE0,CKE1
Clock Enable Input.
/CS0,/CS1
Chip Select Input.
/RAS
Row Address Strobe
/CAS
Column Address Strobe
/WE
Write Enable
DM0~DM8
Data-in Mask
VDD
+2.5 Voltage power supply
VDDQ
+2.5 Voltage Power Supply for DQS
VREF
Power Supply for Reference
VDDSPD
+2.5 Voltage Serial EEPROM
Power Supply
Transcend Information Inc.
2
SA0~SA2
Address in EEPROM
SCL
Serial PD Clock
SDA
Serial PD Add/Data input/output
VSS
Ground
NC
No Connection
184PIN DDR266 Unbuffered DIMM
512MB With 32Mx8 CL2.5
TS64MLD72V6F5
Pinouts:
Pin
Pin
Pin
No
Name
No
01
VREF
47
02
DQ0
48
03
VSS
49
04
DQ1
50
05
DQS0
51
06
DQ2
52
07
VDD
53
08
DQ3
54
09
NC
55
10
NC
56
11
VSS
57
12
DQ8
58
13
DQ9
59
14
DQS1
60
15
VDDQ
61
16
*CK1
62
17
*/CK1
63
18
VSS
64
19
DQ10
65
20
DQ11
66
21
CKE0
67
22
VDDQ
68
23
DQ16
69
24
DQ17
70
25
DQS2
71
26
VSS
72
27
A9
73
28
DQ18
74
29
A7
75
30
VDDQ
76
31
DQ19
77
32
A5
78
33
DQ24
79
34
VSS
80
35
DQ25
81
36
DQS3
82
37
A4
83
38
VDD
84
39
DQ26
85
40
DQ27
86
41
A2
87
42
VSS
88
43
A1
89
44
*CB0
90
45
*CB1
91
46
VDD
92
* Please refer Block Diagram
Transcend Information Inc.
Pin
Name
*DQS8
A0
*CB2
VSS
*CB3
BA1
DQ32
VDDQ
DQ33
DQS4
DQ34
VSS
BA0
DQ35
DQ40
VDDQ
/WE
DQ41
/CAS
VSS
DQS5
DQ42
DQ43
VDD
NC
DQ48
DQ49
VSS
*/CK2
*CK2
VDDQ
DQS6
DQ50
DQ51
VSS
NC
DQ56
DQ57
VDD
DQS7
DQ58
DQ59
VSS
NC
SDA
SCL
Pin
No
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
3
Pin
Name
VSS
DQ4
DQ5
VDDQ
DM0
DQ6
DQ7
VSS
NC
NC
NC
VDDQ
DQ12
DQ13
DM1
VDD
DQ14
DQ15
*CKE1
VDDQ
NC
DQ20
*A12
VSS
DQ21
A11
DM2
VDD
DQ22
A8
DQ23
VSS
A6
DQ28
DQ29
VDDQ
DM3
A3
DQ30
VSS
DQ31
*CB4
*CB5
VDDQ
CK0
/CK0
Pin
No
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
Pin
Name
VSS
DM8
A10
*CB6
VDDQ
*CB7
VSS
DQ36
DQ37
VDD
DM4
DQ38
DQ39
VSS
DQ44
/RAS
DQ45
VDDQ
/CS0
*/CS1
DM5
VSS
DQ46
DQ47
NC
VDDQ
DQ52
DQ53
NC
VDD
DM6
DQ54
DQ55
VDDQ
NC
DQ60
DQ61
VSS
DM7
DQ62
DQ63
VDDQ
SA0
SA1
SA2
VDDSPD
184PIN DDR266 Unbuffered DIMM
512MB With 32Mx8 CL2.5
TS64MLD72V6F5
Block Diagram
A0~A12,
BA0,BA1
DQ0~DQ7
A0~A12,
BA0,BA1
DQ0~DQ7
A0~A12,
BA0,BA1
DQ0~DQ7
A0~A12,
BA0,BA1
DQ0~DQ7
A0~A12,
BA0,BA1
/RAS
/RAS 32Mx8
/RAS 32Mx8
/RAS 32Mx8
/RAS 32Mx8
/RAS
/CAS
/CAS
/CAS
/CAS
CKE
DM8
DQS8
/CS
CKE
DM2
DQS2
/RAS
/CAS
/WE
/CS
CKE
32Mx8
DDR
SDRAM
DM4
DQS4
/CS
CKE
DM6
DQS6
DM5
DQS5
/RAS
/CAS
/WE
/CS
CKE
CK,/CK
A0~A12,
BA0,BA1
DQ0~DQ7
32Mx8
DDR
SDRAM
DQS
32Mx8
DDR
