Download Chief KONTOUR K2C100B

Transcript
INSTALLATION INSTRUCTIONS
Istruzioni di installazione
Installatie-instructies
Instructions d´installation
Instrucciones de instalación
Installationsanleitung
Instruções de Instalação
K2W100
K2P100
K2C100
K2W200
K2P200
K2C200
Monitor Arm Series
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
K2 Series
K2 Series
Installation Instructions
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
IMPORTANT SAFETY INSTRUCTIONS!
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all components are
properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component. The wall to which the mount is being attached
may have a maximum drywall thickness of 5/8" (1.6cm).
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components located between the K2 Series Monitor Arm
up to (and including) the display does not exceed 40 lbs
(18.14 kg) for single arm mounts or 25 lbs (11.34 kg) per arm
on dual arm mounts. Use with products heavier than the
maximum weight indicated may result in collapse of the
mount and its accessories causing possible injury.
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
2
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Do not use this product outdoors.
--SAVE THESE INSTRUCTIONS!--
Installation Instructions
K2 Series
DIMENSIONS
K2C100
188.1
7.41
(8.85 [224.7] FOR
LOWER PROFILE INSTALL)
LOWER PROFILE INSTALL
EXTENSION
100
3.94
75
2.95
MAX 19.2 [487.7]
PITCH
TENSION
KNOB
PITCH
RANGE
15
90 INTERFACE
ROTATION
MANUAL HEIGHT
ADJUSTMENT RANGE
244.5
9.63
289.7
11.41
MAX 21.04 [534.2]
LOWER
PROFILE
CABLE
MANAGEMENT
HEIGHT
ADJUSTMENT
KNOB
DESKTOP
THICKNESS RANGE
12.7
.50
MAX 3.25 [82.6]
76.2
3.00
131.7
5.19
K2C200
MAXIMUM WIDTH OF 2 PARALLEL, FORWARD-FACING DISPLAYS: 28.8" [731.5]
EXTENSION
MIN 2.98 [75.7]
MAX 17.4 [450.7]
100
3.94
90 INTERFACE
ROTATION
75
2.95
PITCH
RANGE
15
PITCH
TENSION
KNOB
MANUAL HEIGHT
ADJUSTMENT RANGE
242.9
9.56
CABLE
MANAGEMENT
HEIGHT
ADJUSTMENT
KNOB
DESKTOP
THICKNESS RANGE
12.7
.50
MAX 3.25 [82.6]
291.3
11.47
MAX 21.04 [534.2]
76.2
3.00
133.3
5.25
3
Installation Instructions
K2 Series
DIMENSIONS (CONTINUED)
K2W100
100
3.94
75
2.95
90 INTERFACE
ROTATION
PITCH
RANGE
15
EXTENSION
MIN 2.98 [75.7]
MAX 17.2 [436.9]
PITCH
TENSION
KNOB
149.6
5.89
263.7
10.38
5.508
81.7
3.22
CABLE
MANAGEMENT
61.6
2.43
K2W200
MAXIMUM WIDTH OF 2 PARALLEL, FORWARD-FACING DISPLAYS: 28.25" [717.6]
100
3.94
75
2.95
90 INTERFACE
ROTATION
EXTENSION
MIN 2.98 [75.7]
MAX 17.2 [436.9]
PITCH
RANGE
15
PITCH
TENSION
KNOB
147.7
5.81
142.6
5.61
81.7
3.22
CABLE
MANAGEMENT
61.9
2.44
4
K2 Series
Installation Instructions
DIMENSIONS (CONTINUED)
K2P100
POLE CLAMP RANGE
1.50 [38.1] - 1.90 [48.3]
78.8
3.10
MAX EXTENSION 16.60 [421.6]
100
3.94
90 INTERFACE
ROTATION
75
2.95
PITCH
TENSION
KNOB
PITCH
RANGE
15
10.484
CABLE
MANAGEMENT
K2P200
POLE CLAMP RANGE
1.50 [38.1] - 1.90 [48.3]
MAXIMUM WIDTH OF 2 PARALLEL, FORWARD-FACING DISPLAYS: 28.25" [717.6]
EXTENSION RANGE
2.98 [75.7]
16.48 [418.5]
100
3.94
75
2.95
90 INTERFACE
ROTATION
PITCH
RANGE
15
10.58
CABLE
MANAGEMENT
5
PITCH
TENSION
KNOB
K2 Series
Installation Instructions
LEGEND
6
Tighten Fastener
Pencil Mark
Apretar elemento de fijación
Marcar con lápiz
Befestigungsteil festziehen
Stiftmarkierung
Apertar fixador
Marcar com lápis
Serrare il fissaggio
Segno a matita
Bevestiging vastdraaien
Potloodmerkteken
Serrez les fixations
Marquage au crayon
Loosen Fastener
Drill Hole
Aflojar elemento de fijación
Perforar
Befestigungsteil lösen
Bohrloch
Desapertar fixador
Fazer furo
Allentare il fissaggio
Praticare un foro
Bevestiging losdraaien
Gat boren
Desserrez les fixations
Percez un trou
