Download Wolf WWD30 Installation guide
Transcript
INSTALLATION GUIDE Warming Drawer Contents Important Note Wolf Warming Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . 3 To ensure the safe and efficient use of Wolf equipment, please take note of the following types of highlighted information throughout this guide: Installation Considerations . . . . . . . . . . . . . . . . . . . . . . 4 Warming Drawer Installation . . . . . . . . . . . . . . . . . . . . 7 Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Features and specifications in this guide and on the website are subject to change at any time without notice. Check our website, wolfappliance.com, for the most up-to-date specifications. IMPORTANT NOTE highlights information that is especially important. CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed. WARNING states a hazard that may cause serious injury or death if precautions are not followed. Wolf Warming Drawer 3 wolfappliance.com Warming Drawer Installation IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. Read this entire installation guide prior to installation and save for the local inspector’s reference. The homeowner should keep this installation guide for future reference. Any questions or problems regarding installation of the warming drawer should be directed to your Wolf dealer or Wolf Appliance, Inc. at 800-332-9513, or visit our website at wolfappliance.com. IMPORTANT NOTE: This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate. Record the model and serial number before installing the warming drawer. Both numbers are listed on the product rating plate, located on the left front floor area of the inner cabinet. To access the rating plate, the drawer must be fully open. Refer to the illustration below. RATING PLATE Location of rating plate. Wolf Warming Drawer Model Number Serial Number WWD30 Installation Considerations 4 Before You Start • Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Wolf warranty. Refer to the warming drawer use & care guide for warranty details. • Warranty service must be performed by a Wolf authorized service center. Wolf is not responsible for service required to correct a faulty installation. TOOLS AND MATERIALS REQUIRED • Minimum 3/4" (19) thick lumber for the solid platform that supports the warming drawer—must be able to support 200 lbs (91 kg) • Wood screws and hardware to install the platform • 2" x 2" or 2" x 4" lumber for anti-tip block • Model WWD30 must be installed with a Wolf stainless steel or integrated drawer front. Make sure you have the accessory drawer front called for in your installation. Specific installation instructions are included with the drawer front. • Power saw • Make sure cabinetry meets the minimum dimension requirements for your specific installation. • Phillips screwdriver • Check with local utilities for electrical codes that apply in your area. Local codes vary. Installation, electrical connections and grounding must comply with applicable codes. In the absence of local codes, the drawer should be installed in accordance with National Electrical Code ANSI/NFPA 70-1990 or latest edition. • Wood cleats (optional) • This appliance must be properly grounded. Refer to electrical requirements on page 13. • Make sure you have the tools and materials necessary for proper installation. • Level • Drill and 1/16" bit, 1/2" bit also for integrated drawer front application • 2 wood screws (provided) Installation Considerations 5 wolfappliance.com Installation Considerations MODEL WWD30 COMBINATION INSTALLATIONS • Model WWD30 must be installed with a Wolf stainless steel or integrated drawer front. Specific installation instructions are included with the drawer front. • Model WWD30 may be installed