EC3-33x Coldroom Controller with EX5 EC3-33x User Manual A.6.5.063E - Rev 4 LIST OF PARAMETERS Parameter DISPLAY PARAMETERS Value to be shown on display No alarms Temperature unit Decimal point Display during defrost Temperature alignment for /1 = 0 Values Min Max Unit Def 0 11 0 0 1 flag 0 0 1 flag 0 0 1 flag 0 0 2 flag 0 -20.0+20.0 K 0.0 F F1 F2 F3 F4 F5 Fd Ft Parameter FAN PARAMETERS Fan start-up sequence after defrost Fan status during no cooling Fan status during defrost Fan stop delay time by no cooling Fan status during cleaning Fan start delay time after defrost Fan on temperature after defrost Min 0 0 0 0 0 0 -40 Values Max Unit Def 4 0 2 0 1 flag 0 30 min 0 1 flag 0 30 min 0 40 °C 0 A A0 A1 A2 A3 c c0 c1 c2 c3 COMPRESSOR PARAMETERS Delay first start of compressor Cycle time of compressor Min. stop time of compressor Min. run time of compressor Min 0 0 0 0 Max 15 15 15 15 r r0 r1 r2 r3 u u0 u1 u2 u3 u4 u5 u6 u7 u8 uu ut SUPERHEAT PARAMETERS Refrigerant Correction glide / pressure drop MOP control MOP temperature Control mode Superheat init set-point Superheat set-point min Superheat set-point max Saturation temperature Start opening Valve type Min Max 0 4 -20.0 20.0 0 1 -40 40 0 2 u6 u7 3 u7 u6 20 0 1 50 100 0 3 H H2 OTHER PARAMETERS Min Max Unit Def Keyboard and IR remote control 0 3 3 0 = all disabled (Caution, access to controller only via LON networ possible) 1 = Keyboard enabled 2 = IR remote control enabled 3 = Keyboard and IR remote control enabled IR remote control access code 0 199 0 Password 0 199 12 / /1 /2 /5 /6 /7 /C ALARM PARAMETERS Min Max Unit Def Mean factor alarm temperature 0 100 % 100 Low temperature alarm delay 0 180 min 5 High temperature alarm delay 0 180 min 5 High temperature alarm delay after 0 180 min 10 defrost Ad Door alarm delay 0 180 min 2 AH High temperature alarm threshold AL 70 °C/K 40 AL Low temperature alarm threshold -50 AH °C/K -40 At Type of alarm threshold values 0 1 flag 0 0 = absolute temperatures °C 1 = relative temperatures K to setpoint Min Max Unit Def 0 15 flag 6 -40 r2 °C -40 r1 60 °C 40 0 1 flag 1 r4 r6 r7 r8 r9 rd St THERMOSTAT PARAMETERS Door contact function Min set-point value Max set-point value Day / night control 0 = off 1 = on Thermostat mode Set-point night operation Difference night operation Mean factor day operation Mean factor night operation Difference day operation Set-point day operation 0 r1 0.1 0 0 0.1 r1 4 r2 20.0 100 100 20.0 r2 1 °C 4.0 K 2.0 % 100 % 50 K 2.0 °C 2.0 d d0 d1 d2 d3 d4 d5 d6 d7 d8 d9 dd dH dt dP dI dU DEFROST PARAMETERS Defrost mode Termination by time / temperature Defrost termination sensor Pulsed defrost Defrost at power up Delay for power up defrost Pump down delay Drain delay Injection delay Demand defrost mode Pulsed defrost difference Pulsed defrost set-point Defrost termination temperature Maximal defrost duration Defrost interval Start up delay by synchronization Min 0 0 0 0 0 0 0 0 0 0 1 -40 -40 0 0 0 Max 2 3 1 1 1 180 180 180 180 2 20 dt 90 180 192 180 Unit Def 1 0 flag 1 flag 0 flag 0 min 0 sec 0 min 2 sec 0 0 K 2 °C 5 °C 8 min 30 h 8 min 30 H3 H5 Unit Def min 0 min 0 min 0 min 0 Unit K flag °C K K K flag % - 3 Emerson Electric GmbH & Co - ALCO CONTROLS - Heerstr. 111 - D-71332 Waiblingen - Germany - Tel.: ..49 (0) 7151 509 0 - Fax: 49 (0) 7151 509 200 Def 3 0.0 0 0 1 6 3 15 1 100 0