Download Eden Manual
Transcript
• Direct Vent Freestanding Stove • Natural Gas or Propane • Vent Horizontally or Vertically • Standard Residential • Mobile Home Approved Tested and Listed by Featuring the WARNING: - Omni-Test Laboratories, Inc. Portland, Oregon Report # 028–S–50c-5 ANSI Z21.88, Burner If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the gas supplier. This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the appliance. Eden Owner’s Manual Installer: After installation give this manual to the home-owner and explain operation of this heater. Copyright 2009, T.I. $10.00 100-01238_000 4091026 www.travisproducts.com 4800 Harbour Pointe Blvd. SW Mukilteo, WA 98275 Introduction 2 Introduction We welcome you as a new owner of an Avalon Eden stove. In purchasing a Eden you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The Eden is one of the finest home heaters the world over. This manual will explain the installation, operation, and maintenance of this stove. Please familiarize yourself with the Owner's Manual before operating your heater and save the manual for future reference. Included are helpful hints and suggestions that will make the operation and maintenance of your new stove an easier and more enjoyable experience. We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your heater. Important Information No other Eden Stove has the same serial number as yours. The serial number is on the listing plate chained to the gas control valve. Mail your Warranty Card Today, and Save Your Bill of Sale. This serial number will be needed in case you require service of any type. To receive full warranty coverage, you will need to show evidence of the date you purchased your heater. Do not mail your Bill of Sale to us. Model: Avalon Eden GS Serial Number: We suggest that you attach your Bill of Sale to this page so that you will have all the information you need in one place should the need for service or information occur. Purchase Date: Purchased From: Listing Details This appliance was listed by OMNI Test Labs to ANSI Z21.88 - report # 028-S-50c-5. The listing label is attached to the appliance near the gas control valve. A copy is shown on page 43. IAS (ICBO) Approval This appliance was listed by OMNI Test Labs - IAS # TL130. Massachusetts Approval This manual has been submitted to the Massachusetts Board of State Examiners of Plumbers and Gas Fitters National Fireplace Institute © Travis Industries 4091026 100-01238_000 Table of Contents Introduction 3 Operation Introduction & Important Information ................... 2 Before You Begin ................................................ 35 Location of Controls ............................................ 35 Safety Precautions Starting the Stove for the First Time ................... 36 Safety Precautions .............................................. 4 Turning the Stove On and Off ............................. 36 Features & Specifications Comfort Control ................................................... 36 Features .............................................................. 6 Adjusting the Flame Height ................................. 36 Installation Options ............................................. 6 Accent Light ........................................................ 37 Heating Specifications......................................... 6 Adjusting the Optional Blower Speed .................. 37 Dimensions ......................................................... 6 Continuous Pilot / GreenSmart™ Pilot Switch..... 37 Normal Operating Sounds................................... 38 Installation Normal Operating Odors ..................................... 38 Installation Warning............................................. 7 Switch Box Installation ........................................ 7 Maintenance Packing List......................................................... 8 Maintaining Your Stove’s Appearance ................ 39 Additional Items Required for Installation ............ 8 Battery Replacement........................................... 39 Installation Overview ........................................... 8 Accent Light Replacement .................................. 40 Installation Hints .................................................. 8 Yearly Service Procedure ................................... 40 Stove Clearances ................................................ 9 Mobile Home Requirements ................................ 9 Troubleshooting Table ........................................ 41 Wiring Diagram ................................................... 42 Top to Rear Vent Modification............................. 10 Replacement Parts List ....................................... 42 Heater Placement Requirements ........................ 12 Floor Protection Requirements ........................... 12 Safety Label Electrical Requirements ...................................... 12 Safety Label ........................................................ 43 Optional Wall Switch or Thermostat Installation .. 13 Gas Line Installation............................................ 14 Warranty Warranty ............................................................. 44 Vent Requirements ............................................. 15 Approved Vent Configurations ............................ 16 Intake Restrictor ............................................ 16 Optional Equipment LP Conversion Kit ............................................... 45 Intake Damper Plates .................................... 16 GreenSmart™ Remote Control Installation ......... 48 Exhaust Restrictor ......................................... 17 Exhaust Restrictor Extender Plate ................. 17 Index Diffuser .......................................................... 17 Index ................................................................... 60 Vent Termination Requirements ......................... 24 Class A Chimney Conversion.............................. 25 Interior Masonry Chimney Conversion ................ 26 Finalizing the Installation Leak Test ............................................................ 27 Pilot Adjustment (if necessary) ............................ 27 Air Shutter Adjustment (if necessary) .................. 28 Check Flame ....................................................... 28 Face and Glass Removal .................................... 29 Log Installation .................................................... 31 © Travis Industries 4091026 100-01238_000 Safety Precautions 4 • IF YOU SMELL GAS: * Do not light any appliance * Extinguish any open flame * Do not touch any electrical switch or plug or unplug anything * Open windows and vacate building * Call gas supplier from neighbor's house, if not reached, call fire department • • This unit must be installed by a qualified installer to prevent the possibility of an explosion. Your dealer will know the requirements in your area and can inform you of those people considered qualified. The room heater should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The instructions in this manual must be strictly adhered to. Do not use makeshift methods or compromise in the installation. Improper installation will void the warranty and safety listing. This heater is either approved for natural gas (NG) or for propane (LP). Burning the incorrect fuel will void the warranty and safety listing and may cause an extreme safety hazard. Direct questions about the type of fuel used to your dealer. Check for a label on the flame adjust knob on the gas control valve (this is the best place to check). You may also check for a label on the gas control valve body. • Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area. Notify your insurance company of this heater as well. • If the flame becomes sooty, dark orange in color, or extremely tall, do not operate the heater. Call your dealer and arrange for proper servicing. • It is imperative that control compartments, screens, or circulating air passageways of the heater be kept clean and free of obstructions. These areas provide the air necessary for safe operation. • Do not operate the heater if it is not operating properly in any fashion or if you are uncertain. Call your dealer for a full explanation of your heater and what to expect. Ok • Gas © Travis Industries Do not store or use gasoline or other flammable liquids in the vicinity of this heater. 4091026 ? • Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 100-01238_000 Safety Precautions Do not place clothing or other flammable items on or near the heater. Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near it. • Light the heater using the built-in igniter. Do not use matches or any other external device to light your heater. The viewing glass should be opened only for lighting the pilot or conducting service. Any safety screen or guard removed for servicing must be replaced prior to operating the heater. Do not operate with the glass removed or damaged. • Never remove, replace, modify or substitute any part of the heater unless instructions are given in this manual. All other work must be done by a trained technician. Don't modify or replace orifices. • Operate the heater according to the instructions included in this manual. • If the main burners do not start correctly turn the gas off at the gas control valve and call your dealer for service. • Instruct everyone in the house how to shut gas off to the appliance and at the gas main shutoff valve. The gas main shutoff valve is usually next to the gas meter or propane tank and requires a wrench to shut off. • This unit is not for use with solid fuel • Do not place anything inside the firebox (except the included fiber logs). • If the fiber logs become damaged, replace with Travis Industries log set. • Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be supervised when they are in the same room as the heater. • • • • • © Travis Industries 5 • Allow the heater to cool before carrying out any maintenance or cleaning. • Do not throw this manual away. This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual. This Manual • • Plug the heater into a 120V grounded electrical outlet. Do not remove the grounding plug. Don’t route the electrical cord in front of, over, or under the heater Travis Industries, Inc. grants no warranty, implied or stated, for the installation or maintenance of your heater, and assumes no responsibility of any consequential damage(s). 