Download Miller Electric SCM-5A Specifications
Transcript
Miller September FORM: OM-126853A 1989 Effective With Serial No. JJ401061.. MODEL: ARC PAKIM 350 Manufactured For OWNERS Chicago Bridge & Iron MANUAL IMPORTANT: Read and understand the entire contents of this manual, with special emphasis on the safety material throughout the manual, before installing, operating, or maintaIning this equipment. This unit and these instructions are for use only by persons trained and experienced In the safe operation of welding equipment. Do not allow untrained persons to install, operate, or maintain this unit. Contact your distributor if you do not fully MILLER ELECTRIC MfcI. Co. - AMrnGfG(O~OLtd.CO~Y P0 Box 1079 .Appleton, WI 54912 USA Tel. 414-734-9821 understand these instructions. PRINT~D IN U.S.A I -J LIMITED WARRANTY EFFEC1IVE: This warranty supersedes all previous LIMITED WARRANTY MARCH 15, 1989 MILLER warranties and is exclusive with no.other guarantees Subject to the terms and conditions hereof, Miller Electric Mfg. Co., Appleton, Wisconsin warrants to its Distributor/Dealer that all new and unused Equipment fur nishedby Miller is free from defect in workmanship and material as of the time and place of delivery by Miller. No warranty is made by Miller with respect to engines, trade accessories or other items manufactured by others. Such engines, trade ac cessories and other items are sold subject to the warranties of their respective manufacturers, if any. All engines are war ranted by their manufacturer for one year from date of original purchase, except Tecumseh and Onan engines which have a two year warranty. Except as specified below, Millers warranty does not apply to components having normal useful life of less than one (1) year, such as spot welder tips, relay and contactor points, MILLER-, 5MA11C parts that come in contact with the welding wire includ nozzles and nozzle insulators where failure does not result from defect in workmanship or material. ing Miller shall be required to honor warranty claims on warranted Equipment in the event of failure resulting from a defect within the following periods from the date of delivery of Equipment to the original user: 1. Arc welders, power sources, robots, and 1 year 2. components Load banks 3. Original 4. 5. 6. 7. All welding guns, feeder/guns and torches 90 days All other Millermatic Feeders 1 year Replacement or repair parts, exclusive of labor 60 days Batteries 6 months (labor main power rectifiers 1 year only) provided that Miller is notified in the date of such failure. As a matter of general submitted by the original writing within thirty (30) days of MiHer may honor daims within the foregoing periods. policy only, user 1 year 3 years or warranties expressed or implied. In the case of Millers breach of warranty or any other duty with to the quality of any goods, the excluswe remedies therefore shall be, at Millers option (1) repair or (2) replacement or, where authorized in writing by Miller in appropriate cases, (3) the reasonable cost of repair or replacement at an authorized Miller service station or(4) payment of or credit for the purchase price (less reasonable depreaation based upon actual use) upon return of the goods at Customers risk and expense. MILLERsoption of repairorreplacenientwill be F.O.B.. Factory at Appleton, Wisconsin, or FOB. ata MILLER authorized serv ice facility, therefore, no compensation for transportation costs of any kind will be allowed. Upon receipt of notice of apparent defect or failure, Miller shall instruct the claimant on the war ranty claim procedures to be followed. respect ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY IMPLIED WARRANTV GUARANTY OR REPRE. SENTAT1ON AS TO PERFORMANCE, AND ANY REMEDY FOR BREACH OF CONTRACT WHICH, BUT FOR THIS PRO VISION, MIGHT ARISE BY IMPLICATION, OPERATION OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING, IN CLUDING ANY IMPUED WARRANTY OF MERCHAN TABILITY OR OF FITNESS FOR PARTICULAR PURPOSE, WiTH RESPECT TO ANY AND ALL EQUIPMENT FUR NISHED BY MILLER IS EXCLUDED AND DISCLAIMED BY MILLER EXCEPT AS EXPRESSLY PROVIDED BY MILLER IN WRITING, MILLER PRODUCTS ARE INTENDED FOR ULTI MATE PURCHASE BY COMMERCIAL/INDUSTRIAL USERS AND FOR OPERATION BY PERSONS TRAINED AND EXPE RIENCED IN THE USE AND MAINTENANCE OF WELDING EQUIPMENT AND NOT FOR CONSUMERS OR CON SUMER USE. MILLERS WARRANTIES DO NOT EXTEND TO, AND NO RESELLER IS AUTHORIZED TO EXTEND MILLERS WARRANTIES TO. ANY CONSUMER. I OM-126853A9/89 RECEiVING-HANDLING Before unpacking equipment, check carton for any damage that may have occurred during shipment. File any claims for loss or damage with the delivering carrier. Assistance for filing or settling claims may be obtained from the distributor and/or the eq~iipment manufactur- Use the following spaces to record the Model Design ation and Serial or Style Number of your unit. The infcr mation is located on the data card or the nameplate. Model _______________________________ ers Transportation Department. Senal requesting information about this equipment, al ways provide the Model Description and Serial or Style or Style No. ____________________ When Dateof Purchase _____________________ Number. TABLE OF CONTENTS Section No. SECTION 1 Page SAFETY RULES FOR OPERATION OF ARC WELDING POWER SOURCE 1-1. Introduction 1-2. General Precautions 1 1-3. Arc 4 1-4. Standards Boo k~et Index 1 Welding SECTION 2SAFETY 5 PRECAUTIONS AND SIGNAL WORDS 2-1. General Information And 2-2. Safety Alert Symbol And Safety Signal Words 6 6 SECTION 3SPECIFICATIONS 3-1. 3-2. 3-3. Volt-Ampere Curves Duty Cycle Description 8 8 8 SECTION 4-INSTALLATION OR RELOCATION 4-1. Site Selection 8 4-2. Transporting Methods Weld Output Connections Electrical Input Connections 9 4-3. 4-4. No. 9 10 SECTION 5-OPERATOR CONTROLS 5-1. PowerSwitch 5-2. Pilot 12 5-3. Light Output Control 12 5-4. Arc Control/Inductance Control 12 5-5. Contactor Switch 13 5-6. Output Control Switch 13 5-7. CV/CC Switch 14 12 Page Section No. SECTION 6 6-1. 6-2. 6-3. 6-4. 6-5. 6-6. SECTION 7 SEQUENCE OF OPERATION (GMAW) And Flux Cored Arc Welding (FCAW) Welding (GTAW) Tungsten Shielded Metal Ait Welding (SMAW) SubmergedArc Welding (SAW) Air Carbon Arc Cutting And Gouging (ACA) Shutting Down Gas Metal Arc Arc 14 14 15 15 15 15 MAINTENANCE & TROUBLESHOOTING 16 7-1. Routine Maintenance 7-2. Overload Protection 16 7-3. Thermal Protection 17 7-4. 17 7-5. Circuit Board Indicator Lights Circuit Board Handling Procedures 7-6. Troubleshooting 18 SECTION 8 18 ELECTRICAL DIAGRAMS Diagram 8-1. Circuit Diagram 8-2. Circuit Diagram 8-3. Circuit Diagram 8-4. Circuit Diagram 8-5. Circuit Diagram Diagram Diagram Diagram Diagram 21 For Control Circuit Board PCI 22 For Base Drive Circuit Boards PC2 And PC3 24 For Snubber Circuit Board PC4 24 For Balance Circuit Board PC5 25 SECTION 9- PARTS LIST Figure 9-1. Figure 9-2. Figure 9-3. Figure 9-4. Figure 9-5. Main Assembly Panel, Front W/Components 26 28 Baffle, Center W/Components 30 Transistor 32 Assembly, Main Module, Diode 34 LIST OF CHARTS AND TABLES Table 3-1. Chart 3-1. Chart 3-2. Specifications Volt-Ampere Curves Duty Cycle Table 4-1. Weld Cable Size Table 4-2. Input Conductor And Fuse Size 7 7 8 9 11 Table 7-1. Maintenance Schedule 16 Table 7-2. 18 Troubleshooting No. SECTION 1 - SAFETY RULES FOR OPERATION OF INTRODUCTION 1-1. by experience. Learning safety through per experience, like a child touching a hot stove is harmful, wasteful, and unwise. Let the experience of oth sonal teach you. Safe practices developed from experience in the use of welding and cutting are described in this manual. Re search~ development, and field experience have evolved reliable equipment and safe installation, opera tion, and servicing practices. Accidents occur when improperly used or maintained. The rea practices may not always be given. Some are based on common sense, others may require technical volumes to explain. It is wiser to follow the equipment son rules. Read and understand these safe practices before at tempting to install, operate, or service the equipment. Comply with these procedures as applicable to the par ticular equipment used and their instruction manuals, for personal safety and for the safety of others. Failure to observe these safe practices may cause seri ous injury or death. When safety becomes a habit, the equipment can be used with confidence. These safe practices are divided into two Sections: 1-General Precautions, common to arc welding and cut ting; and 2-Arc Welding (and Cutting) (only). Reference standards: Published Standards on safety also available for additional and more complete pro cedures than those given in this manual. They are listed in the Standards Index in this manual. ANSI Z49.1 is the are complete. The National Electrical Code, Occupational Safety and Health Administration, local industrial codes, and local inspection requirements also provide a basis for equip ment installation, use, and service. 