Download V600-series Electromagnetic FA ID System Characteristics

Transcript
V600-series Electromagnetic FA ID System
Characteristics
R/W Head and DC Characteristics
Superior Environmental Resistance
The DCs exceed IEC IP67 standards, so they can be used
in harsh operating environments. Besides withstanding water droplets, the DCs have excellent resistance to vibration
and shock. The R/W Heads also have superior environmental resistance for reliable operation in harsh conditions.
Built-in-battery Data Carriers
Ample Memory Capacity
A large RAM memory is built-in to store large amounts of
data. There will still be room for additional data after the
manufacturing data (such as the product model, production
number, manufacturing instructions, assembly instructions,
and destination) have been stored.
Replaceable-battery Data Carriers
Battery-less Data Carriers
Overwrite Data 100,000 times
Each memory address in the DC can be overwritten
100,000 times. Once written, data can be retained for 10
years.
Easily Replaceable Watch Batteries
are Used
Batteries can be replaced easily by removing the battery
cover with a coin. The CR2016 batteries are also readily
available.
Battery Life of 2 years with Unlimited
Memory Access
EEPROM Memory is Used
Non-volatile EEPROM memory is used, so a battery is not
required. A memory capacity of 256 bytes (254 usable bytes) is provided.
The battery life (at 25_C) is 2 years, regardless of the number of times data is transmitted. Since the battery life is unaffected by the number of read/write transmissions, this
type of DC is perfect for applications where memory must
be accessed often.
1
ID Controller Characteristics
Choose from 11 Models of ID
Controller to Match the Size and Style
of your FA ID System
ID Controllers are available that can connect to multi-purpose computers through a serial interface, while others can
connect to Programmable Controllers (PCs) through a Peripheral Interface, and ID Sensor Units can be mounted directly in an OMRON PC as Special I/O Units. Compact
hand-held versions are also available for easy maintenance at the work site. This wide selection allows you to
choose the best model to suit the size and style of your FA
ID system.
Direct Connection to OMRON PCs
ID Sensor Units (C500 and C200H Models) can be
mounted directly to OMRON’s C-series and CV-series PCs
as Special I/O Units. A long-distance-transmission C500
Sensor Unit is available which can cover a wide area from a
single PC. A R/W Head can be extended up to 200 m away
when an ID Adapter is used.
The Data Carriers can use either ASCII code or hexadecimal values, and all of the communications commands are in
ASCII code, so it is easy to control the FA ID System from
the PC program.
Serial Interface Connection
ID Controllers are available with RS-232C and RS-422 interfaces. The RS-232C interface allows connection to a
mainframe factory computer or personal computer and the
RS-422 interface allows up to 16 ID Controllers to be connected to a single computer. Up to 2K bytes of data can be
read or 256 bytes written at one time through a serial interface. Data can also be transmitted efficiently to two R/W
Heads using the independent polling autocommand.
Diagnostic Functions can prevent
system shutdowns.
The ID Controller monitors the status of communications
between the R/W Head and Data Carriers and outputs an
error code if an error occurs. The ID Controller can store
data on the 30 most recent errors or store statistical error
data. The error data can be read during daily maintenance
or if a transmission error shuts down the FA ID system.
Data can be read from V600-CAjA ID Controllers with a
Monitor Unit, from V600-CD1D ID Controllers with a host
command, and from ID Sensor Units with a Hand-held
Programming Console.
Peripheral Interface Connection
These ID Controllers are available with PNP and NPN outputs and are useful when you want a PC to have direct control over the ID Controller. The peripheral interface can be
also used to connect to most PCs, not just OMRON PCs.
2
System Configuration for Built-in-battery Data Carriers
Host System
Host Computer
Personal Computer
RS-232C
ID Controllers
RS-232C Interface
Machining Center
RS-422
RS-422 Interface
V600-CA1A
PC Bus
(Direct
Line)
Parallel I/O
Parallel PNP
Interface
PC (Programmable Controller)
Host System
not required.
ID Sensor Unit
(for PCs)
Hand-held ID
Controller
V600-CA8A
Parallel NPN
Interface
V600-CA2A
V600-CD1D-V2
V600-CA9A
C500IDS01
-V2
C200HIDS01V1
V600-CB-S
Cable Connection
(Snap-on Connectors)
R/W Heads
100 x 100 x 30 mm
53 x 40 x 23 mm
V600-H07
100 x 70 x 30 mm
V600-H11
Wireless transmission
V600-H06
Wireless
transmission
Wireless transmission
Data Carriers
86 x 54 x
20 mm
86 x 54 x
10.3 mm
65 x 40 x
15 mm
65 x 40 x
5 mm
V600-DjKR04 V600-DjKR13 V600-DjKR12 V600-DjKR16
(Replaceable
battery)
Note:
86 x 54 x
20 mm
86 x 54 x
10.3 mm
65 x 40 x
15 mm
V600-DjKR01 V600-DjKR03 V600-DjKR02
1. As of June 1, 1994, export of V600-H06 to the U.S. will be prohibited. Any of those products in use at that time can continue to be used.
2. The V600-H12 R/W Head and V600DjKR11 Data Carrier are available and are FCC-approved versions of the V600-H06 R/W Head and
V600-DjKR01 Data Carrier. There is no difference in the communication distance between the V600-H12 and V600-H11. We recommend the
V600-H11 or V600-H07. Contact your OMRON representative for details.
3
System Configuration for Battery-less Data Carriers
Host System
Host Computer
Personal Computer
RS-232C
ID Controllers
RS-232C Interface
Machining Center
RS-422
V600-CA1A
PC Bus
(Direct
Line)
Parallel I/O
RS-422 Interface
PC (Programmable Controller)
ID Sensor Unit
(for PCs)
Parallel PNP
Interface
Host System
not required.
Hand-held ID
Controller
V600-CA8A
Parallel NPN
Interface
C500IDS01
-V2
V600-CA2A
V600-CA9A
V600-CD1D-V2
C200HIDS01V1
V600-CB-S
Cable Connection
(Snap-on Connectors)
R/W Heads
100 x 100 x
30 mm
53 x 40 x
23 mm
M22 x 80 mm
M22 x 85 mm
Amplifier Section
Sensor Section
V600-H07
All conform to the
new FCC standards.