in combination with a Wolf built-in oven and/or microwave. Additional clearance between warming drawer and oven openings may be required. To allow the warming drawer trim and the oven trim to meet, a 7/8" (22) platform may be used to separate the two openings. This will act as the support platform for the oven and the anti-tip device for the warming drawer. An anti-tip block may be installed at the rear of the cabinet in place of the platform. If the warming drawer is installed above an oven, a 7/8" (22) platform is required to allow for clearance of overlaps. • The warming drawer platform must be able to support 200 lbs (91 kg). • The warming drawer platform must be a minimum of 1" (25) above the toe kick to allow for the overlap of the warming drawer trim. • For undercounter installations, 231/2" (597) from the bottom of the warming drawer opening to the floor is typical. • Model WWD30 may be installed below a Wolf cooktop or sealed burner rangetop. Allow enough room for gas and electrical connections for the cooktop. • Model WWD30 may be installed next to or above another Wolf warming drawer. IMPORTANT NOTE: For combination installations, refer to installation instructions provided with the other Wolf products for additional specifications. Installation Considerations 6 WWD30 Drawer Front Options IMPORTANT NOTE: Model WWD30 must be installed with a Wolf stainless steel or integrated drawer front. OVERALL DIMENSIONS A When installing a Wolf warming drawer in combination with an L Series built-in oven, Wolf recommends using the L Series drawer front with tubular handle. For all other warming drawer installations, a 1-inch or 2-inch thick drawer front with handle is recommended. These front panels are designed on the E Series front panel platform and are available with a tubular, curved or pro handle. 10 3/8" 9" (264) 29 7/8" (759) OR 35 7/8" (911) 28 1/4" (718) (229) 3/4" (19) B 22 3/4" (578) 3/4" (19) The 2-inch thick drawer fronts with pro handle are designed to be installed below a sealed burner rangetop so the panel aligns properly with the front of the rangetop. 211/2" C (546) Drawer Front Panel and Handle Dimensions L SERIES PANEL 7/8" Tubular Handle A (22) 1-INCH THICK PANEL Tubular Handle Curved Handle (framed) Curved Handle (unframed) Pro Handle A 11/8" (29) 11/8" (29) 11/8" (29) 11/8" (29) 2-INCH THICK PANEL Pro Handle (30-inch wide) Pro Handle (36-inch wide) B C 3 1/2" (89) 25" (635) B C 3 1/2" (89) 25" (635) 2 3/4" (70) 24 1/4" (616) 2 3/4" (70) 24 1/4" (616) 3 1/2" (89) 25" (635) A B C 2 1/8" (54) 2 1/8" (54) 4 1/2" (114) 4 1/2" (114) 26" (660) 26" (660) INTEGRATED PANEL Custom Handle 1/4" A B C (6) NA NA Dimensions may vary ± 1/8" (3). IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are in millimeters unless otherwise specified. Warming Drawer Installation 7 wolfappliance.com WWD30 with L Series Drawer Front UNDERCOUNTER INSTALLATION 2" (51) x 2" (51) ANTI-TIP BLOCK 91/8" (232) OPENING HEIGHT DIMENSION WILL VARY* 10 3/8" 28 5/8" (727) OPENING WIDTH (264) E 7/8" (22) PLATFORM 24" min (610) CABINET DEPTH 36" (914) 23 1/2" (597) STANDARD FLOOR TO COUNTERTOP HEIGHT BOTTOM OF OPENING TO FLOOR (typical) SIDE VIEW 33" rec (838) 30" min (610) CABINET WIDTH FRONT VIEW *Dimension must accommodate height of anti-tip block and drawer face overlap. Dashed line represents profile of unit. IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply for the warming drawer be placed in an adjacent cabinet within reach of the conduit. INSTALLATION WITH 30" (762) L SERIES OVEN AND MICROWAVE 18 11/16" (475)* 19 7/8" (505)* OPENING HEIGHT TRIM HEIGHT 27 1/2" (699) MICROWAVE OPENING WIDTH 1 7/16" (37) PLATFORM* E 27 3/16" 271/2" (691) OPENING HEIGHT (699) TRIM HEIGHT 91/8" (232) OPENING HEIGHT 10 