Download Black Box IC108A Specifications

Transcript
From
To
Belden
#
Gauge
#
Prs
Shielded
Max
Length
apC/L
9855
22
2
Yes
50 ft.
RS-232 Comm (5wire)
Host
apC/L
8303
22
3
Yes
50 ft.
RS-485 Comm
Host
apC/L
9842*
24
2
Yes
4000 ft.
Comm
apC/L
RM-4
9841*
24
1
Yes
4000 ft.
Power
apC/L
RM-4
8442/8461
22/18
1
No
See Appen
B
Control
apC/L/
ARM
Strike
8641
18
1
No
See Appen
B
Supervised
Input
Module
Contact/
8442/8461
22/18
1
No
2000 ft.
Request-to-exit
RM-4
Switch
8442/8461
22/18
1
No
2000 ft.
Door contact
RM-4
Contact
8442/8461
22/18
1
No
25 ft.
Relay
RM-4
ARM
9462
22
1
Yes
25 ft.
Reader
RM-4
Wiegand/
Prox Read
Head
9536
22
3
Yes
500 ft.
* For plenum or underground applications, use Manhattan M63995 for 2 pair only, (host wiring) 150 ohm, 8.8pf/ft
or Belden 89182 for 1 pair (reader wiring) 22AWG, 100 ohm, 12.95pf/ft.
2-3
C•CURE apC/L Technical Manual
Data
Switch
Equipment Wiring Requirements
Host
Table 2.2 Equipment Wiring Requirements
RS-232 Comm
Input
apcl.bk Page 3 Monday, May 15, 2000 3:21 PM
Signal