Download ALCO EC3-33x User manual

Transcript
EC3-33x Coldroom Controller with EX5
EC3-33x
User Manual
A.6.5.063E - Rev 4
LIST OF PARAMETERS
Parameter
DISPLAY PARAMETERS
Value to be shown on display
No alarms
Temperature unit
Decimal point
Display during defrost
Temperature alignment for /1 = 0
Values
Min Max Unit Def
0
11
0
0
1 flag 0
0
1 flag 0
0
1 flag 0
0
2 flag 0
-20.0+20.0 K 0.0
F
F1
F2
F3
F4
F5
Fd
Ft
Parameter
FAN PARAMETERS
Fan start-up sequence after defrost
Fan status during no cooling
Fan status during defrost
Fan stop delay time by no cooling
Fan status during cleaning
Fan start delay time after defrost
Fan on temperature after defrost
Min
0
0
0
0
0
0
-40
Values
Max Unit Def
4
0
2
0
1 flag 0
30 min 0
1 flag 0
30 min 0
40 °C
0
A
A0
A1
A2
A3
c
c0
c1
c2
c3
COMPRESSOR PARAMETERS
Delay first start of compressor
Cycle time of compressor
Min. stop time of compressor
Min. run time of compressor
Min
0
0
0
0
Max
15
15
15
15
r
r0
r1
r2
r3
u
u0
u1
u2
u3
u4
u5
u6
u7
u8
uu
ut
SUPERHEAT PARAMETERS
Refrigerant
Correction glide / pressure drop
MOP control
MOP temperature
Control mode
Superheat init set-point
Superheat set-point min
Superheat set-point max
Saturation temperature
Start opening
Valve type
Min Max
0
4
-20.0 20.0
0
1
-40 40
0
2
u6 u7
3
u7
u6 20
0
1
50 100
0
3
H
H2
OTHER PARAMETERS
Min Max Unit Def
Keyboard and IR remote control
0
3
3
0 = all disabled (Caution, access to controller only via LON networ
possible)
1 = Keyboard enabled
2 = IR remote control enabled
3 = Keyboard and IR remote control enabled
IR remote control access code
0 199 0
Password
0 199 12
/
/1
/2
/5
/6
/7
/C
ALARM PARAMETERS
Min Max Unit Def
Mean factor alarm temperature
0 100 % 100
Low temperature alarm delay
0 180 min 5
High temperature alarm delay
0 180 min 5
High temperature alarm delay after
0 180 min 10
defrost
Ad Door alarm delay
0 180 min 2
AH High temperature alarm threshold
AL 70 °C/K 40
AL Low temperature alarm threshold
-50 AH °C/K -40
At Type of alarm threshold values
0
1 flag 0
0 = absolute temperatures °C
1 = relative temperatures K to setpoint
Min Max Unit Def
0
15 flag 6
-40 r2 °C -40
r1 60 °C 40
0
1 flag 1
r4
r6
r7
r8
r9
rd
St
THERMOSTAT PARAMETERS
Door contact function
Min set-point value
Max set-point value
Day / night control
0 = off
1 = on
Thermostat mode
Set-point night operation
Difference night operation
Mean factor day operation
Mean factor night operation
Difference day operation
Set-point day operation
0
r1
0.1
0
0
0.1
r1
4
r2
20.0
100
100
20.0
r2
1
°C 4.0
K 2.0
% 100
% 50
K 2.0
°C 2.0
d
d0
d1
d2
d3
d4
d5
d6
d7
d8
d9
dd
dH
dt
dP
dI
dU
DEFROST PARAMETERS
Defrost mode
Termination by time / temperature
Defrost termination sensor
Pulsed defrost
Defrost at power up
Delay for power up defrost
Pump down delay
Drain delay
Injection delay
Demand defrost mode
Pulsed defrost difference
Pulsed defrost set-point
Defrost termination temperature
Maximal defrost duration
Defrost interval
Start up delay by synchronization
Min
0
0
0
0
0
0
0
0
0
0
1
-40
-40
0
0
0
Max
2
3
1
1
1
180
180
180
180
2
20
dt
90
180
192
180
Unit Def
1
0
flag 1
flag 0
flag 0
min 0
sec 0
min 2
sec 0
0
K
2
°C
5
°C
8
min 30
h
8
min 30
H3
H5
Unit Def
min 0
min 0
min 0
min 0
Unit
K
flag
°C
K
K
K
flag
%
-
3
Emerson Electric GmbH & Co - ALCO CONTROLS - Heerstr. 111 - D-71332 Waiblingen - Germany - Tel.: ..49 (0) 7151 509 0 - Fax: 49 (0) 7151 509 200
Def
3
0.0
0
0
1
6
3
15
1
100
0