V600-H11
Wireless
transmission
V600-H51
Wireless
transmission
V600-H52
V600-HA51/HS51
V600-HA51/HS61
Wireless transmission
Data Carriers
86 x 54 x
1.5 mm
50 x 34 x
1.5 mm
V600-D23P71
V600-D23P72
36 x 24 x 6 mm
12 dia. x 6 mm
8 dia. x 5 mm
V600-D23P61
V600-D23P54
V600-D23P53
Note: The EEPROM Data Carriers can be used with the ID Controllers and ID Sensor Units listed below:
CA1A and CA2A ID Controllers with Version 5.0 or higher software; CD1D ID Controllers with Version 2.0 or higher software (CD1D-V2)
Hand-held ID Controllers with Version 2.0 or higher software; C200H-IDS01-V1, C500-IDS01-V2, and C500-IDS02-V1 ID Sensor Units
Specifications for Built-in-battery DCs
Built-in-battery Data Carriers
4
Item
Standard
Compact
Thin
Intermediate
Range
Compact with
Replaceable Battery
Model
V600-DjKR01
Memory Capacity
2K bytes/8K bytes
Memory type
SRAM
Transmission distance
Refer to page 6, Transmission Distance Specifications for Built-in-battery DCs
Battery life (see note)
Refer to page 6, Battery Life
2 years (at 25_C)
Number of reads/writes
Unlimited
Unlimited (Does not
affect battery life)
Transmission error
detection
16-bit CRC in both directions
Ambient temperature
Operating:
Storage:
–25° to 70°C
–40° to 70°C
Operating: 0° to 50°C
Storage: –15° to 70°C
Ambient humidity
Operating:
Storage:
35% to 95%
35% to 95%
Operating: 35% to 85%
Storage: 35% to 95%
Enclosure rating
IEC IP67
IEC IP50 (dustproof)
Vibration resistance
(destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y, and Z directions
10 to 150 Hz, 1.5-mm
double amplitude,
9.8m/s2 acceleration
(approx. 10G) for 30 min
each in X, Y, and Z
directions (90 min total)
Shock resistance
(destruction)
1,000 m/s2 (approx. 100G) 3 times each in X, Y, and Z directions
294 m/s2 (approx. 30G) 3
times each in X, Y, and Z
directions (18 times total)
Weight
Approx. 170 g
V600-DjKR02/
DjKR12
V600-DjKR03/
DjKR13
V600-DjKR04
V600-D2KR16
2K bytes
Approx. 70 g
Approx. 160 g
Approx. 15 g
Note: A low battery detection function is built-in.
Read/Write (R/W) Heads
Item
V600-H06
V600-H07
Transmission frequency
500 kHz
Ambient temperature
Operating:
Storage:
–25° to 70°C
–40° to 85°C
Ambient humidity
Operating:
Storage:
35% to 95%
35% to 95%
Insulation resistance
50 MΩ between cable terminals and case
Dielectric strength
500 VAC, 50/60 Hz for 1 min between cable terminals and case
Enclosure rating
IEC IP67
Vibration resistance
(destruction)
10 to 55 Hz 1.5-mm double amplitude for 2 hrs each in X, Y, and Z
directions
Shock resistance
Destruction: 490 m/s2 (approx. 50G) 3 times each in X, Y, and Z directions
Cable length (see note)
Standard lengths of 0.5 m, 2 m, 5 m, and 10 m
Wireless transmission
error detection
16-bit CRC in both directions
Indicators
Power: red
Power: green; transmission: orange
Weight
Approx. 1 kg (with 10-m cable)
Approx. 1.1 kg (with 10-m cable)
V600-H11
530 kHz
Operating:
Storage:
–10° to 60°C
–25° to 75°C
1,000 VAC, 50/60 Hz for 1 min
between cable terminals and case
10 to 500 Hz, 2.0-mm double
amplitude for 30 min each in X, Y,
and Z directions
Approx. 650 g (with 10-m cable)
Note: Extension cables are also available. The maximum cable length is 30.5 m for the V600-H06/H07 and 50.5 m for the V600-H11.
5
Battery Life
(Minimum life in the –10_C to 55_C temperature range)
The following graphs show the relationship between the number of bytes read/written and the battery life.
Bytes per transmission
8 yrs
Bytes per transmission
5 yrs
8 yrs
V600-DjKR04 (Reference)
Transmissions/day (x 100)
5 yrs
V600-DjKR03 (Reference)
Transmissions/day (x 100)
5 yrs
8 yrs
V600-DjKR02 (Reference)
Transmissions/day (x 100)
Transmissions/day (x 100)
V600-DjKR01(-T) (Reference)
Bytes per transmission
5 yrs
8 yrs
Bytes per transmission
Transmission Distance Specifications for Built-in-battery DCs
Refer to the section on installation in the Data Carrier or R/W Head’s Operation Manual or Supplement for more details.
Recommended combinations
Data Carrier
V600-DjKR04
(non-shielded
type)
(non
shielded ty
e)
Installation
V600-H07
Stationary
Moving
V600-H11
Stationary
Moving
V600-DjKR13
V600-H07
Stationary
Moving
V600-H11
Stationary
Moving
V600-DjKR12
V600-H07
Stationary
Moving
6
Controller mode
Transmission distance
R/W Head
Flush-mounted in
metal
Irrelevant
(see note )
Surface-mounted on
metal
10 to 100 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
(see note )
Surface-mounted on
metal
50 to 100 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
Irrelevant
10 to 45 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
10 to 65 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
30 to 45 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
30 to 65 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
Irrelevant
10 to 30 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
10 to 35 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
20 to 30 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
20 to 35 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
Irrelevant
10 to 30 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
10 to 30 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
15 to 30 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
15 to 30 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
Irrelevant
10 to 50 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
10 to 60 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
25 to 50 mm (max. axial offset ±10 mm)
Recommended combinations
Installation
Controller mode
Transmission distance
R/W Head
Data Carrier
25 to 60 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
V600-H11
V600-DjKR12
Stationary
Moving
V600-H11
V600-DjKR16
Stationary
Flush-mounted in
metal
Irrelevant
Surface-mounted on
metal
5 to 45 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
25 to 40 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
25 to 45 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
Irrelevant
V600-H06
Stationary
Moving
Stationary
V600-DjKR03
Moving
Stationary
V600-DjKR02
Moving
2 to 15 mm (max. axial offset ±10 mm)
8 to 15 mm (max. axial offset ±10 mm)
Moving
V600-DjKR01
5 to 40 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
Irrelevant
10 to 35 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
15 to 40 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
20 to 35 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
25 to 40 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
Irrelevant
10 to 35 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
15 to 40 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
20 to 35 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
25 to 40 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
Irrelevant
5 to 25 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
10 to 30 mm (max. axial offset ±10 mm)
Flush-mounted in
metal
15 to 25 mm (max. axial offset ±10 mm)
Surface-mounted on
metal
20 to 30 mm (max. axial offset ±10 mm)
Note: When a V600-DjKR04 is flush-mounted in metal, the
read/write distance depends on the distance (x) between
the side of the DC and the metal surface.
x mm Flush-mounted x mm
in metal
20 mm max.
