Download Wolf WWD30 Installation guide

Transcript
INSTALLATION GUIDE
Warming Drawer
Contents
Important Note
Wolf Warming Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . 3
To ensure the safe and efficient use of Wolf equipment,
please take note of the following types of highlighted
information throughout this guide:
Installation Considerations . . . . . . . . . . . . . . . . . . . . . . 4
Warming Drawer Installation . . . . . . . . . . . . . . . . . . . . 7
Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Features and specifications in this guide and on the website
are subject to change at any time without notice. Check our
website, wolfappliance.com, for the most up-to-date
specifications.
IMPORTANT NOTE highlights information that is
especially important.
CAUTION signals a situation where minor injury or
product damage may occur if instructions are not
followed.
WARNING states a hazard that may cause serious injury
or death if precautions are not followed.
Wolf Warming Drawer
3
wolfappliance.com
Warming Drawer Installation
IMPORTANT NOTE: This installation must be completed
by a qualified installer or Wolf authorized service center
technician.
Read this entire installation guide prior to installation and
save for the local inspector’s reference. The homeowner
should keep this installation guide for future reference.
Any questions or problems regarding installation of the
warming drawer should be directed to your Wolf dealer or
Wolf Appliance, Inc. at 800-332-9513, or visit our website
at wolfappliance.com.
IMPORTANT NOTE: This appliance must be installed in
accordance with National Electrical Codes, as well as all
state, municipal and local codes. The correct voltage,
frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is
protected by a properly sized circuit breaker or time delay
fuse. The proper voltage, frequency, and amperage ratings
are listed on the product rating plate.
Record the model and serial number before installing the
warming drawer. Both numbers are listed on the product
rating plate, located on the left front floor area of the inner
cabinet. To access the rating plate, the drawer must be
fully open. Refer to the illustration below.
RATING
PLATE
Location of rating plate.
Wolf Warming Drawer
Model Number
Serial Number
WWD30
Installation Considerations
4
Before You Start
• Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Wolf warranty. Refer to the warming
drawer use & care guide for warranty details.
• Warranty service must be performed by a Wolf authorized service center. Wolf is not responsible for service
required to correct a faulty installation.
TOOLS AND MATERIALS REQUIRED
• Minimum 3/4" (19) thick lumber for the solid platform
that supports the warming drawer—must be able to
support 200 lbs (91 kg)
• Wood screws and hardware to install the platform
• 2" x 2" or 2" x 4" lumber for anti-tip block
• Model WWD30 must be installed with a Wolf stainless
steel or integrated drawer front. Make sure you have
the accessory drawer front called for in your installation. Specific installation instructions are included with
the drawer front.
• Power saw
• Make sure cabinetry meets the minimum dimension
requirements for your specific installation.
• Phillips screwdriver
• Check with local utilities for electrical codes that apply
in your area. Local codes vary. Installation, electrical
connections and grounding must comply with applicable codes. In the absence of local codes, the drawer
should be installed in accordance with National Electrical Code ANSI/NFPA 70-1990 or latest edition.
• Wood cleats (optional)
• This appliance must be properly grounded. Refer to
electrical requirements on page 13.
• Make sure you have the tools and materials necessary
for proper installation.
• Level
• Drill and 1/16" bit, 1/2" bit also for integrated drawer
front application
• 2 wood screws (provided)
Installation Considerations
5
wolfappliance.com
Installation Considerations
MODEL WWD30
COMBINATION INSTALLATIONS
• Model WWD30 must be installed with a Wolf stainless
steel or integrated drawer front. Specific installation
instructions are included with the drawer front.
• Model WWD30 may be installed in combination with a
Wolf built-in oven and/or microwave. Additional clearance between warming drawer and oven openings may
be required. To allow the warming drawer trim and the
oven trim to meet, a 7/8" (22) platform may be used to
separate the two openings. This will act as the support
platform for the oven and the anti-tip device for the
warming drawer. An anti-tip block may be installed at
the rear of the cabinet in place of the platform. If the
warming drawer is installed above an oven, a 7/8" (22)
platform is required to allow for clearance of overlaps.
• The warming drawer platform must be able to support
200 lbs (91 kg).
• The warming drawer platform must be a minimum of
1" (25) above the toe kick to allow for the overlap of the
warming drawer trim.