SDRAM
CKE
DM8
DQS8
DM
/WE
CK,/CK
CK,/CK
/CAS
DQS
/CS
CKE
/RAS
32Mx8
DDR
SDRAM
DM
/WE
A0~A12,
BA0,BA1
DQ0~DQ7
DQS
CKE
DM
/CS
/RAS
/CAS
DM
32Mx8
DDR
SDRAM
DQS
/WE
CK,/CK
/RAS
/CAS
A0~A12,
BA0,BA1
DQ0~DQ7
/WE
/CS
32Mx8
DDR
SDRAM
CB0~
CB7
DM3
DQS3
CK1,/CK1
CK0,/CK0
CK2,/CK2
A0~A12,
BA0,BA1
DQ0~DQ7
/RAS
/CAS
DQS
CK,/CK
32Mx8
DDR
SDRAM
A0~A12,
BA0,BA1
DM
/WE
DM7
DQ0~DQ7
/CAS
CK,/CK
CK,/CK
A0~A12,
BA0,BA1
DQ0~DQ7
DQS
DM
DM
DQS
CK,/CK
DQS
CKE
CK,/CK
CKE
DM1
DQS1
DM0
DQS0
/WE
/CS
DM
DQS
/WE
/CS
32Mx8
DDR
SDRAM
A0~A12,
BA0,BA1
DQ0~DQ7
/RAS
32Mx8
DDR
SDRAM
/RAS
/CAS
DQS7
CK,/CK
/RAS
/CAS
A0~A12,
BA0,BA1
DQ0~DQ7
DM6
DQS6
DQS
/CS
CKE
CKE
CK,/CK
32Mx8
DDR
SDRAM
DM
CKE1
/WE
/CS
A0~A12,
BA0,BA1
DQ0~DQ7
DQS
CK,/CK
/WE
/CS1
CKE
32Mx8
DDR
SDRAM
DM
A0~A12,
BA0,BA1
DQ0~DQ7
/RAS
/RAS
/CAS
DM5
DQS5
DQS4
/CAS
/WE
/CS
DM
CK,/CK
DM4
A0~A12,
BA0,BA1
DQ0~DQ7
32Mx8
DDR
SDRAM
DQS
CKE
DM
/CS
/RAS
/CAS
DM
/WE
32Mx8
DDR
SDRAM
DQS
/RAS
/CAS
A0~A12,
BA0,BA1
DQ0~DQ7
CKE
CB0~
CB7
DM3
DQS3
CK1,/CK1
CK0,/CK0
CK2,/CK2
A0~A12,
BA0,BA1
DQ0~DQ7
/WE
/CS
32Mx8
DDR
SDRAM
DM
DQS
CK,/CK
/CS
DQS
/WE
CK,/CK
DDR
SDRAM
DM
DQS
DM2
DQS2
DM1
DQS1
DM0
DQS0
CKE
CK,/CK
CKE
/CS
DM
CKE
/CS
DDR
SDRAM
/WE
CK,/CK
CKE0
/WE
DM
/CS
DDR
SDRAM
DQS
/WE
DQS
CK,/CK
/CAS
/WE
/CS0
DM
/CAS
DDR
SDRAM
DQ0~DQ7
A0~A12,
BA0,BA1
DQ0~DQ63
DM7
DQS7
Serial EEPROM
SCL
SCL
A0
SDA
A1
SDA
A2
SA0 SA1 SA2
This technical information is based on industry standard data and tests believed to be reliable. However, Transcend makes no warranties, either
expressed or implied, as to its accuracy and assumes no liability in connection with the use of this product. Transcend reserves the right to make changes
in specifications at any time without prior notice.
Transcend Information Inc.
4
184PIN DDR266 Unbuffered DIMM
512MB With 32Mx8 CL2.5
TS64MLD72V6F5
ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Value
Unit
Voltage on any pin relative to Vss
VIN, VOUT
-0.5 ~ 3.6
V
Voltage on VDD supply to Vss
VDD, VDDQ
-1.0 ~ 3.6
V
Storage temperature
TSTG
-55~+150
°C
Power dissipation
PD
27
W
Short circuit current
IOS
50
mA
Mean time between failure
MTBF
50
year
Temperature Humidity Burning
THB
85°C/85%, Static Stress
°C-%
Temperature Cycling Test
TC
0°C ~ 125°C Cycling
°C
Note: Permanent device damage may occur if ABSOLUTE MAXIMUM RATINGS are exceeded.
