Download Alcatel-Lucent 4504 Switch User Manual
Transcript
Open Problem Reports and Feature Exceptions PR 107287 During "update lanpower all" on a stack of 8 OS6850-P24/48, you might see the following error message: THU OCT 12 14:06:27 : LANPOWER (108) error message: +++ Unable to Read S19 Response! Reset Daughter Module! Done THU OCT 12 14:48:59 : LANPOWER (108) error message: +++ Unable to Read BOOT_SECTION_RESPONSE Response! +++ General Programming Error! Workaround: Do a "lanpower start" on the NI which failed the firmware update. Once lanpower failed to start which is expected, you then try to "update lanpower <slot>" again on that specific NI. Redundancy / Hot Swap Hot Swap Time Limitations for OmniSwitch 9000 • All removals of NI modules must have a 30 second interval before initiating another hot swap activity. • All insertions of NI modules must have a 3 minute interval before initiating another hot swap activity. • All hot swaps of CMM modules must have a 10 minute interval before initiating another hot swap, reload or takeover activity. • All takeovers must have a 10 minute interval before following with another hot swap, reload or take- over activity.Problem Reports Problem Reports PR 91287 After takeover, the new primary CMM does not keep the DOS statistics held by the previous primary CMM. Workaround: There is no known workaround at this time. PR 95840 The whole chassis will reload if more than half of NIs are hot swapped in and out of the chassis at roughly the same time. Workaround: If hot swap of NIs is required, a user may have to wait until a previous NI has been booted first, and then hot swap the next NI. page 84 OmniSwitch 6800/6850/9000—Release 6.1.3.R01