• For undercounter installations, 231/2" (597) from the
bottom of the warming drawer opening to the floor is
typical.
• Model WWD30 may be installed below a Wolf cooktop
or sealed burner rangetop. Allow enough room for gas
and electrical connections for the cooktop.
• Model WWD30 may be installed next to or above
another Wolf warming drawer.
IMPORTANT NOTE: For combination installations, refer to
installation instructions provided with the other Wolf
products for additional specifications.
Installation Considerations
6
WWD30 Drawer Front Options
IMPORTANT NOTE: Model WWD30 must be installed with
a Wolf stainless steel or integrated drawer front.
OVERALL DIMENSIONS
A
When installing a Wolf warming drawer in combination
with an L Series built-in oven, Wolf recommends using the
L Series drawer front with tubular handle. For all other
warming drawer installations, a 1-inch or 2-inch thick
drawer front with handle is recommended. These front
panels are designed on the E Series front panel platform
and are available with a tubular, curved or pro handle.
10 3/8"
9"
(264)
29 7/8" (759)
OR 35 7/8" (911)
28 1/4" (718)
(229)
3/4" (19)
B
22 3/4" (578)
3/4"
(19)
The 2-inch thick drawer fronts with pro handle are
designed to be installed below a sealed burner rangetop
so the panel aligns properly with the front of the rangetop.
211/2" C
(546)
Drawer Front Panel and Handle Dimensions
L SERIES PANEL
7/8"
Tubular Handle
A
(22)
1-INCH THICK PANEL
Tubular Handle
Curved Handle (framed)
Curved Handle (unframed)
Pro Handle
A
11/8" (29)
11/8" (29)
11/8" (29)
11/8" (29)
2-INCH THICK PANEL
Pro Handle (30-inch wide)
Pro Handle (36-inch wide)
B
C
3 1/2" (89)
25" (635)
B
C
3 1/2" (89)
25" (635)
2 3/4" (70) 24 1/4" (616)
2 3/4" (70) 24 1/4" (616)
3 1/2" (89)
25" (635)
A
B
C
2 1/8" (54)
2 1/8" (54)
4 1/2" (114)
4 1/2" (114)
26" (660)
26" (660)
INTEGRATED PANEL
Custom Handle
1/4"
A
B
C
(6)
NA
NA
Dimensions may vary ± 1/8" (3).
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are in millimeters unless otherwise specified.
Warming Drawer Installation
7
wolfappliance.com
WWD30 with L Series Drawer Front
UNDERCOUNTER INSTALLATION
2" (51) x 2" (51)
ANTI-TIP BLOCK
91/8" (232)
OPENING HEIGHT
DIMENSION
WILL VARY*
10 3/8"
28 5/8" (727)
OPENING WIDTH
(264)
E
7/8" (22) PLATFORM
24" min (610)
CABINET DEPTH
36" (914)
23 1/2" (597)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
BOTTOM
OF OPENING
TO FLOOR
(typical)
SIDE VIEW
33" rec (838)
30" min (610)
CABINET WIDTH
FRONT VIEW
*Dimension must accommodate height of anti-tip block and drawer face overlap. Dashed line represents profile of unit.
IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply for the warming drawer
be placed in an adjacent cabinet within reach of the conduit.
INSTALLATION WITH 30" (762) L SERIES OVEN AND MICROWAVE
18 11/16" (475)*
19 7/8" (505)*
OPENING
HEIGHT
TRIM
HEIGHT
27 1/2" (699)
MICROWAVE
OPENING WIDTH
1 7/16" (37) PLATFORM* E
27 3/16"
271/2"
(691)
OPENING
HEIGHT
(699)
TRIM
HEIGHT
91/8" (232)
OPENING HEIGHT
10 3/8"
(264)
28 1/2" (724)
L SERIES OVEN
OPENING WIDTH
7/8" (22) PLATFORM
E
28 5/8" (727)
WARMING DRAWER
OPENING WIDTH
E
7/8" (22) PLATFORM
24" min (610)
CABINET DEPTH
33" rec (838)
30" min (762)
CABINET WIDTH
SIDE VIEW
FRONT VIEW
*Dimensions are for convection microwave. For standard microwave, opening height is 18 1/4" (464), trim height is 17" (432) and platform is 1" (25).
