Download Source Technologies ST9530 Printer User Manual

Transcript
regular toner is
present, the printer
will stop all printing
and display this
message.
Macro Definition Error
Invalid decode
mode specified
Macro Definition Error
Macro ID greater
than 32767 limit.
Macro Definition Error
Macro size exceeds
available space
Non-hexadecimal Value
Received
Non-hexadecimal
value received.
Non Integer Value Received
Non integer value
received.
Integer string incorrect length
Integer string
incorrect length
MICR Definition Line Count
Error
MICR Password Error
Password Length
Error.
Secure MICR Printer User’s Guide
September 2005
The Load Flash
Resource Command
contained an invalid
character specifying
the format of the file.
Must be either a D
or S.
The resource
number in the Load
Flash Resource
Command
(&%STL...) was over
the 32767 limit.
Flash resource file
size specified in the
Load Flash
Resource Command
is too large for the
available space
remaining in the
flash module.
A command
contained a nonhexadecimal value
in a parameter.
A parameter in a
command was not
an integer.
A parameter in a
command was not
the correct length.
The number of digits
in the MICR
definition Command
is not equal to four,
or there is a nonhexadecimal
character in the
count.
Password length is
not equal to eight
toner is not available,
you must power-off
your printer and
restart the print job at
a later time when
MICR toner is
available.
Check the Command
(&%STL...) for syntax
errors.
Check the Load
Flash Resource
Command for
syntax/numbering
errors.
Format flash memory
to remove all existing
resources or upgrade
flash memory to a
larger module.
Check the Command
(&%STL, STY)
syntax for errors.
Check the command
(&%STL, STS,
STP) for syntax/
numbering errors.
Check the Command
(&%STP, STS) for
syntax/numbering
errors.
Check your software
for errors in the MICR
definition Command
(SMCP).
Check the Password
Command in your
© Source Technologies
47