Download American Standard T050.210 Thermostat User Manual

Transcript
Installation
Instructions
P
TO
N
PE
/O
T050.210
TRIM KIT for CENTRAL
THERMOSTAT with VOLUME CONTROL
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1M
ASSE 1016
M968417 REV 1.1
ROUGHING-IN DIMENSIONS
6-11/16"
CL
9-1/8"
100
1-11/16" to 2-1/2"
FINISHED
WALL
Recommended Tools
Flat Blade Screwdriver
Phillips Screwdriver
CARE INSTRUCTIONS:
To keep your new faucet looking new, please follow
these simple care instructions:
DO:
Simply rinse the faucet clean with clear water.
Dry the faucet with a soft cotton cloth.
DO NOT:
Do not use any abrasive cleaners, cloths, or
paper towels.
Do not use any cleaning agents containing
acids, polish abrasives, or harsh cleaners or
soaps.
Regular and routine cleaning will reduce the need for
heavy cleaning and polishing. If heavy cleaning is
required, the following procedures are recommended:
Remove as much surface dirt and film using clear
water and soft cotton cloth (as described above).
Use any of the following to remove tough surface
film and build-up:
Mild liquid detergents
Clear ammonia free liquid glass cleaners
Non-acidic, non-abrasive gentle liquid or fully
dissolved powder cleansers mixed according to
manufacturers directions.
Non-abrasive liquid polishers
Once clean, rinse faucet again with clear water to
thoroughly remove cleaner or polish and blot dry with
a soft cotton cloth.
Failure to follow these care instructions may
damage the Faucet's finish.
1
TRIM INSTALLATION
2
1
Push CAPS (1) over the O-RING SEALS (2).
4
3
Push ESCUTCHEON HOLDER (3) with lightly greased
O-RING SEAL (4) over CAP (1).
6
TO
5
P EN
P/O
Push on ESCUTCHEON (5) and attach with (60mm)
SCREWS (6) to valve body.
1
4
2
8
HANDLE INSTALLATION
6
3
Push TEMPERATURE-CONTROL KNOB (1) with the red stop onto KNOB
MOUNT (2). Push RING (3) onto TEMPERATURE-CONTROL KNOB (1) and
attach with SCREW (4).
7
5
6
0
Push VOLUME-CONTROL KNOB (6) onto HANDLE ADAPTER (8). Push RING (3)
onto VOLUME-CONTROL KNOB (6) and and attach with SCREW (7).
50
Press on KNOB CAPS (5).
2
1
3
3
5
4
TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION
CHECK STOP
(BLUE TO RED)
Should the hot and cold water supply pipes have been transposed making
adjustment impossible, proceed as follows:
Shut off water supply.
Remove handle and rim
Remove check stops and re-install them transposed.
Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE
CHECK STOP is now on the left.
CHECK STOP
(RED TO BLUE)
Turn the water supply back on and perform the temperature adjustment in step 4.
4
TEMPERATURE CALIBRATION
1
ARROW
"B"
Check that arrow marking B points vertically upwards. If not, push the BLACK
CLAMP (1) on the SECURING RING (2) to the right, pull off KNOB MOUNT (3)
and reinstall KNOB MOUNT (3) with arrow "B" pointing upwards.
SET HOT LIMIT STOP
The maximum mixed water temperature is set at 109 F at the factory.
This setting can be changed if desired.
4
Remove the TEMPERATURE LIMIT STOP (4) (H shaped Black Plastic part).
Reinstall it at the desired notch as indicated in the diagram to limit the maximum
mixed water temperature to 104 F or 112 F.
For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT (3) until the spout
temperature is 100 F. Check that arrow marking A on the KNOB MOUNT (3) still points
upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE (5).
Remove KNOB MOUNT (3) without turning by sliding out as indicated by the arrow.
ARROW
"A"
104
3
109
112
2
5
Reinstall the KNOB MOUNT (3) so that the arrow marking A points upwards.
Reinstall RED LOCKING DEVICE (5).
OPERATING THE VALVE
0
If the system is delivering all Hot or all Cold and no mixed water the pipes are probably transposed.
1
1
5
0
If a temperature over 100 F is desired, pull the RED STOP BUTTON (1) away from the body
of the MIXER UNIT and turn the TEMPERATURE KNOB.
This will increase the mixed water temperature up to the maximum limit previously
selected in step 4.