4091026 100-01238_000 Specifications 6 Features: - Installation Options: Ember Fyre™ Burner for "Wood Fire" Look Works During Power Outages (battery backup system) High Efficiency Optional Thermostat or Remote Control Optional Blower for Quicker Heat Distribution Convenient Operating Controls Variable-Rate Heat Output Accent Light - Freestanding Stove - Horizontal or Vertical Vent - Residential or Mobile Home - Straight or Corner Placement - Bedroom Approved Heating Specifications: Approximate Heating Capacity (in square feet)* ........... 500 - 850 with Blower, 500 to 650 Without Maximum Input (in BTU’s) ..............................................................................22,000 • Heating capacity will vary depending on the home’s floor plan, degree of insulation, and the outside temperature. Dimensions & Weight: The flue collar protrudes 3-7/8" (98mm) behind the stove top 16" 406mm 11-1/2" 292mm 21-1/4" 540mm The flue collar protrudes 1-3/8" (35mm) above the stove top 14-3/8" 365mm 21-1/4" 540mm 26-1/2" 673mm NOTE: Measure side, corner, and back clearances from the stove top. Weight 130 Lbs. (59 Kg) Electrical Specifications (including optional blower) Electrical Rating ............................................................. 120 Volts, 1.5 Amps, 60 Hz (180 watt) Fuel: This heater is shipped in natural gas (NG) configuration but may be converted to propane (LP) using the included LP conversion kit. The sticker on top of the gas control valve will verify the correct fuel. © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 7 Installation Warnings: ! ! ! ! ! ! ! ! Failure to follow all of the requirements may result in property damage, bodily injury, or even death. This heater must be installed by a qualified installer who has gone through a training program for the installation of direct vent gas appliances. This appliance must be installed in accordance with all local codes, if any; if not, in U.S.A. follow ANSI Z223.1 and NFPA 54(88), in Canada follow B-149. In Manufactured or Mobile Homes must conform with: In USA, Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280; In Canada, CSA Z240.4 and GasEquipped Recreational Vehicles and Mobile Housing. This appliance may be installed in Manufactured Housing only after the home is site located. This stove is designed to operate on natural gas or propane (LP). All exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn from outside the living-area structure. Notify your insurance company before hooking up this stove. The requirements listed below are divided into sections. All requirements must be met simultaneously. The order of installation is not rigid – the qualified installer should follow the procedure best suited for the installation. Switch Box Installation The switch box is shipped detached on this stove. Attach it following the directions below. a c d b a) Loosen the three screws used to secure the switch box. b) Loosen the three screws holding the wire cover. Remove the wire cover and place it aside. c) Slide the switch box into place and secure with the three screws. d) Slide the wire cover into place, making sure it does not pinch any wires. Secure with the three screws. © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 8 Packing List Additional Items Required • • • • • • • • • Propane Conversion Kit Log Set Touch-Up Paint Batteries (4 AA and 1 9v) Rear Vent Flue Cover Intake Damper Plates (2) Exhaust Restrictor Extender Plate Vent (see “Venting Requirements” for details) Gas Line Equipment (shutoff valve, pipe, etc.) Installation Overview See "Clearances" See "Vent Requirements" See "Gas Line Installation" See "Floor Protection Requirements" © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 9 Installation Hints: Recommended Optional Equipment Installation Order: -- GreenSmart Remote -- Blower -- LP Conversion and other optional equipment Install the logs last - they are fragile. When determining the location of the stove, locate the wall studs (for horizontal penetrations) and ceiling trusses (for vertical penetrations). You may wish to adjust the stove position slightly to ensure the vent does not intersect with a framing member. Fumes and smoke from the paint curing and oil burning off the steel may occur the first time you start this heater. This is normal. We recommend you open windows to vent the room. Stove Clearances NOTE: If using the rear vent configuration, you will require approximately 8-1/2” to the rear of the stove for the vent adapter and thimble. See page 18 for details. Straight Installations Corner Installations With this clearance the top vent is centered 8" (203mm) from the back wall, 14-1/4" (362mm) from the side wall. With this clearance, the vent is centered 10-1/4" (260mm) from the wall. 3-1/2" Min. 89mm 1" Min. 25mm 5" Min. 127mm (See note above regarding rear vent configurations) 45° Mobile Home Requirements • When the stove is installed in a mobile home, it must be bolted to the floor and the appliance grounded (use the optional blower with a grounded circuit or other suitable grounding method current ANSI/NFPA 70 or CSA C22.1). © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 10 Top to Rear Vent Modification NOTE: If using the rear vent configuration, make sure to review vent configuration before proceeding. Remove the cast iron stove top and flue cover to access the vent components (see page 29) NOTE: Use a magnetic-tipped nutdriver on these screws - take care to prevent the screws from falling into the intake channel. Remove the outer flue assembly, cover plate, and gaskets. Place the screws and components aside (for all subsequent steps). Inner Flue Assembly Remove the inner flue assembly and exhaust cover plate. Exhaust Cover Plate ADJUSTING THE DIFFUSER ON THE INNER FLUE ASSEMBLY b Bend the round portion of the Rear vent configurations with no rise require the diffuser to be bent to the # 2 position. It is easiest to adjust this component with the inner flue removed. See the directions below. diffuser so it is bent (position # 2). DIFFUSER SIDE VIEW Bottom of inner flue assembly Before (Stock - Position # 1) c a Remove the diffuser. © Travis Industries After (Position # 2) 4091026 Replace the diffuser. 100-01238_000 Installation (for qualified installers only) 11 Top to Rear Vent Modification (continued) Install the inner flue assembly and exhaust cover plate. Make sure the attached gaskets are in place and form an air-tight seal. NOTE: Install the flue assembly with the diffuser to the bottom. Install the outer flue assembly, cover plate, and gaskets. Make sure the gaskets are correctly positioned and form an airtight seal. The flue cover with a cutout may be discarded. Use the flue cover designed for rear vent applications. © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 12 Heater Placement Requirements • Heater must be installed on a level surface capable of supporting the heater and vent • Due to the high temperature, the heater should be located out of traffic and away from furniture and draperies. • When placed in a location where the floor to ceiling height is under 7 feet, the installation is considered an alcove and must meet the following requirements: - The alcove floor to ceiling height must be at least 38-1/8” (968mm) tall - The alcove must not be more than 24” (610mm) deep before the ceiling returns to 7’ (2134mm) - The alcove must be at least 28-1/4” (718mm) wide • The heater must not be placed so the vents below or above the door, along the sides of heater, or along the back of the heater can become blocked. This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance produces when determining a location. • Floor Protection Requirements • When the stove is installed directly on carpeting, vinyl or other combustible material other than wood flooring or a high pressure laminate wood floor, the stove must be installed on a metal or wood protection panel extending the full width and depth of the heater (Minimum 21-1/4” wide by 16” deep). Make sure these rubber tipped bolts on each leg contact the floor (they dampen any noise that may transmit through the hearth). Do not adjust with weight on the legs, the rubber tips may tear. Electrical Requirements • Plug the stove into a grounded receptacle supplying a minimum 1.5 amps (120 Volts, 60 Hz, 180 watts). © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 13 Optional Wall Switch or Thermostat Installation Do not connect 110-120 VAC to the gas control valve or wiring system of this stove. The switch must be installed by a qualified installer. This stove may be installed with an optional wall switch or thermostat. wires will interrupt the burner circuit (see item “a” below). The thermostat (or on/off switch) 1. If you wish to bypass the switch, connect the thermostat (on/off switch) wires directly to the green and white wires (see “b” below). 2. If you wish keep the switch (series) – re-align the wires as shown in item “c” below. NOTE: The on/off switch must be in the “ON” position for the thermostat (or on/off switch) to operate. Burner Circuit Wires POWER SUPPLY Black Red Black Red Red Red ON / OFF Blue Red a Green White Blue Black COMFORT CONTROL b AA BATTERY TRAY MAIN BURNER Bypass c Thermostat or On/Off Switch Series White Green Green Thermostat or On/Off Switch White © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 14 Gas Line Installation ! The gas line must be installed in accordance with all local codes, if any; if not, follow current ANSI Z223.1 or NFPA 54 in the USA and the current CGA B149 in Canada. ! The heater and gas control valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPA). For pressures under 1/2 psig (3.45 kPA), isolate the gas supply piping by closing the manual shutoff valve. • This heater is designed for natural gas but can be converted to propane. Check the sticker on top of the gas control valve to verify the correct fuel is used (see page 4). • Leak test all gas line joints and the gas control valve prior to and after starting the heater. • The location of the gas inlet is shown below • A manual shutoff valve is required for installation (it must be located within 3’ of the heater). T-Handle gas cocks are required in Massachusetts in compliance with code 248CMR. • This stove is shipped with a 16” long, 3/8” diameter flex gas line attached to an elbow on the gas control valve (see illustration below for location). The flex accepts a 3/8” flare fitting. C te en rlin e 7" 178mm 5-3/4" 146mm 6-1/4" 159mm Gas Inlet Pressure • With the heater off, the inlet pressure must meet the requirements listed in the table below • If the pressure is not sufficient, make sure the piping used is large enough and the total gas load for the residence does not exceed the amount supplied. • The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) should supply gas at the suggested input pressure