Download Windsor iExtract 26 Duo Operating instructions
Transcript
Operations Solution Tank 1. Remove the recovery tank lid. Recovery Tank Lid 2. Pull the solution drain hose from its mounting pocket. Unscrew the cap, then lower hose in direction of drain. 3. Remove the solution tank cap. 4. Flush the solution tank out with clean water and run several gallons of clean water through systems. Do not use water hotter than 140°F (60°C) to clean tank. Damage may occur. 5. If machine is to be stored, leave solution cap off. NOTE: Never allow solution to remain in tank. Damage to tank, seals and valves could occur. Recovery Drain Hose Solution Drain Hose Emptying and Cleaning Tanks 1. Park the machine next to a floor drain. Drain hoses are at the front of the machine. 2. Turn the machine power off. Recovery Tank 1. Open the recovery tank lid. Pull the recovery drain hose from the mounting bracket. Open cap, then lower hose in direction of the drain. Do not stand in front of end of hose. Recovered solution will come out with force. 2. Flush the recovery tank out with clean water. Do not use water hotter than 140°F (60°C) to clean tank. Damage may occur. 3. Clean debris bin. 4. Clean off the float shut-off system and inspect for free movement of float. 5. Replace the drain hose cap and secure drain hose. 6. If machine is to be stored, leave the recovery tank lid propped open. 86372820 Chariot 3 iExtract 26 Duo 23