12. or cutting, (and chipping) to protect the eyes from radiant energy and flying metal. Replace cover glass when broken, pitted, or spattered. See 1-3A.2. Avoid oily or greasy clothing. A spark may ignite them. Hot metal such as electrode stubs and should never be handled without gloves. workpieces Medical first aid and eye treatment. First aid facilities and a qualified first aid person should be available for each shift unless medical facilities are close by for immediate treatment of flash burns of the eyes and skin burns. is for the safe most POWER SOURCE welding We learn ers ARC WELDING GENERAL PRECAUTIONS Ear plugs should be worn when working on overhead or a confined space. A hard hat should be worn when in others work overhead. Flammable hair preparations should not be used intending to weld or cut. by per sons B. Toxic Fume Prevention Severe discomfort, illness or death can result from fumes, vapors, heat, or oxygen enrichment or depletion that welding (or cutting) may produce. Prevent them with ventilation as described in ANSI Standard Z49.1 listed in Standards Index. NEVER ventilate with adequate oxygen. Lead -,cadmium-, zinc-, mercury-, and beryllium-bear and similar materials, when welded (or cut) may pro duce harmful concentrations of toxic fumes. Adequate local exhaust ventilation must be used,or each person in the area as well as the operator must wear an air-sup plied respirator. For beryllium, both must be used. ing Metals coated with orcontaining materials that emit toxic fumes should not be heated unless coating is removed from the work surface, the area is well ventilated and, if necessary, while wearing an air-supplied respirator. Work in a confined space only while it is being ventilated and, if necessary, while wearing an air-supplied respira tor. Gas leaks in Leaked gas in a confined space should be avoided. Different arc welding processes, electrode alloys, and fluxes can produce different fumes, gases, and large quantities can change oxygen con centration dangerously. Do not bring gas cylinders into a radiation levels. in addition to the Information In this manual, be sure to consult flux and electrode manu facturers Material Safety Data Sheets (MSDSs) for confined space. specific technical data and precautionary measures concerning their material. A. Burn Prevention Wear protective clothing-gauntlet gloves designed for welding, hat, and high safety-toe shoes. Button shirt collar and pocket flaps, and wear cuff less trousers to avoid entry of sparks and slag. use in Wear helmet with safety goggles and glasses with side shields underneath, appropriate filter lenses or plates (protected by clear cover glass). This is a MUST for Leaving confined space, shut OFF gas supply at source prevent possible accumulation of gases in the space if downstream valves have been accidentally opened or to left open. Check to be sure that the space is safe before re-entering it. Vapors from chlorinated solvents can be decomposed by the heat of the arc (or flame) to form PHOSGENE, a highly toxic gas, and other lung and eye irritating prod ucts. The ultraviolet (radiant) energy of the arc can also decompose trichloroethylene and perchloroethylene vapors to form phosgene. DO NOT WELD or cut where solvent vapors can be drawn into the welding or cutting atmosphere or where the radiant energy can penetrate OM-126 853 Page 1 atmospheres containing even minute trichloroethylene or perchloroethylene~ to C. Fire and Explosion Prevention Causes of fire and by the arc, amounts of - explosion are: combustibles reached heated mate gases and cylinders; and flame, flying sparks, hot slag rial; misuse of compressed BE AWARE THAT flying sparks or falling slag can pass through cracks, along pipes, throughwindows ordoors, and through wall or floor openings, out of sight of the goggled operator. Sparks and slag can fly 35 feet. explosion: short circuits. If combustibles are in area, do NOT weld or cut. Move the work if practicable, to an area free of combustibles. Avoid below A container with unknown contents should be cleaned (see preceding paragraph). Do NOT depend on sense of smell or sight to determine if it is safe to weld or cut. castings or containers must be vented welding or cutting. They can explode. Hollow Explosive atmospheres. paint spray rooms, dip tanks, storage areas, venti lators. If the work cannot be moved, move combustibles sparks and heat; or at least 35 feet away out of reach of Never weld may contain flammable dust, gas, as or or before cut where the air liquid vapors (such gasoline). D. Compressed Standard Keep equipment clean and operable, free of oil, grease, and (in electrical parts) of metallic particles that can cause Waterfilling just inerting. or short circuits. To prevent fires and ment as recommended in A6.O. substitute for working level may Gas EquIpment precautions. Comply with precautions in this manual, and those detailed in CGA Standard P-i, SAFE HANDLING OF COMPRESSED GASES IN CYLIN DERS, listed 11 in Standards Index. 1. Pressure Regulators Regulator relief valve is-designed to protect only the regulator from overpressure; it is not intended to protect any downstream equipment. Provide such protection with one or more relief devices. protect against ignition with suitable and snug-fitting, fire-resistant covers or Never connect a shields. regulator cylinder containing gas regulator was designed. to a other than that for which the Walls touching combustibles on opposite sides should not be welded on (or cut). Walls, ceilings, and floor near work should be protected by heat-resistant covers or shields. Remove faulty regulatorfrom service immediately for re pair (first close cylinder valve). The following symptoms indicate a faulty regulator: Fire watcher must be standing by with suitable fire extin guishing equipment during and for some time afterweld ing or cutting if: Leaks-if gas leaks externally. Excessive Creep-if delivery pressure continues to rise with downstream valve closed. a. appreciable combustibles (including building construction) are within 35 feet Faulty Gauge-if gauge pointerdoes not move off stop pin when pressurized, nor returns to stop pin after pressure release. b. appreciable combustibles are further than 35 feet but can be ignited by sparks c. openings (concealed orvisible) in floors orwalls within 35 feet may expose combustibles to d. Repair. Do NOT attempt to repair. Send faulty regulators for repair to manufacturers designated repair center, where special techniques and tools are used by trained personnel. sparks 2. combustibles adjacent to walls, ceilings, roofs, or metal partitions can be ignited by radiant or conducted heat. Cylinders must be handled carefully to prevent leaks and damage to their walls, valves, or safety devices: Hot work permit should be obtained before operation to ensure supervisors approval thatadequate precautions have been taken. After work is done, check that glowing embers, and flames. area is free of sparks, Cylinders Avoid electrical cittuit contact with cylinders including third rails, electrical wires, or welding circuits. They can produce short circuit arcs that may lead to a serious acci dent. (See 1-3C.) ICC or DOT marking must be of safety when the assurance on each cylinder cylinder. It is an is properly han An dled. be welded on or cut, unless container has first been cleaned as described in AWS Standard A6.O, listed 7 in Standards Index. Identifying gas content. Use only cylinders with name of gas marked on them; do not rely on color to identify gas content. Notify supplier if unmarked. NEVER DEFACE or alter name, number, or other markings on a cylinder. It is illegal and hazardous. empty container that held combustibles, or that can produce flammable or toxic vapors when heated, must never This includes: athorough steam or caustic cleaning (or a solvent or water washing, depending on the combusti bles solubility) followed by purging and inerting with ni trogen or carbon dioxide, and using protective equipOM-126 853 Page 2 Empties: Keep valves closed, replace caps securely; keep them separate from FULLS and return promptly. mark MT; Prohibited use. Never use a cylinder or its contents for other than its intended use, NEVER as a support or roller. Locate or secure cylinders so they cannot be knocked over. Passageways and work areas. Keep cylinders clear where they may be struck. of outlet away from people and with a clean lintless cloth. sources of ignition. Wipe Match regulator to cylinder. Before connecting, check that the regulator label and cylinder marking area, and thatthe regulator inlet and cylinderoutlet match. N EVER CONNECT a regulator designed for a particular gas or gases to a cylinder containing any other gas. areas Transporting cylinders. With a crane, use a secure sup port such as a platform or cradle. Do NOT lift cylinders off the ground by their valves or caps, or by chains, slings, or Tighten connections. When assembling threaded con nections: clean and smooth seats where necessary. Tighten. If connection leaks, disassemble, clean, and retighten using properly fitting wrench. mag~nets. Do NOT expose cylinders to excessive heat, sparks, slag, and flame, etc. that may cause rupture. Do not al Cool with water spray low contents to exceed 130F. where such exposure exists. cylinders particularly valves from bumps, falls, falling objects, and weather. Replace caps securely when moving cylinders. Protect hammer orwrench to open a valve that can not be opened by hand. Notify Stuck valve. Do NOT use LEFT HAND threads. Regulatoroutlet (or hose) connections may be identified by right hand threads for oxygen and left hand threads (with grooved hex on nut or shank) for fuel gas. 5. a cylinder your supplier. Mixing gases. Adapters. Use a CGA adapter (available from your sup plier) between cylinder and regulator, if one is required. usetwowrenchestotighten adaptermarked RIGHTand Pressurizing Steps: regulator of residual gas through suitable vent be opening cylinder (or manifold valve) by turning ad justing screw in (clockwise). Draining prevents exces sive compression heat at high pressure seat by allowing seat to open on pressurization. Leave adjusting screw engaged slightly on single-stage regulators. Drain fore Never try to mix any gases in Never refill any a cylinder. cylinder. Cylinderfittings should never be modified orexchanged. Stand to side of regulator while opening cylinder valve. 