Download Chief CMA330-G
Transcript
INSTALLATION INSTRUCTIONS Instrucciones de instalación Installationsanleitung Instruções de Instalação Istruzioni di installazione Installatie-instructies Instructions d´installation 8" Off-Set Ceiling Plate Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description CMA330 CMA330 Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries (collectively "Milestone"), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind. Milestone makes no representation of warranty, expressed or implied, regarding the information contained herein. Milestone assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document. WARNING: Do not use this product outdoors. IMPORTANT ! : These CMA mounts are designed to be: • • • mounted to a 2" x 6" wood framework ceiling; mounted to a 8" concrete ceiling with a drywall covering of a maximum of 5/8"; mounted to a suspended metal framing channel ceiling. WARNING: Do NOT attach to vertical mounting surfaces such as walls or angled ceilings! --SAVE THESE INSTRUCTIONS-Chief® is a registered trademark of Milestone AV Technologies. All rights reserved. IMPORTANT SAFETY INSTRUCTIONS WARNING: A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions. CAUTION: A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions. WARNING: Failure to read, thoroughly understand, and follow all instructions can result in serious personal injury, damage to equipment, or voiding of factory warranty! It is the installer’s responsibility to make sure all components are properly assembled and installed using the instructions provided. WARNING: Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the component. WARNING: Exceeding the weight capacity can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the combined weight of all components attached to the CMA330 does not exceed 500 lbs (226.8 kg). WARNING: Use this mounting system only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer. WARNING: Never operate this mounting system if it is damaged. Return the mounting system to a service center for examination and repair. 2 Installation Instructions CMA330 DIMENSIONS 8.00 203.2 DIMENSIONS: INCHES [MILLIMETERS] TOOLS REQUIRED FOR INSTALLATION 1/4" 5/32" - Security [Included] 5/32" PARTS B (1) 5/32" (security) A (1) (CMA330 Ceiling Plate) C (1) 5/16-18 x 3/8" D (1) 5/16-18 x 1/4" 3 CMA330 Installation Instructions LEGEND Tighten Fastener Pencil Mark Apretar elemento de fijación Marcar con lápiz Befestigungsteil festziehen Stiftmarkierung Apertar fixador Marcar com lápis Serrare il fissaggio Segno a matita Bevestiging vastdraaien Potloodmerkteken Serrez les fixations Marquage au crayon Loosen Fastener Drill Hole Aflojar elemento de fijación Perforar Befestigungsteil lösen Bohrloch Desapertar fixador Fazer furo Allentare il fissaggio Praticare un foro Bevestiging losdraaien Gat boren Desserrez les fixations Percez un trou By Hand Optional A mano Opcional Von Hand Optional Com a mão Opcional A mano Opzionale Met de hand Optie À la main En option Hex-Head Wrench Security Wrench Llave de cabeza hexagonal Llave de seguridad Sechskantschlüssel Sicherheitsschlüssel Chave de cabeça sextavada Chave de segurança Chiave esagonale Chiave di sicurezza Zeskantsleutel Veiligheidssleutel Clé à tête hexagonale Clé de sécurité Socket Wrench Llave de cubo Steckschlüssel Chave de caixa Chiave a brugola Dopsleutel Clé à douilles 4 Installation Instructions CMA330 INSTALLATION AND INSTALLATION These CMA mounts are designed for attachment to a 2" x 6" wood framework ceiling, a concrete ceiling or a suspended metal framing channel ceiling, and provides vertical adjustments in 3/4" increments. 2 x4 WARNING: Do NOT attach to vertical mounting surfaces such as walls or angled ceilings! (A) WARNING: IMPROPER INSTALLATION CAN LEAD TO LIFT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT! It is the installer’s responsibility to make certain the structure to which the mount is being attached is capable of supporting five times the weight of the CMA mount and all attached equipment. Reinforce the structure as required before installing the mount. NOTE: The following instructions assume a suitable mounting structure and surface exists prior to installation. Installing to a Wood Framework (Joists) 1. 3 Using ceiling plate (A) as a template, mark locations of four pilot holes (See Figure 1). Ensure the marks are in the center of wood joists. x4 Figure 2 NOTE: Drywall not shown for clarity. (A) 1 x4 Figure 3 Installing to a Suspended Ceiling Figure 1 2. Drill 1/4" diameter pilot holes into wood joists (See Figure 2). Ensure pilot holes are straight. 3. Install and tighten four 3/8" x 2-1/2" (minimum) Grade 2 lag screws (not included) through CMA330 (A), into wood joist (See Figure 2). See Figure 3 for dimensions details. NOTE: The CMA mount may be suspended from four 3/8 in. diameter ASTM A307 or better threaded rods (not provided) which are secured to a 1-5/8" x 1-5/8" 12ga metal framing strut channel (spanning a maximum of 4 feet--not provided) by ASTM A307 or better 3/8" channel nuts (not provided). Threaded rods must have 16 threads per square inch. 1. 2. Insert the rods into the four bolt holes in the CMA mount. Secure the threaded rods to the CMA mount with ASTM A307 or better 3/8" jam nuts (not provided) and washers (one of each on inside and one of each on outside-not provided). See Figure 3 for dimensions details. 5 CMA330 Installation Instructions Installing to a Solid Concrete Ceiling Structure (A) WARNING: The CMA330 is designed to be mounted to a concrete ceiling with a minimum thickness of 8" and a maximum drywall covering of 5/8". WARNING: Fischer Ux10 anchors (not provided) must be installed into structurally sound solid concrete. Installation into hollow concrete block, mortar, or concrete that exhibits cracking, spalling, or other defects may result in failure of anchor and serious personal injury or damage to equipment. 1. Use four Ux10 anchors (not provided) to secure CMA mount into solid concrete ceiling. See Figure 3 for dimensions details. 2. Place CMA mount over anchors, aligning bolt holes in CMA mount with installed anchors. 3. Secure CMA mount to ceiling using four 3/8" Grade 2 flat washers (not provided) and four 3/8" x 2 1/2" Grade 2 bolts (not provided) tightened over anchors. (D) x 1 3 2 (C) x 1 Installing Extension Column Figure 4 WARNING: Exceeding the weight capacity can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the combined weight of all components attached to the CMA330 does not exceed 500 lbs (227 kg). 1. Route cables through extension column (not included). 2. Install 1-1/2" NPT following ANSI/ASME B1.20.1 (Schedule 40, 0.154" minimum thickness aluminum - ASTM B221) threaded extension column (not included) into CMA330 until tight, with a minimum of four threads engaged. 3. Secure extension column by one of the following methods (See Figure 4): • • 6 Install one 5/16" x 3/8" set screw (C) into threaded hole, tightening firmly against column. OPTIONAL: Install one 5/16" x 1/4" security set screw (D) into threaded hole, tightening firmly against column. 4. Complete installation following mount installation instructions. Installation Instructions CMA330 7 CMA330 Installation Instructions USA/International Europe Chief Manufacturing, a products division of Milestone AV Technologies 8800-002140 Rev03 2012 Milestone AV Technologies, a Duchossois Group Company www.chiefmfg.com 11/12 Asia Pacific A P F A P F A 6436 City West Parkway, Eden Prairie, MN 55344 800.582.6480 / 952.225.6000 877.894.6918 / 952.894.6918 Franklinstraat 14, 6003 DK Weert, Netherlands +31 (0) 495 580 852 +31 (0) 495 580 845 Office No. 1 on 12/F, Shatin Galleria 18-24 Shan Mei Street Fotan, Shatin, Hong Kong P 852 2145 4099 F 852 2145 4477