All metal
Conditions for DC Installation
V600-DjKR04
V600-DjKR12/
DjKR13
Surface-mounted on metal
All metal
V600-DjKR16
Surface-mounted on metal
V600-DjKR01/DjKR02/
DjKR03
Surface-mounted on metal
All metal
All metal
All metal
Data
Carrier
Flush-mounted in metal
All metal
Note:
Flush-mounted in metal
All metal
The listed specifications are also valid when the DC is surface-mounted on a material other than metal.
7
Specifications for Battery-less DCs
Built-in-battery Data Carriers
Item
Round
Super-compact
Round Compact
V600-D23P54
Rectangular
Compact
V600-D23P61
Card-type
Model
V600-D32P53
Memory Capacity
256 bytes
Memory type
EEPROM (non-volatile memory)
Transmission distance
Refer to page 9, Transmission Distance Specifications for Battery-less DCs
Data retention time
10 years (Data is retained for 10 years after it is written)
Number of overwrites
Each address can be overwritten 300,000 times at an ambient temperature of 40°C max. or 100,000 times at an
ambient temperature of 40°C min.; The number of reads is unlimited
Transmission error
detection
16-bit CRC in both directions
Ambient temperature
Operating:
Storage:
Ambient Humidity
Operating: 35% to 95%
Enclosure rating
IEC IP67, JEM IP67G
Vibration resistance
(destruction)
10 to 2,000 Hz, 1.5-mm single amplitude, with 2 sweeps of 15 min each in 3 directions
Shock resistance
Destruction: 981 m/s2 (approx. 100G) 3 times each in 3 directions (18 times total)
Weight
Approx. 0.4 g
–25° to 70°C
–40° to 85°C (including data storage)
Approx. 1.0 g
V600-D23P71
Half-size Card-type
Operating:
Storage:
Approx. 5.8 g
Approx. 15 g
V600-D23P72
–10° to 70°C
–20° to 110°C
10 to 2,000 Hz,
1.5-mm double
amplitude, 29.4 m/s2
acceleration (approx.
10G) for 30 min each
in 3 direction (90 min
total)
Approx. 5 g
Read/Write (R/W) Heads
Item
V600-H07
V600-H11
V600-H51
Transmission frequency
530 kHz
Ambient temperature
Operating:
Storage:
–25° to 70°C
–40° to 85°C
Ambient humidity
Operating:
Storage:
35% to 95%
35% to 95%
Insulation resistance
50 MΩ between cable terminals and case
Dielectric strength
500 VAC, 50/60 Hz for 1 min
between cable terminals and
case
Enclosure rating
IEC IP67
Vibration resistance
(destruction)
10 to 55 Hz 1.5-mm double
amplitude for 2 hrs each in X,
Y, and Z directions
Shock resistance
Destruction: 490 m/s2 (approx. 50G) 3 times each in X, Y, and Z directions
Cable length (see note)
Standard lengths of 0.5 m, 2 m, 5 m, and 10 m.
Wireless transmission
error detection
16-bit CRC in both directions
Indicators
Power: green; transmission: orange
Weight
Approx. 1.1 kg (with 10-m
cable)
Operating:
Storage:
V600-H52
–10° to 60°C
–25° to 75°C
1,000 VAC, 50/60 Hz for 1 min between cable terminals and case
10 to 500 Hz, 2.0-mm
double amplitude for
30 min each in X, Y, and Z
directions
10 to 500 Hz, 2.0-mm double amplitude, with 3 sweeps
of 11 min each in X, Y, and Z directions
Approx. 650 g (with 10-m cable)
Note: Extension cables are also available. The maximum cable length is 30.5 m for the V600-H07 and 50.5 m for the
V600-H11/H51/H52.
8
R/W Heads (with Separate Amplifier)
Item
Sensor section
V600-HS51
Amplifier section
V600-HS61
V600-HA51
Transmission frequency
530 kHz
Ambient temperature
Operating:
Storage:
–10° to 60°C
–25° to 75°C
---
Ambient humidity
Operating:
35% to 95%
Insulation resistance
50 MΩ between cable terminals and case
Dielectric strength
1,000 VAC 50/60 Hz for 1 min between cable terminals and case
Enclosure rating
IEC IP67, JEM IP67G
IEC IP66
Vibration resistance
(destruction)
10 to 2,000 Hz, 1.5-mm double amplitude, with 2 sweeps of 15 min each in
3 directions
Installed in panel: 10 to 2,000 Hz,
1.5-mm single amplitude, with
2 sweeps of 15 min each in
3 directions
Operating:
Storage:
–10° to 60°C
–25° to 75°C
DIN Track installation: 10 to 500 Hz,
1.0-mm single amplitude, with
3 sweeps of 11 min each in
3 directions
Shock resistance
(destruction)
981 m/s2 (approx. 100G) 3 times each in 3 directions (18 times total)
490 m/s2 (approx. 50G) 3 times each
in 3 directions (18 times total)
Cable length
2 m (fixed) between sensor and amplifier
Standard lengths of 2 m, 5 m, and
10 m between amplifier and
controller (see note)
Wireless transmission
error detection
16-bit CRC in both directions
Indicators
---
Power: green; transmission: orange
Weight
Approx. 70 g (with 2-m cable)
Approx. 650 g (10-m cable)
Note: Extension cables are also available. The maximum cable length is 50 m for the V600-HA51.