listed below. Contact the local gas supplier if the regulator is at an improper pressure. Natural Gas Propane © Travis Industries Standard Input Pressure 7” W.C. (1.74 Kpa) 13” W.C. (3.23 Kpa) 4091026 100-01238_000 Installation (for qualified installers only) 15 Vent Requirements • The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance must use its own separate vent system. In addition to the requirements listed here, follow the requirements provided with the vent. When the vent passes through a wall a wall thimble is required. When the vent passes through a ceiling a support box or firestop is required. When the vent passes through the roof, a roof flashing and storm collar are required. Follow the instructions provided with the vent for installing these items. NOTE: Wall thimbles may have different dimensions than what is required by this heater. • The vent must maintain the required 1" clearance to combustible materials to prevent a fire. Do not fill air spaces with insulation. Altitude Considerations • • Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard. Consult your dealer or installer if you suspect an improperly adjusted air shutter. This heater has been tested at altitudes ranging from sea level to 6,000 feet (1,800 M). In this testing we have found that the heater, with its standard orifice, burns correctly with just an air shutter adjustment. Approved Caps Always use the high-wind cap (the sconce cap is not approved for this stove). Vertical Termination NOTE: always use the "highwind" version (if applicable) Vertical Vent Requirements Use a roof flashing and storm collar whenever passing through the roof Use a firestop whenever passing through a ceiling Maintain a minimum 1"(25mm) clearance from vent to any combustible Use a support box on exposed vent Use a thimble when passing through a wall Horizontal Vent Requirements Minimum Framing for wall thimble Maintain a minimum 1"(25mm) clearance from vent to any combustible. Horizontal Termination Approved Vent Use Simpson Dura-Vent Direct-Vent Pro (or GS)*. * Other vent may be approved with this stove. Check with the vent manufacturer for details. Vent Diameter is determined by vent configuration. Rear vent configurations with no rise use 8” (203mm) diameter vent, all other vent configurations use 6-5/8” (168mm). See Approved Vent Configurations on page 16 for details. Installation instructions for Simpson Dura-Vent may be found at www.duravent.com Vent Installation • • • • • • Slide the vent sections together and turn 1/4 turn until the sections lock in place. Screws are not required to secure the vent. However, three screws may be used to secure vent sections together if desired. High temperature sealant is recommended at the appliance starter section connection (use hightemperature silicone or Mill-Pac®). If disassembly is required, at time of re-assembly check to see if the vent creates a tight fit. If it does not, apply high temperature sealant to the joints of the affected sections. Horizontal sections require a 1/4" rise every 12" of travel Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape) © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 16 Approved Vent Configurations Overview This appliance has several components used to control the flow of intake air and exhaust gases. Depending upon vent configuration, you may be required to adjust the intake restrictor, exhaust restrictor, diffuser and/or install the intake dampers and extender plate. Refer to the vent configuration (pages 18 to 23) to determine the correct restrictor, damper, extender, and diffuser settings. Intake Restrictor NOTE: Refer to the vent configuration (pages 18 to 23) to determine the correct restrictor position. Adjustment Plate Pivot Point Rotate the adjustment 6 plate to change the 5 restrictor position. Index Holes 4 3 2 1 Screw NOTE: Position #1 is the fully open position To Adjust the Restrictor: 1 2 3 4 5 Determine a restrictor position (see the charts under "Approved Vent Configurations") Remove the screw. Rotate the adjustment plate counter-clockwise until the correct index hole is over the screw hole. Insert the screw into the correct index hole and tighten. Use touch-up paint to conceal any exposed steel near the restrictor. This restrictor is in Position #5. Intake Damper Plates NOTE: Refer to the vent configuration (pages 18 to 23) to determine if these plates must be installed. • Two intake damper plates are included in the owner’s pack. They are installed behind the burner in certain vent configurations. See page 45 for details on removing the burner. Remove the four screws above Attach the damper plates to the back wall of the air inlets inside the firebox. the firebox with the screws removed earlier. Intake Damper Plates (2) (found in the owner's pack) © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 17 Exhaust Restrictor NOTE: Refer to the vent configuration (pages 18 to 23) to determine the correct restrictor position. Firebo Back W all of F x Roo f Loosen these two screws irebox on the exhaust restrictor. Slide the restrictor to the correct restrictor position (see the illustration below). The screw location indicates restrictor position. In this example, the restrictor is set in position # 3. Tighten the screws to secure the restrictor. (closed) # 5 #4 #3 #2 (open - stock position) # 1 Exhaust Restrictor Extender Plate NOTE: Refer to the vent configuration (pages 18 to 23) to determine if the extender must be installed. Remove these two screws on the exhaust restrictor. Firebo Back W all of F x Roo f irebox Exhaust Restrictor Extender Plate (found in the owner's pack) Use the screws to attach the extender to the exhaust restrictor. Diffuser • NOTE: Refer to the vent configuration (pages 18 to 23) to determine if the diffuser must be adjusted. The diffuser is best accessed while converting the appliance to rear vent (see page 10). The diffuser is found on the inner flue assembly b Bend the round portion of the (see Top to Rear Vent Configuration for details). diffuser so it is bent (position # 2). DIFFUSER SIDE VIEW Bottom of inner Before (Stock - Position # 1) flue assembly c a Remove the After (Position # 2) diffuser. diffuser. © Travis Industries Replace the 4091026 100-01238_000 Installation (for qualified installers only) 18 Rear Vent Configurations with Horizontal Termination and No Rise • Use 8” Diameter Vent with a 6-5/8” to 8” adapter (increaser). We recommend using the minimum vent kit from Travis Industries (SKU 96200311). This kit contains the following components used to vent the stove through a typical exterior wall: -- 6-5/8” to 8” Adapter (Black) -- Thimble -- Thimble Cover (Black) -- Pipe (3.9”) -- High-Wind Horizontal Cap • Place the 6-5/8” to 8” adapter directly onto stove (see illustration below). • Maximum Horizontal Run of 4’. • Horizontal sections require a ¼” (6mm) rise every 12” (305mm) of travel. • Maximum of one (1) 45° elbow may be used between horizontal sections. • Diffuser must be set to closed (#2) position. • Intake and exhaust restrictor must be set to the #1 (stock) position. • Do not install the intake damper plate or exhaust restrictor extender plates. Max. 4' (1.2M) High Wind Horizontal Cap Required (58DVA-HC) Typical 8-1/2" (216mm) Min. 12" (305mm) Grade 6-5/8" to 8" Adapter Thimble w Cover Corner Installations Typical Flue Center 5-3/8" (137mm) Minimum 9" (229mm) © Travis Industries 4091026 Minimum 52" (1321mm) 100-01238_000 Installation (for qualified installers only) 19 Rear Vent Configurations with Horizontal Termination and 1’ Min. Rise • Maximum of one (1) 45° or 90° horizontal elbow may be used (see illustration). • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly, especially when the termination is near a demarcation line. • Diffuser set to open (stock) position). • Do not install the intake damper plate or exhaust restrictor extender plates. 10 feet (3m) 0 feet 12 feet max (3.6m) 24 ' max (7.3m) Horizontal sections require a ¼” (6mm) rise every 12” (305mm) of travel. 20 feet (6m) • 15 feet (4.5m) Use 6-5/8” Diameter Vent 5 feet (1.5m) • 12 feet max (3.6m) Exhaust Restrictor Position #5 Intake Restrictor Position #6 10 feet (3m) 10 feet (3m) Exhaust Restrictor Position #4 Intake Restrictor Position #5 5 feet (1.5m) 5 feet (1.5m) Exhaust Restrictor Position #3 Intake Restrictor Position #3 Min. 1' (03m) Vertical Section Required 0 feet 0 feet 0 feet Horizontal Elbow Horizontal elbows are elbows placed between two horizontal sections of pipe. One 45° or 90° horizontal elbow is allowed for this configuration. © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 20 Rear Vent Configurations with Vertical Termination • Horizontal sections require a ¼” (6mm) rise every 12” (305mm) of travel. • A maximum of three (3) elbows may be used (e.g.: one 90° and two 45° or three 90°). • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly, especially when the termination is near a demarcation line. • Diffuser set to open (stock) position). • Install the intake damper plate. • Install the exhaust restrictor extender plate. 3' max. (1m) Use 6-5/8” Diameter Vent 0 feet • 31' max (9.3m) 30 feet (9m) 31' max (9.3m) 25 feet (7.5m) 25 feet (7.5m) 30 feet (9m) Exhaust Restrictor Position #5 Intake Restrictor Position #6 20 feet (6m) 20 feet (6m) 15 feet (4.5m) 15 feet (4.5m) Exhaust Restrictor Position #3 Intake Restrictor Position #4 10 feet (3m) 10 feet (3m) 5 feet (1.5m) 5 feet (1.5m) 0 feet © Travis Industries 4091026 3' max. (1m) 0 feet 0 feet 100-01238_000 Installation (for qualified installers only) 21 Rear Vent Configuration Vented into Fireplace with Co-Linear Adapter • Attach the Co-Linear adapter directly to the back of the stove. Use two (2) 3” UL 441 or 1775 gas liners to vent the appliance through a code-conforming masonry or metal (zc) fireplace. All clearances to combustibles must be met and the flex vent must be vented through a noncombustible fireplace chimney. • Use a high-wind termination cap. • Vent height must be a minimum 10’ and maximum 25’. • Diffuser must be set to closed (#2) position. • Intake and exhaust restrictor must be set to the #1 (stock) position. • Do not install the intake damper plate or exhaust restrictor extender plates. High Wind Termination 46DVA-VCH p. -Tem High icone il S Liner Termination Kit (Flashing and Adapter) 46DVA-GK 3" (77mm) Dia. Flex Lines Min. 18" Co-Axial to Co-Linear Adapter 46DVA-TCL © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 22 Top Vent Configuration with Vertical Termination • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly, especially when the termination is near a demarcation line. • Diffuser set to open (stock) position. • Install the intake damper plate. • Install the exhaust restrictor extender plate. 