Functional operation should be restricted to recommended operating condition.
Exposure to higher than recommended voltage for extended periods of time could affect device reliability.
DC OPERATING CONDITIONS
Recommended operating conditions (Voltage referenced to Vss = 0V, TA = 0 to 70°C)
Parameter
Symbol
Min
Max
Unit
Note
Supply voltage
VDD
2.3
2.7
V
I/O Supply voltage
VDDQ
2.3
2.7
V
I/O Reference voltage
VREF
VDDQ/2-50mV VDDQ/2+50mV
V
1
I/O Termination voltage
VTT
VREF-0.04
VREF+0.04
V
2
Input logic high voltage
VIH(DC)
VREF+0.15
VDDQ+0.3
V
4
Input logic low voltage
VIL(DC)
-0.3
VREF-0.15
V
4
Input Voltage Level, CK and /CK inputs
VIN(DC)
-0.3
VDDQ+0.3
V
Input Differential Voltage, CK and /CK inputs
VID(DC)
0.3
VDDQ+0.6
V
3
Input crossing point voltage, CK and /CK inputs
VIX(DC)
1.15
1.35
V
5
Input leakage current
II
-2
2
uA
Output leakage current
IOZ
-5
5
uA
Output High Current (Normal strength driver)
IOH
-16.8
mA
VOUT= VTT + 0.84V
Output Low Current (Normal strength driver)
IOL
16.8
mA
VOUT= VTT – 0.84V
Output High Current (Half strength driver)
IOH
-9
mA
VOUT= VTT + 0.45V
Output High Current (Half strength driver)
IOL
9
mA
VOUT= VTT - 0.45V
Note: 1. Includes ± 25mV margin for DC offset on VREF, and a combined total of ± 50mV margin for all AC noise and
DC offset on VREF, bandwidth limited to 20MHz. The DRAM must accommodate DRAM current spikes on
VREF and internal DRAM noise coupled. TO VREF, both of which may result in VREF noise. VREF should be
de-coupled with an inductance of <=3nH.
2. VTT is not applied directly to the device. VTT is a system supply for signal termination resistors, is expected to
be set equal to VREF, and must track variations in the DC level of VREF
3. VID is the magnitude of the difference between the input level on CK and the input level on /CK.
4. These parameters should be tested at the pin on actual components and may be checked at either the pin or
the pad in simulation. The AC and DC input specifications are relative to a VREF envelop that has been
bandwidth limited to 200MHZ.
5. The value of VIX is expected to equal 0.5*VDDQ of the transmitting device and must track variations in the dc
level of the same.
Transcend Information Inc.
5
184PIN DDR266 Unbuffered DIMM
512MB With 32Mx8 CL2.5
TS64MLD72V6F5
DC CHARACTERISTICS
(Recommended operating condition unless otherwise noted, VDD=2.7V TA = 10°C)
Parameter
Symbol
Max.
Unit
Note
Operating current - One bank Active-Precharge; tRC=tRCmin;
DQ, DM and DQS inputs changing twice per clock cycle;
IDD0
1610
mA
Address and control inputs changing once per clock cycle
Operating current - One bank operation; One bank open, Burst=4; Reads
IDD1
1940
mA
- Refer to the following page for detailed test condition.