3. Hose Prohibited use. Never use hose otherthan that designed for the specified.gas. A general hose identification rule is: red for fuel gas, green for oxygen, and black for inert gases. Use ferrules or clamps designed for the hose (not ordi nary wire or other substitute) hoses to fittings. No copper tings to tubing splices. splice hose. as a Use binding only to connect standard brass fit Avoid long runs to prevent kinks and abuse. Suspend hose off ground to keep it from being run over, stepped on, or otherwise damaged. Open cylinder valve slowly so that regulator pressure in creases slowly. When gauge is pressurized (gauge reaches regulator maximum) leave cylinder valve in fol lowing position: For oxygen, and inert gases, open rully to seal stem against possible leak. For fuel gas, open to less than one turn to permit quick emergency shutoff. Use pressure charts (available from your supplier) for safe and efficient, recommended pressure settings on regulators. Check for leaks on first pressurization and regullarly there-after. Brush with soap solution (capfull of Ivory Liq uid* or equivalent per gallon of water). Bubbles indicate leak. Clean off soapy water after test; dried soap is com bustible. Coil excess hose to prevent kinks and tangles. E. Protect hose from damage by sparks, slag, and open flame. sharp edges, and area out and splic leaky or defective equipment from service im mediately for repair. See User Responsibility statement in equipment manual. F. Leaving Equipment Unattended Close gas supply at G. 4. ResponsIbilitIes Remove Examine hose regularly for leaks, wear, and loose con nections. Immerse pressured hose in water; bubbles in dicate leaks. Repair leaky orwom hose by cutting ing (1-203). Do NOT tape. User by source and drain gas. Rope Staglng.Support Proper Connections Clean cylinder valve outlet of impurities that may clog orifices and damage seats before connecting regulator. Except for hydrogen, crack valve momentarily, pointing Rope staging-support should not be cutting operation; rope may burn. used for welding or *Trademark of Proctor & Gamble. OM-1 26 853 Page 3 ARC WELDING 1-3. Comply with precautions in 1-1, 1-2, and this section. Arc Welding, properly done, is a safe process, but a careless operator invites trouble. The equipment carries high currents at significant voltages. The arc is very bright and hot. Sparks fly, fumes rise, ultraviolet and in frared energy radiates, weldments are hot, and com pressed gases may be used. The wise operator avoids unnecessary risks and protects himself and others from accidents. Precautions are described here andin stan dards referenced in index. A. Others working in flash area. See that all persons goggles. Before starting are wearing - to weld, make sure that screen bay doors are closed. B. ToxIc Fume PreventIon Comply With precautions flaps or in 1-2B. Generator engine exhaust must be vented to the outside air. Carbon monoxide can kill. Protection Burn Comply Viewing the weld. Provide face shields for all persons who will be looking directly at the weld. C. with precautions Fire and Explosion Prevention in 1-2. Comply with precautions in 1 -2C. The welding arc is intense and visibly bright. its radiation can damage eyes, penetrate lightweight clothing, reflect from light-colored surfaces, and burn the skin and eyes. Equipments equipment. Skin burns resemble acute sunburn, those from gasshielded arcs are more severe and painful. DONT GET BURNED; COMPLY WITH PRECAUTIONS. cause a 1. Protective Clothing Wear long-sleeve clothing (particularly for gas-shielded gloves, hat, and shoes (1 -2A). As nec essary, use additional protective clothing such as leather jacket or sleeves, flame-proof apron, and fire-re sistant leggings. Avoid outer garments of untreated cot arc) in addition to ton. Bare skin protection. Wear dark, substantial clothing. Button collar to protect chest.and neck and button pock ets to prevent 2. Eye rated capacity. Do not overload arcwelding It may overheat cables and cause a fire. Loose cable connections may overheat fire. or flash and - Never strike an arc on a cylinder or other pressure ves sel. It creates a brittle area that can cause a violent rup ture or lead to such a rupture under rough handling. D. Compressed Gas Equipment Comply with precautions E. in 1 -2D. Shock Prevention Exposed hot conductors or other bare metal in the weld ing circuit, or in ungrounded, electrically-HOT equip ment can fatally shock a person whose body becomes a conductor. DO NOT STAND, SIT, LIE, LEAN ON, OR TOUCH a wet surface when welding, without suitable entry of sparks. and Head Protection protection. Protect eyes from exposure to electric arc without protection. arc. NEVER look at an To protect against shock: Wear Welding helmet or shield containing a filter plate shade no. 12 or denser must be used when welding. Place over face before striking arc. Protect filter plate with a clear cover plate. dry insulating gloves and body protection. Keep body and clothing dry. Never work in damp area without adequate insulation against electrical shock. Stay on a dry duckboard, or rubber mat when dampness or sweat can not be avoided. Sweat, sea water, or moisture be Cracked or broken helmet or shield should NOT be worn; radiation can pass through to cause bums. body and an electrically HOT part or grounded metal reduces the electrical resistance, and could en able dangerous and possibly lethal currents to flow Cracked, broken, through tween IMMEDIATELY. pitted1 or loose filter plates must be replaced Replace clear cover plate when broken, or spattered. Flash goggles with side shields MUST be worn under the helmet to give some protection to the eyes should the helmet not be lowered over the face before an arc is the body. A voltage will exist between the electrode and any con ducting object in the work circuit. Examples of conduct ing objects include, but are not limited to, buildings, elec trical tools, work benches, welding power source cases, struck. workpieces, etc. Never touch the electrode and any metal object unless the welding power source is off. eyes 1. Looking at an arc momentarily with unprotected (particularly a high intensity gas-shielded arc) can retinal burn that may leave a permanent dark in the field of vision. Grounding the Equipment cause a area 3. Protection of Enclosed welding Nearby Personnel For production welding, a sepa bay is best. In open areas, sur round the operation with low-reflective, non-combusti ble screens or panels. Allow for free air circulation, par area. rate room or enclosed ticularly at floor level. OM-126 853 Page 4 Arc welding equipment must be grounded according to the National Electrical Code, and the work must be grounded according to ANSI Z49.1 usafety In Welding And Cutting. When installing, connect the frames of each unit such as welding power source, control, worktable, and water cir culatorto the building ground. Conductors must be ade quate to carry ground currents safely. Equipment made Welding power sources used with shielded metal arc welding (SMAW) and similar proc esses may not be equipped with welding power output on-off control devices. With such equip ment the electrode is electrically HOT when the electrically HOT by stray current may shock, possibly I atally. Do NOT GROUND to electrical conduit, orto a pipe carrying ANY gas or flammable liquid such as oil or fuel. Three-phase connection. Check phase requirements of equipment before installing. If only 3-phase power is available, connect single-phase equipment to only two wires of the 3-phase line. Do NOT connect the equip ment ground lead to the third (live) wire, or the equip ment will become electrically HOT-a dangerous condi tion that can shock, possibly fatally. welding, check ground for continuity. Be sure conductors are touching bare metal of equipment Before frames at connections. line cord with a ground lead is provided with the equipment for connection to a switchbox, connect the ground lead to the grounded switchbox. If a three-prong If a plug is added for connection to a grounded mating re ceptacle, the ground lead must be connected to the ground prong only. If the line cord comes with a threeprong plug, connect to a grounded mating receptacle. Never remove the ground prong from a plug, or use a plug with a broken off ground prong. 2. Connectors Fully insulated lock-type join welding cable lengths. Cables Frequently inspect cables forwear, cracks and damage. IMMEDIATELY REPLACE those with excessively worn or damaged insulation to avoid possibly-lethal shock from bared cable. Cables with damaged areas may be taped to give resistance equivalent to original cable. Keep cable dry, free of oil and grease, and from hot metal and sparks. 5. Terminals And Other devices such as interlocks and circuit breakers should not be disconnected or shunted out. Before installation, inspection, or service, of equipment, shut OFF all power and remove line fuses (or lock or redtag switches) to prevent accidental turning ON of power. Disconnect all cables from welding power source, and pull Leaving equipment Exposed b. shut OFF and near ProtectIon For Wearers of ElectronIc Life port DevIces (Pacemakers) the 1-4. STANDARDS BOOKLET INDEX For more information, referto the their latest revisions and comply 1. following standards or as applicable: ANSI Standard Z49.1, SAFETY IN WELDING AND CUTTING obtainable from the American Welding Society, 550 N.W. LeJeune Ad, Miami, FL 33126. NIOSH, SAFETY AND HEALTH IN ARC WELDING AND GAS WELDING AND CUTTING obtainable from the ernment 3. (no Superintendent of Documents, U.S. Gov Printing Office, Washington, D.C. 20402. OSHA, SAFETY AND HEALTH STANDARDS, 29CFR 1910, obtainable from the Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402. 4. ANSI Standard Z87.1, SAFE PRACTICES FOR OCCUPATION AND EDUCATIONAL EYE AND. FACE PROTECTION obtainable from the American National Standards Institute, 1430 Broadway, New York, NY 10018. 5. ANSI Standad Z41.1, STANDARD FOR MENS SAFETY-TOE FOOTWEAR obtainable from the American National Standards Institute, 1430 Broad way, New York, NY 10018. 6. ANSI Standard Z49.2, FIRE PREVENTION IN THE USE OF CUTTING AND WELDING PROCESSES in contact with the electrode circuit unless source is off. without output on/off control Sup Magnetic fields from high currents can affect pacemaker operation. Persons wearing electronic life support equipment (pacemaker) should consult with their doctor before going near arc welding, gouging, or spot welding operations. welding power Equipment contactor) Always equipment. F. 2. Parts Welding power sources for use with the gas metal arc welding (GMAW), gas tungsten arc welding (GTAW) and similar processes nor mally are equipped with devices that permit on off control of the welding power output. When so equipped the electrode wire becomes electri cally HOT when the power source switch is ON and the welding gun switch is closed. Never touch the electrode wire or any conducting ob the plugs. unattended. disconnect all power to Equipment with output on/off control (contactor) ject all 115 volts line-cord Do not open power circuit or change polarity while weld ing, If, in an emergency, it must be disconnected, guard against shock burns, or flash from switch arcing. protected Electrode a. Devices Safety Terminals and other exposed parts of electrical units should have insulating covers secured before operation. 6. Safety welding power source. be used. Do connectors should be used to 4. 7. Power disconnect switch must be available Electrode Holders Fully insulated electrode holders should NOT USQ holders with protruding screws. 