Download Chief KONTOUR K2C100B
Transcript
INSTALLATION INSTRUCTIONS Istruzioni di installazione Installatie-instructies Instructions d´installation Instrucciones de instalación Installationsanleitung Instruções de Instalação K2W100 K2P100 K2C100 K2W200 K2P200 K2C200 Monitor Arm Series Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description K2 Series K2 Series Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries (collectively "Milestone"), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind. Milestone makes no representation of warranty, expressed or implied, regarding the information contained herein. Milestone assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document. Chief® is a registered trademark of Milestone AV Technologies. All rights reserved. IMPORTANT SAFETY INSTRUCTIONS! WARNING: A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions. CAUTION: A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions. WARNING: Failure to read, thoroughly understand, and follow all instructions can result in serious personal injury, damage to equipment, or voiding of factory warranty! It is the installer’s responsibility to make sure all components are properly assembled and installed using the instructions provided. WARNING: Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the component. The wall to which the mount is being attached may have a maximum drywall thickness of 5/8" (1.6cm). WARNING: Exceeding the weight capacity can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the combined weight of all components located between the K2 Series Monitor Arm up to (and including) the display does not exceed 40 lbs (18.14 kg) for single arm mounts or 25 lbs (11.34 kg) per arm on dual arm mounts. Use with products heavier than the maximum weight indicated may result in collapse of the mount and its accessories causing possible injury. WARNING: Use this mounting system only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer. 2 WARNING: Never operate this mounting system if it is damaged. Return the mounting system to a service center for examination and repair. WARNING: Do not use this product outdoors. --SAVE THESE INSTRUCTIONS!-- Installation Instructions K2 Series DIMENSIONS K2C100 188.1 7.41 (8.85 [224.7] FOR LOWER PROFILE INSTALL) LOWER PROFILE INSTALL EXTENSION 100 3.94 75 2.95 MAX 19.2 [487.7] PITCH TENSION KNOB PITCH RANGE 15 90 INTERFACE ROTATION MANUAL HEIGHT ADJUSTMENT RANGE 244.5 9.63 289.7 11.41 MAX 21.04 [534.2] LOWER PROFILE CABLE MANAGEMENT HEIGHT ADJUSTMENT KNOB DESKTOP THICKNESS RANGE 12.7 .50 MAX 3.25 [82.6] 76.2 3.00 131.7 5.19 K2C200 MAXIMUM WIDTH OF 2 PARALLEL, FORWARD-FACING DISPLAYS: 28.8" [731.5] EXTENSION MIN 2.98 [75.7] MAX 17.4 [450.7] 100 3.94 90 INTERFACE ROTATION 75 2.95 PITCH RANGE 15 PITCH TENSION KNOB MANUAL HEIGHT ADJUSTMENT RANGE 242.9 9.56 CABLE MANAGEMENT HEIGHT ADJUSTMENT KNOB DESKTOP THICKNESS RANGE 12.7 .50 MAX 3.25 [82.6] 291.3 11.47 MAX 21.04 [534.2] 76.2 3.00 133.3 5.25 3 Installation Instructions K2 Series DIMENSIONS (CONTINUED) K2W100 100 3.94 75 2.95 90 INTERFACE ROTATION PITCH RANGE 15 EXTENSION MIN 2.98 [75.7] MAX 17.2 [436.9] PITCH TENSION KNOB 149.6 5.89 263.7 10.38 5.508 81.7 3.22 CABLE MANAGEMENT 61.6 2.43 K2W200 MAXIMUM WIDTH OF 2 PARALLEL, FORWARD-FACING DISPLAYS: 28.25" [717.6] 100 3.94 75 2.95 90 INTERFACE ROTATION EXTENSION MIN 2.98 [75.7] MAX 17.2 [436.9] PITCH RANGE 15 PITCH TENSION KNOB 147.7 5.81 142.6 5.61 81.7 3.22 CABLE MANAGEMENT 61.9 2.44 4 K2 Series Installation Instructions DIMENSIONS (CONTINUED) K2P100 POLE CLAMP RANGE 1.50 [38.1] - 1.90 [48.3] 78.8 3.10 MAX EXTENSION 16.60 [421.6] 100 3.94 90 INTERFACE ROTATION 75 2.95 PITCH TENSION KNOB PITCH RANGE 15 10.484 CABLE MANAGEMENT K2P200 POLE CLAMP RANGE 1.50 [38.1] - 1.90 [48.3] MAXIMUM WIDTH OF 2 PARALLEL, FORWARD-FACING DISPLAYS: 28.25" [717.6] EXTENSION RANGE 2.98 [75.7] 16.48 [418.5] 100 3.94 75 2.95 90 INTERFACE ROTATION PITCH RANGE 15 10.58 CABLE MANAGEMENT 5 PITCH TENSION KNOB K2 Series Installation Instructions LEGEND 6 Tighten Fastener Pencil Mark Apretar elemento de fijación Marcar con lápiz Befestigungsteil festziehen Stiftmarkierung Apertar fixador Marcar com lápis Serrare il fissaggio Segno a matita Bevestiging vastdraaien