24 ' max (7.3m) A maximum of four (4) 45° or 90° elbows may be used. Of these elbows, only one (1) may be a horizontal elbow (see illustration). 20 feet (6m) • 15 feet (4.5m) Horizontal sections require a ¼” (6mm) rise every 12” (305mm) of travel. 10 feet (3m) • 5 feet (1.5m) Use 6-5/8” Diameter Vent 0 feet • 40' max (12m) 40' max (12m) 35 feet (10.5m) 35 feet (10.5m) Exhaust Restrictor Position #5 Intake Restrictor Position #6 30 feet (9m) 30 feet (9m) 25 feet (7.5m) 25 feet (7.5m) 20 feet (6m) 20 feet (6m) Exhaust Restrictor Position #3 Intake Restrictor Position #4 15 feet (4.5m) 15 feet (4.5m) Exhaust Restrictor Position #2 Intake Restrictor Position #3 10 feet (3m) 10 feet (3m) 5 feet (1.5m) 5 feet (1.5m) 0 feet 24 ' max (7.3m) 20 feet (6m) 15 feet (4.5m) 10 feet (3m) 5 feet (1.5m) 0 feet 0 feet Horizontal Elbow Horizontal elbows are elbows placed between two horizontal sections of pipe. One 45° or 90° horizontal elbow is allowed for this configuration. © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 23 Top Vent Configuration with Horizontal Termination • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly, especially when the termination is near a demarcation line. • Diffuser set to open (stock) position). • Do not install the intake damper plate or exhaust restrictor extender plates. 24 ' max (7.3m) A maximum of four (4) 45° or 90° elbows may be used. Of these elbows, only one (1) may be a horizontal elbow (see illustration). 20 feet (6m) • 15 feet (4.5m) Horizontal sections require a ¼” (6mm) rise every 12” (305mm) of travel. 10 feet (3m) • 5 feet (1.5m) Use 6-5/8” Diameter Vent 0 feet • 21' max (6.3m) 21' max (6.3m) 20 feet (6m) 20 feet (6m) Exhaust Restrictor Position #5 Intake Restrictor Position #6 15 feet (4.5m) 15 feet (4.5m) Exhaust Restrictor Position #4 Intake Restrictor Position #4 10 feet (3m) 10 feet (3m) Exhaust Restrictor Position #1 Intake Restrictor Position #3 5 feet (1.5m) 5 feet (1.5m) Min. 2' (0.61m) Rise Required 0 feet 24 ' max (7.3m) 20 feet (6m) 15 feet (4.5m) 10 feet (3m) 5 feet (1.5m) 0 feet 0 feet Horizontal Elbow Horizontal elbows are elbows placed between two horizontal sections of pipe. One 45° or 90° horizontal elbow is allowed for this configuration. © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 24 Vent Termination Requirements (see illustration below) ! Venting terminals shall not be recessed into a wall or siding. A Minimum 9" (229mm) clearance from any door or window B Minimum 12" (305mm) above any grade, veranda, porch, deck or balcony C Minimum 1" (25mm) from outside corner walls NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. Roof Surface Roof Eaves 11" Min. (279mm) 6" Min. (152mm) D Minimum 12" (305mm) from inside corner walls NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. E Minimum 11" (279mm) clearance below unventilated soffits or roof surfaces Minimum 18" (457mm) clearance below ventilated soffits Minimum 6" (152mm) clearance below roof eaves NOTE: Vinyl surfaces require 24" (610mm) NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. F Minimum 12" (305mm) clearance below a veranda, porch, deck or balcony NOTE: Permitted only if veranda, porch, deck, or balcony is fully open on a minumum of two sides beneath the floor. NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. G Minimum 48" (1219mm) clearance from any adjacent building H Minimum 84" (2134mm) clearance above any grade when adjacent to public walkways or driveways NOTE: may not be used over a walkway or driveway shared by an adjacent building I Minimum 9" (229mm) clearance to any nonmechanical air supply inlet to the building or the combustion air inlet to any other appliance. J Minimum 36" (914mm) clearance above any mechanical air supply inlet if within 10’ (3M) horizontally K Minimum 36" (914mm) from the area above the meter/regulator (vent outlet) - this extends 15’ (4.5M) above the regulator NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. L Minimum 36" (914mm) from the meter/regulator (vent outlet) NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. M Minimum 12” (305mm) above the roof line (for vertical terminations) N Minimum 24” (610mm) horizontal clearance to any surface (such as an exterior wall) – for vertical terminations E N M E E A K G J A F H D I C L B NOTE: Measure clearances to the nearest edge of the exhaust hood. • Use the vinyl siding standoff when installing on an exterior with vinyl siding. • Vent termination must not be located where it will become plugged by snow or other material © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 25 Class A Chimney Conversion Kit (top vent configuration only) Simpson Duravent provides a conversion kit for those wishing to use an existing wood stove chimney to vent this direct vent stove. The illustration below gives an overview of this type of installation. See the instructions included with the kit for details. ! Do not exceed the maximum vertical rise (see the section "Approved Vent Configurations" starting on page 16) allowable. Remember to set the restrictor position to the correct position (based upon the vertical rise height see the chart on page 22). ! The conversion kit does not work on interior masonry chimneys. Chimney Conversion Kit A (# 931) Metalbestos 6" I.D. Security Chimneys 6" I.D. Jackes-Evans 6" I.D. Hart & Cooley 6" I.D. Pro-Jet 6" I.D. Chimney Conversion Kit B (# 932) Simpson Dura-Vent 6" I.D. Air-Jet 6" I.D. Metal-Fab 6" and 7" I.D. Amer. Metals 6" & 7" I.D. Metalbestos 7" and 8" I.D. Jackes-Evans 7" and 8" I.D. Hart & Cooley 7" and 8" I.D. Pro-Jet 7" and 8" I.D. Security Chimneys 8" I.D. Chimney Conversion Kit C (# 933) Simpson Dura-Vent 7" and 8" I.D. American Metals 8" I.D. Air-Jet 8" I.D. Metal-Fab 8" I.D. American Metals 8" I.D. Each Kit Contains: Retro Connector Retro Vertical Top Additional Required Equipment: 4" Flex (#711 or U.L. 1777) Termination (#991) Co-Axial Sections © Travis Industries Screw the Retro Vertical Top to the Flex Pipe Retro Vertical Top (screw to chimney) Cut the Flex Pipe to the chimney height plus 3" (76 mm) Type A Chimney 4" (102 mm) Aluminum Flex Pipe Retro Connector (screw to chimney) Simpson Duravent Direct Vent Pipe Sections (use adjustable section) 4091026 Screw the Retro Connector to the Flex Pipe 100-01238_000 Installation (for qualified installers only) 26 Interior Masonry Chimney Conversions (top vent configuration only) • Follow the requirements and use the equipment listed in the illustration below to install this appliance into an interior masonry chimney. • Maximum vertical rise is 40' • Minimum vertical rise is 10' • See the chart on page22 for determining the correct restrictor position. NOTE: these restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly. Interior Masonry Chimney The entire chimney system must be air-tight. Make sure to seal the flashing, clean-out, and thimble connection, and to inspect the chimney. Make sure the coaxial pipe maintains a 1” clearance to any combustible. The vent must be sealed air-tight. #991 High Wind Termination Flashing (included in #934 Masonry Conversion Kit High-T Silicoemp. ne #711 Flex Liner (4” dia.) (or other UL 1777 Gas Liner) #990 90° Elbow Co-Axial Straight Lengths Connector with Cover (included in #934 Masonry Conversion Kit) Standard Masonry Fireplace #991 High Wind Termination The entire chimney system must be air-tight. Seal the connector cover and inspect the chimney. Flashing (included in #934 Masonry Conversion Kit) p. -Tem High icone Sil #711 Flex Liner (4” dia.) (or other UL 1777 Gas Liner) Make sure the coaxial pipe maintains a 1” clearance to any combustible. The vent must be sealed air-tight. © Travis Industries Connector (included in #934 Masonry Conversion Kit) secured and sealed to block-off plate. 4091026 100-01238_000 Installation (for qualified installers only) 27 Steps for Finalizing the Installation 1. Remove the glass (see page 29). NOTE: 2. 3. 4. If using propane (LP) convert the appliance prior to installing the logs. We recommend you purge the gas line at this time (with the glass removed). This allows gas to be detected once it enters the firebox, ensuring gas does not build up. Make sure the accent light bulb is in place. NOTE: Take care to not touch the bulb with your fingers – use a cloth or paper towel). Install the four AA batteries (included in the owner’s pack) into battery holder (see the illustration below). The AA batteries act as a power backup in case the household (AC) power goes out. Install the 9v battery (included in the owner’s pack) into control panel light assembly (see the illustration below). Velcro is provided to secure the 9v battery. AA AA Ba tte Ba tte AA ry ry AA Ba tte Ba ry tte ry AA Battery Holder AA Battery Tray Swing the control cover down to access the batteries. Ba 9v tte ry Battery Holder for Control Panel Lights © Travis Industries 4091026 100-01238_000 Installation (for qualified installers only) 28 5. 6. 7. 8. 9. Install the logs (see page 31). Replace the glass. Start the heater. Leak test all gas joints. Check the air shutter following the directions below. Air Shutter Adjustment Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame. Correct Not Enough Air Flames should be blue at the base, yellow-orange on the top. Too Much Air If the flames are too tall or sooty on the ends, open the air shutter. If the flames are all blue and short, close the air shutter. Front Burner Air Shutter Control (RED) Left = Less Air Right = More Air Rear Burner Air Shutter Control Swing the control cover down to access the air shutters. (GOLD) Left = Less Air Right = More Air 10. Turn the flame adjust knob to its highest position - the flames should not contact the top of the firebox. Check the flame on low position. The flames should burn off of each burner hole. If the heater does not work correctly, contact your Travis dealer for a remedy. 