3/8" (264) 28 1/2" (724) L SERIES OVEN OPENING WIDTH 7/8" (22) PLATFORM E 28 5/8" (727) WARMING DRAWER OPENING WIDTH E 7/8" (22) PLATFORM 24" min (610) CABINET DEPTH 33" rec (838) 30" min (762) CABINET WIDTH SIDE VIEW FRONT VIEW *Dimensions are for convection microwave. For standard microwave, opening height is 18 1/4" (464), trim height is 17" (432) and platform is 1" (25). Dashed lines represent profile of unit. IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply for the warming drawer and for the oven be placed in an adjacent cabinet within reach of the conduit. Refer to L Series oven specifications for electrical location. Warming Drawer Installation 8 WWD30 with Integrated Drawer Front INSTALLATION WITH 36" (914) L SERIES OVEN AND MICROWAVE 18 11/16" (475)* 19 7/8" (505)* OPENING HEIGHT TRIM HEIGHT 33 3/8" (854) MICROWAVE OPENING WIDTH E 1 7/16" (37) PLATFORM* 241/16" 24 3/8" (611) OPENING HEIGHT (619) TRIM HEIGHT 341/2" (876) L SERIES OVEN OPENING WIDTH 7/8" (22) PLATFORM 91/8" (232) 10 3/8" OPENING HEIGHT (264) 28 5/8" (727) WARMING DRAWER OPENING WIDTH E E 7/8" (22) PLATFORM 24" min (610) CABINET DEPTH SIDE VIEW 39" rec (991) 36" min (914) CABINET WIDTH FRONT VIEW *Dimensions are for convection microwave. For standard microwave, opening height is 18 1/4" (464), trim height is 17" (432) and platform is 1" (25). Dashed lines represent profile of unit. IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply for the warming drawer and for the oven be placed in an adjacent cabinet within reach of the conduit. Refer to L Series oven specifications for electrical location. Warming Drawer Installation 9 wolfappliance.com WWD30 with 1-Inch Thick Drawer Front UNDERCOUNTER STANDARD INSTALLATION 2" (51) x 2" (51) ANTI-TIP BLOCK 91/8" (232) OPENING HEIGHT DIMENSION WILL VARY* 10 3/8" 28 5/8" (727) OPENING WIDTH (264) E 7/8" (22) PLATFORM 24" min (610) CABINET DEPTH 36" (914) 23 1/2" (597) STANDARD FLOOR TO COUNTERTOP HEIGHT BOTTOM OF OPENING TO FLOOR (typical) SIDE VIEW 33" rec (838) 30" min (610) CABINET WIDTH FRONT VIEW *Dimension must accommodate height of anti-tip block and drawer face overlap. Dashed line represents profile of unit. IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply for the warming drawer be placed in an adjacent cabinet within reach of the conduit. UNDERCOUNTER FLUSH INSET INSTALLATION TOP VIEW 24" min (610) FLUSH INSET DEPTH 1" (32) SIDE CLEATS 2" (51) x 2" (51) ANTI-TIP BLOCK 91/8" (232) OPENING HEIGHT DIMENSION WILL VARY* 7/8" (22) TOP AND SIDE CLEATS 10 7/8" (276) 28 5/8" (727) OPENING WIDTH FLUSH INSET HEIGHT 7/8" (22) PLATFORM 24" min (610) CABINET DEPTH SIDE VIEW 36" (914) 23 1/2" (597) STANDARD FLOOR TO COUNTERTOP HEIGHT BOTTOM OF OPENING TO FLOOR (typical) E E 30 3/8" (772) FLUSH INSET WIDTH 36" rec (914) 33" min (838) CABINET WIDTH FRONT VIEW *Dimension must accommodate height of anti-tip block and drawer face overlap. Dashed line represents profile of unit. IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply for the warming drawer be placed in an adjacent cabinet within reach of the conduit. Warming Drawer Installation 10 WWD30 with 1-Inch Thick Drawer Front STANDARD INSTALLATION WITH E SERIES OVEN AND MICROWAVE 18 11/16" (475)* 19 7/8" (505)* OPENING HEIGHT TRIM HEIGHT 27 1/2" (699) MICROWAVE OPENING WIDTH 1 7/16" (37) PLATFORM* E 27 3/16" 27 7/8" (691) OPENING HEIGHT (708) TRIM HEIGHT 91/8" (232) OPENING HEIGHT 10 3/8" (264) 28 1/2" (724) E SERIES OVEN OPENING WIDTH 7/8" (22) PLATFORM E 28 5/8" (727) WARMING DRAWER OPENING WIDTH E 7/8" (22) PLATFORM 24" min (610) CABINET DEPTH 33" rec (838) 30" min (762) CABINET WIDTH SIDE VIEW FRONT VIEW *Dimensions are for convection microwave. For standard microwave, opening height is 18 1/4" (464), trim height