Percharge power-down standby current; All banks idle; power –down mode;
IDD2P
505
mA
CKE = <VIL(max); VIN = VREF for DQ,DQS and DM
Precharge Floating standby current; CS# > =VIH(min);All banks idle;
CKE > = VIH(min); Address and other control inputs changing once per clock
IDD2F
900
mA
cycle; VIN = VREF for DQ,DQS and DM
Active power - down standby current; one bank active; power-down mode;
IDD3P
810
mA
CKE<= VIL (max); VIN = VREF for DQ, DQS and DM
Active standby current; CS# >= VIH(min); CKE>=VIH(min);
One bank active; active - precharge; tRC=tRASmax;
IDD3N
1170
mA
DQ, DQS and DM inputs changing twice per clock cycle;
Address and other control inputs changing once per clock cycle
Operating current - burst read; Burst length = 2; reads; continuous burst;
IDD4R
2565
mA
One bank active; address and control inputs changing once per clock cycle;
50% of data changing at every burst; lout = 0 mA
Operating current - burst write; Burst length = 2; writes; continuous burst;
One bank active address and control inputs changing once per clock cycle;
IDD4W
3240
mA
DQ, DM and DQS inputs changing twice per clock cycle,
50% of input data changing at every burst
Auto refresh current; tRC = tRFC(min),
IDD5
2565
mA
10*tCK for DDR266at 133Mhz; distributed refresh
Self refresh current; CKE <= 0.2V; External clock should be on;
IDD6
54
mA
Operating current - Four bank operation;
IDD7
4140
mA
Four bank interleaving with BL=4
-Refer to the following page for detailed test condition
1. Module IDD was calculated on the basis of component IDD and can be differently measured according to DQ
Note:
loading capacitor.
Transcend Information Inc.
6
184PIN DDR266 Unbuffered DIMM
512MB With 32Mx8 CL2.5
TS64MLD72V6F5
AC OPERATING CONDITIONS
Parameter
Symbol
Min
Max
Unit
Input High (Logic 1) Voltage, DQ, DQS and DM signals
VIH(AC)
VREF + 0.31
Input Low (Logic 0) Voltage, DQ, DQS and DM signals
VIL(AC)
V
3
VREF - 0.31
V
3
Input Differential Voltage, CK and /CK inputs
VID(AC)
0.7
VDDQ + 0.6
V
1
Input Crossing Point Voltage, CK and /CK inputs
VIX(AC)
0.5*VDDQ - 0.2
0.5*VDDQ + 0.2
V
2
Note
Note: 1. VID is the magnitude of the difference between the input level on CK and the input on /CK.
2. The value of VIX is expected to equal 0.5*V DDQ of the transmitting device and must track variations in the
DC level of the same.
3. These parameters should be tested at the pin on actual components and may be checked at either the pin or
the pad in simulation. The AC and DC input specifications are relative to a VREF envelope that has been
bandwidth limited 20MHz.
AC OPERATING TEST CONDITIONS (VDD=2.5, VDDQ=2.5, TA=0 to 70°C)
Parameter
Input reference voltage for Clock
Input signal maximum peak swing
Input Levels (VIH/VIL)
Input timing measurement reference level
Output timing measurement reference level
Output load condition
Value
0.5*VDDQ
1.5
VREF+0.31/VREF-0.31
VREF
VTT
See Load Circuit
Unit
V
V
V
V
V
Note
Max
87
53
53
34
8
8
8
Unit
pF
pF
pF
pF
pF
pF
pF
VTT=0.5*VDDQ
RT=50ohm
Output
ZO=50ohm
VREF
=0.5*VDDQ
CLOAD=30pF
Output Load circuit
Input/Output CAPACITANCE (VDD = 2.5V, VDDQ = 2.5V,TA = 25°C, f = 1MHz)
Parameter
Input capacitance (A0~A12, BA0~BA1, /RAS, /CAS, /WE)
Input capacitance (CKE0, CKE1)
Input capacitance (/CS0, /CS1)
Input capacitance (CK0~CK2)
Input capacitance (DM0~DM8)
Data and DQS input/output capacitance (DQ0~DQ63)
Data input/output capacitance (CB0~CB7)
Transcend Information Inc.