Transmission Distance Specifications for Battery-less DCs
Recommended combinations
Data Carrier
V600-D23P71
Installation
Controller mode
V600-H07
Stationary
Read/Write
distance
Irrelevant
V600-H11
Stationary
Read/Write
distance
Irrelevant
Stationary
Read/Write
distance
Irrelevant
Stationary
Moving
10 to 50 mm (max. axial offset ±10 mm)
25 to 40 mm (max. axial offset ±10 mm)
Moving
V600-H51
5 to 35 mm (max. axial offset ±10 mm)
15 to 35 mm (max. axial offset ±10 mm)
Moving
V600-H07
10 to 70 mm (max. axial offset ±10 mm)
30 to 60 mm (max. axial offset ±10 mm)
Moving
V600-D23P72
Transmission distance
R/W Head
Read/Write
distance
Irrelevant
2 to 25 mm (max. axial offset ±10 mm)
10 to 25 mm (max. axial offset ±10 mm)
9
Recommended combinations
Data Carrier
V600-D23P61
Installation
V600-H51
Stationary
Moving
V600-H11
Stationary
Moving
V600-D23P53
V600-HS51
V600-HS61
V600-H52
V600-D23P54
V600-HS51
V600-HS61
V600-H52
Transmission distance
Stationary
Stationary
Stationary
Stationary
Stationary
Stationary
Transmission
distance priority
1 to 16 mm (max. axial offset ±2 mm)
Transmission
time priority
1 to 14 mm (max. axial offset ±2 mm)
Write distance
Irrelevant
1 to 14 mm (max. axial offset ±2 mm)
Read distance
Transmission
distance priority
7 to 16 mm (max. axial offset ±2 mm)
Transmission
time priority
7 to 14 mm (max. axial offset ±2 mm)
Write distance
Irrelevant
7 to 14 mm (max. axial offset ±2 mm)
Read distance
Transmission
distance priority
2 to 19 mm (max. axial offset ±10 mm)
Transmission
time priority
2 to 16 mm (max. axial offset ±10 mm)
Write distance
Irrelevant
2 to 16 mm (max. axial offset ±10 mm)
Read distance
Transmission
distance priority
12 to 19 mm (max. axial offset ±10 mm)
Transmission
time priority
12 to 16 mm (max. axial offset ±10 mm)
Write distance
Irrelevant
12 to 16 mm (max. axial offset ±10 mm)
Read distance
Transmission
distance priority
0.5 to 4.0 mm (max.
axial offset ±2 mm)
0.5 to 4.5 mm (max.
axial offset ±1 mm)
Transmission
time priority
0.5 to 3.0 mm (max.
axial offset ±2 mm)
0.5 to 3.5 mm (max.
axial offset ±1 mm)
Write distance
Irrelevant
0.5 to 3.0 mm (max.
axial offset ±2 mm)
0.5 to 3.5 mm (max.
axial offset ±1 mm)
Read distance
Transmission
distance priority
0.5 to 4.0 mm (max.
axial offset ±2 mm)
0.5 to 4.5 mm (max.
axial offset ±1 mm)
Transmission
time priority
0.5 to 3.0 mm (max.
axial offset ±2 mm)
0.5 to 3.5 mm (max.
axial offset ±1 mm)
Write distance
Irrelevant
0.5 to 3.0 mm (max.
axial offset ±2 mm)
0.5 to 3.5 mm (max.
axial offset ±1 mm)
Read distance
Transmission
distance priority
0.5 to 4.0 mm (max.
axial offset ±2 mm)
0.5 to 4.5 mm (max.
axial offset ±1 mm)
Transmission
time priority
0.5 to 3.0 mm (max.
axial offset ±2 mm)
0.5 to 3.5 mm (max.
axial offset ±1 mm)
Write distance
Irrelevant
0.5 to 3.0 mm (max.
axial offset ±2 mm)
0.5 to 3.5 mm (max.
axial offset ±1 mm)
Read distance
Transmission
distance priority
0.5 to 6.0 mm (max.
axial offset ±2 mm)
0.5 to 6.5 mm (max.
axial offset ±1 mm)
Transmission
time priority
0.5 to 5.5 mm (max.
axial offset ±2 mm)
0.5 to 6.0 mm (max.
axial offset ±1 mm)
Write distance
Irrelevant
0.5 to 5.0 mm (max.
axial offset ±2 mm)
0.5 to 5.5 mm (max.
axial offset ±1 mm)
Read distance
Transmission
distance priority
0.5 to 6.5 mm (max.
axial offset ±2 mm)
0.5 to 7.0 mm (max.
axial offset ±1 mm)
Transmission
time priority
0.5 to 5.5 mm (max.
axial offset ±2 mm)
0.5 to 6.0 mm (max.
axial offset ±1 mm)
Write distance
Irrelevant
0.5 to 5.5 mm (max.
axial offset ±2 mm)
0.5 to 6.0 mm (max.
axial offset ±1 mm)
Read distance
Transmission
distance priority
0.5 to 6.5 mm (max.
axial offset ±2 mm)
0.5 to 7.0 mm (max.
axial offset ±1 mm)
Transmission
time priority
0.5 to 5.5 mm (max.
axial offset ±2 mm)
0.5 to 6.0 mm (max.
axial offset ±1 mm)
Irrelevant
0.5 to 5.5 mm (max.
axial offset ±2 mm)
0.5 to 6.0 mm (max.
axial offset ±1 mm)
Read distance
Write distance
10
Controller mode
R/W Head
Note: 1. The transmission distance/transmission time priority mode setting can be made only with the lower-level communications
mode setting switch with a serial-interface Controller or ID Sensor Unit. With parallel-interface Controllers, the mode setting is
always transmission distance priority.
2. With Data Carriers that can be installed on metal surfaces (V600-D23P61/D23P53/D23P54), the transmission distance will
vary depending on the metal used. The figures given in the table above are valid for iron (SC, SS). Refer to the section on
installation in the Data Carrier or R/W Head’s Operation Manual or Supplement for more details.
Conditions for DC and R/W Head Installation
V600-D23P71/D23P72
V600-D23P61
These Data Carriers are for
installation on non-metallic
surfaces only.
These Data Carriers can be
installed on all surfaces.
V600-H07/11/51
R/W Head
V600-D23P53/D23P54
V600-D23P61
Data Carrier
V600-D23P71/D23P72
Data Carrier
These Data Carriers are for
installed in metallic only.
V600-D23P53/D23P54
Data Carrier
V600-HS61
R/W Head
V600-H51
R/W Head
Iron
Iron
Non-metallic
(Plastic, wood, etc.)
Note:
Data transmission will be impossible if the DC is installed directly
on a metal surface. The transmission distances will be reduced to 70% of the listed figures
if the DC is 10 mm from the metal
surface, and 90% of the listed figures if the DC is 20 mm from the
metal surface.
Refer to the section on installation in the Data Carrier or R/W
Head’s Operation Manual or
Supplement for more details.