Dashed lines represent profile of unit. IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the
electrical supply for the warming drawer and for the oven be placed in an adjacent cabinet within reach of the conduit. Refer to L Series oven
specifications for electrical location.
Warming Drawer Installation
8
WWD30 with Integrated Drawer Front
INSTALLATION WITH 36" (914) L SERIES OVEN AND MICROWAVE
18 11/16" (475)*
19 7/8" (505)*
OPENING
HEIGHT
TRIM
HEIGHT
33 3/8" (854)
MICROWAVE
OPENING WIDTH
E
1 7/16" (37) PLATFORM*
241/16"
24 3/8"
(611)
OPENING
HEIGHT
(619)
TRIM
HEIGHT
341/2" (876)
L SERIES OVEN
OPENING WIDTH
7/8" (22) PLATFORM
91/8" (232)
10 3/8"
OPENING HEIGHT
(264)
28 5/8" (727)
WARMING DRAWER
OPENING WIDTH
E
E
7/8" (22) PLATFORM
24" min (610)
CABINET DEPTH
SIDE VIEW
39" rec (991)
36" min (914)
CABINET WIDTH
FRONT VIEW
*Dimensions are for convection microwave. For standard microwave, opening height is 18 1/4" (464), trim height is 17" (432) and platform is 1" (25).
Dashed lines represent profile of unit. IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the
electrical supply for the warming drawer and for the oven be placed in an adjacent cabinet within reach of the conduit. Refer to L Series oven
specifications for electrical location.
Warming Drawer Installation
9
wolfappliance.com
WWD30 with 1-Inch Thick Drawer Front
UNDERCOUNTER STANDARD INSTALLATION
2" (51) x 2" (51)
ANTI-TIP BLOCK
91/8" (232)
OPENING HEIGHT
DIMENSION
WILL VARY*
10 3/8"
28 5/8" (727)
OPENING WIDTH
(264)
E
7/8" (22) PLATFORM
24" min (610)
CABINET DEPTH
36" (914)
23 1/2" (597)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
BOTTOM
OF OPENING
TO FLOOR
(typical)
SIDE VIEW
33" rec (838)
30" min (610)
CABINET WIDTH
FRONT VIEW
*Dimension must accommodate height of anti-tip block and drawer face overlap. Dashed line represents profile of unit.
IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply for the warming drawer
be placed in an adjacent cabinet within reach of the conduit.
UNDERCOUNTER FLUSH INSET INSTALLATION
TOP VIEW
24" min (610)
FLUSH INSET
DEPTH
1" (32)
SIDE CLEATS
2" (51) x 2" (51)
ANTI-TIP BLOCK
91/8" (232)
OPENING HEIGHT
DIMENSION
WILL VARY*
7/8" (22) TOP AND SIDE CLEATS
10 7/8" (276)
28 5/8" (727)
OPENING WIDTH
FLUSH INSET
HEIGHT
7/8" (22) PLATFORM
24" min (610)
CABINET DEPTH
SIDE VIEW
36" (914)
23 1/2" (597)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
BOTTOM
OF OPENING
TO FLOOR
(typical)
E
E
30 3/8" (772)
FLUSH INSET WIDTH
36" rec (914)
33" min (838)
CABINET WIDTH
FRONT VIEW
*Dimension must accommodate height of anti-tip block and drawer face overlap. Dashed line represents profile of unit.
IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply for the warming drawer
be placed in an adjacent cabinet within reach of the conduit.
Warming Drawer Installation
10
WWD30 with 1-Inch Thick Drawer Front
STANDARD INSTALLATION WITH E SERIES OVEN AND MICROWAVE
18 11/16" (475)*
19 7/8" (505)*
OPENING
HEIGHT
TRIM
HEIGHT
27 1/2" (699)
MICROWAVE
OPENING WIDTH
1 7/16" (37) PLATFORM* E
27 3/16"
27 7/8"
(691)
OPENING
HEIGHT
(708)
TRIM
HEIGHT
91/8" (232)
OPENING HEIGHT
10 3/8" (264)
28 1/2" (724)
E SERIES OVEN
OPENING WIDTH
7/8" (22) PLATFORM
E
28 5/8" (727)
WARMING DRAWER
OPENING WIDTH
E
7/8" (22) PLATFORM
24" min (610)
CABINET DEPTH
33" rec (838)
30" min (762)
CABINET WIDTH
SIDE VIEW
FRONT VIEW
*Dimensions are for convection microwave. For standard microwave, opening height is 18 1/4" (464), trim height is 17" (432) and platform is 1" (25).
