7 - USE
“E”
Code
Lock-out
description
Controls
Solutions
E11
N TC 1 b o i l e r te m p e r a tu r e Check that the electrical element
sensor circuit short-circuited. of the sensor complies with the
graph indicated in section 8.17;
check the electrical connection
cables between the probe and
the command board
If the electrical element of the probe does not
comply, it must be replaced; if the electrical
circuit is damaged, it must be repaired; if the
previous two cases do not apply, replace the
command and control board
E12
NTC2 domestic hot water Check that the electrical element
temperature sensor circuit of the sensor complies with the
short-circuited
graph indicated in section 8.17;
check the electrical connection
cables between the probe and
the command board
If the electrical element of the probe does not
comply, it must be replaced; if the electrical
circuit is damaged, it must be repaired; if the
previous two cases do not apply, replace the
command and control board
E13
E14
Erroneous temperature reading.
Replace the command and control board
Erroneous temperature reading.
Replace the command and control board
E15
E16
E17
Erroneous temperature reading.
Replace the command and control board
Erroneous temperature reading.
Replace the command and control board
NTC3 cold water temperature Check that the electrical element
sensor circuit short-circuited of the sensor complies with the
graph indicated in section 8.17;
check the electrical connection
cables between the probe and
the command board
If the electrical element of the probe does not
comply, it must be replaced; if the electrical
circuit is damaged, it must be repaired; if the
previous two cases do not apply, replace the
command and control board
E18
NTC6 boiler temperature Check that the electrical element
sensor circuit short-circuited of the sensor complies with the
graph indicated in section 8.17;
check the electrical connection
cables between the probe and
the command board
If the electrical element of the probe does not
comply, it must be replaced; if the electrical
circuit is damaged, it must be repaired; if the
previous two cases do not apply, replace the
command and control board
E19
E2prom memory damaged
Replace the command and control board
E20
Flame presence with gas
valve closed
Replace the gas valve
E21
Phase and neutral inverted
Invert phase and neutral
E22
Mains frequency other than Check the electrical frequency If the mains frequency is other than 50Hz,
50Hz
of the system.
contact the electricity distribution company;
if the mains frequency is 50Hz, replace the
command and control board.
E23
No earth connection
E30
E31
E32
E33
E42
Erroneous temperature reading.
Replace the command and control board
Erroneous temperature reading.
Replace the command and control board
Erroneous temperature reading.
Replace the command and control board
Erroneous temperature reading.
Replace the command and control board
E50
Boiler TYPE selection error
E51
Reset button pressed too often
in a short period of time
Check the correct earthing of Restore the correct earthing of the system.
the system.
If the earth correction is already sufficient,
replace the command and control board.
Programme error or earth Check the correct earthing of Restore the correct earthing of the system.
connection insufficient
the system.
If the earth correction is already sufficient,
replace the command and control board.
Check the JUMPERS selector If the selector switches are positioned correctswitch as per section 7.5.
ly, replace the comand and control board
44