Symbol
CIN1
CIN2
CIN3
CIN4
CIN5
COUT1
COUT2
7
Min
69
44
44
27
6
6
6
184PIN DDR266 Unbuffered DIMM
512MB With 32Mx8 CL2.5
TS64MLD72V6F5
AC Timing Parameters & Specifications
(These AC characteristics were tested on the Component)
Parameter
Row cycle time
Refresh row cycle time
Row active time
/RAS to /CAS delay
Row active to Row active delay
Row active to Row active delay
Write recovery time
Last data in to Read command
Col. Address to Col. Address delay
Clock cycle time
Clock high level width
Clock low level width
DQS-out access time from CK /CK
Output data access time from CK /CK
Data strobe edge to output data edge
Read Preamble
Read Postamble
CK to valid DQS-in
DQS-in setup time
DQS-in hold time
DQS falling edge to CK rising-setup time
DQS falling edge from CK rising-hold time
DQS-in high level width
DQS-in low level width
DQS-in cycle time
Address and Control input setup time
Address and Control input hold time
Data-out high-impedance time from CK, /CK
Data-out low-impedance time from CK, /CK
Mode register set cycle time
DQ & DM setup time to DQS
DQ & DM hold time to DQS
DQ & DM input pulse width
Power down exit time
Exit self refresh to non-Read command
Exit self refresh to read command
Refresh interval time
Clock half period
Symbol
tRC
tRFC
tRAS
tRCD
tRP
tRRD
tWR
tCDLR
tCCD
tCK
tCH
tCL
tDQSCK
tAC
tDQSQ
tRPRE
tRPST
tDQSS
tWPRES
tWPREH
tDSS
tDSH
tDQSH
tDQSL
tDSC
tIS
tIH
tHZ
tLZ
tMRD
tDS
tDH
tDIPW
tPDEX
tXSNR
tXSRD
tREF
tHP
Min
65
75
45
20
20
15
15
1
1
7.5
0.45
0.45
-0.75
-0.75
0.9
0.4
0.75
0
0.25
0.2
0.2
0.35
0.35
0.9
0.9
0.9
-0.75
-0.75
15
0.5
0.5
1.75
7.5
75
200
7.8
tCLmin or
tCHmin
Max
120K
0.55
0.55
0.75
0.75
0.5
1.1
0.6
1.25
1.1
0.75
0.75
Unit
ns
ns
ns
ns
ns
ns
ns
tCK
tCK
ns
tCK
tCK
ns
ns
ns
tCK
tCK
tCK
ns
tCK
tCK
tCK
tCK
tCK
tCK
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tCK
us
ns
Note
2
1
Data hold skew factor
tQHS
0.75
ns
DQS write postamble time
tWPST
0.4
0.6
tCK
3
Note: 1. Maximum burst refresh of 8
2. The specific requirement is that DQS be valid (High or Low) on or before this CK edge. The case shown
(DQS going from High_Z to logic Low) applies when no writes were previously in progress on the bus. If a
previous write was in progress, DQS could be High at this time, depending on tDQSS.
3. The Maximum limit for this parameter is not a device limit. The device will operate with a great value for this
parameter, but system performance (bus turnaround) will degrade accordingly.
Transcend Information Inc.
8
184PIN DDR266 Unbuffered DIMM
512MB With 32Mx8 CL2.5
TS64MLD72V6F5
SIMPLIFIED TRUTH TABLE
COMMAND
Extended
Register
Mode Register Set
Register
Mode Register Set
Auto Refresh
Refresh
Self
Refresh
Entry
Exit
Bank Active & Row Addr.
(V=Valid, X=Don’t Care, H=Logic High, L=Logic Low)
CKEn-1
CKEn
/CS
/RAS
/CAS
/WE
H
X
L
L
L
L
OP CODE
1,2
X
L
L
L
L
OP CODE
1,2
L
L
L
H
X
H
H
H
L
L
H
H
H
H
X
X
X
X
L
L
H
H
V
X
L
H
L
H
V
L
H
H
H
Column Address
Auto Precharge Enable
Column Address
Auto Precharge Enable
Burst Stop
Precharge
All Banks
Entry
X
X
H
X
H
L
Active Power Down
Exit
Entry
L
H
H
L
Precharge Power
Down Mode
L
H
L
H
L
H
L
H
X
X
X
L
V
V
V
X
X
X
X
H
X
X
X
L
H
H
H
H
X
X
X
L
V
V
V
No Operation Command
L
7.
8.
9.
Column
(A0~A9)
V
Column
Address
H
(A0~A9)
X
V
L
X
H
4
4
4
4, 6
7
X
5
X
H
X
H
H
X
X
X
X
X
8
9
X
L
5.
6.
3
3
Address
H
L
L
H
4.
H
L
3
3
X
Exit
DM
1.
2.
3.
L
Note
Row Address
L
H
H
Bank Selection
A0~A9,A11, A12
L
Auto Precharge Disable
Write &
A10/AP
X
Auto Precharge Disable
Read &
Note:
BA0,1
H
H
H
9
OP Code: Operand Code. A0 ~ A12 & BA0 ~ BA1: Program keys. (@EMRS/MRS)
EMRS/ MRS can be issued only at all banks precharge state. A new command can be issued 2 clock cycles after EMRS or MRS.