Phillips Screwdriver
Adjust
Destornillador Phillips
Ajustar
Kreuzschlitzschraubendreher
Einstellen
Chave de fendas Phillips
Ajustar
Cacciavite a stella
Regolare
Kruiskopschroevendraaier
Afstellen
Tournevis à pointe cruciforme
Ajuster
Open-Ended Wrench
Remove
Llave de boca
Quitar
Gabelschlüssel
Entfernen
Chave de bocas
Remover
Chiave a punte aperte
Rimuovere
Steeksleutel
Verwijderen
Clé à fourche
Retirez
By Hand
Optional
A mano
Opcional
Von Hand
Optional
Com a mão
Opcional
A mano
Opzionale
Met de hand
Optie
À la main
En option
Hex-Head Wrench
Security Wrench
Llave de cabeza hexagonal
Llave de seguridad
Sechskantschlüssel
Sicherheitsschlüssel
Chave de cabeça sextavada
Chave de segurança
Chiave esagonale
Chiave di sicurezza
Zeskantsleutel
Veiligheidssleutel
Clé à tête hexagonale
Clé de sécurité
K2 Series
Installation Instructions
TOOLS REQUIRED FOR INSTALLATION
#2
3/16" (included)
5/32" (included with K1P Series only)
PARTS
A (1)
[monitor arm]
(K2W100 shown)
B (4 or 8)*
M4x14mm
C (4 or 8)*
M4x25mm
*8 screws and washers
included with dual arm mounts
D (4 or 8)*
M10x5.3x10
[included with K2W Series (wall mount) only!]
F (2)
1/4 x 2 1/2"
G (2)
1/4"
E (1)
[wall bracket]
[included with K2P Series (pole mount) only!]
H (1)
[pole clamp]
J (4)
1/4-20 x 1 1/2"
M (1)
3/16"
7
K (4)
1/4-20 x 1"
L (1)
5/32"
K2 Series
Installation Instructions
Assembly And Installation
IMPORTANT ! : IF you will be installing a SINGLE
display with RECESSED mounting holes, then proceed
to "DISPLAY INSTALLATION" before continuing with this
mount installation procedure.
1
Connecting K2C Series (column mount) to Desk
Standard Installation
1.
Loosen clamp screw until enough space is created between
clamp and mount to allow for desk mounting. (See Figure 1)
NOTE: If space is limited behind desk (i.e. against wall, etc.),
remove clamp screw and attachment entirely and
reattach clamp screw prior to Step 3! (See Figure 2)
2.
Place mount on top of desk at desired mounting location.
(See Figure 1)
3.
Tighten clamp using clamp screw until mount is securely
fastened to desk. (See Figure 1)
2
Figure 3
1
3
2
3.
Rotate mount in 90 degrees in either direction prior to
reinstalling onto column. (See Figure 4)
4.
Reinstall onto column and adjust to desired height. (See
Figure 4)
5.
Reinstall top cap to column. (See Figure 4)
desk
5
Figure 1
3
Figure 2
Low Profile Installation (KC2 Series Only)
1.
Remove top cap from column. (See Figure 3)
2.
Slide mount assembly off of column. (See Figure 3)
8
4
Figure 4
6.
Proceed with standard installation to desk as shown in
"Standard Installation" section.
K2 Series
Installation Instructions
(E)
set screw
6
3
3/16" x 2 1/2"
side view
5
4
(F) x 2
(E)
(G) x 2
Figure 5
Connecting K2W Series (wall mount) to Wall
1.
Determine mounting location on wall.
2.
Use a stud finder to locate stud.
3.
Use wall bracket to mark and drill two 3/16" x 2 1/2" holes in
wall at desired mounting location. (See Figure 5)
4.
Use two 1/4-2 1/2" hex head lag screws (F) and two 1/4"
washers (G) to install wall bracket onto wall. (See Figure 5)
3
(J or K) x 4
IMPORTANT ! : Overtightening screws (F) may cause
bracket to compress into soft wall surface resulting in
difficult mount installation or improper engaging of set
screw in Step 6.
(A)
5.
Hang monitor arm (A) over wall bracket. (See Figure 5)
6.
Secure monitor arm to wall bracket by tightening set screw.
Ensure set screw engages back side of wall bracket (E) to
properly secure mount. (See Figure 5)
Connecting K2P Series (pole mount) to Wall
1.
Determine approximate location for mount keeping in mind
display size, extension, height adjustment requirements.
