Follow/Stay Zones Figure 18: Delayed Fire Zone Sections [001] to [016]: Zones 1 to 16, 3-digit # = 004 Follow/Stay zones function as follows: • • All zones defined as Follow/Stay zones become Follow zones (refer to Follow Zones on page 13) when the Magellan system is Regular armed. All zones defined as Follow/Stay zones become Stay zones when the Magellan system is Stay or Instant armed. Instant Zones Sections [001] to [016]: Zones 1 to 16, 3-digit # = 005 When an armed Instant zone opens, the console immediately generates an alarm. Instant zones are commonly used for windows, patio doors, skylights and other perimeter type zones. Instant/Stay Zones Sections [001] to [016]: Zones 1 to 16, 3-digit # = 006 Instant/Stay zones function as follows: • • All zones defined as Instant/Stay zones become Instant zones (refer to Instant Zones on page 14) when the Magellan system is Regular armed. All zones defined as Instant/Stay zones become Stay zones when the Magellan system is Stay or Instant armed. Standard 24Hr. Fire Zones Sections [001] to [016]: Zones 1 to 16, 3-digit # = 007 Whenever a Standard 24Hr. Fire zone opens, whether it is armed or disarmed, the console will generate the following: 24Hr. Burglary Zones • Whenever a 24Hr. Burglary zone opens, whether the system is armed or disarmed, the console will immediately generate an alarm. • The console can send the corresponding Alarm Report Code from sections [187] to [190]. Alarms are always audible regardless of other settings. Fire alarms generate an intermittent (pulsed) bell/siren output signal as shown in Figure 17 on page 14. Figure 17: Bell/Siren Output during a Fire Alarm Sections [001] to [016]: Zones 1 to 16, 3-digit # = 009 24Hr. Hold-up Zones Sections [001] to [016]: Zones 1 to 16, 3-digit # = 010 When a 24Hr. Hold-up zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Hold-up alarm (see Appendix 1: Automatic Report Code List on page 35). 24Hr. Buzzer Zones Sections [001] to [016]: Zones 1 to 16, 3-digit # = 011 Delayed Fire Zones Sections [001] to [016]: Zones 1 to 16, 3-digit # = 008 When a Delayed 24Hr. Fire zone opens, whether it is armed or disarmed, the console will react as shown in Figure 18 on page 14. Delayed 24Hr. Fire zones are commonly used in residential homes where a smoke detector often generates false alarms (i.e., burning bread, etc.). This zone definition is particularly useful when a user wishes to be notified when something such as a safe or locker within the home has been accessed (i.e., a child accessing a valuable collection). This zone definition functions as follows: • • • 14 Whenever a 24Hr. Buzzer zone opens, whether the console is armed or disarmed, the console sets off the keypad’s buzzer to indicate that the zone was breached. The console will report the alarm, but will not enable the bell/ siren output. Enter any valid Access code on the keypad to stop the buzzer. Reference & Installation Manual