Dashed lines represent profile of unit. IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the
electrical supply for the warming drawer and for the oven be placed in an adjacent cabinet within reach of the conduit. Refer to E Series oven
specifications for electrical location.
Warming Drawer Installation
11
wolfappliance.com
WWD30 with 1-Inch Thick Drawer Front
FLUSH INSET INSTALLATION WITH E SERIES OVEN AND MICROWAVE
TOP VIEW
25" min (635)
FLUSH INSET
DEPTH
1" (32)
SIDE CLEATS
30 3/8" min (772)
FLUSH INSET WIDTH
9/16" (14) TOP CLEAT
18 11/16" (475)*
19 7/8" (505)*
OPENING
HEIGHT
TRIM
HEIGHT
27 1/2" (699)
MICROWAVE
OPENING WIDTH
1 7/16" (37) PLATFORM* E
27 3/16"
27 7/8"
(691)
OPENING
HEIGHT
(708)
TRIM
HEIGHT
91/8" (232)
OPENING HEIGHT
10 3/8" (264)
58 3/4"
(1492)*
FLUSH
INSET
HEIGHT
28 1/2" (724)
E SERIES OVEN
OPENING WIDTH
7/8" (22) PLATFORM
E
28 5/8" (727)
WARMING DRAWER
OPENING WIDTH
E
7/8" (22)
SIDE CLEATS
7/8" (22) PLATFORM
25" min (635)
CABINET DEPTH
36" rec (914)
33" min (838)
CABINET WIDTH
SIDE VIEW
FRONT VIEW
*Dimensions are for convection microwave. For standard microwave, opening height is 18 1/4" (464), trim height is 17" (432), flush inset height is
56 5/8" (1438) and platform is 1" (25). Dashed lines represent profile of unit.
Warming Drawer Installation
12
WWD30 with 2-Inch Thick Drawer Front
INSTALLATION WITH SEALED BURNER RANGETOP
COOKING
SURFACE
3/4" (19)
7 1/2"
8 1/2"(216)
PLATFORM (191)
91/8" (232)
OPENING HEIGHT
24" min (610)
CABINET DEPTH
SIDE VIEW
10 3/8"
(264)
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
36" (914)
RANGETOP OPENING WIDTH
3/4" (19) PLATFORM
28 5/8" (727)
WARMING DRAWER
OPENING WIDTH
E
7/8" (22) PLATFORM
36" (914)
CABINET WIDTH
FRONT VIEW
IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply for the warming drawer
be placed in an adjacent cabinet within reach of the conduit. Dashed line represents profile of unit.
Warming Drawer Installation
13
wolfappliance.com
Integrated Drawer Front
INSTALL RECESSED CLEATS AND PLATFORM
Integrated Drawer Front
For an overlay or flush inset application, you will need to
install a recessed platform and cleats into the opening.
Refer to the chart for specifications. Proper recess of the
platform and cleats is critical to the function and esthetics
of the warming drawer installation.
DRAWER FRONT
The depth of the platform may increase with the cabinet
depth. Be sure to rigidly mount the platform so that it
can support a minimum of 200 lbs (91 kg). Refer to the
illustrations below.
Mounting holes will need to be drilled in the back of the
drawer front panel. Holes should be drilled on site to
ensure proper fit and gaps are achieved. A drilling
template is provide with the integrated drawer front.
IMPORTANT NOTE: Be sure to finish the inside lip of the
opening and the front face of the platform and cleats.
These areas may be visible when the drawer is open.
IMPORTANT NOTE: Be aware of the location of the
mounting holes on the warming drawer frame to make
sure screws used to attach the cleats do not interfere with
screw holes for mounting the warming drawer.