11. Give this manual to the home owner for future reference and fully explain operation of this heater. © Travis Industries 4091026 100-01238_000 Finalizing the Installation (for qualified installers only) 29 Face and Glass Removal ! Make sure the gas control valve is “OFF” and the heater is cool prior to conducting service. c a Open the two latches holding the glass frame in place - follow the directions shown below Lift the stove flue cover and stove top off the stove and place it aside. Top of Firebox Latch Glass b Remove the stove front by lifting it up then forward. Place it aside. NOTE: The metal tabs on the stove front slide over the tabs on the side castings. d Lift the glass frame slightly, swing the top forward, then lift the glass frame to disengage it from the bottom guides. Catch (on glass frame) Glass Frame Glass Frame Guide Re-Attaching the Glass Frame: a) Slide the two brackets on the bottom of the glass frame into the glass frame guides (hold the glass frame at a slight angle. b) Swing the glass frame into place - you may have to lift it slightly to allow it to fit over the top of the firebox. c) Attach the upper latches (follow the instructions above in reverse). d) Replace the stove front and top. © Travis Industries 4091026 100-01238_000 30 Finalizing the Installation (for qualified installers only) Glass Frame Removal and Installation (continued) The latch can come loose from glass frame anchor. This occurs when it is turned 1/4 turn when it is disengaged. Follow the directions below to re-install the latch if it becomes loose. Hold the latch at an angle and insert it into the slot on the glass frame anchor. Latch NOTE: this slot may be at a different angle than illustrated. Top of Firebox Glass Frame Anchor Note how the washer on the latch fits behind the flange on the glass frame anchor. Once fully inserted, turn the latch until it is upright. © Travis Industries 4091026 100-01238_000 Finalizing the Installation (for qualified installers only) 31 Log Installation ! The logs are fragile, especially after being exposed to heat. Make sure the gas control valve is “OFF” and the heater is cool prior to conducting service. Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. If using propane (LP), convert the appliance before installing the logs (see page 45). The burner must be correctly positioned before installing the logs. Make sure the burner is fully seated and the pilot is properly aligned. See page 45 for details on burner removal. Rear Log Placement The rear log has two holes on the bottom. Place the log so the pins on the burner insert into the holes on the log (see photos below). © Travis Industries 4091026 100-01238_000 32 Finalizing the Installation (for qualified installers only) Left Log Placement The left log has one hole and one elevated pad on the bottom. Place the log so the pin on the burner inserts into the holes on the log and the pad inserts over the screw on the burner (see photos below). Right Log Placement The right log has two holes on the bottom. Place the log so the two pins on the burner insert into the holes on the log (see photos below). © Travis Industries 4091026 100-01238_000 Finalizing the Installation (for qualified installers only) 33 Left Twig Placement The left twig is the shorter twig(see photo below). The bottom of the twig has two holes. Place the twig so the pins on the rear and left log insert into the holes on the twig. Left Twig Right Twig Right Twig Placement The right twig has two holes in the bottom that fit over the pin on the back and right log (see photos below). The lower side of the twig rests on the right log. Place the twig as shown below. © Travis Industries 4091026 100-01238_000 34 Finalizing the Installation (for qualified installers only) Ember Placement Place a layer of embers along the edges of the burner to achieve an aesthetic appearance. Also place an ember over the screw on the right side of the burner (see photos below). Rockwool Installation The included rock wool is placed on top of the burner to enhance the glow from the burner. The rock wool works best when it is applied in a very thin, porous layer. The best method for applying the rock wool is to brush it on to the burner. Compress a clump of rockwool between your thumb and forefinger. Use a stiff brush to apply a thin layer of rockwool fibers onto the burner. Do not use the entire bag of rockwool. Use only a small amount and save the remainder. Over-use of rockwool will diminish the glow and may cause sooting or other adverse conditions. © Travis Industries 4091026 100-01238_000 Operation 35 Before You Begin Warning: Read this entire manual before you use your new stove (especially the section "Safety Precautions" on pages 4 & 5). Failure to follow the instructions may result in property damage, bodily injury, or even death. Warning: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. Location of Controls - See explanation below The on/off switch and accent light control are located on the back of the heater. ON/OFF Switch ON OFF Accent Light Control An instruction card for operating the fireplace is attached to the inside of the fireplace here. Replace it for easy reference. Swing the control cover down to access the controls. CONTINUOUS 9 VOLT PILOT FLAME ADJUST HIGH HIGH COMFORT CONTROL OFF BATTERY AA BATTERY LOW HOLDER HOLDER GREEN SMART LOW BLOWER PILOT ON/OFF Switch Accent Light 9 Volt Battery Holder Continuous Pilot -GreenSmart Pilot Flame Adjust Knob Optional Blower Control Comfort Control AA Battery Holder © Travis Industries This switch turns the stove burners on and off. This knob controls the accent lights located behind the logs. This holder contains a 9-volt battery used to light the controls This switch controls how the pilot flame works. See the section “Continuous Pilot / GreenSmart Pilot” for details. This knob controls the flame height from low to high. This knob controls the speed of the optional internal convection blower that pushes heated air into the room. This switch turns the rear burner on and off. This holder contains 4 AA batteries that allow the stove to operate during power outages. 4091026 100-01238_000 Operation 36 Starting the Stove for the First Time Burn the heater at a high setting with the blower off for an extended period (up to 48 hours). This will cure the painted surfaces. Fumes from the paint curing and oil burning off the steel will occur. This is normal. We recommend opening a window to vent the room. Condensation may appear on the glass each time you start the stove - this is normal. Blue Flames will occur on the stove when it first comes on. After fifteen minutes the flames will turn a more realistic yellow and orange color. Certain installations use a remote, thermostat, or wall switch to turn the stove on and off. If this is the case, leave the ON/OFF switch "ON". Verify the power backup and control light batteries are installed (see page 39). Turning the Stove On and Off Use the main burner switch to turn the main burner on and off. MAIN BURNER ON OFF NOTE FOR REMOTES, THERMOSTATS, OR WALL SWITCHES: The on/off switch on the stove may be required to be left in the ON or OFF position for the stove to operate. Consult your installer or dealer for details. Do not place any combustible items on top of or directly in front of the stove, even temporarily. An optional thermostat may start the stove causing a combustible item to ignite. If the stove turns on and off frequently while using a standard thermostat, you may want to adjust the flame height down until it produces just enough heat needed. Comfort Control The rear portion of the burner may be shut off to lower the heat output and flame size from the burner (this is called the comfort control). Use the comfort control switch to adjust this as desired. COMFORT CONTROL Adjusting the Flame Height This stove has an adjustable flame to tailor the look and heat output to your specific needs. It is adjusted by turning the flame adjust knob. FLAME ADJUST HIGH LOW © Travis Industries 4091026 100-01238_000 Operation 37 Accent Light HIGH OFF This stove has a built-in accent light that may be turned on and off and dimmed to your preference. Turn the knob to achieve the desired light output. LOW ACCENT LIGHT OFF LOW HIGH Adjusting the Optional Blower Speed The blower helps transfer heat from the heater into the room. It will not turn on until the heater is up to temperature (approximately 15 minutes after starting). See the illustration below for instructions on adjusting the blower speed. NOTE: With the rear burner off (comfort control), the heater may not become hot enough for the blower to turn on. HIGH OFF LOW BLOWER Continuous Pilot / GreenSmart™ Pilot Switch This stove may run with the pilot continuously running or in GreenSmart (intermittent) mode. For most homeowners, the GreenSmart mode is preferred (this saves fuel, doesn’t give off un-needed heat). However, in some situations the homeowner may prefer to switch the stove to continuous pilot. The most typical reasons for switching to continuous pilot are: CONTINUOUS PILOT GREEN SMART PILOT Very Cold Conditions – in very cold conditions you may notice that the burner does not light quickly, and the flames lift off the burner. If this is the situation, we recommend you switch to continuous pilot. This will create a slight draft in the vent, allowing the burner to light quickly and draft correctly. Excessive Condensation on Glass After Startup – certain installations may encounter excessive fogging on the window after stuartup (not just the first time the stove was started). This is an aesthetic condition that may be remedied by switching the stove to continuous pilot. Cold Glass or Stove Front – in very cold conditions you may notice that the stove front and glass become very cold. To remedy this, switch the stove to continuous pilot. Frequent On / Off Operation – if you are frequently turning the stove on and off, you may wish to leave it in continuous pilot. This allows the burner to turn on more quickly, without pilot ignition delay. © Travis Industries 4091026 100-01238_000 Operation 38 Normal Operating Sounds Extinction Pops It is not unusual, especially on Propane (LP) appliances, to experience a "pop" when the burner is shut off. The appliance may creak with change of temperature -- THIS IS NORMAL. Blower This heater has an optional blower to push heated air into the room. You will hear the sound of air movement that increases as the speed is increased. Pilot Assembly The pilot flame will make a clicking sound when starting up. If left on, it will make a slight whisper sound. Gas Control Valve As the gas control valve is turned on and off you will hear a dull clicking sound. This is the valve opening up and shutting down. GreenSmart Receiver The optional GreenSmart receiver will beep when receiving commands from the GreenSmart remote. Blower Snap Disk This part can produce a clicking sound as it turns the blower on and off. AC Adapter This device makes a light hum that is audible in close proximity. Normal Operating Odors This appliance has several areas that reach high temperatures. Dust or other particles on these areas may burn and create a burnt-paper smell. This is normal during startup. You may notice the smell is more acute if the appliance was left idle for a long period. © Travis Industries 4091026 100-01238_000 Maintenance (for qualified service personnel only) 39 Maintaining Your Stove's Appearance Painted Surfaces • Painted surfaces should be cleaned with a duster. If scratches occur, lightly sand the area with fine sandpaper. Clean the area and, with the stove cool, apply one or two thin coats of stove paint to the area (mask the area to avoid overspray). Allow the stove to dry, then turn the stove on to cure the paint (1 hour on medium). Enamel Surfaces • Use only soft cloth and water to clean enamel surfaces. To fix chips in the enamel, follow the directions below: 1) Let the stove cool. Clean the area thoroughly. 