Download Prestige Trouble Shooting Guide

Transcript
Control Module Display - General
Display
Error Hard Lockout Mode
E 00
E 02
E 03
E 04
E 05
E 06
E 07
E 08
E 09
E 11
E 12
E 13
E 14
E 15
E 16
E 17
E 18
E 19
E 24
E 25
E 28
E 29
E 31
E 32
E 35
E 36
E 37
E 40
E 44
E 52
E 60
E 61
E 65
E 113
E 115
E 122
E 1 23
E 1 24
If a serious fault occurs, the system enters a hard lockout
condition which requires a manual reset by pressing the
RESET Button. A hard lockout is indicated by displaying
an E for the first digit, followed by the error code.
For detailed information on the corrective and preventive
actions for the hard lockout, see pages 18-26.
CAUTION
The boiler freeze protection feature is disabled
during a Hard Lockout, however the CH circulator
will operate.
CAUTION
During a hard lockout or low water condition the
boiler will not re-start without service. If the heating system is left unattended in cold weather
appropriate safeguards or alarms should be
installed to prevent property damage.
NOTICE
An optional AM-4 Interface module kit, PSRKIT23
can be added to any Prestige to provide contacts
for an external alarm in the event the boiler enters
into a hard Lockout.
9
Hard Lockout
Flame detected prior to burner startup
Failed ignition after 5 attempts
Gas valve harness not properly connected
Power supply lost after lockout occured
Electrical Interference
Internal control failure
Internal control failure
Internal control failure
Internal control failure
Internal control failure
External limit (terminals 13 & 14) is OPEN
Internal control failure
Low voltage internal short or voltage backfeed
Internal control failure
Internal control failure
Internal control failure
Supply Temperature exceeds 212 F
Return Temperature exceeds 212 F
Return temperature is higher than supply
temperature
Supply Temperature increased too rapidly
No blower signal present
Blower signal does not reset to zero
Supply Temperature sensor is short circuited
Return Temperature sensor is short circuited
Flue Temperature sensor is short circuit
Supply Temperature sensor is OPEN
Return Temperature sensor is OPEN
Flue Temperature sensor is OPEN
Gas Valve Circuit failure
Flue Temperature exceeds 250 F
Internal control error - failure to read parameters
Internal control failure
Inadequate power supply to the fan
Invalid power frequency
Internal control failure
Supply or Return Temperature sensor drift
Supply or Return Temperature failure
Supply or Return Temperature not changing