Transcript
® above the ceiling 11/2 minutes of penalty time is added to Required Stop Time. CO FT Z. C. C. Z. DE NO DECO O2 FT Fig. 58 - Delayed Violation (> 5 minutes above Stop) NO DECO O2 FT Z. C. FT Fig. 59 - Delayed Violation (Required Stop >60FT/18M) 50 DELAYED VIOLATION MODE Three conditions cause the Data Plus 2 to enter the Delayed Violation Mode: 1. You remain above the required Decompression Ceiling Stop Depth for 'more than 5 minutes' (Fig. 58). You would then need to follow the Stop Depths and Times toward the surface as the Tissue Loading Bar Graph recedes into the caution zone. CO C. Z. DE The added penalty decompression time will have to be 'worked off' first, before obtaining off-gassing credit. Once the penalty time is worked-off, and off-gassing credit begins, required decompression Stop Depths and Time will decrease toward zero, then the Tissue Loading Bar Graph will recede into the caution zone and the Data Plus 2 will revert to the No Decompression Dive Mode. 2. Your decompression requires a ceiling Stop Depth 'between' 60 feet (18 meters) and 70 feet (21 meters). In this situation the Tissue Loading Bar Graph will flash (Fig. 59). Total Ascent Time needed to get back to the surface will still be displayed. You must ascend to just deeper than 60 feet (18 meters) staying as close to 60 feet (18 meters) as possible without causing the Total Ascent Time display to