Download Sony DSR 1500 Manual
Transcript
Connection of a video monitor Settings on an editing control unit Set up the following connections to enable monitoring of video and audio signals on a video monitor. In addition to the video and audio signals, you can have time data, the operation mode of the unit, alarm messages, and other information displayed as text on the monitor screen by setting the CHARA. DISPLAY menu item (see page 60) to ON (factory default setting). When connecting an editing control unit, make the settings as follows, according to the model. 75 Ω termination switch: ON (or attach a 75 Ω terminator) Input switches: Set according to the type of input signals. Video monitor PVE-500 No settings are required. BVE-600/900/910/2000 (NTSC model) or FXE-100/ 120 Set the VCR constants as follows. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 80 17 00 96 05 05 03 80 0A 08 FE 00 80 5A FF BVE-600/900/910/2000 (PAL model) or FXE-100P/ 120P Set the VCR constants as follows. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 81 17 00 7D 05 05 02 80 0A 07 FE 00 80 4C FF Composite video input Audio input 2 VIDEO OUT B-Y/CPST (SUPER) RM-450/RM-450CE Set the DIP switches as follows. • Left switches 7 6 5 4 3 2 1 0 OFF − − OFF − − − − 1 • Right switches (RM-450) ) MONITOR 7 6 5 4 3 2 1 0 OFF − OFF ON OFF OFF ON ON • Right switches (RM-450CE) Chapter 5 Connections and Settings 88 DSR-1500/1500P (recorder) A Cable with RCA phono plugs (not supplied) B 75 Ω coaxial cable (not supplied) 7 6 5 4 3 2 1 0 ON − OFF ON OFF OFF ON ON BVE-800 Set the DIP switches as follows. • SW2 1 2 3 4 5 6 7 8 ON OFF ON ON − ON ON − • SW3 (NTSC model) 1 2 3 4 5 6 7 8 ON ON ON OFF − ON OFF OFF • SW3 (PAL model) Connections for an A/B Roll Editing System 1 2 3 4 5 6 7 8 OFF OFF OFF ON − ON OFF OFF