Clarifications, Known Behaviors, and Resolved Issues
Automatic Memory Scanning Can Trigger Incorrect Reboot Loop Detection
On Summit and Alpine switches, if memory scanning is automatically initiated via the auto-recovery
parameter in the configure sys-health-check command and the reboot loop detection threshold is 1,
the system might incorrectly detect a reboot loop and come up in minimal mode (PD2-140185601).
Packet Diagnostics Display Backplane Incorrectly
When you run packet diagnostics on the Alpine 3804, the console displays the backplane as slot 5. The
display is wrong: the diagnostics are correctly running on the backplane. The extended diagnostics
console display is correct (PD2-151752701).
Packet Diagnostics Display Wrong Slot Name
When you run packet diagnostics on the MSM in slot B, the console displays the slot as slot 10, instead
of MSM-B. The display is wrong: the diagnostics are correctly running on the MSM in slot B. The
extended diagnostics console display is correct (PD2-138607801).
Bus-Stats Error Messages
The show config detail command output displays the following new commands:
disable bus-stats
configure bus-stats
configure bus-stats
configure bus-stats
configure bus-stats
window history 3
window errors 3
threshold slow-path x
threshold fast-path y
The bus-stats feature helps filter erroneous log messages related to transient hardware errors. It is
disabled by default and should only be enabled when troubleshooting transient hardware errors.
Enabling this feature requires activation by Extreme Networks personnel.
Spurious Message When system-down is Configured
If you configure the system health check alarm level for system-down and a fault is detected, the switch
is turned off but continuously logs the message “Card in slot N is off line.” You can ignore this message
(PD2-129386201).
The use configuration Command
When the switch is in minimum mode, the use configuration command has no effect on the backup
MSM (PD2-129133801).
Output of the show diagnostics Command
The output of the show diagnostics command for the CPU system might display negative numbers,
and the totals might not add up properly (PD2-128460401).
Configure Auto-Recovery to online or Alarm-Level to traps
If you configure the system health check auto-recovery to offline, save the configuration, and
configure the alarm-level to log, a health check brings the module or switch offline regardless of how
many errors the health check detects. To avoid this, either configure auto-recovery to online, or
configure alarm-level to traps (PD2-124368101).