Iron
V600-H11
R/W Head
Iron (SC, SS)
Iron (SC, SS)
V600-D23P53/D23P54
Data Carrier
V600-D23P61
Data Carrier
V600-HS51
R/W Head
Iron
Iron
Iron (SC, SS)
Note:
Iron (SC, SS)
V600-D23P53/D23P54
Data Carrier
The listed transmission distances
apply for installation on metallic
and non-metallic surfaces.
V600-HS52
R/W Head
Iron
Note:
Iron (SC, SS)
The listed transmission distances
apply for installation on metallic
and non-metallic surfaces.
Transmission Range Graphs (Examples)
Built-in-battery DCs
V600-DjKR04 & V600-H07
V600-DjKR13 & V600-H07
V600-DjKR12 & V600-H07
V600-DjKR04 & V600-H11
V600-DjKR13 & V600-H11
V600-DjKR12 & V600-H11
11
Note: For DCs with RAM, the read distance is the same as the write distance. These examples are for DCs installed on metal.
Battery-replaceable DCs
V600-D2KR16 & V600-H11
Note: Changing the direction of the DC will change the
transmission range.
Battery-less Compact DCs
V600-D23P53 & V600-H52
V600-D23P54 & V600-H52
V600-D23P61 & V600-H51
V600-D23P61 & V600-H11
Read range (in transmission distance priority mode)
Write range (in transmission distance or transmission time priority mode)
Read range (in transmission time priority mode)
Card-type DCs
V600-D23P71 & V600-H07
V600-D23P72 & V600-H07
V600-D23P72 & V600-H11
Note: Changing the direction of the DC will change the transmission range.
Transmission Time Specifications
The transmission time does not depend on the model of R/W Head or Data Carrier, although transmission times differ between Data
Carriers with and without batteries.
The turn around time (TAT) is the total time required from the issuance of a command from the host device (for example, a host computer)
until the reception of a response.
The lower-level communications time does not include the host communications; it is the time required for communications between the
R/W Head and Data Carrier. The lower-level communications time is used in the equation for the DC speed.
DC Speed = (Distance travelled in the transmission range)/(Lower-level communications time)
12
r
RDH1
Command
r
RD001122
Response
Lower-level
communications time
TAT (Turn Around Time)
Lower-level communications time (ms)
Built-in-battery Data Carriers
Calculation
Controller/Item
(Auto) Write
Serial-interface
used
Lower-level
communications
time
TAT
READ
T = 1.8N + 48.4
T = 3.0N + 55.9
WRITE
T = 4.2N + 86.5
T = 4.2N + 94.1
Note: 1. The TAT figures are for a V600-CA1A ID Controller and
host communications set for 9600 bps, 8 data bits, 1
stop bit, and odd parity. Transmission is continuous
without spaces between characters.
(Auto) Read
Number of bytes
Note:
R/W
The Parallel-interface Controllers and ID Sensor
Units will change according to the host software.
2. N is the number of bytes when the code is set to ASCII
code. (Refer to the Controller’s Operation Manual for
details.)
Lower-level communications time (ms)
Battery-less Data Carriers
Calculation (Reference)
Transmission distance priority mode
Transmission time priority mode
Controller
R/W
(Auto) Write
Distance priority
mode
(Auto) Read
Number of bytes
Time priority
mode
Lower-level
communications
time
TAT
READ
T = 4.3N + 64.6
T = 5.6N + 72.2
WRITE
T = 8.7N + 167.1
T = 8.7N + 174.6
READ
T = 1.8N + 79.0
T = 3.1N + 86.6
WRITE
T = 7.1N + 180.4
T = 7.1N + 187.8
Note: Except for the TAT data constants, the built-in-battery DCs
are the same.
Lower-level Communications Mode Setting (Distance/Time Priority)
These settings are valid only with Battery-less DCs. The lower-level communications mode setting is made on a DIP Switch on the Serialinterface Controller (V600-CA1A/CA2A/CF1A, or V600-CD1D-V2) or ID Sensor Unit. (Refer to the Controller’s Operation Manual for
more details on this setting.)
With Parallel-interface Controllers (V600-CA8A/CA9A) the mode is fixed to transmission distance priority. With built-in-battery DCs,
there is no mode distinction, so either setting can be made.
13
V600-CAjA (2 R/W Head Connections)
ID Controller (with AC Power Supply)
Superior Diagnostic Functions
In addition to checking hardware during operation, the ID Controller monitors the status of communications between the R/W Head
and Data Carriers. Data on the 30 most recent transmission errors
is stored. The error data can be read in two ways; information on
the most recent error can be read or statistical information on all of
the errors can be read. Any errors that occur can be corrected
quickly, minimizing the time that the FA ID system is down.
The data can be stored for up to 20 days (at 25_C) in internal
memory after a power interruption.
Up to 2 R/W Heads can be connected to the ID Controller. ID Controllers are available with either parallel or serial interfaces for connection to the host device. All data reading and writing operations
take place according to commands issued by the host computer or
PC.
V600-CD1D-V2 (1 R/W Head Connection)
ID Controller (with DC Power Supply)
Numerous I/O
Equipped with synchronous input, processing complete output,
and control I/O.
Monitoring Functions
Two 7-segment LED displays are built into the ID Controller to display error codes, completion codes, and the status of I/O points.
• Output Specifications (RUN, CMPL, OUT1, OUT2)
Item
• Diagnostics
Item
Diagnostic functions
Specification
Checks for CPU errors, memory errors,
power interruptions, and transmission errors
Space-saving Design
The ID Controller dimensions have been reduced to 115×68×80
mm (D×W×H). The connector section has been lowered to eliminate wasted space.
• Input Specifications (RESET, TRIG, IN1, IN2)
Item
Specification
Input voltage
24 VDC +10%/–15% (including ripple)
Input impedance
2.2 kΩ
Input current
10 mA TYP. (24 VDC)
ON voltage
19 V min.
OFF voltage
5 V max.
Input response time
70 ms max.
14
Specification
Maximum switching
capacity
100 mA, 24 VDC +10%/–15% (including
ripple)
Leakage current
100 µA max.
Residual voltage
2.0 V max.
Note: 1. When the RESET input is ON, CPU operation is
stopped and the STOP indicator is lit. The RUN output is
reset at this time.
2. An output’s transistor might fail if the output is short-circuited without a load.
V600-CB-US-S/S1
• Battery Charger (V600-A14)
Hand-held ID Controller
Item
The Hand-held ID Controller is a portable Unit that is convenient
for onsite use.