3. power switch is turned ON. Never touch the electrode unless the welding power source is off. OM- 126 853 Page 5 from the Compressed Gas Association, 1235 Jeffer son Davis Highway, Suite 501, Arlington, VA 22202. AWS Standard A6.0, WELDING AND~ CUTTING CONTAINERS WHICH HAVE HELD COMBUS TIBLES obtainable from the American Welding So ciety, 550 N.W. LeJeune Rd, Miami, FL 33126. 12. CSA Standard W117.2, CODE FOR SAFETY IN WELDING AND CUTTING obtainable from the Ca 7. obtainable from the American National Standards Institute, 1430 Broadway, New York, NY 10018. NFPA Standard 51, OXYGEN-FUEL GAS SYS TEMS FOR WELDING, CUTTING, AND ALLIED PROCESSES obtainable from the National Fire Protection Association, Batterymarch Park, Quincy, 8. Standard 70, NATIONAL ELECTRICAL CODE obtainable from the National Fire Protection NF?A Association, Batterymarch Park, Quincy, MA 02269. 10. NFPA Standard 51B, CUTTING AND WELDING PROCESSES obtainable from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. ii. CGA Pamphlet P-i, SAFE HANDLING OF COM PRESSED GASES IN CYLINDERS obtainable SECTION 2 2.1. 13. NWSA booklet, WELDING SAFETY BIBLIOGRA PHY.obtainable from the National Welding Supply Association, 1900 Arch Street, Philadelphia, PA 19103. MA 02269. 9. nadian Standards Association, Standards Sales, 178 Rexdale Boulevard, Rexdale, Ontario, Canada M9W1R3. Welding Society Standard AWSF4.1, RECOMMENDED SAFE PRACTICES FOR THE PREPARATION FOR WELDING AND CUTTING OF CONTAINERS AND PIPING THAT HAVE HELD HAZARDOUS SUBSTANCES, obtainable from the American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126. 14. American 15. ANSI Standard Z88.2, PRACTICE FOR RESPIRA TORY PROTECTION, obtainable from the Ameri can National Standards Institute, 1430 Broadway, New York, NY 10018. SAFETY PRECAUTIONS AND SIGNAL WORDS GENERAL INFORMATION AND SAFETY A. General Information presented in this manual and on various la bels, tags, and plates on the unit pertains to equipment design, installation, operation, maintenance, and troubleshooting which should be read, understood, and followed forthe safe and effective use of this equipment. 2-2. SAFETY WORDS B . Safety The installation, operation, maintenance, and trouble shooting of arc welding equipment requires practices and procedures which ensure personal safety and the safety of others. Therefore, this equipment is to be in stalled, operated, and maintained only by qualified per Sons in accordance with this manual and all applicable codes Such as, but not limited to, those listed at the end of Section 1 Safety Rules For Operation Of Arc Weld ing Power Source. OM-126 853 Pages SYMBOL AND SIGNAL The following safety alert symbol and signal words are used throughout this manual to call attention to and iden tify different levels of hazard and special instructions. a This safety alert symbolis used with the signal words WARNING and CAUTION to call atten tion to the safety statements. a WARNING statements identify procedures or practices which must be followed to avoid seri ous personal injury or loss of life. a CAUTION statements identify procedures or practices which must be followed to avoid minor personal injury or damage to this equipment. The nameplate of this unit uses international symbols for labeling the front panel controls. The symbols also ap pear at the appropriate section in the text. ALERT IMPORTANT statements identify special instructions necessary for the most efficient operation of this equip ment. SECTION 3- SPECIFICATIONS Table 3-1. SpecifIcations At Rated Load Output 50/60 input Max. Input Power Rated Output At 100% Duty Cycle VoltageRange Amperage Range in in CV Mode CC Mode Open-Circuit Voltage in CC Mode Weight Hz_ Amperes At 230V 460V kva kw 42 21 16.7 13.8 Net Ship 150 lbs. 164 lbs. (68 kg) (74 kg) ~ ThreePhase 350 Amperes At 34 Volts DC 10-35 Volts SinglePhase 5-350 70 Volts DC Amperes 275 Amperes 31 Volts DC 14.3 30 60 10 Base inches Millimeters 1-9/16 39.7 B 13 330.2 C 23 584.2 0 25.13/32 645.3 E 25/32 19.8 A K F 3/4 19.0 G 11-1/2 292.1 H 13 330.2 J 23 584.2 K 26-1/4 666.8 J B holes C Meunting Hole Layout holes are are 3/8 In. (9.5 14/32 in. mm) Die. (4 hole,) (13.5 mm) DIe. (4 holes) TC-131 955 Figure 3-1. Overall Dimensions Chart 3-1. And Base Mounting Hole Layout Volt-Ampere Curves N N N 0 U N I 0 I. U. U. U. U. U. u~. DC AMPERE5 N IN IN ZN ZOO ZOO DC AMPE~E3 8-099012 Volt-Ampere Curves For CV Mode (With 3-Phase, 60 Hz Input) e-ogct 013 Volt-Ampere Curves For CC Mode (With 3-Phase, 60 Hz Input) OM-126 853 Page 7 unit can be operated at rated load continuously, If the welding amperes increase beyond rated output, the duty cycle decreases. VOLT-AMPERE CURVES (Chart 3-1) 3-1. RATED OUTPUT The volt-ampere curves age output capabilities Curves of other settings show the voltage and amper of the welding power source. fall between the curves shown. With the use of the volt-ampere curves, it is possible to determine the weld amperage at any particular load volt Refer to the Duty Cycle chart (Chart 3-2) to determine Output of the welding power source at various duty the cycles. a CYCLE DUTY EXCEEDING CAUTION: RATiNGS will damage the welding power source. Do not exceed indicated age. DUTY CYCLE 3-2. duty cycles. (Chart 3-2) 3-3. Cycle Chart 3-2. Duty DESCRIPTION a three-phase, or single-phase if derated, dc, welding power source having constant voltage (CV) and constant current (CC) output characteristics for multi-process capability. The unit produces dc weld out put and is designed for-use with Shielded Metal Arc (SMAW), Gas Metal Arc (GMAW), Gas Tungsten Arc (GTAW), Flux Cored Arc (FCAW), Submerged Arc (SAW), and Air Carbon Arc (ACA) cutting and gouging welding processes. This unit is arc 350~, 300 2~0 200 ___________________________________ .5 20 30 2~ :ury CyCLE 40 60 50 0 Sc 90 00 C a-ia 983 duty cycle is the percentage of a ten minute period welding power source can be operated at a given output without overheating and damaging the unit. This welding power source is rated at 100% duty cycle. The The that a This unit is capable of both pulsed and no npuised operation. The welding power source compensates for line voltage fluctuation of –10%. The solid-state, electronic components of this unit are lo cated in sealed areas unexposed to airflow and asso ciated contaminants. The fan motors cool only the heat sinks and main transformer. SECTION 4- INSTALLATION OR RELOCATION 4.1. SITE SELECTION Base mounting holes provide the capability to install and the unit on a running gearor in a permanent loca tion. Figure 3-1 gives overall dimensions and base mounting hole layout. secure Select an installation site which provides the 1. Correct input power 2. Shielding gas supply (if applicable) 3. Water 4. Adequate ventilation 5. No flammables 6. A clean and supply (see unit following: nameplate) supply (if applicable) and fresh air supply 4A WARNING: FIRE OR EXPLOSION can result from placing unit on or over combustible surfaces; RESTRICTED AIRFLOW can cause overheating and possible damage to Internal parts. 7. dry Do not locate unit over combustible surfaces. area Proper temperature that avoids extremes of heat or Maintain at least 6 inches (152 mm) of unrest ricted space on tight side of unit, and keep underside free of obstructions, cold airflow around unit 8. Proper 9. Adequate space for removing top cover and outer panels for installation, maintenance, and repair functions. OM-1 26 853 Pages Do not place any filtering device over the in take air passages that pro vide airflow forcoollng this unit. Warranty is void if any type of filtering device used at intake air passages. is 4-2~ TRANSPORTiNG METHODS This welding power lift forks. a - Use weld cable with an insulation voltage rating equal to or greater than the maximum open-circuit voltage (ocv) of the welding power source (see Table 3-1 for unit maximum ocv rating). 3. Select welding cable size according to maximuim weld output and total length of connecting cables in weld circuit. For example, if a 25 foot (7.5 m) wi~re feeder or electrode holder cable is used with a 25 foot ~7.5 m) work cable, select the cable size recom mended in Table 4-1 for 50 feet (15 m). 4. Do not B. Weld Cable 1. Installterminallugs of adequate amperage capacity has space underneath it for source WARNING: ELECTRIC SHOCK ~ 2. can kill. Do not touch live electrical parts. Disconnect input power conductors from deenergized supply line BEFORE moving weld ing power source. FALLING EQUIPMENT can cause serious personal injury and equipment damage. Use equipmentof adequate capacity to lift the unit. If lifting or moving this unit with lift forks under the base, be sure that lift folks are long enough to extend beyond opposite side of the base. WELD OUTPUT CONNECTIONS 1. 3. Install work clamp onto cable. (Figure 5-1) C. Weld Cable Connections To Source (Figure 5-1) or cause Welding Povier POSITIVE NEGATIVE + a WARNING: ELECTRIC SHOCK can kill. Do not touch live electrical parts. Shutdown welding powersource, and discon input power employing lockout/tagging procedures before inspecting or installing. Lockout/tagging procedures consist of pad locking line disconnect switch in open position, removun~ fuses from fuse box, or shutting off and red-tagging circuit breaker or other disconnect ing device. nect to select weld cables: possible cables, and place cables lengths may reduce close together. Excessive cable output Preparation If installing an electrode holder, follow manufactur ers installation instructions. Always use an insu lated electrode holder to ensure operator safety. Weld Cable SelectIon Use the shortest cables. 2. welding performance. following guidelines frayed weld output terminals. To obtain full rated output from this unit, it is necessary to select, prepare, and install properwØld cables. Failure to comply in any of these areas may result in unsatisfactory Use the or and correct stud size onto cables that connect to the clamp, wire feeder or electrode holder, and RATED OUTPUT A. damaged work Using lift forks too short can damage internal parts if tips of the lift forks penetrate the unit base, or may cause personal injury and/or equipment damage if unit falls off the lift forks. 