Auto refresh functions are same as the CBR refresh of DRAM. The automatic precharge without row precharge command is meant by
"Auto". Auto/self refresh can be issued only at all banks precharge state.
BA0 ~ BA1: Bank select addresses. If both BA0 and BA1 are "Low" at read, write, row active and precharge, bank A is selected. If both
BA0 is "High" and BA1 is "Low" at read, write, row active and precharge, bank B is selected. If both BA0 is "Low" and BA1 is "High" at
read, write, row active and precharge, bank C is selected. If both BA0 and BA1 are "High" at read, write, row active and precharge, bank
D is selected.
If A10/AP is "High" at row precharge, BA0 and BA1 are ignored and all banks are selected.
During burst write with auto precharge, new read/write command cannot be issued. Another bank read/write command can be issued
after the end of burst. New row active of the associated bank can be issued at tRP after the end of burst.
Burst stop command is valid at every burst length.
DM sampled at the rising and falling edges of the DQS and Data-in is masked at the both edges (Write DM latency is 0).
This combination is not defined for any function, which means "No Operation (NOP)" in DDR SDRAM.
Transcend Information Inc.
9
184PIN DDR266 Unbuffered DIMM
512MB With 32Mx8 CL2.5
TS64MLD72V6F5
Serial Presence Detect Specification
Serial Presence Detect
Byte No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Function Described
# of Bytes Written into Serial Memory
Total # of Bytes of S.P.D Memory
Fundamental Memory Type
# of Row Addresses on this Assembly
# of Column Addresses on this Assembly
# of Module Rows on this Assembly
Data Width of this Assembly
Data Width of this Assembly
VDDQ and Interface Standard of this Assembly
DDR SDRAM Cycle Time at CAS Latency=2.5
DDR SDRAM Access Time from Clock at CL=2.5
DIMM configuration type (non-parity, Parity, ECC)
Refresh Rate Type
Primary DDR SDRAM Width
Error Checking DDR SDRAM Width
Min Clock Delay for Back to
Back Random Column Address
Burst Lengths Supported
# of banks on each DDR SDRAM device
CAS Latency supported
CS Latency
WE Latency
21
DDR SDRAM Module Attributes
22
DDR SDRAM Device Attributes: General
23
24
25
26
27
28
29
30
31
32
33
34
35
36-61
62
63
DDR SDRAM Cycle Time CL=2.0
DDR SDRAM Access from Clock CL=2.0
DDR SDRAM Cycle Time CL=1.5
DDR SDRAM Access from Clock CL=1.5
Minimum Row Precharge Time (tRP)
Minimum Row Active to Row Activate delay (tRRD)
Minimum RAS to CAS Delay (tRCD)
Minimum active to Precharge time (tRAS)
Module ROW density
Command/Address Input Setup Time
Command/Address Input Hold Time
Data Signal Input Setup Time
Data Signal Input Hold Time
Superset Information
SPD Data Revision Code
Checksum for Bytes 0-62
Transcend Information Inc.
10
Standard Specification
128bytes
256bytes
DDR SDRAM
13
10
2 bank
72bits
0
SSTL 2.5V
7.5ns
.0.75ns
ECC
7.8us/Self Refresh
X8
X8
tCCD=1CLK
Vendor Part
80
08
07
0D
0A
02
48
00
04
75
75
02
82
08
08
01
2,4,8
4 bank
2, 2.5
0 CLK
1 CLK
Registered address &
control inputs and
on-card DLL
+/-0.2V voltage
tolerance
10ns
.0.75ns
20ns
15ns
20ns
45ns
256MB
0.9ns
0.9ns
0.5ns
0.5ns
-
0E
04
0C
01
02
20
00
A0
75
00
00
50
3C
50
2D
40
90
90
50
50
00
00
D2
184PIN DDR266 Unbuffered DIMM
512MB With 32Mx8 CL2.5
TS64MLD72V6F5
64-71 Manufacturers JEDEC ID
72
Manufacturing Location
Transcend
T
7F, 4F
54
54 53 36 34 4D 4C
73-90 Manufacturers Part Number
TS64MLD72V6F5
44 37 32 56 36 46
35 20 20 20 20 20
91-92
93-94
95-98
99-127
128~255
Revision Code
Manufacturing Date
Assembly Serial Number
Manufacturer Specific Data
Unused Storage Locations
Transcend Information Inc.
By Manufacturer
By Manufacturer
Undefined
11
Variable
Variable
-