The Unit is battery powered, so it can be taken anywhere to transfer data to and from Data Carriers.
Memory Capacity
The Unit is equipped with 32K-bytes of RAM, so it can contain as
many as 64 memories (0.5K-bytes/memory) or as large as 16Kbyte memories (2 memories) of data.
Data or long commands that are used often (during initialization of
Data Carriers, for example) can be converted to memory and then
accessed later by specifying the corresponding memory number.
Specification
Power supply
voltage
115 VAC, 50/60 Hz
Acceptable power
supply voltage
85 to 110 VAC, 50/60 Hz
Charging time
8 hrs (There is a built-in overcharge
protection circuit)
Weight
Approx. 400 g
• V600-CB-US-S/S1 Configuration
Model
V600-CB-US-S
V600-CB-US
V600-A11
V600-A12
V600-A13
Yes
V600-A14
Yes
V600-CB-US-S1
No
ID Controller Specifications
ID Controllers
Item
V600 Series (Electromagnetic FA ID System)
V600-CA1A
V600-CA2A
RS-422
V600-CA8A
V600-CA9A
Parallel PNP output
Parallel NPN output
V600-CD1D-V2
Host interface
RS-232C
Possible number of R/W
Heads
2
RS-232C
1
Power supply voltage
100 to 240 VAC, 50/60 Hz
24 VDC
Acceptable power supply
voltage
85 to 264 VAC
20.4 to 26.4 VDC
Power consumption
35 VA max.
7.2 W max.
Insulation resistance
50 MΩ min. between power terminals and case, between I/O terminals and case, or between the power supply
terminals and I/O terminals
Dielectric strength
1,500 VAC, 50/60 Hz for 1 min between the points listed above;
Leakage current: 10 mA max.
Noise immunity
1,500 V (p-p) pulses of 100 ns to 1 µs pulse width with a 1 ns rise time
Vibration resistance
Destruction:
Malfunction:
Shock resistance
Destruction: 200 m/s2 (approx. 20G) 3 times each in X, Y, and Z directions
Ambient temperature
Operating: –10° to 55°C
Storage: –25° to 65°C
Ambient humidity
35% to 85% (with no condensation)
Operating conditions
No corrosive gases
Memory back-up
A capacitor backs up the most recent error data and statistical error data for up to 20 days
(at 25_C) after a power interruption
Diagnostic functions
Checks for CPU errors, memory errors, power interruptions, and transmission errors
Ground
Ground to 100 Ω or less.
Construction
For inter-panel installation (IP30)
Weight
Approx. 890 g
1,000 VAC, 50/60 Hz
for 1 min between the
points listed above;
Leakage current:
10 mA max.
10 to 150 Hz, 0.3-mm double amplitude for 32 min each in X, Y, and Z directions
10 to 150 Hz, 0.2-mm double amplitude for 32 min each in X, Y, and Z directions
Approx. 930 g
Approx. 960 g
Memory is not backed
up, but error
information can be
read from a host
computer at start-up
Approx. 360 g
15
Hand-held ID Controller
Item
V600-CB-US
Power supply
Built-in nickel-cadmium batteries (6 VDC) or 9-V alkaline batteries (9 VDC)
Power consumption
700 mA max.
Continuous operating time (see note)
3 hrs min. when using the built-in nickel-cadmium batteries;
1.5 hrs min. when using the alkaline batteries
Automatic power-saver
The power is turned off automatically if a key input or response is not received in 10 min
Automatic command cancellation
A command will be cancelled automatically if a response is not received from a Data Carrier within
2 min
Low battery indicator
This display appears when the battery voltage falls below the minimum voltage required for operation
User memory
32K bytes (Data will be retained for at least 24 hrs after batteries are removed)
Vibration resistance
Destruction: 10 to 150 Hz, 0.15-mm single amplitude for 8 min each in X, Y, and Z directions
Shock resistance
Destruction: 200 m/s2 (approx. 20G) 3 times each in X, Y, and Z directions
Ambient temperature
Operating: 0° to 45°C
Storage: –20° to +60°C (excluding the battery pack)
Ambient humidity
Operating: 35% to 85%
Operating conditions
No corrosive gases
Construction
IEC IP30
Weight
680 g max. (including the battery pack)
Note: The continuous operating time is for new, fully charged nickel cadmium batteries or new alkaline batteries used at room temperature.
Monitor Unit
V600-P01 (for use with V600-CAjA Controllers)
The Monitor Unit is a monitoring device that can be mounted to an ID Controller. It can be used to test communications between the R/W
Head and Data Carrier when the FA ID System is started up, check the data in Data Carriers, and read error information or statistical error
information.
The specifications conform to those of the ID Controller, except the operating temperature range is 0_C to 40_C.
16
SYSMAC ID Sensor Units
V600 Series (Electromagnetic FA ID System)
Wide Variety of Applications
ID Sensor Units (C500 and C200H models) can be mounted directly to OMRON’s C-series and CV-series PCs (C200H,
C200HS, C500, C1000H, C2000H, CV500, and CV1000 PCs) as
Special I/O Units. A long-distance-transmission C500 Sensor Unit
is available which can cover a wide area from a single PC. A R/W
Head can be extended up to 200 m away when an ID Adapter is
used.
Monitoring Operation with a Hand-held Programming Console
The C200H-PRO27-E Hand-held Programming Console can be
connected to the ID Sensor Unit for use as a monitoring device.
Attach the special keysheet (an ID Sensor Unit accessory) to the
Programming Console when it is used to monitor ID Sensor Unit
operation.
Superior Diagnostic Functions
Like ID Controllers, the ID Sensor Units can monitor the status of
communications between the R/W Head and Data Carriers and
store data on the 30 most recent transmission errors. The error
data can be read using a Hand-held Programming Console.
Unified PC Programming
It is easy to control the FA ID System from the PC program, which
eliminates the need for an independent program for the ID Sensor
Unit.
C500-IDS01-V2
C500-IDS02-V1
Connecting Cable
C200H-CN222 (2 m)
C200H-CN422 (4 m)
Keysheet (ID Sensor
Unit accessory)
C200H-IDS01-V1
C200H-PRO27-E
Hand-held Programming
Console
17
System Configuration
There are 3 ID Sensor Unit models, one version for the C200H and C200HS, and two versions for the other C-series and CV-series PCs.
A Host Link Unit, SYSMAC LINK Unit, or SYSMAC NET Link Unit can also be mounted to construct a Host Link System, SYSMAC LINK
System, or SYSMAC NET Link System.
