Download Simrad PI TWIN SPREAD - QUICK REFERENCE GUIDE REV B Installation manual
Transcript
Installation of sensor adapters STEP 4: Dismantle the sensor adapters Remove the sensor adapters’ rubber inserts (two) before performing any hot work. Locking devices and internal plastic spacers may remain attached. Note: Over heating of either the sensor adapters or doors must be avoided though out the installation procedure. Note: The two rubber inserts provided must not be replaced with any other types or designs. It is essential that these inserts provide a secure cradle for the sensors, but they must also allow for free water circulation to allow the sensor’s water switch to engage. Also, the design of the inserts allows sand and mud to flow out when the trawl doors are pulled up from the water. 851-165187 / Rev.A 187