M968417 REV 1.1
TRIM KIT for CENTRAL
THERMOSTAT
WITH VOLUME CONTROL
MODEL NUMBER
T050.210
907090-YYY0A
CAP
953961-0070A
ESCUTCHEON
CARRIER
918327-0070A
ESCUTCHEON
CARRIER SCREWS
954026-YYY0A
VOLUME CONTROL HANDLE BASE
953946-YYY0A
ESCUTCHEON
P
TO
/O
909750-YYY0A
HANDLE RING
918428-0070A
VOLUME CONTROL SCREW
N
PE
907065-YYY0A
HANDLE CAP
051313-YYY0A
VOLUME CONTROL
HANDLE
50
6
0
953976-YYY0A
TEMPERATURE
CONTROL HANDLE BASE
918378-YYY0A
ESCUTCHEON SCREWS
909750-YYY0A
HANDLE RING
918416-0070A
TEMPERATURE SCREW
060441-YYY0A
TEMPERATURE
CONTROL HANDLE
Replace the "YYY" with
appropriate finish code
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
CHROME
POLISHED BRASS
SATIN
CHR/POL. BRASS (MIXAGE)
002
099
295
299
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2003
M968417 REV 1.1
Installation
Instructions
R520
TOP
CENTRAL THERMOSTAT
WITH VOLUME CONTROL
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1M
ASSE 1016
M968255Rev.1.1
ROUGHING-IN DIMENSIONS
CONNECTIONS ARE: 1/2" NPT
6-1/4
II
1/2" NPT
SHOWER
3-15/16
II
7
3-5/8
1/2" NPT
INLET
1/2" NPT
TUB
1/2" NPT
INLET
1-5/8 - 2-1/2
5-7/8
THERMOSTATIC BATH/
SHOWER INSTALLATION
USING A TWIN ELL, DIVERTER
SPOUT AND FIXED SHOWER
THERMOSTATIC SHOWER INSTALLATION
USING A DIVERTER VALVE, FIXED
SHOWER HEAD AND ADJUSTABLE HAND
HELD SHOWER
THERMOSTATIC SHOWER INSTALLATION USING A
DIVERTER VALVE, FIXED SHOWER HEAD, ADJUSTABLE
HAND HELD SHOWER, ON/OFF VALVE AND TWO
BODY SPRAYS
DIVERTER
VALVE
C/L
DIVERTER
VALVE
80"-86"
18"
(OPTIONAL)
ON/OFF
VALVE
TUB PORT
MUST BE
PLUGGED
4"
TWIN
ELL
TOP OF TUB RIM
BOTTOM OF TUB
IMPORTANT: WHEN NOT USING A
DIVERTER SPOUT A SEPARATE
DIVERTER VALVE MUST BE USED.
HOT
1/2"
TUB PORT MUST
BE PLUGGED
COLD
1/2"
HOT
1/2"
COLD
1/2"
TUB PORT MUST
BE PLUGGED
NOTE: MINIMUM FLOWING PRESSURE REQUIRED FOR
THIS SYSTEM OPERATING WITH ONE SHOWER HEAD
AND 2 BODY SPRAYS IS 40 PSI
1
ROUGHING-IN THE VALVE
WARNING
DO NOT SOLDER DIRECTLY TO THE VALVE BODY; THIS WILL DAMAGE
THE TEMPERATURE CONTROL ELEMENT AND CHECK STOP VALVES.
MIXED
COLD
Prepare water supplies per ROUGHING-IN DIMENSIONS. Make sure the finished wall is between
the minimum and maximum rough dimension.
Install VALVE at indicated height and depth. Make sure the "TOP" marking on the PLASTER
GUARD is up.
TOP
Connect the hot and cold water supplies. Assemble all connecting pipes. Flush lines to
remove any dirt. Connections are 1/2" NPT.
HOT
WOOD
BRACE
Assemble the connection pipe to one of the MIXED OUTLETS of the VALVE.
Cap the other MIXED OUTLET. (Tub port is fitted with a plug at the factory).
IMPORTANT! INSTALL ANY REQUIRED SHUT OFF OR DIVERTER VALVES
INTO THE PIPING SYSTEM.
1
If the CHECK STOPS (4, 5) were removed during installation,
ensure the hot and cold CHECK STOPS (4, 5) are not reversed. The
hot CHECK STOP (4) has a red top and the cold CHECK STOP (5)
has a blue top.
CHECK STOPS (4,5) are supplied in the open position.
Closing using 5/32" (4 mm) hex wrench to pressure
test and to check for leaks.
To flush lines, remove the CHECK STOPS (4,5)
and run water. If desired, the TEMPERATURE
CONTROL UNIT can be removed. Reinstall CHECK
STOPS (4,5) and CONTROL UNIT (6), if it was
removed.
Beware of Freezing. No water should remain
in the MIXING VALVE if freezing is a possibility.