is 17" (432) and platform is 1" (25). Dashed lines represent profile of unit. IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply for the warming drawer and for the oven be placed in an adjacent cabinet within reach of the conduit. Refer to E Series oven specifications for electrical location. Warming Drawer Installation 11 wolfappliance.com WWD30 with 1-Inch Thick Drawer Front FLUSH INSET INSTALLATION WITH E SERIES OVEN AND MICROWAVE TOP VIEW 25" min (635) FLUSH INSET DEPTH 1" (32) SIDE CLEATS 30 3/8" min (772) FLUSH INSET WIDTH 9/16" (14) TOP CLEAT 18 11/16" (475)* 19 7/8" (505)* OPENING HEIGHT TRIM HEIGHT 27 1/2" (699) MICROWAVE OPENING WIDTH 1 7/16" (37) PLATFORM* E 27 3/16" 27 7/8" (691) OPENING HEIGHT (708) TRIM HEIGHT 91/8" (232) OPENING HEIGHT 10 3/8" (264) 58 3/4" (1492)* FLUSH INSET HEIGHT 28 1/2" (724) E SERIES OVEN OPENING WIDTH 7/8" (22) PLATFORM E 28 5/8" (727) WARMING DRAWER OPENING WIDTH E 7/8" (22) SIDE CLEATS 7/8" (22) PLATFORM 25" min (635) CABINET DEPTH 36" rec (914) 33" min (838) CABINET WIDTH SIDE VIEW FRONT VIEW *Dimensions are for convection microwave. For standard microwave, opening height is 18 1/4" (464), trim height is 17" (432), flush inset height is 56 5/8" (1438) and platform is 1" (25). Dashed lines represent profile of unit. Warming Drawer Installation 12 WWD30 with 2-Inch Thick Drawer Front INSTALLATION WITH SEALED BURNER RANGETOP COOKING SURFACE 3/4" (19) 7 1/2" 8 1/2"(216) PLATFORM (191) 91/8" (232) OPENING HEIGHT 24" min (610) CABINET DEPTH SIDE VIEW 10 3/8" (264) 36" (914) STANDARD FLOOR TO COUNTERTOP HEIGHT 36" (914) RANGETOP OPENING WIDTH 3/4" (19) PLATFORM 28 5/8" (727) WARMING DRAWER OPENING WIDTH E 7/8" (22) PLATFORM 36" (914) CABINET WIDTH FRONT VIEW IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply for the warming drawer be placed in an adjacent cabinet within reach of the conduit. Dashed line represents profile of unit. Warming Drawer Installation 13 wolfappliance.com Integrated Drawer Front INSTALL RECESSED CLEATS AND PLATFORM Integrated Drawer Front For an overlay or flush inset application, you will need to install a recessed platform and cleats into the opening. Refer to the chart for specifications. Proper recess of the platform and cleats is critical to the function and esthetics of the warming drawer installation. DRAWER FRONT The depth of the platform may increase with the cabinet depth. Be sure to rigidly mount the platform so that it can support a minimum of 200 lbs (91 kg). Refer to the illustrations below. Mounting holes will need to be drilled in the back of the drawer front panel. Holes should be drilled on site to ensure proper fit and gaps are achieved. A drilling template is provide with the integrated drawer front. IMPORTANT NOTE: Be sure to finish the inside lip of the opening and the front face of the platform and cleats. These areas may be visible when the drawer is open. IMPORTANT NOTE: Be aware of the location of the mounting holes on the warming drawer frame to make sure screws used to attach the cleats do not interfere with screw holes for mounting the warming drawer. Overlay Panel (min) Flush Inset Panel W H 29 3/8" (746) 29 3/8" (746) 10 1/4" (260) 10" (254) CLEATS AND PLATFORM Top Cleat Side Cleats Platform W 29 7/8" (759) 1/2" (13) 29 7/8" (759) D (19) 3/4" (19) 3/4" H D (16) 9 1/8" (232) 3/4" (19) 2" (51) 2" (51) 23 3/4" (603) 5/8" RECESS CLEATS AND PLATFORM Overlay Flush Inset 3/16" (5) thickness of custom panel + 3/16" (5) Electrical Requirements The electrical supply should be located as shown in the illustration for your specific installation on previous pages. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance is required. If two warming drawers are installed side by side, they can operate from the same electrical outlet. A 30 amp circuit breaker is required for this installation. IMPORTANT NOTE: When installed outdoors, a ground fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock. TOP CLEAT TOP CLEAT Electrical Requirements Power Supply Circuit Breaker PLATFORM PLATFORM SIDE CLEAT SIDE CLEAT CABINETRY OPENING CLEATS AND PLATFORM RECESSED 3/16" (5) PLUS THICKNESS CABINETRY OF DECORATIVE PANEL OPENING CLEATS AND PLATFORM RECESSED 3/16" (5) Overlay application. Flush inset application. Receptacle 120 V AC, 50/60 Hz 15 or 20 amp 3-prong grounding-type Warming Drawer Installation 14 Anti-Tip Block Install the Warming Drawer INSTALL ANTI-TIP BLOCKING Unpack the warming drawer on a flat surface. Remove all packaging materials from inside the warming drawer. Do not discard the package containing the two wood screws needed for installation. Install a 2" (51) x 2" (51) or 2" (51) x 4" (102) anti-tip block against the rear cabinet wall. When the warming drawer is installed below a built-in oven, you may use a 7/8" (22) thick platform to allow the warming drawer trim and the oven trim to meet. The platform will act as an anti-tip device for the warming drawer. An anti-tip block or platform must be installed to prevent the warming drawer from tipping forward while opened when loaded. Failure to do so could result in personal injury and damage to the cabinet. Turn power off to the electrical outlet. Slide the left corner of the warming drawer into the opening. If the electrical outlet is installed inside the opening, plug the power cord into the outlet. The excess cord should be coiled behind or beside the unit. If the outlet is located in an adjacent cabinet, thread the power cord through the hole in the cabinet wall. Push the drawer back into the opening until the trim meets the cabinet front. Make sure the power cord does not get trapped under the warming drawer. IMPORTANT NOTE: Do not lift up on the handle to push the drawer into place. Open the warming drawer to its full extension. Drill pilot holes in each side hole, located toward the front on each side of the warming drawer. Install the wood screws provided with the unit. Refer to the illustration below. Turn power back on to the electrical outlet. LOCATION OF SIDE HOLE Location of side hole. Service Information 15 wolfappliance.com Troubleshooting Service Information IMPORTANT NOTE: If the warming drawer does not operate properly, follow these troubleshooting steps: If service is necessary, maintain the quality built into your warming drawer by calling a Wolf authorized service center. • Verify that power is being supplied to the warming drawer. • Check electrical connections to ensure that the installation has been completed correctly. • Refer to the troubleshooting guide in the Wolf warming drawer use & care guide. • If the warming drawer still does not work, contact a Wolf authorized service center. Do not attempt to repair the warming drawer yourself. Wolf is not responsible for service required to correct a faulty installation. To obtain the name and number of a Wolf authorized service center, check the contact & support section of our website, wolfappliance.com or call Wolf customer service at 800-332-9513. When calling for service, you will need the model and serial number of the warming drawer. Both numbers are listed on the product rating plate, located on the left front floor area of the inner cabinet. To access the rating plate, the drawer must be fully open. Refer to the illustration on page 3 for location of the rating plate. The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. ©Wolf Appliance, Inc. all rights reserved. WOLF APPLIANCE, INC. P. O. BOX 44848 MADISON, WI 53744 812542 3/ 2009 WOLFAPPLIANCE.COM 800.332.9513