R/W Head
Data Carrier
C500-IDS01-V2
ID Sensor Unit
(for general use)
R/W Head
SYSMAC C500,
C1000H, C2000H,
CV500, CV1000,
CVM1 PCs
C500-IDS02-V1
ID Sensor Unit
(for long-distance
transmission)
C500-IDA02
ID Adapter
200 m max.
Data Carrier
R/W Head
Data Carrier
C200H-IDS01-V1
ID Sensor Unit
SYSMAC C200H,
C200HS PCs
High-speed Data Transfer
Most PC CPUs are equipped with the Intelligent I/O Read and Intelligent I/O Write instructions (READ and WRIT) which can be
used to transfer up to 502 bytes of data (251 words) at high-speed
between the ID Sensor Unit and PC. These instructions cannot be
used if the ID Sensor Unit is mounted to a Slave Rack. If the Intelligent I/O instructions are used, 2 words will be allocated to the ID
Sensor Unit, if these instructions are not used, 4 words will be allocated.
SYSMAC C500, C1000H,
C2000H, CV500, CV1000,
must be attached toCVM1
the Programming
Console for use
PCs
with the ID Sensor Unit.
2. Use the special connectorR/W
included
extension
Head with
Datathe
Carrier
cable when connecting the extension cable. Refer to the
directions in the manual for details.
C500-IDS01-V2 (V600-series)
ID Sensor Unit (for general use)
Long-distance Transmission (C500-IDS02-V1)
The C500-IDS02-V1 ID Sensor Unit is very useful for long production lines, since the distance to the R/W Heads can be extended up
to 200 m. This ID Sensor Unit is always used together with the
C500-IDA02 ID Adapter.
C500-IDS02-V1
(V600-series) ID Sensor
Unit (for long-distance
transmission)
C500-IDA02
(V600-series)
ID Adapter
ASCII Unit
ID Sensor Unit
Connecting Cable
C200H-CN222 (2 m)
C200H-CN422 (4 m)
Note: 1. The special keysheet (an ID Sensor Unit accessory)
Keysheet
(see note 1)
C200H-PRO27-E
Hand-held
Programming
Console
Messages contained in the Data
Carrier can be displayed using a Display Terminal Unit, so production information can be monitored as it is
generated at the production site.
18
Data
Carrier
200 m max.
(see note)
ID Adapter
A C500-IDA02 ID Adapter is always required when a long-distance C500-IDS02-V1 ID Sensor Unit is used. The ID Adapter can
be mounted to a C500 Rack; in this case, the ID Adapter will not
consume the Rack’s 5 VDC power and it will not be allocated I/O
words. The ID Adapter can be operated as a stand-alone Unit if it is
supplied with 24 VDC power (450 mA min.).
R/W
Head
Display Terminal Unit
C200H-IDS01-V1 ID Sensor Unit
The C200H-IDS01-V1 ID Sensor Unit is treated as a Special I/O
Unit, so it can be mounted on a C200H or C200HS CPU Rack, Expansion I/O Rack, or Slave Rack. There are some limitations on
the installation of Special I/O Units; for example, a maximum of 10
Units can be connected to one CPU.
Note: Refer to PC’s Installation Guide for more details.
Communications with the C200H/C200HS
The C200H-IDS01-V1 can read or write up to 1024 bytes (512
words) of data, however, the C200H/C200HS CPUs can take in
only 20 words/cycle.
SYSMAC
C200H, C200HS
PCs
R/W
Data
Head
Carrier
Connecting Cable
C200H-CN222
C200H-CN422
C200H-IDS01-V1
(V600-series)
ID Sensor Unit
C200H-PRO27-E
Hand-held Programming
Console
Keysheet
ID Sensor Unit Specifications
Item
C500-IDS01-V2 (for general use)
C500-IDS02-V1 (for long-distance transmission)
C200H-IDS01-V1
Communications control
Dedicated time sharing
Possible number of R/W Heads
1 R/W Head
Compatible Data Carriers
2K-byte and 8K-byte RAM DCs (with battery), 256-byte EEPROM DCs (without battery)
DC memory format
8-bit dedicated format
Commands
The following 7 commands are used: Read, Write, Auto read, Auto write, Abort, Cancel auto-command,
Data management processing
Transmission capacity
Up to 502 bytes (201 words) of data can be
batch-transferred using the Intelligent I/O
instructions (READ/WRIT)
Diagnostic functions
1. CPU watchdog timer
2. Detects transmission error with DC, absence of DC
3. Error log function, records transmission errors (with capacitor back-up)
Monitoring functions
A Hand-held Programming Console (with a special keysheet) can be used to monitor operation (max.
cable length: 4 m). The following operations are possible: Read 1-byte, Write 1-byte, Continuous write,
Test, and Monitor error log
Memory back-up
The error information has a capacitor back-up. Data retained at least 15 days (at 25_C).
I/O word allocation
Two words are allocated when the Intelligent I/O
instructions (READ/WRIT) are used
Four words are allocated when the Intelligent I/O
instructions (READ/WRIT) are not used
(selectable)
Five words are allocated within the Special I/O (IR)
area (IR 100 to IR 199)
External power supply
250 mA min. at 24 VDC
---
Internal current consumption
400 mA max. at 5 VDC
250 mA max. at 5 VDC
120 mA max. at 26 VDC
(to drive the R/W Head) (see note)
Weight
700 g max.
400 g max.
Dimensions
34.5 × 250 × 93 (W × H × D)
35 × 130 × 100.5 (W × H × D)
Up to 1024 bytes (512 words) of data can be
transferred (at 20 words/PC cycle)
Note: Supply 26 VDC to the R/W Head and R/W Antenna. Refer to the C200H and C200HS Installation Guides (W111, W218, W236)
and design the system by taking the total current consumption of the Units into account.
19
Accessories (Sold Separately)
Data Carrier Mounting Brackets
Model
Compatible DCs
V600-A81
V600-D2KR16
Remarks
Secure with at least two M3 flat-head screws.
Data Carrier Battery Replacement Kit
Model
Compatible DCs
V600-A82 Lithium battery
(see note)
V600-D2KR16
Remarks
Commercially available CR2016 battery.
Note: The Data Carrier Battery Replacement Kit includes a battery (CR2016), battery cover, and battery cover seal. This kit will ensure
that the Data Carrier meets IP50 environmental resistance standards after battery replacement.