4-3. use unit overload due to added resis tance. Table 4-1. Weld Cable Size Total Cable (Copper) Length In Weld Circuit Not Exceeding 100 ft. Or Less 150 ft. 200 ft. 1 250 ft. 300 ft. 350 ft. (30 m) (45 m) (60 m) j (70 m) (90 m) (105 m) 400 ft. (120 m) 10 To 60% 60 Thru 100% Duty Cycle Duty Cycle 4 4 4 3 2 1 1/0 1/0 3 3 2 1 1/0 2/0 3/0 3/0 3 2 1 1/0 2/0 3/0 4/0 4/0 2 1 1/0 2/0 3/0 4/0 2-2/0 2-2/0 weld cable size mils per ampere. 10 Thru 100% Duty Cycle 1 1/0 2/0 3/0 4/0 2-2/0 2-3/0 2-3/0 1/0 2/0 3/0 4/0 2-2/0 2-3/0 2-3/0 2-4/0 1/0 2/0 3/0 4/0 2-2/0 2-3/0 2-4/0 2-4/0 2/0 3/0 4/0 2-2/0 2-3/0 2-4/0 3-3/0 3-3/0 3/0 4/0 2-2/0 2-3/0 2-4/0 3-3/0 3-4/0 3-4/0 (AWG) is based on either a 4 volts or less drop or a current density of more than 300 circular S.0007/8.88 OM-126 853 Page 9 1. For Shielded Metal Arc Welding Positive/Reverse Polanty) (SMAW) (Electrode locking a. Connect end of electrode holder cable to POSI TIVE (+) weld output terminal. b. Connect one end of work cable to NEGATIVE () weld output terminal and remaining end to workpiece. consist of pad line disconnect switch in open position, removing fuses from fuse box, or shutting off and red-tagging circuit breaker or other disconnecting device. Lockout/tagging procedures - A. ElectrIcal Input Requirements Operate the welding power source from a three-phase, single-phase if derated, 50/60 Hertz, ac power supply. The input voltage must match one of the electrical input voltages shown on the input data label on the unit name plate. Contact the local electric utility for information or IMPORTANT: For Electrode Negative/Straight Polarity connections, reverse cable connections to weld output terminals; electrode becomes negative. 2. Fo~ Welding (GMAW), Flux Cored Arc Welding (FCAW), and Submerged Arc Welding (SAW) (Electrode Positive/Reverse Polarity) Gas Metal Arc Connectneendofweldcableto POSITIVE(+) weld output terminal and remaining end to ter a. minal on drive feeder Owners b. of wire feeder Manual for location). housing (see wire Connect one end of work cable to NEGATIVE () weld output terminal and remaining end to workpiece. IMPORTANT: For Electrode Negative/Straight Polarity connections, reverse cable connections to weld output terminals; electrode becomes negative. 3. about the type of electrical service available, how proper connections should be made, and inspection required. B. a Remove top cover and left side 2. Compare position of jumper links on the input termi nal board and terminal strip 1 T to the voltage link ar rangement shown on input voltage label. a Position jumper links Cutting Gouging (ACA) (Electrode Positive/Reverse Polarity) Connect b. one end of work cable to NEGATIVE and remaining end to () weld output terminal workpiece. IMPORTANT: For Electrode Negative/Straight Polarity connections, reverse cable connections to weld output terminals; electrode (torch) becomes negative. 4.4. ELECTRICAL INPUT CONNECTIONS INPUT AA WARNING: ELECTRIC SHOCK can kIll. Do not touch live electrical parts. Shutdown welding powersource, and discon input power employing lockout/tagging procedures before inspecting or installing. nect OM-126 853 Page 10 shown on the input across linked terminals. And Connect torch cable to POSITIVE (+) weld out put terminal. as label (see Figure 4-1). Store unused jumper links 3. For Air Carbon Arc panel. CAUTION: INCORRECT INPUT VOLTAGE JUMPER LINK PLACEMENT can damage unit. voltage IMPORTANT: For Electrode Positive/Reverse Polarity connections, reverse cable connections to weld output terminals; electrode (torch) becomes positive. a. proceedIng. 1. piece. 4. WARNING: Read and follow safety Info rma tlon at beginning of entire SectIon 4-4 before to NEGA Connect one end of work cable to POSITIVE (+) weld output terminal and remaining end to work- b. (FIgure 4-1) bag attached to the input terminal board and terminal strip 11 or installed for the highest voltage shown on the input voltage label. Tungsten Arc Welding (GTAW) (Electrode Negative/Straight Polarity) Connect torch cable or connector TIVE () weld output terminal. Link InstallatIon Jumper links are used to allow the equipment to operate from different line voltages. The jumper links may be in a For Gas a. Jumper Install jumper links onto the input terminal board and terminal strip iT to match the available input line voltage. 4 Reinstall and secure left side panel and top cover onto unit. C. Welding Power Source Input Power Connec (Figure 4-1) tions a WARNING: ELECTRIC SHOCK can kill. Do not touch live electrical parts. Install a fusible line disconnect switch in the input circuit to the welding power source. Connect input conductors to the welding power source before connecting to singlephase or three-phase input power. Read and follow safety information at be ginfling of entire Section 4-4 before proceeding. The line disconnect switch provides a safe and convenient means to completely remove all electrical power from the welding power source whenever it is necessary to inspect or service the unit. 2. Use Table 4-2 as a guide to select input conductors for the installation. The input conductors should be covered with an insulating material that complies with national, state, and local electrical codes. 8. 9. WARNING: ELECTRIC SHOCK can kill. 11. Use Table 4-2 as a conductor to Table 4.2. result in an 3 Remove 4. Obtain and install astandard conduit strain relief connector into access hole in cover plate. 5. plate from rear Power ThreePhase panel. Conductor Size Ground Conductor Size Fuse Size In (AWG) (AWG) Amperes 230 8 10 60 460 1-0 10 30 230 6 10 60 8 10 40 Phase 460 Insert conductors through strain relief installed in 4. Route conductors to input terminals. tConductor size is based on the 1987 Edition of the National Electrical Code (NEC) specifications for allowable am pacities of insulated copper conductors, having a tempera For three-phase input supply: Connect ductors to line terminals, L2, and L3. ture input con rating of 167F (75C), with not more than three single current-carrying conductors in a raceway (Article 310 of NEC). (The ground conductor is not counted as a currentcarrying conductor.) For single-phase input supply: Connect input con ductors to the top Li and bottom L3 terminals. tFuse size is based 7. And Fuse Slze* Input Voltage Single- Step 6. Input Conductor an electrically energized welding power source chassis. The ground terminal is connected to the welding power source chassis and is for grounding purposes only. cover guide to select line fuses for the Input can to a disconnect switch. Obtain and install proper fuses. Input input connections a com remaining ends of input conductors deenergized line disconnect switch. input line terminal. Incorrect secure in Connect remaining end of ground conductor to Do not connect an input conductor to the ground terminal in the unit. ground panel, and 10. Connect Do not (ouch live electrical parts. Do not connect the rear suitable ground. Use a grounding method that plies with all applicable electrical codes. Install terminal Iugs of adequate amperage capacity and correct stud size onto the input and ground con ductors. A~ Reinstallcover plate onto put cable in strain relief connector. ~ 1. Connect the nal ground conductor to the ground termi (see Fig~ire 4-1). Ground on not more rated input amperage of the 630 of NEC). Center Panel Contactor than 200 percent of the welding power source (Article s-oogeił-aa Fuse Fl Conductor Piinel Input Terminal Board With Input Voltage Jumper Unks Terminal With Strip 11 Jumper Links Line Disconnect Switch: Three-Phase System Shown Route To Unit: Rear Panel Access Hole Is 1-3/8 in. (34.9 mm) In Diameter 18-096 967-A FIgure 4-1. Component Locations And Input Conductor ConnectIons OM-126 853 Page 11 SECTION 5- OPERATOR CONTROLS CV/CC Switch Output Control Output Control Switch Circuit Breaker CB1 (+) Weld Output Terminal Positive Power Switch ON Push Button Negative () Weld Output Terminal Power Switch OFF Pilot Ught Push Button TC-131 955 Figure 5-1. 5-1. POWER SWITCH (Figure 5-1) 5-3 ON POWER -e Front Panel View Q OFF OUTPUT CONTROL (FIgure 5-1) The OUTPUT control provides a means of selecting the desired output within the entire range of the welding power source. The control adjusts the voltage level(V) in the CV mode and the amperage level (A) in the CC mode from minimum to maximum of power source capability. Rotating the control clockwise increases weld output, and rotating the control counterclockwise decreases weld output. gizes Depressing the POWER switch ON push button ener the welding power source. Depressing the POW ER switch OFF push button shuts down the welding IMPORTANT: The OUTPUT control may be adjusted while welding. power source. 5-4. ARC CONTROL/INDUCTANCE CONTROL (FIgure 5.1) IMPORTANT: After any interruption of input power. the POWER switch ON push button must be depressed to reenergize the welding power source. 5-2. PILOT LIGHT The (Figure 5.1) pilot light comes on when the POWER switch ON button is depressed and indicates that the unit is ener gized. OM-126 853 Page 12 The ARC CONTROL/INDUCTANCE control functions as an arc control in the constant current (CC) mode and as an inductance control in the constant voltage (CV) mode. IMPORTANT: The ARC CONTROL/INDUCTANCE control may be adjusted while welding. The control should be set at 0 (zero) for Gas Tungsten Arc Welding (GTAVV9. Arc Control (Used in CC Mode For Shielded Metal Arc Welding (SMAW) And Air Carbon Arc Cut ting And Gouging (ACA) Processes) A. a - The ARC CONTROL When the control is set at 100, the short-circuit current is higher (upto 150 amperes) than normal welding current. (See volt-ampere curve for CC mode and IMPORTANT beginning of this Subsection.) The increased current enables arc starting in out-of-position welds, and it provides the momentary overcurrents necessary for block at certain types of electrodes. When the control is set at 0 (zero), short-circuit current is the same as the welding current. When the control is set at 50, short-circuit current is ap proximately halt that of the 100 position, but still higher than normal welding current. The 50 position provides a moderate current increase necessary for arc starting certain applications and types of electrodes. Select a setting best suited for the application and type of electrode. B. lnductanc~Control (Used For Constant Voltage (CV) Operations Only) Rotating this control clockwise electronically increases inductance. As the level of inductance increases, the