Transcript
2-3. Functions of Service Mode 2-4. White Balance Adjustment 1. COLOR TEMP This is used for the white balance adjustment at color temperature 9300 K and 6500 K. The adjustment requires to be done for every input (INPUT1: DVI-D, INPUT1: HD15, or INPUT2: HD15) by switching the input. The adjustment data is stored into the register for respective inputs. 2. INITIAL EEPROM This sets the data of the EEPROM to the default data. This operation is not required usually. < Preparation > (1) Measurement point : Center of screen (2) Measurement distance : 50 cm (3) Measurement angle : 90° (4) Color analyzer (Minolta CS-1000 or equivalent) (5) Signal generator (Astro Design VG-828D or equivalent) Be sure to calibrate the analog RGB output level with 75Ω termination. 3. CLEAR ETI TIME This resets the ETI (Elapsed Time Indicator) counter to 00000 H. 4. EEPROM TEST This tests writing and reading of the EEPROM. 5. RGB RESET This adjust the offset and gain of the input AD converter for the analog inputs (INPUT1: HD15 and INPUT2:HD15). As these adjustments are common to both inputs, perform them for either input. It is unnecessary for another input. Execute the adjustments under the condition where the signal specified in "White Balance Adjustment" is input. 6. 7. AGING IN MODE This sets and clears the NO SYNC AGING flag. AGING MODE = ON: Sets the NO SYNC AGING flag. AGING MODE = OFF: Clears the NO SYNC AGING flag. When the NO SYNC AGING flag is set and the input with no input signal is selected, the system goes into the AGING MODE. The NO SYNC AGING flag is held until it is cleared. To clear the NO SYNC AGING flag, go into the service mode and then set the AGINGN MODE to OFF, or execute the all mode recall. 1. Service mode setting Enter the service mode referring to step 1 and 2 of Section 2-2. 2. Aging Set the AGING MODE in the service mode to ON. Disconnect the signal input terminal or select the input with no signal input, and the system goes into the AGING MODE. Execute aging for 30 minutes or more. 3. User control setting Feed a signal to the selected input, and then execute reset in the menu screen. Then, move the menu display position to avoid the measurement point. Or, set the following for respective inputs. BACKLIGHT (Brightness of backlight) = 100 CONTRAST = 70 BRIGHTNESS = 50 Menu display position = not center of screen (Avoid the measurement point.) (The setting of the menu display position is common to respective inputs.) ECO = OFF (The setting of ECO is common to respective inputs.) Do not change the above setting until the white balance adjustment is completed. CONTROL REG. This can check the data of the internal registers. This operation is not required usually. SDM-X72(E) 2-3