Download GR 47 / GR 48 Technical Description
Transcript
GR47/GR48 Technical description 3.4 Regulated Power Supply Pins Name Description 1, 3, 5, 7, 9 VCC Regulated Power Supply The regulated power supply, VCC, is connected to the pin numbers 1, 3, 5, 7 and 9. 3.4.1 Power Supply (VCC) The VCC supplies the module with external power. Any other voltage needed is generated internally. Parameter Mode Limit Voltage to be applied Nominal 3.6 Volts Tolerance including ripple 3.4 Volts - 4.0 Volts 1 Over voltages Current Drive capability at TX Full Power 5.5 Volts < 600 mA (average)) < 2 A (Peak) GR 47/48 have not internal capacitance to supply the large current peaks during GSM transmission. Therefore on burst transmission the application DC source is responsible for providing the appropriate current. Design application notes are available from customer support on request. 3.4.2 Battery Charging Input (CHG_IN) The battery charging pin is design to provide a charging current into a battery. The precise algorithm is TBD but it will be one of the following • • 1 Generic charging algorithm implemented and further refinements for the algorithm to be implemented through embedded applications (see section 6) Specific charging algorithms for SEM approved batteries. Measured at system connector pins. GBBA/SEM/BMS 03:0001 Rev A 19