Download American Standard T050.210 Thermostat User Manual
Transcript
Installation Instructions P TO N PE /O T050.210 TRIM KIT for CENTRAL THERMOSTAT with VOLUME CONTROL Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. Certified to comply with ANSI A112.18.1M ASSE 1016 M968417 REV 1.1 ROUGHING-IN DIMENSIONS 6-11/16" CL 9-1/8" 100 1-11/16" to 2-1/2" FINISHED WALL Recommended Tools Flat Blade Screwdriver Phillips Screwdriver CARE INSTRUCTIONS: To keep your new faucet looking new, please follow these simple care instructions: DO: Simply rinse the faucet clean with clear water. Dry the faucet with a soft cotton cloth. DO NOT: Do not use any abrasive cleaners, cloths, or paper towels. Do not use any cleaning agents containing acids, polish abrasives, or harsh cleaners or soaps. Regular and routine cleaning will reduce the need for heavy cleaning and polishing. If heavy cleaning is required, the following procedures are recommended: Remove as much surface dirt and film using clear water and soft cotton cloth (as described above). Use any of the following to remove tough surface film and build-up: Mild liquid detergents Clear ammonia free liquid glass cleaners Non-acidic, non-abrasive gentle liquid or fully dissolved powder cleansers mixed according to manufacturers directions. Non-abrasive liquid polishers Once clean, rinse faucet again with clear water to thoroughly remove cleaner or polish and blot dry with a soft cotton cloth. Failure to follow these care instructions may damage the Faucet's finish. 1 TRIM INSTALLATION 2 1 Push CAPS (1) over the O-RING SEALS (2). 4 3 Push ESCUTCHEON HOLDER (3) with lightly greased O-RING SEAL (4) over CAP (1). 6 TO 5 P EN P/O Push on ESCUTCHEON (5) and attach with (60mm) SCREWS (6) to valve body. 1 4 2 8 HANDLE INSTALLATION 6 3 Push TEMPERATURE-CONTROL KNOB (1) with the red stop onto KNOB MOUNT (2). Push RING (3) onto TEMPERATURE-CONTROL KNOB (1) and attach with SCREW (4). 7 5 6 0 Push VOLUME-CONTROL KNOB (6) onto HANDLE ADAPTER (8). Push RING (3) onto VOLUME-CONTROL KNOB (6) and and attach with SCREW (7). 50 Press on KNOB CAPS (5). 2 1 3 3 5 4 TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION CHECK STOP (BLUE TO RED) Should the hot and cold water supply pipes have been transposed making adjustment impossible, proceed as follows: Shut off water supply. Remove handle and rim Remove check stops and re-install them transposed. Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE CHECK STOP is now on the left. CHECK STOP (RED TO BLUE) Turn the water supply back on and perform the temperature adjustment in step 4. 4 TEMPERATURE CALIBRATION 1 ARROW "B" Check that arrow marking B points vertically upwards. If not, push the BLACK CLAMP (1) on the SECURING RING (2) to the right, pull off KNOB MOUNT (3) and reinstall KNOB MOUNT (3) with arrow "B" pointing upwards. SET HOT LIMIT STOP The maximum mixed water temperature is set at 109 F at the factory. This setting can be changed if desired. 4 Remove the TEMPERATURE LIMIT STOP (4) (H shaped Black Plastic part). Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F. For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT (3) until the spout temperature is 100 F. Check that arrow marking A on the KNOB MOUNT (3) still points upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE (5). Remove KNOB MOUNT (3) without turning by sliding out as indicated by the arrow. ARROW "A" 104 3 109 112 2 5 Reinstall the KNOB MOUNT (3) so that the arrow marking A points upwards. Reinstall RED LOCKING DEVICE (5). OPERATING THE VALVE 0 If the system is delivering all Hot or all Cold and no mixed water the pipes are probably transposed. 