Remove the CHECK STOPS (4,5) to completely
drain the MIXER UNIT (1).
2
PLUG TUB
PORT
5
CHECK STOP
(COLD BLUE)
HOT
6
Remove PLASTER GUARD (2) if still installed.
Turn on water supplies and check for leaks.
Reassemble PLASTER GUARD (2) and FINISH
WALL.
COLD
3
PLUG TUB
PORT
CHECK STOP
(HOT RED)
TOP
2
4
TEMPERATURE ADJUSTMENT
Unscrew PLASTER GUARD SCREWS and remove PLASTER GUARD.
ARROW
"B"
Check that arrow marking B points vertically upwards. If not, push the BLACK
CLAMP on the SECURING RING to the right, pull off KNOB MOUNT and reinstall
KNOB MOUNT with arrow "B" pointing upwards.
The maximum mixed water temperature is set at 109 F at the factory.
This setting can be changed if desired.
ARROW
"A"
TEMPERATURE
LIMIT STOP
104
KNOB
MOUNT
109
Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Reinstall it
at the desired notch as indicated in the diagram to limit the maximum mixed water
temperature to 104 F or 112 F.
For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT until the spout
temperature is 100 F. Check that arrow marking A on the KNOB MOUNT still points
upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE.
Remove KNOB MOUNT by pulling it towards you while standing directly in front of the valve.
BLACK
CLAMP
112
SECURING
RING
RED LOCKING
DEVICE
Reinstall the KNOB MOUNT so that the arrow marking A points upwards.
Reinstall RED LOCKING DEVICE.
3
TRANSPOSED SUPPLY PIPING
OR BACK TO BACK INSTALLATION
Should the hot and cold water supply pipes have been transposed making
adjustment impossible, proceed as follows:
Shut off water supply.
Remove handle and rim
CHECK STOP
(BLUE TO RED)
Remove check stops and re-install them transposed.
Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE
CHECK STOP is now on the left.
Turn the water supply back on and perform the temperature adjustment in step 2.
CHECK STOP
(RED TO BLUE)
M968255Rev.1.1
CENTRAL THERMOSTAT
WITH VOLUME CONTROL
MODEL NUMBER
R520
953950-0070A
CHECK STOP (COLD BLUE)
994053-0070A
CARTRIDGE
A918572-0070A
CARTRIDGE SCREW
923348-0070A
HANDLE ADAPTER
953963-0070A
953960-0070A
HANDLE EXTENSION
THERMOSTAT
CARTRIDGE
953951-0070A
CHECK STOP (HOT RED)
912647-0070A
O-RING
953957-0070A
TEMPERATURE
CALIBRATION UNIT
963434-YYY0A DEEP ROUGH KIT
( S O L D S E PA R AT E LY )
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2003
M968255Rev.1.1
Installation
Instructions
R540
TOP
3/4" CENTRAL THERMOSTAT
WITH VOLUME CONTROL
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1M
ASSE 1016
M968480
ROUGHING-IN DIMENSIONS
CONNECTIONS ARE: 3/4" NPT
6-1/4
7
II
3-15/16
II
3/4" NPT
SHOWER
3-5/8
3/4" NPT
INLET
3/4" NPT
INLET
3/4" NPT
TUB
1-5/8 - 2-1/2
5-7/8
THERMOSTATIC BATH/
SHOWER INSTALLATION
USING A TWIN ELL, DIVERTER
SPOUT AND FIXED SHOWER
THERMOSTATIC SHOWER INSTALLATION
USING A DIVERTER VALVE, FIXED
SHOWER HEAD AND ADJUSTABLE HAND
HELD SHOWER
THERMOSTATIC SHOWER INSTALLATION USING A
DIVERTER VALVE, FIXED SHOWER HEAD, ADJUSTABLE
HAND HELD SHOWER, ON/OFF VALVE AND TWO
BODY SPRAYS
DIVERTER
VALVE
C/L
DIVERTER
VALVE
80"-86"
18"
(OPTIONAL)
ON/OFF
VALVE
TUB PORT
MUST BE
PLUGGED
4"
TWIN
ELL
TOP OF TUB RIM
BOTTOM OF TUB
IMPORTANT: WHEN NOT USING A
DIVERTER SPOUT A SEPARATE
DIVERTER VALVE MUST BE USED.