Overlay Panel (min)
Flush Inset Panel
W
H
29 3/8" (746)
29 3/8" (746)
10 1/4" (260)
10" (254)
CLEATS AND PLATFORM
Top Cleat
Side Cleats
Platform
W
29 7/8" (759)
1/2" (13)
29 7/8" (759)
D
(19)
3/4" (19)
3/4"
H
D
(16)
9 1/8" (232)
3/4" (19)
2" (51)
2" (51)
23 3/4" (603)
5/8"
RECESS CLEATS AND PLATFORM
Overlay
Flush Inset
3/16"
(5)
thickness of custom panel + 3/16" (5)
Electrical Requirements
The electrical supply should be located as shown in the
illustration for your specific installation on previous pages.
Follow the National Electrical Code and local codes and
ordinances when installing the receptacle. A separate
circuit, servicing only this appliance is required.
If two warming drawers are installed side by side, they can
operate from the same electrical outlet. A 30 amp circuit
breaker is required for this installation.
IMPORTANT NOTE: When installed outdoors, a ground
fault circuit interrupter (GFCI) is required to reduce the risk
of electrical shock.
TOP CLEAT
TOP CLEAT
Electrical Requirements
Power Supply
Circuit Breaker
PLATFORM
PLATFORM
SIDE CLEAT
SIDE CLEAT
CABINETRY
OPENING
CLEATS AND PLATFORM
RECESSED 3/16" (5)
PLUS THICKNESS
CABINETRY
OF DECORATIVE PANEL OPENING
CLEATS AND PLATFORM
RECESSED 3/16" (5)
Overlay application.
Flush inset application.
Receptacle
120 V AC, 50/60 Hz
15 or 20 amp
3-prong grounding-type
Warming Drawer Installation
14
Anti-Tip Block
Install the Warming Drawer
INSTALL ANTI-TIP BLOCKING
Unpack the warming drawer on a flat surface. Remove all
packaging materials from inside the warming drawer. Do
not discard the package containing the two wood screws
needed for installation.
Install a 2" (51) x 2" (51) or 2" (51) x 4" (102) anti-tip block
against the rear cabinet wall. When the warming drawer is
installed below a built-in oven, you may use a 7/8" (22)
thick platform to allow the warming drawer trim and the
oven trim to meet. The platform will act as an anti-tip
device for the warming drawer.
An anti-tip block or platform must be installed to
prevent the warming drawer from tipping forward while
opened when loaded. Failure to do so could result in
personal injury and damage to the cabinet.
Turn power off to the electrical outlet.
Slide the left corner of the warming drawer into the
opening. If the electrical outlet is installed inside the
opening, plug the power cord into the outlet. The excess
cord should be coiled behind or beside the unit. If the
outlet is located in an adjacent cabinet, thread the power
cord through the hole in the cabinet wall. Push the drawer
back into the opening until the trim meets the cabinet
front. Make sure the power cord does not get trapped
under the warming drawer.
IMPORTANT NOTE: Do not lift up on the handle to push
the drawer into place.
Open the warming drawer to its full extension. Drill pilot
holes in each side hole, located toward the front on each
side of the warming drawer. Install the wood screws
provided with the unit. Refer to the illustration below.
Turn power back on to the electrical outlet.
LOCATION OF
SIDE HOLE
Location of side hole.
Service Information
15
wolfappliance.com
Troubleshooting
Service Information
IMPORTANT NOTE: If the warming drawer does not
operate properly, follow these troubleshooting steps:
If service is necessary, maintain the quality built into your
warming drawer by calling a Wolf authorized service
center.
• Verify that power is being supplied to the warming
drawer.
• Check electrical connections to ensure that the installation has been completed correctly.
• Refer to the troubleshooting guide in the Wolf warming
drawer use & care guide.
• If the warming drawer still does not work, contact a
Wolf authorized service center. Do not attempt to repair
the warming drawer yourself. Wolf is not responsible
for service required to correct a faulty installation.
To obtain the name and number of a Wolf authorized
service center, check the contact & support section of our
website, wolfappliance.com or call Wolf customer service
at 800-332-9513.
When calling for service, you will need the model and
serial number of the warming drawer. Both numbers are
listed on the product rating plate, located on the left front
floor area of the inner cabinet. To access the rating plate,
the drawer must be fully open. Refer to the illustration on
page 3 for location of the rating plate.
The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained
herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. ©Wolf Appliance, Inc. all rights reserved.
WOLF APPLIANCE, INC.
P. O. BOX 44848 MADISON, WI 53744
812542
3/ 2009
WOLFAPPLIANCE.COM
800.332.9513