1 1 5 0 If a temperature over 100 F is desired, pull the RED STOP BUTTON (1) away from the body of the MIXER UNIT and turn the TEMPERATURE KNOB. This will increase the mixed water temperature up to the maximum limit previously selected in step 4. M968417 REV 1.1 TRIM KIT for CENTRAL THERMOSTAT WITH VOLUME CONTROL MODEL NUMBER T050.210 907090-YYY0A CAP 953961-0070A ESCUTCHEON CARRIER 918327-0070A ESCUTCHEON CARRIER SCREWS 954026-YYY0A VOLUME CONTROL HANDLE BASE 953946-YYY0A ESCUTCHEON P TO /O 909750-YYY0A HANDLE RING 918428-0070A VOLUME CONTROL SCREW N PE 907065-YYY0A HANDLE CAP 051313-YYY0A VOLUME CONTROL HANDLE 50 6 0 953976-YYY0A TEMPERATURE CONTROL HANDLE BASE 918378-YYY0A ESCUTCHEON SCREWS 909750-YYY0A HANDLE RING 918416-0070A TEMPERATURE SCREW 060441-YYY0A TEMPERATURE CONTROL HANDLE Replace the "YYY" with appropriate finish code HOT LINE FOR HELP For toll-free information and answers to your questions, call: 1-800 442-1902 Weekdays 8:00 a.m. to 6:00 p.m. EST CHROME POLISHED BRASS SATIN CHR/POL. BRASS (MIXAGE) 002 099 295 299 IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) Weekdays 8:00 a.m. to 7:00 p.m. EST Product names listed herein are trademarks of American Standard Inc. © American Standard Inc. 2003 M968417 REV 1.1 Installation Instructions R520 TOP CENTRAL THERMOSTAT WITH VOLUME CONTROL Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. Certified to comply with ANSI A112.18.1M ASSE 1016 M968255Rev.1.1 ROUGHING-IN DIMENSIONS CONNECTIONS ARE: 1/2" NPT 6-1/4 II 1/2" NPT SHOWER 3-15/16 II 7 3-5/8 1/2" NPT INLET 1/2" NPT TUB 1/2" NPT INLET 1-5/8 - 2-1/2 5-7/8 THERMOSTATIC BATH/ SHOWER INSTALLATION USING A TWIN ELL, DIVERTER SPOUT AND FIXED SHOWER THERMOSTATIC SHOWER INSTALLATION USING A DIVERTER VALVE, FIXED SHOWER HEAD AND ADJUSTABLE HAND HELD SHOWER THERMOSTATIC SHOWER INSTALLATION USING A DIVERTER VALVE, FIXED SHOWER HEAD, ADJUSTABLE HAND HELD SHOWER, ON/OFF VALVE AND TWO BODY SPRAYS DIVERTER VALVE C/L DIVERTER VALVE 80"-86" 18" (OPTIONAL) ON/OFF VALVE TUB PORT MUST BE PLUGGED 4" TWIN ELL TOP OF TUB RIM BOTTOM OF TUB IMPORTANT: WHEN NOT USING A DIVERTER SPOUT A SEPARATE DIVERTER VALVE MUST BE USED. HOT 1/2" TUB PORT MUST BE PLUGGED COLD 1/2" HOT 1/2" COLD 1/2" TUB PORT MUST BE PLUGGED NOTE: MINIMUM FLOWING PRESSURE REQUIRED FOR THIS SYSTEM OPERATING WITH ONE SHOWER HEAD AND 2 BODY SPRAYS IS 40 PSI 1 ROUGHING-IN THE VALVE WARNING DO NOT SOLDER DIRECTLY TO THE VALVE BODY; THIS WILL DAMAGE THE TEMPERATURE CONTROL ELEMENT AND CHECK STOP VALVES. MIXED COLD Prepare water supplies per ROUGHING-IN DIMENSIONS. Make sure the finished wall is between the minimum and maximum rough dimension. Install VALVE at indicated height and depth. Make sure the "TOP" marking on the PLASTER GUARD is up. TOP Connect the hot and cold water supplies. Assemble all connecting pipes. Flush lines to remove any dirt. Connections are 1/2" NPT. HOT WOOD BRACE Assemble the connection pipe to one of the MIXED OUTLETS of the VALVE. Cap the other MIXED OUTLET. (Tub port is fitted with a plug at the factory). IMPORTANT! INSTALL ANY REQUIRED SHUT OFF OR DIVERTER VALVES INTO THE PIPING SYSTEM. 1 If the CHECK STOPS (4, 5) were removed during installation, ensure the hot and cold CHECK STOPS (4, 5) are not reversed. The hot CHECK STOP (4) has a red top and the cold CHECK STOP (5) has a blue top. CHECK STOPS (4,5) are supplied in the open position. Closing using 5/32" (4 mm) hex wrench to pressure test and to check for leaks. To flush lines, remove the CHECK STOPS (4,5) and run water. If desired, the TEMPERATURE CONTROL UNIT can be removed. Reinstall CHECK STOPS (4,5) and CONTROL UNIT (6), if it was removed. Beware of Freezing. No water should remain in the MIXING VALVE if freezing is a possibility. Remove the CHECK STOPS (4,5) to completely drain the MIXER UNIT (1). 