HOT
3/4"
TUB PORT MUST
BE PLUGGED
COLD
3/4"
HOT
3/4"
COLD
3/4"
TUB PORT MUST
BE PLUGGED
NOTE: MINIMUM FLOWING PRESSURE REQUIRED FOR
THIS SYSTEM OPERATING WITH ONE SHOWER HEAD
AND 2 BODY SPRAYS IS 40 PSI
1
ROUGHING-IN THE VALVE
WARNING
DO NOT SOLDER DIRECTLY TO THE VALVE BODY; THIS WILL DAMAGE
THE TEMPERATURE CONTROL ELEMENT AND CHECK STOP VALVES.
MIXED
COLD
Prepare water supplies per ROUGHING-IN DIMENSIONS. Make sure the finished wall is between
the minimum and maximum rough dimension.
Install VALVE at indicated height and depth. Make sure the "TOP" marking on the PLASTER
GUARD is up.
TOP
Connect the hot and cold water supplies. Assemble all connecting pipes. Flush lines to
remove any dirt. Connections are 3/4" NPT.
HOT
Assemble the connection pipe to one of the MIXED OUTLETS of the VALVE.
Cap the other MIXED OUTLET. (Tub port is fitted with a plug at the factory).
WOOD
BRACE
IMPORTANT! INSTALL ANY REQUIRED SHUT OFF OR DIVERTER VALVES
INTO THE PIPING SYSTEM.
1
If the CHECK STOPS (4, 5) were removed during installation,
ensure the hot and cold CHECK STOPS (4, 5) are not reversed. The
hot CHECK STOP (4) has a red top and the cold CHECK STOP (5)
has a blue top.
PLUG TUB
PORT
5
CHECK STOPS (4,5) are supplied in the open position.
Closing using 5/32" (4 mm) hex wrench to pressure
test and to check for leaks.
To flush lines, remove the CHECK STOPS (4,5)
and run water. If desired, the TEMPERATURE
CONTROL UNIT can be removed. Reinstall CHECK
STOPS (4,5) and CONTROL UNIT (6), if it was
removed.
COLD
3
TOP
2
HOT
Beware of Freezing. No water should remain
in the MIXING VALVE if freezing is a possibility.
Remove the CHECK STOPS (4,5) to completely
drain the MIXER UNIT (1).
2
6
PLUG
TUB
PORT
Remove PLASTER GUARD (2) if still installed.
Turn on water supplies and check for leaks.
Reassemble PLASTER GUARD (2) and FINISH
WALL.
CHECK STOP
(COLD BLUE)
4
CHECK STOP
(HOT RED)
TEMPERATURE ADJUSTMENT
Unscrew PLASTER GUARD SCREWS and remove PLASTER GUARD.
ARROW
"B"
Check that arrow marking B points vertically upwards. If not, push the BLACK
CLAMP on the SECURING RING to the right, pull off KNOB MOUNT and reinstall
KNOB MOUNT with arrow "B" pointing upwards.
The maximum mixed water temperature is set at 109 F at the factory.
This setting can be changed if desired.
ARROW
"A"
TEMPERATURE
LIMIT STOP
104
KNOB
MOUNT
109
Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Reinstall it
at the desired notch as indicated in the diagram to limit the maximum mixed water
temperature to 104 F or 112 F.
For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT until the spout
temperature is 100 F. Check that arrow marking A on the KNOB MOUNT still points
upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE.
Remove KNOB MOUNT by pulling it towards you while standing directly in front of the valve.
BLACK
CLAMP
112
SECURING
RING
RED LOCKING
DEVICE
Reinstall the KNOB MOUNT so that the arrow marking A points upwards.
Reinstall RED LOCKING DEVICE.
3
TRANSPOSED SUPPLY PIPING
OR BACK TO BACK INSTALLATION
Should the hot and cold water supply pipes have been transposed making
adjustment impossible, proceed as follows:
Shut off water supply.
Remove handle and rim
CHECK STOP
(BLUE TO RED)
Remove check stops and re-install them transposed.
Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE
CHECK STOP is now on the left.
Turn the water supply back on and perform the temperature adjustment in step 2.
CHECK STOP
(RED TO BLUE)
M968480
3/4" CENTRAL THERMOSTAT
WITH VOLUME CONTROL
MODEL NUMBER
R540
912647-0070A
O-RING
A953971-0070A
CHECK STOP (COLD BLUE)
A994352-0070A
CARTRIDGE
923348-0070A
HANDLE ADAPTER
918428-0070A
CARTRIDGE SCREW
953963-0070A
954040-0070A
HANDLE EXTENSION
THERMOSTAT
CARTRIDGE
A953972-0070A
CHECK STOP (HOT RED)
912647-0070A
O-RING
953957-0070A
TEMPERATURE
CALIBRATION UNIT
963434-YYY0A DEEP ROUGH KIT
( S O L D S E PA R AT E LY )
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2003
M968480