Potloodmerkteken Serrez les fixations Marquage au crayon Loosen Fastener Drill Hole Aflojar elemento de fijación Perforar Befestigungsteil lösen Bohrloch Desapertar fixador Fazer furo Allentare il fissaggio Praticare un foro Bevestiging losdraaien Gat boren Desserrez les fixations Percez un trou Phillips Screwdriver Adjust Destornillador Phillips Ajustar Kreuzschlitzschraubendreher Einstellen Chave de fendas Phillips Ajustar Cacciavite a stella Regolare Kruiskopschroevendraaier Afstellen Tournevis à pointe cruciforme Ajuster Open-Ended Wrench Remove Llave de boca Quitar Gabelschlüssel Entfernen Chave de bocas Remover Chiave a punte aperte Rimuovere Steeksleutel Verwijderen Clé à fourche Retirez By Hand Optional A mano Opcional Von Hand Optional Com a mão Opcional A mano Opzionale Met de hand Optie À la main En option Hex-Head Wrench Security Wrench Llave de cabeza hexagonal Llave de seguridad Sechskantschlüssel Sicherheitsschlüssel Chave de cabeça sextavada Chave de segurança Chiave esagonale Chiave di sicurezza Zeskantsleutel Veiligheidssleutel Clé à tête hexagonale Clé de sécurité K2 Series Installation Instructions TOOLS REQUIRED FOR INSTALLATION #2 3/16" (included) 5/32" (included with K1P Series only) PARTS A (1) [monitor arm] (K2W100 shown) B (4 or 8)* M4x14mm C (4 or 8)* M4x25mm *8 screws and washers included with dual arm mounts D (4 or 8)* M10x5.3x10 [included with K2W Series (wall mount) only!] F (2) 1/4 x 2 1/2" G (2) 1/4" E (1) [wall bracket] [included with K2P Series (pole mount) only!] H (1) [pole clamp] J (4) 1/4-20 x 1 1/2" M (1) 3/16" 7 K (4) 1/4-20 x 1" L (1) 5/32" K2 Series Installation Instructions Assembly And Installation IMPORTANT ! : IF you will be installing a SINGLE display with RECESSED mounting holes, then proceed to "DISPLAY INSTALLATION" before continuing with this mount installation procedure. 1 Connecting K2C Series (column mount) to Desk Standard Installation 1. Loosen clamp screw until enough space is created between clamp and mount to allow for desk mounting. (See Figure 1) NOTE: If space is limited behind desk (i.e. against wall, etc.), remove clamp screw and attachment entirely and reattach clamp screw prior to Step 3! (See Figure 2) 2. Place mount on top of desk at desired mounting location. (See Figure 1) 3. Tighten clamp using clamp screw until mount is securely fastened to desk. (See Figure 1) 2 Figure 3 1 3 2 3. Rotate mount in 90 degrees in either direction prior to reinstalling onto column. (See Figure 4) 4. Reinstall onto column and adjust to desired height. (See Figure 4) 5. Reinstall top cap to column. (See Figure 4) desk 5 Figure 1 3 Figure 2 Low Profile Installation (KC2 Series Only) 1. Remove top cap from column. (See Figure 3) 2. Slide mount assembly off of column. (See Figure 3) 8 4 Figure 4 6. Proceed with standard installation to desk as shown in "Standard Installation" section. K2 Series Installation Instructions (E) set screw 6 3 3/16" x 2 1/2" side view 5 4 (F) x 2 (E) (G) x 2 Figure 5 Connecting K2W Series (wall mount) to Wall 1. Determine mounting location on wall. 2. Use a stud finder to locate stud. 3. Use wall bracket to mark and drill two 3/16" x 2 1/2" holes in wall at desired mounting location. (See Figure 5) 4. Use two 1/4-2 1/2" hex head lag screws (F) and two 1/4" washers (G) to install wall bracket onto wall. (See Figure 5) 3 (J or K) x 4 IMPORTANT ! : Overtightening screws (F) may cause bracket to compress into soft wall surface resulting in difficult mount installation or improper engaging of set screw in Step 6. (A) 5. Hang monitor arm (A) over wall bracket. (See Figure 5) 6. Secure monitor arm to wall bracket by tightening set screw. Ensure set screw engages back side of wall bracket (E) to properly secure mount. (See Figure 5) Connecting K2P Series (pole mount) to Wall 1. Determine approximate location for mount keeping in mind display size, extension, height adjustment requirements. 2. Place mount (A) against pole with clamp (H) on opposite side of pole. (See Figure 6) 3. Using 5/32" hex key (L) and appropriate length screws, loosely attach K1P assembly to pole clamp (H). If installing to 1 1/2" NPT pipe, use 1/4-20 x 1 1/2" button head cap screws (J). If installing to 1 1/2" diameter pipe, use 1/4-20 x 1" button head cap screws (K). (See Figure 6) 4. Position mount at desired height and orientation. 