2 PLUG TUB PORT 5 CHECK STOP (COLD BLUE) HOT 6 Remove PLASTER GUARD (2) if still installed. Turn on water supplies and check for leaks. Reassemble PLASTER GUARD (2) and FINISH WALL. COLD 3 PLUG TUB PORT CHECK STOP (HOT RED) TOP 2 4 TEMPERATURE ADJUSTMENT Unscrew PLASTER GUARD SCREWS and remove PLASTER GUARD. ARROW "B" Check that arrow marking B points vertically upwards. If not, push the BLACK CLAMP on the SECURING RING to the right, pull off KNOB MOUNT and reinstall KNOB MOUNT with arrow "B" pointing upwards. The maximum mixed water temperature is set at 109 F at the factory. This setting can be changed if desired. ARROW "A" TEMPERATURE LIMIT STOP 104 KNOB MOUNT 109 Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F. For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT until the spout temperature is 100 F. Check that arrow marking A on the KNOB MOUNT still points upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE. Remove KNOB MOUNT by pulling it towards you while standing directly in front of the valve. BLACK CLAMP 112 SECURING RING RED LOCKING DEVICE Reinstall the KNOB MOUNT so that the arrow marking A points upwards. Reinstall RED LOCKING DEVICE. 3 TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION Should the hot and cold water supply pipes have been transposed making adjustment impossible, proceed as follows: Shut off water supply. Remove handle and rim CHECK STOP (BLUE TO RED) Remove check stops and re-install them transposed. Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE CHECK STOP is now on the left. Turn the water supply back on and perform the temperature adjustment in step 2. CHECK STOP (RED TO BLUE) M968255Rev.1.1 CENTRAL THERMOSTAT WITH VOLUME CONTROL MODEL NUMBER R520 953950-0070A CHECK STOP (COLD BLUE) 994053-0070A CARTRIDGE A918572-0070A CARTRIDGE SCREW 923348-0070A HANDLE ADAPTER 953963-0070A 953960-0070A HANDLE EXTENSION THERMOSTAT CARTRIDGE 953951-0070A CHECK STOP (HOT RED) 912647-0070A O-RING 953957-0070A TEMPERATURE CALIBRATION UNIT 963434-YYY0A DEEP ROUGH KIT ( S O L D S E PA R AT E LY ) HOT LINE FOR HELP For toll-free information and answers to your questions, call: 1-800 442-1902 Weekdays 8:00 a.m. to 8:00 p.m. EST IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) Weekdays 8:00 a.m. to 7:00 p.m. EST Product names listed herein are trademarks of American Standard Inc. © American Standard Inc. 2003 M968255Rev.1.1 Installation Instructions R540 TOP 3/4" CENTRAL THERMOSTAT WITH VOLUME CONTROL Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. Certified to comply with ANSI A112.18.1M ASSE 1016 M968480 ROUGHING-IN DIMENSIONS CONNECTIONS ARE: 3/4" NPT 6-1/4 7 II 3-15/16 II 3/4" NPT SHOWER 3-5/8 3/4" NPT INLET 3/4" NPT INLET 3/4" NPT TUB 1-5/8 - 2-1/2 5-7/8 THERMOSTATIC BATH/ SHOWER INSTALLATION USING A TWIN ELL, DIVERTER SPOUT AND FIXED SHOWER THERMOSTATIC SHOWER INSTALLATION USING A DIVERTER VALVE, FIXED SHOWER HEAD AND ADJUSTABLE HAND HELD SHOWER THERMOSTATIC SHOWER INSTALLATION USING A DIVERTER VALVE, FIXED SHOWER HEAD, ADJUSTABLE HAND HELD SHOWER, ON/OFF VALVE AND TWO BODY SPRAYS DIVERTER VALVE C/L DIVERTER VALVE 80"-86" 18" (OPTIONAL) ON/OFF VALVE TUB PORT MUST BE PLUGGED 4" TWIN ELL TOP OF TUB RIM BOTTOM OF TUB IMPORTANT: WHEN NOT USING A DIVERTER SPOUT A SEPARATE DIVERTER VALVE MUST BE USED. HOT 3/4" TUB PORT MUST BE PLUGGED COLD 3/4" HOT 3/4" COLD 3/4" TUB PORT MUST BE PLUGGED NOTE: MINIMUM FLOWING PRESSURE REQUIRED FOR THIS SYSTEM OPERATING WITH ONE SHOWER HEAD AND 2 BODY SPRAYS IS 40 PSI 1 ROUGHING-IN THE VALVE WARNING DO NOT SOLDER DIRECTLY TO THE VALVE BODY; THIS WILL DAMAGE THE TEMPERATURE CONTROL ELEMENT AND CHECK STOP VALVES. MIXED COLD