Procedure:
Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing. The fuse holder can be switched to one of two positions,
i.e. 230 V and 115 V.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
Should you have further questions, please contact your dealer.
8. TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
Inputs MIC 1-3:
Max. input level:
Inputs LINE 1-3:
Max. input level:
RETURN:
Outputs:
MASTER:
REC:
SEND:
Tone control:
High:
Bass:
Distortion:
S/N ratio:
Dimensions (WxDxH):
Weight:
115/230 V AC, 50/60 Hz ~
35 W
XLR/6.3 mm jack
-14 dB
stereo RCA
24 dB
6.3 mm stereo jack
6.3 mm stereo jack
stereo RCA
6.3 mm jack
-12 dB to +12 dB/ 10 kHz
-12 dB to +12 dB/ 100 Hz
0.025 %
69 dB
482 x 123 x 43 mm (19", 1 U)
2.2 kg