2) Shake the Travis Enamel Touch-Up thoroughly. Apply to the damaged area. Patina Surfaces • The patina finish is a “living” color and will age and antique over time. Some portions of the finish may become slightly dull in appearance, especially over the top where it becomes hot. This is normal. The only cleaning we recommend is a light dusting when the appliance is cool. DO NOT USE ANY LIQUID, CLEANER, OR ABRASIVES ON THIS FINISH. Glass • Clean the glass with soap and water (do not use abrasive cleaners). Glass removal instructions are on page 29. Battery Replacement Power Backup Batteries Four AA batteries are used as a power backup for the stove in case the household (AC) power goes out. They also power the comfort control feature. These batteries must be inserted into battery holder (make sure they contact the terminals - see the illustration below). The fireplace controller will beep once these batteries start to go dead. Replace batteries before each heating season to insure proper operation. Control Panel Light Battery LED lights and a 9v battery are used to illuminate the control panel when the concealment cover is opened. If the LED lights do not operate, replace the 9v battery (see the illustration below). Velcro is provided to secure the 9v battery. AA AA Ba tte Ba tte AA ry ry AA Ba tte Ba ry tte ry AA Battery Holder AA Battery Tray Swing the control cover down to access the batteries. Ba 9v tte ry Battery Holder for Control Panel Lights © Travis Industries 4091026 100-01238_000 Maintenance 40 (for qualified service personnel only) Accent Light Replacement An accent light is included in your stove to provide additional lighting. This bulb will burn out over time. To replace, follow the directions below: Shut off gas to the stove and let it cool for 15 minutes. Remove the glass (see page 29) and logs (see page 31). Replace the halogen bulb with the following bulb: (NOTE: .Take care to not touch the bulb with your fingers – use foam packing or paper towel to hold the bulb): 35 Watt 120 Volt T4 Halogen Bulb (G6.35 Base) Yearly Service Procedure Failure to inspect and maintain the stove may lead to improper combustion and a potentially dangerous situation. We recommend the following procedures be done by a qualified technician. 1. Turn the pilot flame to continuous. It should touch approximately 3/8" of the top of the flame sensor. If it does not, contact your dealer for service. 2. Shut off gas to the stove and let it cool for 15 minutes. Remove the glass (see page 29). 3. Remove the log set (NOTE: the logs are very fragile - see page 31). If severely deteriorated, replace. Check the logs for sooting. A small amount of soot along the bottom of the logs is normal. If excessive sooting is found, the stove will require adjustment. Contact your dealer. 4. Inspect the burner and remove any debris. 5. Make sure the burner is not warped, cracked, or damaged. Check the firebox and area around the pilot to make sure there is no warping or damage. If any problem is found, discontinue use and contact your dealer for service. Replace the log set. Clean and replace the glass. If the glass is damaged, replace. Make sure the gasket along the perimeter of the glass contacts the face of the firebox and forms an air-tight seal. If it does not, re-align or replace the gasket to insure an air-tight seal. 6. Inspect the area behind the access door. Clean if necessary. Check the gas control valve and the gas lines. If damage is found, discontinue use and contact your dealer for service. Clean the air channels, ducts, and blower (if applicable). 7. Start the main burner. After 15 minutes the flames should be orange/yellow and not touch the top of the firebox. If the pilot or main burners do not burn correctly, contact your dealer for service. Monitor blower operation. 8. Remove any debris or vegetation near the vent termination. Contact your dealer if any sooting or deterioration is found near the vent termination. © Travis Industries 4091026 100-01238_000 Maintenance (for qualified service personnel only) 41 Troubleshooting Table Problem: Main Burners Will Not Start Receiver Beeps Heater Beeps Possible Cause: Don't Call for Service Until You: The ON/OFF switch is turned to "OFF" Turn the ON/OFF switch to "ON" The remote control is not working correctly See the remote control instructions The thermostat is disconnected or set too low See "Thermostat Operation" No Propane in Tank Check Tank Level The power backup batteries are dead Replace the batteries (see page 39) The power backup batteries are dead (heater will beep once repeatedly) Replace the batteries (see page 39) The heater encountered an error when trying to start (heater beeps 3 times repeatedly) Make sure gas is turned on. Turn heater off for 5 seconds (make sure standing pilot is off) – then turn back on. The heater encountered a pilot error (heater beeps 2 times repeatedly) Contact your dealer if this occurs. Thermostat Does The ON/OFF switch is turned to "OFF" Turn the ON/OFF switch to "ON" The thermostat is set too low Check thermostat The stove is not getting electricity Check the breaker switch The stove is not up to temperature Let the stove burn for at least 15 minutes The stove has just been started This is normal - see "Starting the Stove for the First Time" Not Work Stove Will Not Distribute Heat Flames Are Too Blue Flames Are Too Short (Under 6") Comfort Control Does not Work Thin Layer of Soot Covers the Glass Improper air shutter adjustment Adjust Air Shutter - contact your dealer The flame height may be turned too low Turn the flame height to "HI" See "Adjusting the Flame Height" The AA batteries may be dead Replace the AA batteries (see page 39) The logs or coals are placed incorrectly See "Log Set Installation" Improper air shutter adjustment Adjust Air Shutter - contact your dealer © Travis Industries 4091026 100-01238_000 Maintenance 42 (for qualified service personnel only) Wiring Diagram Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Spark Rod Accent Light (s) Pilot Sensor Accent Light Rheostat Pilot Ground Optional Blower Hookup CN4 Comfort Control Valve PILOT SENSOR 120 VAC Power In DIGITAL FIREPLACE CN0 BURNER AC ADAPTER CONTROL SPARK ROD VALVE DIAGNOSTIC COMMAND POWER CN1 GROUND CN2 POWER SUPPLY Black IPI / CPI Red Black Red Blue Red Red ON / OFF Blue Red Green Orange Yellow / Green VALVE CN3 Green White Black Blue White CONTINUOUS PILOT COMFORT CONTROL GREENSMART PILOT AA BATTERY TRAY MAIN BURNER Replacement Parts List Caution: Use only Travis Industries replacement parts. Do not use substitute materials. Warning: Do not operate appliance with the glass front removed, cracked, or broken. Replacement of the glass should be done by a licensed or qualified service person. Contact your local Travis Industries Dealer for a Replacement Parts List © Travis Industries 4091026 100-01238_000 Safety Label 43 Safety Label The safety (listing) label is on the back of the stove. A copy is shown below. Tested & Listed By Eden Portland Oregon USA Vented Gas Fireplace Heater REPORT #028-S-50c-5 Certified for USA and Canada Tested to: ANSI Z21.88-2009/CSA 2.33-2009 “Vented Gas Fireplace Heater”, CGA 2.17-M91, UL 307b-1995 “Gas Burning Heating Appliances for Manufactured Homes”, and CSA P.4.1-09 Tested method for measuring annual fireplace efficiency. This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. This appliance must be installed in accordance with the current Standard CAN/CSA Z240 MH, Mobile Housing, in Canada or with the Manufactured Home Constructions and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installation Standard. This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired, the optional factory conversion kit must be used. This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home (USA only) where not prohibited by local codes. See owner’s manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. This vented gas fireplace heater is not for use with air filters. Keep burner and control compartment clean. See installation and operating instructions accompanying appliance. This appliance must be properly connected to a venting system in accordance with the manufacturer’s installation instructions. Use only approved coaxial direct vent system to vent this appliance to the exterior. See owner’s manual for approved brands of venting. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier. VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL CAUTION: Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away. Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person. Minimum Clearances to Combustibles Input Rate on “HI” (BTU/Hr)* Input Rate on “LO” (BTU/Hr)* Burner Orifice Size - Front Burner Orifice Size - Rear Alcove Min. Height (Floor to Ceiling) Alcove Max. Depth Alcove Min. Width 10” (254 mm) 5” (127 mm) 5” (127 mm) 36” (914 mm) Stove Top to Sidewall Stove Top to Backwall Stove Top to Cornerwall Glass Front to Unit L.P. N.G. 22,000 22,000 6,300 6,700 #54 #64 #52 #58 Minimum Inlet Pressure (inches W.C.) Maximum Inlet Pressure (inches W.C.) Manifold Pressure on “HI” (inches W.C.) 38-1/8” (968 mm) 24” (610 mm) 28-1/4” (718 mm) L.P. 11” 13” 11” N.G. 5.5” 7” 3.5” This appliance is equipped for use only at altitudes 0-2,000 feet (0-610m) in the USA. In Canada, 0-4500 feet (0-1370m). For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed. See the owner’s manual for information on making these changes. Manufactured by: Electrical Rating: 115v, 1.5 Amps, 60 Hz Optional Blower: #99000142 Manufacture Date: IGN 0845 2009 Jan. Apr. Jul. Oct. 2010 Feb. May Aug. Nov. 2011 Mar. Jun. Sep. Dec. © Travis Industries 4091026 4800 Harbour Pointe Blvd. SW Mukilteo, WA 98275 www.travisproducts.com 100-01238_000 Limited 7 Year Warranty 44 Register your TRAVIS INDUSTRIES, INC. Limited 7 Year Warranty online at traviswarranty.com, or complete the enclosed Warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this gas appliance (appliance is defined as the equipment manufactured by Travis Industries, Inc.) to be defect-free in material and workmanship to the original purchaser from the date of purchase as follows: Check with your dealer in advance for any costs to you when arranging a warranty call. Mileage or service charges are not covered by this warranty. This charge can vary from store to store. Component Years 1 & 2 Parts & Labor Years 3 Through 5 Parts & Labor Years 6 & 7 Parts Only Burner Assembly Burner Pan Assembly, Air Shutter Assembly, Main Burner Orifice Electrical Assembly (within heater structure): Wiring harness, snap discs, rheostat speed control Gas Control Assembly Adjustable control valve, fireplace controller, pilot assembly and pilot wiring Glass Glass (breakage from thermal shock) Ceramic Logs Log Set, Embers Gold, Nickel & Copper Plating Face & Door (see “Conditions and Exclusions” # 9) Enamel Finish Warranted against peeling or fading, excluding chipping, mechanical abrasion, or crazing. Accessories Firebacks, Power Heat Ducts, Andirons, etc… One-Way Freight Allowance One-way freight allowance on pre-authorized repair done at factory is covered. Convection Heat Exchanger Convection heat exchanger assembly Firebox Assembly Adjustable Air Restrictor, Pressure Relief Mechanisms, Glass Attachment Mechanism EXCLUDED COMPONENTS: Paint, Gasketing, and Accent Light Bulbs CONDITIONS & EXCLUSIONS 1. This new gas appliance must be installed by a qualified gas appliance technician. It must be installed, operated, and maintained at all times in accordance with the instructions in the Owner’s Manual. Any alteration, willful abuse, accident, neglect, or misuse of the product shall nullify this warranty. 2. This warranty is nontransferable, and is made to the ORIGINAL purchaser, provided that the purchase was made through an authorized TRAVIS dealer. 3. Discoloration and some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect and, therefore, not covered under warranty. The installer must ensure the appliance is burning as per the rating tag at the time of installation. Over-firing (operation above the listed BTU rate) of this appliance can cause serious damage and will nullify this warranty. 4. The warranty, as outlined within this document, does not apply to the chimney components or other Non-Travis accessories used in conjunction with the installation of this product. If in doubt as to the extent of this warranty, contact your authorized TRAVIS retailer before installation. 5. Travis Industries will not be responsible for inadequate performance caused by environmental conditions such as nearby trees, buildings, roof tops, wind, hills or mountains or negative pressure or other influences from mechanical systems such as furnaces, fans, clothes dryers, etc. 6. This Warranty is void if: a. The unit has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals. b. The unit is subject to submersion in water or prolonged periods of dampness or condensation. c. Any damage to the unit, combustion chamber, heat exchanger or other components due to water, or weather damage which is the result of, but not limited to, improper chimney/venting installation. 7. Exclusions to this 7 Year Warranty include: injury, loss of use, damage, failure to function due to accident, negligence, misuse, improper installation, alteration or adjustment of the manufacturer's settings of components, lack of proper and regular maintenance, damage incurred while the appliance is in transit, alteration, or act of God. 8. This 7 Year warranty excludes damage caused by normal wear and tear, such as paint discoloration or chipping, worn or torn gasketing, corroded or cracked logs, embers, etc. Also excluded is damage to the unit caused by abuse, improper installation, modification of the unit, drilling of the orifices, or the use of fuel other than that for which the unit is configured. Units are shipped for natural gas and must be converted to propane using the included conversion kit. Confirm fuel configuration with your installer. 9. Damage to gold or nickel surfaces caused by fingerprints, scratches, melted items , or other external sources left on the gold or nickel from the use of cleaners other than denatured alcohol is not covered in this warranty. 10. TRAVIS INDUSTRIES, INC. is free of liability for any damages caused by the appliance, as well as inconvenience expenses and materials. Incidental or consequential damages are not covered by this warranty. In some states, the exclusion of incidental or consequential damage may not apply. 11. This warranty does not cover any loss or damage incurred by the use or removal of any component or apparatus to or from the gas appliance without the express written permission of TRAVIS INDUSTRIES, INC. and bearing a TRAVIS INDUSTRIES, INC. label of approval. 12. Any statement or representation of TRAVIS products and their performance contained in TRAVIS advertising, packaging literature, or printed material is not part of this 7 year warranty. 13. This warranty is automatically voided if the appliance’s serial number has been removed or altered in any way. If the appliance is used for commercial purposes, it is excluded from this warranty. 14. No dealer, distributor, or similar person has the authority to represent or warrant TRAVIS products beyond the terms contained within this warranty. TRAVIS INDUSTRIES, INC. assumes no liability for such warranties or representations. 15. Travis Industries will not cover the cost of the removal or re-installation of hearths, facing, mantels, venting or other components. 16. If for any reason any section of this warranty is declared invalid, the balance of the warranty remains in effect and all other clauses shall remain in effect. 17. THIS 7 YEAR WARRANTY IS THE ONLY WARRANTY SUPPLIED BY TRAVIS INDUSTRIES, INC., THE MANUFACTURER OF THE APPLIANCE. ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, ARE HEREBY EXPRESSLY DISCLAIMED AND PURCHASER’S RECOURSE IS EXPRESSLY LIMITED TO THE WARRANTIES SET FORTH HEREIN. IF WARRANTY SERVICE IS NEEDED: 1. If you discover a problem that you believe is covered by this warranty, you MUST REPORT it to your TRAVIS dealer WITHIN 30 DAYS, giving them proof of purchase, the purchase date, and the model name and serial number. 2. Travis Industries has the option of either repairing or replacing the defective component. 3. If your dealer is unable to repair your appliance’s defect, he may process a warranty claim through TRAVIS INDUSTRIES, INC., including the name of the dealership where you purchased the appliance, a copy of your receipt showing the date of the appliance’s purchase, and the serial number on your appliance. At that time, you may be asked to ship your appliance, freight charges prepaid, to TRAVIS INDUSTRIES, INC. TRAVIS INDUSTRIES, INC., at its option, will repair or replace, free of charge, your TRAVIS appliance if it is found to be defective in material or workmanship within the time frame stated within this 7 year warranty. TRAVIS INDUSTRIES, INC. will return your appliance, freight charges (years 1 to 5) prepaid by TRAVIS INDUSTRIES, INC., to your regional distributor, or dealership. 4. Check with your dealer in advance for any costs to you when arranging a warranty call. Mileage or service charges are not covered by this warranty. This charge can vary from store to store. © Travis Industries 4091026 100-01238_000 Optional Equipment (for qualified installers only) 45 LP Conversion Instructions Install the conversion kit prior to installing the gas line to ensure proper gas use. 1 Remove the glass (see page 29). Remove the logs and embers (if installed - page 31). 2 Remove the burner (see below). Grasp the burner with both hands and lift it straight up and out of the firebox. © Travis Industries 4091026 100-01238_000 46 Optional Equipment (for qualified installers only) 3 Follow the directions below to replace the orifices. 1/2" Wrench b Apply thread sealant to the LP orifices prior to installation. Use the chart below to identify the correct orifices. Rear Burner Orifice Front Burner Orifice a Use a 1/2" open end wrench to unscrew the two orifices. Look here for the orifice identification c Screw each LP orifice in so the orifice protrudes 15/16" (24mm) (indicating full insertion). Front Rear NG #54 #52 LP #64 #58 15/16" 24mm © Travis Industries 4091026 100-01238_000 Optional Equipment 4 a (for qualified installers only) 47 Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice Lift the pilot hood c Remove the orifice and replace with the LP orifice. Screw the orifice all the way in and replace the pilot hood. off the pilot assembly. Orifice Identification: LP (Propane) Orifice b 35 Use a hex wrench to 35 unscrew the orifice. NG (Natural Gas) Orifice 62 5/32" Hex NOTE: when re-attaching, this pin lines up with the notch in the pilot hood. 5 Replace the firebox components. Install the logs and embers. Replace the glass. 6 Remove and discard the screws (see “a” below) holding the stock regulator in place (see “b” below). Remove the stock regulator and gasket (see “c” below). Place the LP regulator in place, making sure the pre-fitted gasket (see”c” below) is in place. NOTE: There is a label on the base of the regulator knob indicating regulator type (NG or LP). Secure the regulator with the screws included with the regulator – tighten to 25 lb-in of torque. Place the included label on the valve body where it can be easily seen to insure proper identification. NOTE: Leak test this area after the heater is installed, gas is connected, and the main burner is lit. a T-20 Torx or Slotted Screwdriver b c d 7 Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leaktest all gas connections and the gas control valve. © Travis Industries 4091026 100-01238_000 Optional Equipment 48 (for qualified installers only) GreenSmart™ Remote Control Installation Packing List Transmitter Receiver (with Cover Plate & Switch) Fan Control Module Velcro LP or NG Stepper Motor (with screws and label - attaches to Valve) Wire Harness (2) Power Leads (4) AA Batteries (inside receiver box) (2) #8 x ½” Machine Screws (2) Wire Ties Torx T-20 Wrench Wall Mount (for placing the transmitter on a wall) (2) Drywall anchors (for wall mount) (2) #8 x 3/8” Type B Screws © Travis Industries 4091026 100-01238_000 Optional Equipment 49 (for qualified installers only) Overview The GreenSmart remote includes a new wiring harness that replaces the stock wiring harness. Before installing, familiarize yourself with the stock and updated wiring diagrams (see the illustrations on this page and and following page). Stock Wiring Diagram Spark Rod Accent Light (s) Pilot Sensor Accent Light Rheostat Pilot Ground Optional Blower Hookup CN4 Comfort Control Valve PILOT SENSOR 120 VAC Power In DIGITAL