Prepare water supplies per ROUGHING-IN DIMENSIONS. Make sure the finished wall is between the minimum and maximum rough dimension. Install VALVE at indicated height and depth. Make sure the "TOP" marking on the PLASTER GUARD is up. TOP Connect the hot and cold water supplies. Assemble all connecting pipes. Flush lines to remove any dirt. Connections are 3/4" NPT. HOT Assemble the connection pipe to one of the MIXED OUTLETS of the VALVE. Cap the other MIXED OUTLET. (Tub port is fitted with a plug at the factory). WOOD BRACE IMPORTANT! INSTALL ANY REQUIRED SHUT OFF OR DIVERTER VALVES INTO THE PIPING SYSTEM. 1 If the CHECK STOPS (4, 5) were removed during installation, ensure the hot and cold CHECK STOPS (4, 5) are not reversed. The hot CHECK STOP (4) has a red top and the cold CHECK STOP (5) has a blue top. PLUG TUB PORT 5 CHECK STOPS (4,5) are supplied in the open position. Closing using 5/32" (4 mm) hex wrench to pressure test and to check for leaks. To flush lines, remove the CHECK STOPS (4,5) and run water. If desired, the TEMPERATURE CONTROL UNIT can be removed. Reinstall CHECK STOPS (4,5) and CONTROL UNIT (6), if it was removed. COLD 3 TOP 2 HOT Beware of Freezing. No water should remain in the MIXING VALVE if freezing is a possibility. Remove the CHECK STOPS (4,5) to completely drain the MIXER UNIT (1). 2 6 PLUG TUB PORT Remove PLASTER GUARD (2) if still installed. Turn on water supplies and check for leaks. Reassemble PLASTER GUARD (2) and FINISH WALL. CHECK STOP (COLD BLUE) 4 CHECK STOP (HOT RED) TEMPERATURE ADJUSTMENT Unscrew PLASTER GUARD SCREWS and remove PLASTER GUARD. ARROW "B" Check that arrow marking B points vertically upwards. If not, push the BLACK CLAMP on the SECURING RING to the right, pull off KNOB MOUNT and reinstall KNOB MOUNT with arrow "B" pointing upwards. The maximum mixed water temperature is set at 109 F at the factory. This setting can be changed if desired. ARROW "A" TEMPERATURE LIMIT STOP 104 KNOB MOUNT 109 Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F. For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT until the spout temperature is 100 F. Check that arrow marking A on the KNOB MOUNT still points upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE. Remove KNOB MOUNT by pulling it towards you while standing directly in front of the valve. BLACK CLAMP 112 SECURING RING RED LOCKING DEVICE Reinstall the KNOB MOUNT so that the arrow marking A points upwards. Reinstall RED LOCKING DEVICE. 3 TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION Should the hot and cold water supply pipes have been transposed making adjustment impossible, proceed as follows: Shut off water supply. Remove handle and rim CHECK STOP (BLUE TO RED) Remove check stops and re-install them transposed. Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE CHECK STOP is now on the left. Turn the water supply back on and perform the temperature adjustment in step 2. CHECK STOP (RED TO BLUE) M968480 3/4" CENTRAL THERMOSTAT WITH VOLUME CONTROL MODEL NUMBER R540 912647-0070A O-RING A953971-0070A CHECK STOP (COLD BLUE) A994352-0070A CARTRIDGE 923348-0070A HANDLE ADAPTER 918428-0070A CARTRIDGE SCREW 953963-0070A 954040-0070A HANDLE EXTENSION THERMOSTAT CARTRIDGE A953972-0070A CHECK STOP (HOT RED) 912647-0070A O-RING 953957-0070A TEMPERATURE CALIBRATION UNIT 963434-YYY0A DEEP ROUGH KIT ( S O L D S E PA R AT E LY ) HOT LINE FOR HELP For toll-free information and answers to your questions, call: 1-800 442-1902 Weekdays 8:00 a.m. to 8:00 p.m. EST IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) Weekdays 8:00 a.m. to 7:00 p.m. EST Product names listed herein are trademarks of American Standard Inc. © American Standard Inc. 2003 M968480