5. Equally tighten screws against mount and the pole clamp. (H) Figure 6 9 K2 Series Installation Instructions Display Installation Recessed Mounting Holes The mounting holes on the back of the display will either be flush with the back surface or recessed into the back surface. Refer to the applicable installation procedure. 1. Ensure Centris bracket is able to swivel and tilt easily, yet still be tight enough to hold display in desired position. Adjust as required before proceeding. See "ADJUSTMENT" for detail. Flush Mounting Holes 2. Carefully place display face down on protective surface. 3. Place the four spacers (D) over each of the mount holes on the back of the display. (See Figure 8) 4. Pick up and orient the mount (A) so that the mounting holes are aligned with the holes in the spacers; rotate the bracket as required. (See Figure 8) 5. Using Phillips screwdriver, install four M4x25mm screws (C) through the mounting holes, through the spacers and into the display. (See Figure 8) 6. Tighten all four screws. Do not overtighten! CAUTION: Using screws of improper size may damage your display! Proper screws will easily and completely thread into display mounting holes. CAUTION: Inadequate thread engagement in display may cause display to fall! Back out screws ONLY as necessary to allow installation of Centris bracket! 1. Ensure faceplate is able to swivel and tilt easily, yet still be tight enough to hold display in desired position. Adjust as required before proceeding. See "ADJUSTMENT" for detail. (See Figure 7) 2. Using Phillips screwdriver, carefully install two M4x12mm screws (B) into the upper mounting holes on the display. Thread screws completely into display, then back out 3 complete turns. (See Figure 7) 3. 5 (C) x 4 Pick up and align display so that screws (B) (installed on the back of the display in the previous step) fit into the mounting holes on the faceplate. Rotate the bracket as required. Lower the display firmly into place. (See Figure 7) (A) 3 (D) x 4 2 3 Figure 8 Adjustments Column Height Adjustment (K2C Series only) 4 1. Loosen column adjustment knob. (See Figure 9) 2. Adjust height to desired level. (See Figure 9) 3. Tighten column adjustment knob. (See Figure 9) 1 2 Figure 7 4. Using Phillips screwdriver, install two remaining M4x14mm Phillips screws (B) through the lower mounting holes in faceplate into the display. (See Figure 7) 5. Tighten all four screws (B). Do not overtighten! 10 Figure 9 3 Installation Instructions K2 Series Pivot Adjustment Range Swing Arm Pivot Adjustment Single Arm Models (K2C100, K2W100 and K2P100) 1. Adjust pivot position as desired. (See Figure 12) 1. 2. Adjust pivot point tension screws to change pivot adjustment tension. (See Figure 12) Adjust arm angle as desired up to 90 degrees in either direction. (See Figure 10) WARNING: Swinging the arm beyond 90 degrees may result in the mount slipping off the desk causing serious injury! edge of desk or wall face (top view) pivot point tension Figure 12 +/- 90 degrees range of motion Cable Management 1. Route cables through cable management channels. (See Figure 13) 1 Figure 10 Dual Arm Models (K2C200, K2W200 AND K2P200) 1. Adjust arm angles as desired within a 90 degree range from the edge of desk or wall and a perpendicular centerline of mount. (See Figure 11) cable (typical) 1 1 WARNING: Swinging the arm beyond this range may result in the mount slipping of the desk causing serious injury! (top view) edge of desk or wall face Figure 13 90 degrees range of motion per arm perpendicular centerline Figure 11 11 K2 Series Installation Instructions USA/International Europe Chief Manufacturing, a products division of Milestone AV Technologies 8800-002060 Rev 03 2011 Milestone AV Technologies, a Duchossois Group Company www.chiefmfg.com 12/11 Asia Pacific A P F A P F A 8401 Eagle Creek Parkway, Savage, MN 55378 800.582.6480 / 952.894.6280 877.894.6918 / 952.894.6918 Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands +31 (0)40 2668620 +31 (0)40 2668615 Office No. 1 on 12/F, Shatin Galleria 18-24 Shan Mei Street Fotan, Shatin, Hong Kong P 852 2145 4099 F 852 2145 4477