Download Quantum Data 700A User guide
Transcript
Safety Product Mechanical Electrical Information Information Installation Installation 14 Getting Started Basic Running parameters the Motor UL Information 14.5 Quantum MP frame size 1 drives have been assessed to comply with both ULus and cUL requirements.Control Techniques UL file number is E58592. Confirmation of UL listing can be found at website: www.ul.com Quantum MP frame size 2 drives have been assessed to comply with UL508A open panel requirements. 14.1 Optimization Common UL Information Conformity: The drive conforms to UL listing requirements only when the following are observed: 1. The drive is installed in a type 1 enclosure, or better as defined in UL 50. 2. The ambient temperature does not exceed 40°C when the drive is operating. 3. The terminal torques specified in section 3.8.3 Torque settings on page 23 are to be used. 4. The drive is to be installed in to a pollution degree 2 environment. 5. If the drive control stage is supplied by an external power supply, (+24V), the external power supply must be a UL class 2 power supply. 6. Fuses sized as specified in the various tables in Chapter 4 Electrical Installation on page 26 are to be used. Fusing is to incorporate a Class J fuse in line with a semiconductor fuse as specified. 7. Field wiring is to be class 1 75°C (167°F) copper wire only. • • • • • • • • • • • • • • • • • • • • • • • SMARTCARD Onboard Advanced Technical UL Diagnostics Operation PLC Parameters Data Information UL Listed accessories SM-Keypad MP-Keypad SM-DeviceNet SM-PROFIBUS-DP-V1 SM-INTERBUS SM-CANopen SM-Ethernet SM-EtherCAT SM-Register SM-Applications Lite-V2 SM-Applications Plus SM-Universal Encoder Plus SM-Encoder Plus SM-Encoder Output Plus SM-I/O Plus SM-I/O 32 SM-I/O Lite SM-I/O Timer SM-I/O PELV SM-I/O 120V SM-I/O 24V Protected 15-way D-type converter Single ended encoder interface Motor overload protection All models incorporate an internal overload protection model for the motor load that does not require the use of an external or remote overload protection device. The protection level is adjustable, and the method of adjustment is provided with the instructions for the product. Maximum current overload is dependant on the values entered into the current limit parameters (motoring current limit, regen current limit and symmetrical current limit entered as percentage) and the motor rated current parameter (entered in amperes). The duration of the overload is dependant on motor thermal time constant (variable up to a maximum of 3000 seconds). The default overload protection is set such that the product is capable of 150% of the current value entered into the motor rated current parameter (Pr 5.07 (SE07, 0.28)) for 30 seconds. The product also provides user terminal default functionality such that the product can be connected to a motor thermistor to protect the motor in terms of temperature, in the event of a motor cooling fan failure. Over speed protection The drive provides overspeed protection. However, it does not provide the level of protection afforded by an independent high integrity overspeed protection device. 14.2 AC supply specification The maximum UL supply voltage is 600 Vac. The drive is suitable for use in a circuit capable of delivering not more than 100,000 rms symmetrical Amperes at 575V (size 1A and 1B). 14.3 Maximum continuous output current The drive models are listed as having the maximum continuous output currents (FLC) shown in Chapter 2.2 Ratings on page 6. 14.4 Safety label The safety label supplied with connectors and mounting brackets must be placed on a fixed part of the drive enclosure where it can be seen clearly by maintenance personnel for UL compliance.The label clearly states "CAUTION risk of electric shock power down at least 10 minutes before removing cover". 166 www.emersonct.com Quantum MP User Guide Issue: A3