rate of current change or speed of response slows down. The slower response time produces a softer arc, more fluid welding puddle, and flatter, smoother bead. If CONTACTOR switch is in ON position arid wire feeder or remote control device is con nected to terminal strip lOT, weld output (ocv) will be present whenever the weldi rig power source is energized. Although the term CONTACTOR is used nameplate, the output is not switched on or off by a physical output contactor; rather, the output is Con trolled by relay action andsolid-state components on cir IMPORTANT: on the cuit boards. When the CONTACTOR switch is in the ON position, open-circuit voltage (ocv) is present at the weld output terminals whenever the welding power source is erier gized. When the switch is in the OFF/REMOTE position, no voltage is available at the output terminals ocv goes to 0 (zero) volts. If awire feeder or remote control device is controlling the contactor, place the CONTACTOR switch in the OFF/ REMOTE position. Open-circuit voltage will be present at the weld output terminals whenever the gun trigger or remote control device is closed. The CONTACTOR switch is normally placed in the OFF! REMOTE position with the Gas Tungsten Arc Welding Gas process and all wire feeding processes Metal Arc Welding (GMAW), Flux Cored Arc Welding (FCAW), and Submerged Arc Welding (SAW). The switch is normally placed in the ON position for the Shielded Metal Arc Welding (SMAW) and the Air Carbon Arc (ACA) cutting and gouging processes. (GTAW) 5-6. -- OUTPUT CONTROL SWITCH (Figure 5-1) 4A WARNING: ELECTRIC SHOCK or if the CONTACTOR switch Si is in the ON characteristics; for example, a soft, slow-respond low spatter arc, and high weld puddle fluidity. tance 5-5. a setting best suited for the CONTACTOR SWITCH A~ position and Output Control switch (PANEL! REMOTE) is in the PANEL position, opencircuit voltage is present at the output termi nals whenever the welding power source is energized. application. (Figure 5-1) WARNING: ELECTRIC SHOCK can Do not touch gun wire and work clamp at the same time. kill. Do not touch live electrical parts. Do not touch the weld output terminals or any metal pails of the welding circuit when the contactor is energized. If CONTACTOR switch Si is in the ON posi tion and Output Control switch (PANEL! REMOTE) S3 is in the PANEL position, open-circuit voltage is present at the output terminals whenever the welding power source is energized. kill. Do not touch the weld output terminals any metal parts of the welding circuit when the contactor is energized. (zero) setting gives minimum inductance; for ex ample, a stiff, fast-responding arc, and a small, fastfreezing puddle. The 100 setting gives maximum induc Select can Do not touch live electrical parts. The 0 ing, Do not touch gun wire and work clamp at the same time. Place CONTACTOR switch in OFF! REMOTE position when using wire feeder or remote control device to control contactor. IMPORTANT: The maximum ARC CONTROL current available is 150 amperes above the ampere value Se lectedon the OUTPUTcontro!. However, unit output, in cluding ARC CONTROL amperes, cannot exceed the rated output of the welding power- source. (See voltampere curves for CC mode.) provides variable selection of short-circuit current to suit individual welding conditions. Rotating this control clockwise causes the current to in crease as the short-circuit condition is approached. . If remote contactor control is desired, make proper con nections to terminal strip 1 OT, and place the Output Con trol switch in the REMOTE position. Open-circuit voltage (ocv) will be present at the weld output terminals when ever the remote control device is closed. If remote contactor control is not desired, place the Out put Control switch in the PANEL position. Open-circuit voltage (ocv) will be present at the output terminals whenever the welding power source is energized. OM-126 853 Paie 13 5-7. CVICC SWITCH (Figure 5-1) The CV/CC switch provides a means of selecting weld output characteristics for the desired process. When the switch is in the CV (constant voltage) position, the unit provides a constant voltage output specifically designed Gas Metal Arc Welding for wire feeding applications -- SEQUENCE OF OPERATION SECTION 6 a (GMAW), Flux Cored Arc Welding (FCAW), and Shielded Metal Arc Welding (SAW). When the switch is in the CC (constant current) position, the unit provides a constant current output specifically designed for Shielded Metal Arc Welding (SMAW) and Gas Tungsten Arc Welding (GTAW). The CC position is also used for the Air Carbon Arc (ACA) cutting and gouging process. ELECTRIC SHOCK can kill; WARNING: MOVING PARTS can cause serious injury; IMPROPER AIRFLOW AND EXPOSURE TO ENVIRONMENT can damage Internal parts. 2. Install and prepare wire feeder according to its Own ers Manual. 3. Place the CONTACTOR REMOTE position. 4. Place the CV/CC switch in the CV 5. Place the applicable Output Control switch in the desired position (see Section 5-6). Do not touch live electrical parts. Keep all covers and panels in place while operating. Warranty is void if the welding power source is operated with any portion of the outer enclosure 6. removed. ARC RAYS, SPARKS, AND HOT SURFACES burn eyes and skin; NOISE can damage can the OFF/ position. Rotate the applicable OUTPUT Control (panel or re to the desired position (see Section 5-3). mote) 7. Rotate the INDUCTANCE control to the desired position (see Section 5-4B). hearing. Wear correct eye, ear, and FUMES AND GASES can your health. Keep in switch body protection. seriously harm 8. ANSI Z49.1. your head out of the fumes. 9. keep from breathing fumes and Ventilate to dry insulating gloves and clothing, and wear welding helmet with proper filter lens according to Wear Prepare for welding as follows: Connect work clamp to clean, bare metal at a. gases. workpiece. If ventilation is inadequate, use approved WELDING wounds. WIRE can puncture cause Do not point gun toward any part of the body, any conductive surface, or other personneL HOT METAL, SPATrER, and burns. AND SLAG can Manual. 10. Turn 12. 5-2. Watch for fire. Do not use extinguisher nearby, near Allow work and and know equipment to cool before supply if applicable. TUNGSTEN ARC WELDING (GTAW) WARNING: Read and follow safety Informa beginning of entIre Section 6 before tion at proceeding. 1. Install and connect unit 2. Install and connect the High-Frequency unit accord ing to its Owners manual if applicable. Scratch start Gas Tungsten-Arc Welding does not require the use of external high frequency. 3. Place the CONTACTOR REMOTE position. 4. Place the CV/CC switch in the CC position. Wearers should consult their doctor before going neararc welding, gouging, orspot welding operations. - gas Begin welding. a MAGNETIC FIELDS FROM HIGH CURRENTS can affect pacemaker operation. Arc shielding flammable material. handling. See Section 1 on 11. Press the POWER switch ON button. cause tire Keep a fire how to use it. Select and obtain proper welding wire, and thread as instructed in wire feeder Owners b. breathing device. Safety Rules Welding Power Source safety information. For Operation Of for basic welding 5. Place the tion according to Section 4. switch Output Control switch in the in the desired OFF/ posi (see Section 5-6). 6.1. GAS METAL ARC (GMAW) AND FLUX CORED ARC WELDING (FCAW) 6. WARNING: Read and follow safety Informa tIon at beginning of entire SectIon 6 before 7. Rotate the ARC CONTROL to the 8. Wear dry insulating gloves and clothing, and wear welding helmet with proper filter lens according to a 1. proceeding. Install and connect unit according to Section 4. OM-126 853 Page 14 Rotate the applicable OUTPUT Control (panel or to the desired position (see Section 5-3). remote) ANSI Z49.1. zero. Prepare 9. for welding as - follows: 8. Rotate the ARC CONTROL/INDUCTANCE CON TROL to the desired position (see Section 5-4). 9. Wear Connect work clamp to clean, bare metal at a. workpiece. b. Select and obtain proper tungsten electrode. c. Prepare tungsten electrode and insert into ANSI Z49.1. 10. torch. 10. Turn on cable. shielding gas and water supplies as dry insulating gloves and clothing, and wear safety goggles with correct filter shade according to appli Prepare for welding as follows: Connect work clamp to clean, bare metal at a. workpiece. b. Select and obtain proper welding wire, and thread as instructed in wire feeder Owners Manual. 11. Press the POWER switch ON button. 12. Begin welding. Select and obtain proper flux, and put into flux c. SHIELDED METAL ARC WELDING (SMAW) 6-3. a WARNING: Read and follow safety Informa tion at beginning of entire Section 6 before proceeding. system. 11. Turn on flux to Section 4. Place the CONTACTOR switch in the ON 3. Place the CV/CC switch in the CC Place the 4. tion Output Control switch position. position. in the desired posi AIR CARBON ARC CUTTING AND -GOUGING (ACA) 4A Rotate the remote) 6. to applicable OUTPUT Control (panel or the desired position (see Section 5-3). proceeding. Install and connect unit Rotate the ARC CONTROL to the desired position dry insulating gloves and clothing, and wear welding helmet with proper fllter lens according to Connect Place the CV/CC switch in the desired Section 5-7).. 4. Place the Output Control switch in the desired tion (see Section 5-6). 5. Rotate the remote) 8. Prepare for welding a; b. as follows: posi applicable OUTPUT Control (panel or position (see Section 5-3). to the desired Rotate the ARC CONTROL/INDUCTANCE CON TROL to the desired position (see Section 5-4)~. workpiece. 7. Place the CONTACTOR switch in the ON positi~on. Select and obtain proper electrode, and insert into electrode holder. 8. Wear Press the POWER switch ON button. 10. Beginwelding. dry insulating gloves and clothing, and wear welding helmet with proper filter lens according to ANSI Z49.1. 9. SUBMERGED ARC WELDING a position (see 6. Connect work clamp to clean, bare metal at 9. 6-4. supply to torch air hose. 3. Wear ANSI Z49.1. compressed to Section 4. according air 2. (see Section 5-4A). 7. WARNING: Read and follow safety Informa tion at beginning of entire SectIon 6 before (see Section 5-6). 1. 5. applicable. Begin welding. 6-5. 2. as 12. Press the POWER switch ON button. 