RS-232C Cable
Model
Cable length
XW2Z-200P
2m
XW2Z-500P
5m
XW2Z-200S
2m
XW2Z-200S
5m
Compatible ID Controllers
V600-CA1A
V600-CD1D-V2
Connectors for ID Controllers
Model
Name
XM2A-0901
Connector Plug
XM2S-0911
Connector Hood
XM2A-2501
Connector Plug
XM2S-2511
Connector Hood
Accessories
Connector Plug
Connector Hood
20
Compatible ID Controllers
V600-CA2A
V600-CD1D-V2
V600-CA1A
V600-CA8A
V600-CA9A
Dimensions
Data Carriers
Built-in-battery DCs
V600-DjKR01/DjKR11
V600-DjKR02/DjKR12
65
55±0.2
86
31
76±0.2
5
Four, 4.5 dia.
mounting holes
5
27
Two, 4.5 dia.
mounting holes
10
10
40
54
30±0.2
44±0.2
20
Case: ABS plastic
Filler: Epoxy plastic
10
15
V600-DjKR03/DjKR13
V600-DjKR04
86
Two, 4.5 dia.
mounting holes
86
27
Case: ABS plastic
Filler: Epoxy plastic
8
31
5
10
Four, 4.5 dia.
mounting holes
5
76±0.2
10
54
54
44±0.2
44±0.2
76±0.2
5
10.3
Case: ABS plastic
Filler: Epoxy plastic
5
20
Case: ABS plastic
Filler: Epoxy plastic
10
Replaceable-battery DCs
V600-D2KR16
Four, R1.5
65
40
R0.5
5
Case: ABS plastic
Battery-less DCs
V600-D23P53
V600-D23P54
V600-D23P61
36
8 –0.10
R0.2
R0.3
0
12 –0.2 dia.
dia.
30±0.1
24
2-R1.0
24
0
5 –0.1
Case: ABS plastic
Filler: Epoxy plastic
6 –0.20
Two, 3.5 dia.
mounting holes
6
Case: ABS plastic
Filler: Epoxy plastic
2.2
Case: ABS plastic
Filler: Epoxy plastic
21
Battery-less Card-type DCs
V600-D23P71
V600-D23P72
Four, R2
86
50
Four, R2
34
54
Case: Glass epoxy plastic
Coating: Polyurethane plastic
1.5
1.5
Case: Glass epoxy plastic
Coating: Polyurethane plastic
R/W Heads
V600-H06/H12
100
5
90±0.2
5
32
Power indicator
11
Four, 4.5 dia. mounting holes
43
70
60±0.2
14.7
Bushing
Connector
8-conductor cable
(6-mm dia. with seven 0.12-mm wires)
Case: ABS plastic
Filler: Epoxy plastic
Cable: PVC (oil-resistant)
30
20
V600-H07
100
Four, 4.5 dia.
mounting holes
90±0.2
5 5
50
Power
indicator
50
25
43
100
14.7
90±0.2
Operation
indicator
Bushing
10
Connector
8-conductor cable (6-mm dia.
with seven 0.12-mm wires)
10
14
30
20
22
11
Case: ABS plastic
Filler: Epoxy plastic
Cable: PVC (oil-resistant)
V600-H11
Two, R5
Four, R1
Two, 4.5 dia.
mounting holes
Bushing
10
Vinyl-insulated round cord
(6-mm dia.)
Connector
40
14.7
dia.
28±0.1
43
5
5
27
53
Power (green)/transmission
(orange) indicators
5
6
13
18
20
Case: ABS plastic
Filler: Epoxy plastic
Cable: PVC (oil-resistant)
23
11
V600-H52
V600-H51
80
(72)
(66)
62.5
7
43
12
19.8 dia.
14.7 dia.
M22 x 1
2 lock nuts
V600-HA51
14.7 dia.
2 lock nuts
2 lock washers
Power (green)/transmission (orange) indicators
Brass
ABS plastic
Epoxy plastic
PVC (oil-resistant)
Operating indicator (orange)
Connector
Vinyl-insulated round cord
(6-mm dia.)
M22 x 1
Power (green)/transmission (orange) indicators
Case:
Transmission window:
Filler:
Cable:
43
12 dia.
Connector
Vinyl-insulated round cord
(6-mm dia.)
2 lock washers
85
(77)
(71)
67.5
Case:
Transmission window:
Filler:
Cable:
Brass
ABS plastic
Epoxy plastic
PVC (oil-resistant)
Power indicator (green)
22.6 22
12.8 dia.
51.7
5.9
Connector
61.8
5
(10,000)
43
13.7 dia.
36.5
14.7 dia.
23.5
Connector
8
4
Two, 4.5 dia.
mounting holes
13.2
6.1 Vinyl-insulated round cord
(6-mm dia.)
8-conductor cable (6-mm dia.
with seven 0.12-mm wires)
51.3±0.2
35.6
Case: ABS plastic
Filler: Epoxy plastic
Cable: PVC (oil-resistant)
V600-HS51
2 lock washers
2 lock nuts
M12 x 1
Vinyl-insulated round cord (4-mm dia.)
Connector
13.7 dia.
9.6 dia.
7
49.5
33
35
Case:
Transmission window:
Filler:
Cable:
Brass
ABS plastic
Epoxy plastic
PVC (oil-resistant)
V600-HS61
30.5
18
12±0.1
4.5
8.5
49.5
18
Detection
surface
10
13.7 dia.
Two, 3.5 x 5
mounting holes
6.5
Connector
Vinyl-insulated
round
cord
(4-mm dia.)
Case: ABS plastic
Filler: Epoxy plastic
Cable: PVC (oil-resistant)
23
ID Controllers
V600-P01 Monitor Unit
(For use with V600-CAjA and
V620-CAjA Controllers)
V600-CAjA (Multipurpose)
100
35.3
90±0.3
80.6
120.6
9.3
190±0.3
200
100
22.6
Four, 4.3 dia.
mounting holes
V600-CD1D-V2 (Compact)
V600-CB-US-S Hand-held ID
Controller
45.5
105
18
53
68
17.5
5.5
81
270
Two,
4.5 dia.
92
80
115
38
ID Sensor Units
24
80
C500-IDS01-V2
C500-IDS02-V1
C500-IDA02
Rack Dimensions (Reference)
250
480
Rack
250
375
34.5
93
115
115
170
276
C200H-IDS01-V1
Rack Dimensions (Reference)
130
435
Rack
130
130
330
35
100.5
117
Approx. 200
130
260
25