Download Matrix M100V Specifications

Transcript
Matrix Installation and Operation Instructions
1.0 SPECIFICATIONS
Table 1.1 General Specifications
Input
MBH
M100
25-150
M100V
25-150
Output
MBH
23139
23139
Steady State
Efficiency %
AFUE
%
Supply
Plenum
inches
Return
Plenum
inches
Airflow
Heating
CFM
Airflow
Cooling
CFM
Ventilation
CFM
Dimensions
H-W-D
Vent/Air
Size
95
92.7
20x16
18x18
300-1200
400-1600
-
53-28-38
3”
95
92.7
20x16
18x18
300-1200
400-1600
70-150
53-28-38
3”
1.1 High Altitude Operation
The Matrix is designed to operate to capacity
in installations at 2000 feet of elevation or
less. As elevations higher than 2000 feet
have less dense air, the unit is not capable of
providing its specified capacity. (See Chart).
In Canada:
De-rate by 5% for altitudes between 2000
and 4500 feet. For altitudes above 4500 feet
consult with local authorities.
In USA:
De-rate by 4% for every 1000 feet over 2000
feet.
Figure 1.1 Maximum Capacity vs. Altitude
160
150
Input (Mbh)
Model
140
130
120
110
0-2000
3000
4000
5000
6000
7000
8000
9000
10000
Elevation (ft)
CAUTION
AT ELEVATIONS GREATER THAN 2000 FEET, THE COMBUSTION OF THE MATRIX MUST BE CHECKED
WITH A CALIBRATED COMBUSTION TESTER TO ENSURE SAFE AND RELIABLE OPERATION. CONSULT
SECTION 5.20 FOR INSTRUCTIONS ON ADJUSTING THE INPUT TO PROVIDE PROPER OPERATION.
IT IS THE INSTALLERS RESPONSIBILITY TO CHECK THE COMBUSTION, AND
TO ADJUST THE COMBUSTION IN ACCORDANCE TO SECTION 5.20
3