13. according Install and connect unit 1. supply valve Prepare cutting Connect work a. (SAW) for gouging as follows: clamp to clean, bare or metal at workpiece. WARNING: Read and follow safety informa tion at beginning of entire SectIon 6 before Select and obtain proper carbon electrode, and insert into torch. b. proceeding. 10. Press the POWER switch ON button. to Section 4. 1. Install and connect unit 2. Install and prepare wire feeding system according to its Owners Manual. 3. Install flux system 4. Place the CONTACTOR REMOTE position. 5. Place the CV/CC switch in the desired Section 5-7).. 6. Place the Output Control switch in the desired tion (see Section 5-6). according 11. 6-6. 1. 7. Rotate the remote) according to its Owners switch in Manual. the position (see posi SHUTTiNG DOWN Stop welding or cutting. Press the welding power source POWER switch OFF button. 3. applicable OUTPUT Control (panel or position (see Section 5-3). to the desired 2. OFF/ Begin operation. Turnoff the cable. a WARNING: HIGH CONCENTRATION OF SHIELDING GAS can harm health or kIll.. S 4. shielding gas and water supplies if appli Shut off gas Turn off flux supply when supply and not in use. compressed air supply if applicable. OM-126 853 Page 15 SECTION 7.- MAINTENANCE & TROUBLESHOOTING C. ROUTINE MAINTENANCE (Table 7-1) 7-1. Every six months inspect the labels on this unit for legibility. All precautionary labels must be maintained in a clearly readable state and replaced when necessary. See Parts List for part number of precautionary labels. IMPORTANT: WARNING: ELECTRIC SHOCK can kill. Do not touch live electrical parts. Shutdown welding po wersource, and discon nect input power employing locko ut/tagging pro cedures before inspecting, maintaining, Internal a of pad line disconnect switch in open position, removing fuses from fuse box, or shutting off and red-tagging circuit breaker or other disconnect ing device. Keep HOT SURFACES . can cause serious 7-2. OVERLOAD PROTECTION 4A inspecting, maintaining, Injury. Consist of pad line disconnect switch in open position, removing fuses from fuse box, or shutting off and red-tagging circuit breaker or other disconnect ing device. Lockout/tagging procedures locking burns. servicing. cooling period performed only by qualified INCORRECT FUSE A. Units in heavy service environ month. Check labels, weld cables, clean internal parts. 3 months. Check weld cables (see Section 7-1B). 6 months. Check all labels (see IMPORT ANT block, Section 7-1). Clean internal parts (see Section7-1 C). Frequency of service is based on units operated 40 hours per week, Increase frequency of maim enance if usage exceeds 40 hours per week. A. damage unit. Maintenance ments: Every can Use only replaceme ntfuse of same size, type, and rating (see Parts List). Table 7-1. MaIntenance Schedule Every orseri icing. persons. Every kill. Do not touch live electrical parts. cedures before Maintenance to be Frequency can Shutdown welding powersource, and discon moving parts. can cause severe WARNING: ELECTRIC SHOCK nect input power employing locko ut/tagging pro before Allow proceeding. Every six months blow out or vacuum dust and dirt from the inside of the welding power source. Do not remove the outer enclosure, but blow a clean, dry airstream through the cabinet lovers. U dusty or dirty conditions are present, clean the unit monthly. locking away from WARNING: Read and follow safety Informa beginnIng of entire Section 7-1 before tion at orserv icing. Lockout/tagging procedures consist MOVING PARTS Cleaning Main Fuse Fl a (Figure 7-1) WARNING: Read and follow safety Informa tlon at beginning of entire Section 7-2 before proceeding. The unit is protected from overload by fuse Fl located on the center panel. if fuse Fl opens, the unit will be com pletely inoperative. To replace Fl, proceed as follows: 1. Remove the unit top 2. Check Fl, and replace if necessary. 3. Reinstall unit top B. Control Circuit Fuse F2 (Figure 7-1) cover. cover. Fan Motors This unit is equipped with two exhaust fans and relies on forced draft for adequate cooling. The fan motors are manufactured with lifetime sealed bearings and require no maintenance. B. Weld Cables a WARNING: Read and follow safety Informa beginning of entire SectIon 7-1 before tlon at proceeding. Every three months inspect cables for breaks in insula~ Repair or replace cables if insulation breaks are present. Clean and tighten connections at each inspec a WARNING: Read and follow safety informa tion at beginning of entire Section 7-2 before proceeding. The power source rectifier SRi is protected from over load by fuse F2 located behind the lower left portion of the front panel. Should F2 open, the CV/CC and CONTACTOR switches would not work. To replace F2, proceed as follows: 1. Remove left side 2. Check F2, and replace if necessary. 3. Reinstall left side panel. tion. tion. OM-126 853 Page 16 panel. Fuse Fl Unit Front Panel input Terminal With Input Voltage Label Jumper Links Strip iT, Jumper Links Terminal With Fuse F2 Located ~ehlnd Front p,:aflSi Near Lower) Left Side TB-096 9i37.4 / /I Figure 7-1. Component LocatIons / C. (Circuit /~ a Breaker CBI(Flgure 5-1) WARNINGS Read and follow safety Informsdon at beginning of entire Section 7-2 before 7-4. CIRCUIT BOARD INDICATOR LIGHTS a WARNING: ELECTRIC SHOCK MOVING PARTS can cause Injury. can kill; Do not touch live electrical parts. proceeding. Keep away from moving parts. Circuit Breaker CB1 is an automatic-trip type breaker and is not manually operable. When the circuit breaker button is in (ON position), the circuit breaker is function al. When the button is out (OFF position), the breaker is open and not functional. If CB1 opens when equipment use begins, a fault is probably present in the equipment. If CB1 opens after prolonged equipment use, an overload condition is prob ably present. Should CB1 open, locate and correct the problem, and manually reset CB1. 7-3. THERMAL PROTECTION Two normally closed thermostats TP1 are provided on the unit. One of these thermostats is located on each transistor module heat sink. A normally closed thermo stat TP2 is provided on the output diode heat sink. All three thermostats are wired in series with the main con tactor W coil. If any heat sink becomes too warm, the re spective thermostat opens, W contacts open, and the unit completely shuts down (thermal overload). The thermostat(s) automatically close when the unit cools down. After a cooling period, press the POWER switch ON button to resume operation. Only qualified persons familiar with ing standard safety practices are maintain, or and follow to inspect, service.this unit. uses fiber optics fortransmitting control circuit ry signals. The light wavelengths used are visible to the human eye. There is one unnumbered fiber optics cable from the control circuit board PCi to each of the four indi vidual base drive boards PC2 and PC3. This unit Each of the four base drive boards PC2 and PC3 are a red indicator light LED 50. The light will be on when the contactor is energized and the pulse width modulatorchip on PCi is operating. It is normal for the LEDs 50 to be on during welding. The brightness of the LEDs is proportional to machine output, and all LEDs at any given time should .have the same relative equipped with brightness. balance circuit board PC5, located next to main control circuit board PCi, is equipped with a red in dicator light LED1 This light is normally off during opera tion. LED I only turns on when operating on 460 volts in put power and a transistor module voltage imbalance occurs. If LED 1 is on, no machine open-circuit voltage Additionally, . will be available when the contactor is energized. OM-126 853 Page 17 CIRCUIT BOARD HANDLING PROCEDURES 7-5. a WARNING: ELECTRIC SHOCK can 7-i. TROUBLESHOOTING (Table 7-2) a kIll. Do not touch live electrical parts. can kill. Do not touch live electrical parts. Shutdown welding powersource, and discon n~ctinputpoweremploying locko ut/tagging pro gey#ures before inspecting, maintaining, orseri ~ Shutdown welding powersource, and discon nect input power employing locko ut/tagging pro cedures before inspecting, maintaining, orserv icing. WARNING: ELECTRIC SHOCK icing. LoCkC~utJtagging procedures k~ckin~ line disconnect switch consist of pad in open position, removt~,g fuses from fuse box, or shutting off and red-tag~jng circuit breaker or other disconnect - consist of pad in open position, 1removing fuses from fuse box, or shutting off and red-tagging circuit breaker or other disconnect Lockout/tagging procedures locking line disconnect switch ing devke. MOVING ARTS ing device. can cause serious Injury. Keep awqy from moving parts. HOT SURFAC~ 4A (ESO) can Put FORE on damage circuIt boards. properly grounded wrist strap BE Perform work only at a static-safe work area. INCORRECT INSTALLATiON can damage mIsaligned or circuit board. Be sure that plugs are properly installed and aligned. EXCESSIVE board. PRESSURE can break circuIt only minimal pressure and gentle move disconnecting or connecting board plugs and removing or installing board. Use ment when Table 7-2. be servicing. performed only by It is assumed that the unit was proper4y installed accord ing to Section 4 of this manual, the o~,erator is familiar with the function of controls, the power source was Working properly, and that the troub~le is not related weldi~ig to the welding process. The following table is designed to diagnose and provide remedies for some of the troubles that may dEwelop in this welding power source. Use this tablein con~jnction with the circuit diagram while performing troubIe~shoot ing procedures. If the trouble is not remedied after~ per forming these procedures, contact the nearest Fac~ory Authorized Service Station. In all cases of equipm~nt malfunction, strictly follow the manufacturers proce~ dures and instructions. Troubleshooting PROBABLE CAUSE TROUBLE No weld Troubleshooting qualified persons: to burns. handling circuit boards. Transport circuit boards in proper staticshielding carriers or packages. plugs Allow cooling pe:.:~~ before ELECTROSTATIC DISCHARGE CAUTION: can cause severe REMEDY output; unit completely Une disconnect switch in the Place line disconnect switch in the ON inoperative;piIot light PLI not on. ~ OFF position. position. Line fuse(s) open. Check and Improper electrical nections. input con- See Section connections. Check W Contactor