Download VDC Electronics 12117 Specifications
Transcript
GE Data Sheet 12V TLynxTM 20A: Non-Isolated DC-DC Power Modules 4.5Vdc –14Vdc input; 0.69Vdc to 5.5Vdc output; 20A Output Current Characteristic Curves (continued) The following figures provide typical characteristics for the 12V TLynxTM at 3.3Vo and at 25oC. 22 100 20 18 OUTPUT CURRENT, Io (A) EFFICIENCY, η (%) 95 90 Vin=4.5V Vin=12V 85 Vin=14V 80 75 0 5 10 15 2m/s (400LFM) 10 Standard Part (85°C) 8 6 Ruggedized (D) Part (105°C) Figure 29. Typical Start-up Using On/Off Voltage (Io = Io,max). May 2, 2013 55 65 75 85 95 105 VO (V) (200mV/div) IO (A) (5Adiv) OUTPUT VOLTAGE VIN (V) (5V/div) Figure 28. Transient Response to Dynamic Load Change from 0% 50% to 0%. VO (V) (1V/div) TIME, t (1ms/div) 45 TIME, t (20μs /div) INPUT VOLTAGE Figure 27. Typical output ripple and noise (VIN = 12V, Io = Io,max). 35 Figure 26. Derating Output Current versus Ambient Temperature and Airflow. OUTPUT VOLTAGE TIME, t (1μs/div) VO (V) (1V/div) 12 AMBIENT TEMPERATURE, TA OC OUTPUT CURRENT, VO (V) (20mV/div) OUTPUT VOLTAGE Figure 25. Converter Efficiency versus Output Current. OUTPUT VOLTAGE 1m/s (200LFM) 14 25 20 OUTPUT CURRENT, IO (A) VON/OFF (V) (2V/div) 0.5m/s (100LFM) 4 70 ON/OFF VOLTAGE NC 16 TIME, t (1ms/div) Figure 30. Typical Start-up Using Input Voltage (VIN = 12V, Io = Io,max). ©2013 General Electric Company. All rights reserved. Page 11