FIREPLACE CN0 BURNER AC ADAPTER CONTROL SPARK ROD VALVE DIAGNOSTIC COMMAND POWER CN1 GROUND CN2 POWER SUPPLY Black IPI / CPI Red ON / OFF Blue Green Red Orange Yellow / Green VALVE CN3 Black Red Blue Red Red Green White Black Blue White CONTINUOUS PILOT COMFORT CONTROL GREENSMART PILOT © Travis Industries 4091026 AA BATTERY TRAY MAIN BURNER 100-01238_000 Optional Equipment (for qualified installers only) GreenSmart Wiring Diagram CN4 Comfort Control Valve Spark Rod Pilot Sensor PILOT SENSOR DIGITAL FIREPLACE CN0 BURNER SPARK ROD Pilot Ground CONTROL VALVE DIAGNOSTIC COMMAND GROUND CN3 POWER CN1 STEPPER MOTOR CN2 BURNER CONTROL RECEIVER VALVE Orange Green Yellow / Green Remote Receiver IPI / CPI Blue White TOP 50 CONTINUOUS PILOT (4) AA Batteries FAN CONTROL Fan Controller POWER INTERMITTENT PILOT 110V OUT FAN AUX OUT 120 VAC Power In COM Accent Light (s) Thermodisk Optional Blower(s) Accent Light Rheostat © Travis Industries 4091026 100-01238_000 Optional Equipment 51 (for qualified installers only) Installation 1 WARNING: Make sure power to the stove has been shut off prior to installation. NOTE: Refer to the wiring diagram on page 50 while making wiring harness connections. Loosen the bottom panel attachment screws (there are two on each side see Figure 1). Slide the bottom panel back and place it below the stove (see Figure 2). This allows for access to the controls under the stove. NOTE: The fireplace controller is secured to the panel with Velcro. It may be removed to allow the panel to rest on the ground. Figure 1 2 Figure 2 Remove the four screws holding the control panel to the front of the stove (see Figure 3). Carefully remove the control panel, making sure you do not disconnect any wiring (see Figure 4). Figure 4 Figure 3 © Travis Industries 4091026 100-01238_000 Optional Equipment 52 3 (for qualified installers only) Unplug the ac adapter from the power harness (see Figure 5). You can leave the ac adapter plugged into the wiring harness. Figure 5 4 Disconnect the molex connector leading to the gas control valve (see Figure 6). WARNING: The tabs on the gas control valve are fragile. Take care when removing the molex connector to not pull or damage the wires or tabs. Figure 6 5 Disconnect the two leads on the back of the control panel for the IPI / CPI switch (continuous pilot / greensmart pilot – see Figure 7). Figure 7 © Travis Industries 4091026 100-01238_000 Optional Equipment 6 Disconnect the comfort control valve connection (see Figure 8). Disconnect the burner control connector from the fireplace burner control (see Figure 9). Figure 8 7 53 (for qualified installers only) Figure 9 Disconnect the on/off switch wires (labeled ON/OFF - see Figure 10). Unscrew the on/off/battery plate from the control panel (see Figure 11). Figure 10 Figure 11 8 Pull the plate and wiring forward (see Figure 12). Un-hook the wires from the wire-locks and remove the wiring harness, plate, battery holder, and ac adapter (see Figure 13). These items may be discarded. Figure 12 © Travis Industries 4091026 Figure 13 100-01238_000 Optional Equipment 54 9 (for qualified installers only) Use the included torx wrench to remove the stock regulator (see Figure 14). The old regulator may be discarded. Figure 14 10 The stepper motor (adjustable regulator) has an installation sheet included with it – make sure to follow all of the directions. Place the stepper motor on the gas control valve (see Figure 15) – MAKE SURE IT IS CORRECTLY ORIENTED. Secure using the screws included with the motor (see Figure 16) – tighten to 25 Lb-inches. Leak test this area after installation to verify proper installation. Figure 15 Figure 16 11 Place the GreenSmart wiring harness in front of the stove, noting the position of each connector (see .Figure 17). Figure 17 © Travis Industries 4091026 100-01238_000 Optional Equipment 55 (for qualified installers only) 12 Attach the wiring harness to the burner control (see Figure 18). Attach the gas control valve molex connector (see Figure 19). Figure 18 Figure 19 13 Attach the blue and white wires to the IPI/CPI switch (see Figure 20). Connect the wiring harness to the stepper motor (see Figure 21). Figure 20 Figure 21 14 Attach the wiring harness to the comfort control valve connection (see Figure 22). Figure 22 © Travis Industries 4091026 100-01238_000 56 Optional Equipment (for qualified installers only) 15 Place the fan controller on the bottom panel as shown in Figure 23. Make sure the control module is positioned with the power cord to the right and the module at the back edge of the bottom panel. Figure 23 16 Attach the power cord from the fan controller to the AC connection (see Figure 24). Attach the connector labeled “FAN CONTROL” on the wiring harness to the fan control module (see Figure 25). MAKE SURE TO TURN THE FAN CONTROLLER ON (“-“ SYMBOL). Figure 24 Figure 25 17 Access the back of the stove and disconnect the power lead from accent light (see Figure 26). Connect the accent light wiring to the power lead included with this kit (see Figure 27). Figure 26 © Travis Industries 4091026 Figure 27 100-01238_000 Optional Equipment (for qualified installers only) 57 18 Attach the accent light power lead to the fan controller in the “AUX OUT” receptacle (see Figure 28). Figure 28 NOTE: If using the optional fan, you will want to disconnect its power lead and connect it to the extra power lead included with this kit, then connect it to the “FAN” receptacle on the fan controller. See the blower installation instructions for details. 19 Slide the receiver through the control panel and attach the “RECEIVER” connector to the receiver (see Figure 29). Attach the control panel to the stove using the four screws removed earlier (see Figure 30). Figure 29 © Travis Industries 4091026 Figure 30 100-01238_000 58 Optional Equipment (for qualified installers only) 20 Attach the receiver to the control panel with the two #8 machine screws (Figure 31). Figure 31 21 Re-attach the bottom plate to stove, taking care to prevent any wiring from being pinched (see Figure 32). Use the included wire ties, if necessary, to keep all wiring from contacting any hot or moving components. Figure 32 22 Place batteries into the receiver and transmitter (see Figure 33). Calibrate the receiver to the transmitter (see Figure 34 - use a paperclip to press the “PRG” button, let it beep, then press any button on the transmitter – the receiver should beep 5 times – see the operating instructions for further details). Figure 33 © Travis Industries 4091026 Figure 34 100-01238_000 Optional Equipment (for qualified installers only) 59 23 Place the receiver coverplate (and switch) over the receiver (see Figure 35) and attach with the two screws included with the receiver (see Figure 36) Figure 35 Figure 36 24 A wall mount is included with this kit for the remote. It may be mounted to the wall for easy access and storage. Use the included drywall anchors (and screws) to secure it to the wall (see Figure 37). Figure 37 25 Restore power to the stove and test operation of the remote (see the instructions included with the remote). © Travis Industries 4091026 100-01238_000 Index 60 Approved Vent Configurations ............................. 16 Adjusting the Blower Speed ................................. 37 Adjusting the Flame Height .................................. 36 Air Shutter Adjustment ......................................... 28 Altitude Considerations ........................................ 15 Blower Control...................................................... 37 BTU Input ............................................................. 6 BTU Output .......................................................... 6 Cap (see vent termination) ................................... 24 Chimney Cap (see vent termination) ................... 24 Clearances ........................................................... 9 Condensation on Glass ........................................ 36 Corner Installation ................................................ 9 Dimensions .......................................................... 6 Elbows .................................................................. 16 Finalizing the Installation ...................................... 27 Floor Protection ................................................... 12 Fuel ...................................................................... 4 Gas Inlet Pressure ............................................... 14 Gas Line Connection ........................................... 14 Gas Line Install .................................................... 14 Gas Smell ................................... See Inst. on Cover Glass Installation and Removal ........................... 29 Hearth Requirements ........................................... 12 Heating Specifications ......................................... 6 Horizontal Vent Termination Requirements ......... 24 © Travis Industries Installation Options .............................................. 6 Items Required for Installation ............................. 7 Leaking Gas ............................... See Inst. on Cover Listing Information ............................................... 43 Location of Controls ............................................. 35 Log Set Installation and Removal ........................ 31 Maintenance ........................................................ 39 Noise (see Normal Operating Sounds)................ 38 Normal Operating Sounds ................................... 38 Packing List.......................................................... 7 Piping Installation (see Gas Line Install) ............. 14 Restrictor Position ................................................ 16 Safety Label ......................................................... 43 Safety Precautions ............................................... 4 Starting the Stove for the First Time .................... 36 Thermostat Operation .......................................... 36 Turning the Stove On and Off .............................. 36 Vent Length (see “Vent Config.”) ......................... Vent Requirements .............................................. 11 Vertical Vent Termination Requirements ............. 24 Warnings .............................................................. 4 Warranty .............................................................. 40 Water on Glass (see Condensation) ................... 36 Weight .................................................................. 6 Wiring Diagram .................................................... 42 Yearly Service Procedure .................................... 40 4091026 100-01238_000