2.
Place mount (A) against pole with clamp (H) on opposite
side of pole. (See Figure 6)
3.
Using 5/32" hex key (L) and appropriate length screws,
loosely attach K1P assembly to pole clamp (H). If installing
to 1 1/2" NPT pipe, use 1/4-20 x 1 1/2" button head cap
screws (J). If installing to 1 1/2" diameter pipe, use 1/4-20 x
1" button head cap screws (K). (See Figure 6)
4.
Position mount at desired height and orientation.
5.
Equally tighten screws against mount and the pole clamp.
(H)
Figure 6
9
K2 Series
Installation Instructions
Display Installation
Recessed Mounting Holes
The mounting holes on the back of the display will either be
flush with the back surface or recessed into the back surface.
Refer to the applicable installation procedure.
1.
Ensure Centris bracket is able to swivel and tilt easily, yet
still be tight enough to hold display in desired position.
Adjust as required before proceeding. See
"ADJUSTMENT" for detail.
Flush Mounting Holes
2.
Carefully place display face down on protective surface.
3.
Place the four spacers (D) over each of the mount holes on
the back of the display. (See Figure 8)
4.
Pick up and orient the mount (A) so that the mounting holes
are aligned with the holes in the spacers; rotate the bracket
as required. (See Figure 8)
5.
Using Phillips screwdriver, install four M4x25mm screws (C)
through the mounting holes, through the spacers and into
the display. (See Figure 8)
6.
Tighten all four screws. Do not overtighten!
CAUTION: Using screws of improper size may damage
your display! Proper screws will easily and completely thread
into display mounting holes.
CAUTION: Inadequate thread engagement in display may
cause display to fall! Back out screws ONLY as necessary to
allow installation of Centris bracket!
1.
Ensure faceplate is able to swivel and tilt easily, yet still be
tight enough to hold display in desired position. Adjust as
required before proceeding. See "ADJUSTMENT" for
detail. (See Figure 7)
2.
Using Phillips screwdriver, carefully install two M4x12mm
screws (B) into the upper mounting holes on the display.
Thread screws completely into display, then back out 3
complete turns. (See Figure 7)
3.
5
(C) x 4
Pick up and align display so that screws (B) (installed on the
back of the display in the previous step) fit into the mounting
holes on the faceplate. Rotate the bracket as required.
Lower the display firmly into place. (See Figure 7)
(A)
3 (D) x 4
2
3
Figure 8
Adjustments
Column Height Adjustment (K2C Series only)
4
1.
Loosen column adjustment knob. (See Figure 9)
2.
Adjust height to desired level. (See Figure 9)
3.
Tighten column adjustment knob. (See Figure 9)
1
2
Figure 7
4.
Using Phillips screwdriver, install two remaining M4x14mm
Phillips screws (B) through the lower mounting holes in
faceplate into the display. (See Figure 7)
5.
Tighten all four screws (B). Do not overtighten!
10
Figure 9
3
Installation Instructions
K2 Series
Pivot Adjustment Range
Swing Arm Pivot Adjustment
Single Arm Models (K2C100, K2W100 and K2P100)
1.
Adjust pivot position as desired. (See Figure 12)
1.
2.
Adjust pivot point tension screws to change pivot
adjustment tension. (See Figure 12)
Adjust arm angle as desired up to 90 degrees in either
direction. (See Figure 10)
WARNING: Swinging the arm beyond 90 degrees may
result in the mount slipping off the desk causing serious
injury!
edge of desk or wall face
(top view)
pivot point
tension
Figure 12
+/- 90 degrees range
of motion
Cable Management
1.
Route cables through cable management channels. (See
Figure 13)
1
Figure 10
Dual Arm Models (K2C200, K2W200 AND K2P200)
1.
Adjust arm angles as desired within a 90 degree range from
the edge of desk or wall and a perpendicular centerline of
mount. (See Figure 11)
cable (typical)
1
1
WARNING: Swinging the arm beyond this range may result
in the mount slipping of the desk causing serious injury!
(top view)
edge of desk or wall face
Figure 13
90 degrees range
of motion per arm
perpendicular centerline
Figure 11
11
K2 Series
Installation Instructions
USA/International
Europe
Chief Manufacturing, a products division
of Milestone AV Technologies
8800-002060 Rev 03
2011 Milestone AV Technologies, a
Duchossois Group Company
www.chiefmfg.com
12/11
Asia Pacific
A
P
F
A
P
F
A
8401 Eagle Creek Parkway, Savage, MN 55378
800.582.6480 / 952.894.6280
877.894.6918 / 952.894.6918
Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands
+31 (0)40 2668620
+31 (0)40 2668615
Office No. 1 on 12/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P 852 2145 4099
F 852 2145 4477