W. replace line 4-4 fuse(s). for proper input points for wear, and replace points if necessary. Fuse Fl open. . Unit Check and replace Fl if necessary (see Section 7-2). caused Allow unit overheating TP1 and/or TP2 thermostat(s) to open (thermal shutdown). . to cool down (see Section 7-3). No weld output; unit completely Line voltage too high or too low Contact local electric utility to check inoperative; pilot light PL1 on. (–10% is maximum fluctuation correct line voltage problems. and tolerated). Transistor imbalance. module voltage Check status of LED 1 on PC5 according to Section 7-4, and contact factory Service ~ ~ OM-126 853 Page 18 Department. Table 7-2. Reduced output voltage; only onehalf of unit output voltage available; one transistor module inoperative, Input Troubleshooting (Continued) voltage jumper connected for incorrect links See Section 4-4 for proper connections. input voltage. Poorand/orimproperinputand/ See Sections 4-4 and 4-3 and output connections. output connections. for proper input or Base drive circuit board(s) PC2 and/or PC3 inoperative. Check status of LEDs on PC2 and/or PC3 according to Section 7-4, and contact factory Service Department. I mproperfiber optic connection. Contact - Erratic or improper weld output incorrect welding cable size. factory Service Department. Use proper size and type of cable (see Section 4-3). Loose or dirty welding cable connections. Clean and tighten all welding Poorand/orimproperinputand/ See Sections 4-4 and 4-3 and output connections. output connections, connections. for proper inpult or . Improper wire feeding setup, applicable. if See installation Section Owners Manual. in wire feedeir CV/CC CONTACTOR and switches inoperative. Fuse F2 open. Check and replace F2 if necessary (see Section 7-2). Reduced output voltage; only onehalf of unit output voltage available, Base drive circuit board(s) PC2 and/or PC3 inoperative, Check status of LEDs on PC2 and/or PC3 according to Section 7-4, and contact factory Service Department. OM-126 853 Page 19 NOTES OM-126 853 Page 20 SECTION 8- ELECTRICAL DIAGRAMS ~R2 / START ~ COO / LIO5 C., P30 POWER c~4 2300) / 3 1~ C21 ~ ~LE2 L2C 0 4600 I z C24 COO 230) A ~ If. L3O )~.LE E ~ TEl C21fl COO I~j C) (5 II! TI 9 -- ~. 5/ I _.Aic 0 pTc9 PC5 44 0 ~ RCS* C cc - ______ ~4SI0 _4z_L<< 2300. I ~flII C 12 I ~ LErT~j02j1~103 4600 ~~2~STTFeL 29 Bz 2200. I PC2 tE2 C I>>05I so ( TRANSISTOR ~06~j 1 R(GHTf~ ~9~ ~!k~ : C I TE2 II : ~.J>>o~i 30I9UT 0I~ )EATSITS. 9*09 ~ 2! C MODI ILE~ 1~ IE~~ JTI~ r1 I I fl9cJ l~ I-– ((SPEW) ~ ~0I2 E C*03 (5 BOARD C) (5 ~OI3 A ____________ ~0I TRAIGISTOW )ATSOM(S C-) 2 ~: _~ = = = 025 = = = = = = = = = = = = = = = = _________ IC: ~E~j~j rneHT~9~OA I~I ~I ~C~RI II - 026 - C I AR ~i(l,lEl.IE 2 TRANSISTOR MODULE 2 E~__ ~0I7 Ii :c t;; I>>~ = = - C I = = (LOWER) C.) ~g 1~ POSITIVE IS C) (5 ______ I _____ -~ ~OWj~jt 4~ irir P1 JPCS2BI TI--lI C! o- 1/!, -~-co-~--2--~ I F ~ II ~~JI AR IL cat I (9,4 PiLiRiEiPlI __________________ El I NEGATIVE ______ RIo I TO ,~CI I pCS _____ b~1L~J /5 TO ~I ~45V.~( ~ CR2 ~vi I~<<ARCACRCC~CSCF _____________ ~11 CST _______ O to TCGATOVE ~ I ~r I ~ 50 TARS I O27~ a 6 ~.A ____ A-P 10 TOACOC CA-CF TO PCI K>> RCSI 0404 I AS ~ ________ ______________ _____________ -~ ~ SO o AC LED 221.U. TO 051 09 PC2 ITRARDISTOW LED oo4.- 10091 09 PCO (191) TO DPI 09 PC2 (193) To 051 09 PC3 (lAS) RC52 (FIRER SRTICS) LED -<<RI-OAR. TO, S >)~- ( I J I CI6 __________ S1PL 68 4WP. r<<~~ I F,j I _______________ I-! BC FP!CT!OW ( -<<A(2*0.I ~ I SR PA I I 0 9 0 AC RMTI~W DJTPIJT ~ AH._~::~.:l~__S. ARC I~.J..E I C09~/ LEADS FR~I ARCPRR 1ST 49 0 /20 0 /09 ..0 3) /i! I 32 ~ 2 6 301076 55 0 76 s, o ,, 2010 rfi2~ 21 DC. cv OM-126 853 Page 21 .?~ V. AA-AH ON PC5O A-P ON PC~I CA-CF ON PC52 I F~ cw ~.npuT C3~TP~. ~ V~.TAG cv .I~ V. -I~ V. Diagram OM-126 853 Page 22 8-2. Circuit Diagram For Control Circuit Board PCi .15 V. ~ I~V .15 V. Cu 10 *1, ~ ~_:~ ~ ~CU V. V. I5 V. ~ ~C64 I.~2 039 ~e .1! 037 ~63I4I5 -. 052 051 23 15V..ISV. -, f~I 22 1~1 L11 1J U5 I S I0 20 ~~8D~0 I C 26 V. .15 039 03* -....)~ ~ 2 2 V60 U52 038 036 C70 ~AOE I~L. V~TAG ~jPI C72 9V80 FRICTI00 r~ TABS - ~ - - - rr -- -4; C99 ~A5965 CII Dl 8 5 13 21.1871 19 2312 2622 II 9 57 I~~T0L~J ¶~ 010 CIA L 859 58 *0.i. 02 CV ~HXNY L~J~ cc 552 C73 1~15 1F605 ICAIl. L1~ ! 05 IV 2 .15 300 A51 + CIOl ~ 6 144 - ~JTY CV ~E - C93~~ .15 ~ 1.1 1 V. 6F -I. , L2 ARC :1 c~4TRU_/ ITOCTANcE ~ ~I3 1C12 80 >5 I F#E~00CV ~~i .;31] do CW SCM~E ~SV~ .15 V. C92 .18 3 2 r+A9 #8 73 .15* V. IS V *57 3 + 3 ID ~ ~3 ~L6 7 053 657 15 C16 .15 V. + cc s5I I0O~~II .15 V. 5 6O~~~7 * C91 8* o~ 5 -IS + 7 15 V. *62 ______________________________________ 6 8 081 cie Circuit Diagram No. D-119 151 OM-126 853 Pa~e 23 .12 V. I -by. a -12 V. c6o -12 -2 V. 12 V. V. 065 -12 V. C Circuit Diagram No. B-122 636 Diagram 8-3. Circuit Diagram 48 (C 25 (A 53 (B For Base Drive Circuit Boards PC2 And PC3 IRlo )I 1R211 1R22 45 Circuit Diagram No. A-123 501 Diagram OM-126 853 Page 24 8-4. Circuit Diagram For Snubber Circuit Board PC4 687 B-107 A No. Diagram Circuit Isv. - PC5 Board Circuit Balnce For Diagram CircuIt 8-5. Diagram FROM BOARD EXIT PC I ~ 15V. . lciiIs~ TCI2 ~ 3 ~ ~ ICI ~ ~CI4I £ D4,d I ~D2 j. D3 DI Rc04 < ON AD AC< AA( C DO A -AF A 0 rs 0) 0) 01 C.) -u (0 0 01 SECTION 9 PARTS LIST 9 >1 E Ce / OM-126 853 Page 26 IL Item No. Part No. Dia. Mkgs. Descnption FIgure 1 2 Zi 3 4 5 6 7 8 Cii ,2 TM1 ,2 RC5O 9 10 11 PCi 12 RC51 13 14 109005 098 451 010 116 09~ 462 Fig 9-3 096 659 122950 072 566 097 474 119219 080 509 081 380 096 430 1186730008626 +1065370008626 124 245 0345870008398 15 083 426 601 835 601 836 038 038 010 010 010 16 C1,2 . 17 18 19 - FM1,2 888 887 913 915 957 111 019 022 160 096 601 109004 124 175 120 131 20 21 22 23 24 25 26 27 28 117037 096 454 T2,3 124 419 124416 124 415 Ti 124 152 096427 Fig 9-2 098 173 096423 9-1. MaIn Quantity Assembly COVER,top 1 STABILIZER 1 GROMMET, rbr .375 ID x .500 I BAFFLE, air BAFFLE, center w/components 1 TRANSFORMER, 2 . 1 current TRANSISTOR ASSEMBLY, main HOUSING, term header 8 pin CABLE, fiber optics w/plugs (Fig 9-4) 2 1 4 CIRCUITCARD,control GROMMET, scr No. 8/10 HOUSING, term header 14 pin PANEL, mtg circuit card 1 .5 1 1 PANEL,rear PLATE, cover terminal assembly LABEL, warning electric shock can kill etc TERMINAL ASSEMBLY, primary (consisting of) TERMINAL BOARD, primary NUT, brs hex 10-32 reg NUT, brs hex .250-20 jam hvy STUD, primary board brs .250-20 x 1.500 STUD, primary board brs 10-32 x 1.375 WASHER, fIat brs .187 ID x .500 OD WASHER, flat brs .250 ID x .625 OD TUBING, stl .500 OD x l7ga wall (mtg terminal assembly) CAPACITOR, elctlt 2500uf 45OVDC pair CLAMP, capacitor 3.000 dia 1 1 1 1 1 6 2 I 3 3 2 2: 1 2 BRACKET, mtg fan motor PANEL,sideRH FAN, motor 230V50/60 Hz (consisting of) HOUSING, plug nyl 2 contacts HOUSING,termheater2skt BRACKE1~ mtg transformer 2 1 TRANSFORMER, power main 320 (consisting of) COIL, pri/sec 320 bottom COIL, pn/sec 320 top TRANSFORMER, KVA 1/2 115-230-2301230-4 2 BASE 1 2 ii 2 2 PANEL, front w/components DIODE MODULE (Fig 9-2) PANEL,sideLH +When ordering a component originally displaying a precautionary label, the label should also be ordered. BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS. OM-126 853 Page 27 913 TC-13 ~15 14 ii::: 21 22 \ 29 W/Compnets Front Pane, 9-2. Figure 0 M cli (.3 -o 3 Item No. Dia. Part Mkgs. No. FIgure 9-2. Panel, Front W/Components (Fig 097 922 126 600 0937270008398 1 2 3 4 5 R28,29 6 S1-3 7 8 9 10 11 lOT CB1 R31 TD1 12 13 CR3 14 R30 PB1 15 16 17 18 19 20 21 Cl 0,11 22 23 24 25 26 27 28 29 30 31 32 33 34 HD1 SR1,2 35 36 R25 37 38 C16,17 F2 39 40 41 42 R26 43 C6 44 45 PL1 035 897 011 609 1224460008398 038 782 011 991 030 047 047 133 1224420008398 108 358 030087 105 572 081 008 090 354 018 606 027 878 059 885 087 209 039 047 039 046 601 976 039 049 039 045 601 880 039 044 601 879 +118671 0008625 106353 121316 108 830 035 704 ~72 253 090 476 601 394 000 859 *012 643 093 376 010 311 099 596 601 934 031 613 010610 048 573 Quanflty Descnption 9.1 Item 26) KNOB, pointer PLATE, control panel PANEL, mtg components NAMEPLATE, (order by model & serial number) POTENTIOMETER, C sltd 5ff lIT 2W 1K ohm SWITCH, tgl SPDT 15A 125VAC BRACKET, mtg block terminal BLOCK, term 20A lop CIRCUIT BREAKER, man reset 1 p 1 .5A 250V RESISTOR, C .5W 39K ohm RELAY, delay adj 120 VAC DPDT BRACKET, mtg relay 2 CONTACTOR, def pip 25A 2P 24VAC coil 1 RESISTOR,WWfxd25W200ohm SWITCH, pb (consisting of) BRACKET, mtg switch PUSH BUTTON SET, w/cable & housing SPRING, compression SWITCH, limit leaf actuating SPDT BUTTON, push reset red ii CAPACITOR, disc .OO3uf 2000VAC TERMINAL, pwr output red (consisting of) TERMINAL, pwr output black (consisting of) SCREW, cap hex hd 1/2-13 x 1-1/2 TERMINAL BOARD, red TERMINAL BOARD, black NUT, hex jam 1/2-13 BUS BAR NUT, hex full 1/2-13 PANEL, front 2 SENSOR,current LABEL, warning general precautionary BRACKET, mtg rectifier 1 RECTIFIER, integrated 30A 600V STUD, gid 10-32 x 1/2 CAPACITOR ASSEMBLY, (consisting of) RESISTOR, C 2W 10K ohm CAPACITOR, elctlt 220uf 35V0C FUSE, minat gi sb bbo 1A HOLDER, fuse minat CLAMP, nyl .875 clamp dia x .500 CAPACITOR ASSEMBLY, (consisting of) RESISTOR, C 2W 10K ohm CAPACITOR, elctit lOOuf 15OVDC 2 1 1 1 2 3, 1 1 1 1 I 1 1 - 1 cer 1 1 1 1 1 1 . CONNECTOR,clamp 1 1 1 1 1 I 1 :2 1 1 1 1 1 1 cable .500 1 LIGHT, md red lens 28V 1 +When ordering a component originally displaying a precautionary label, the label should also be ordered. *Re~mmended Spare Parts. BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS. OM-126 853 Page 29 N U, C C, C 0 a. E 0 C) OM-126 853 Page 30 Item No Dia. Mkgs. Part No. Description Figure 1 081 016 2 082456 070250 098975 034896 057358 *012639 070 404 108831 107597 096517 096759 080509 3 4 025,26 R23,24 Wl1,2 5 6 7 Fl 9 10 PC5 11 12 13 9-3. Battle, Center Quantity W/Components (Fig 9-1 Item 5) BRACKET, mtg DIODE ASSEMBLY, (consisting of) DIODE, 3A 600V RESISTOR,WW fxd 1 OW 500 ohm INTERLOCK, cntor NC BUSHING, snap-in nyl 1.000 ID x 1.375 mtg hole FUSE, crtg 6A 600V HOLDER, fuse crtg ANGLE, mtg components CIRCUIT CARD, balance 1 1 2. 1 2 1 1 1 1 1 HEAT SINK WEATHERSTRIPPING, adhesive rbr 1/2 GROMMET, scr No. 8/10 panel hole 1 x 1/2 (order by ft) 2rt 4 14 PMI-3 095279 DIODE, power module 55A 1400V 3 15 16 17 C20-25 087 337 096606 118 153 015712 015 722 038 639 038620 120 561 027811 026 202 027810 108842 096 463 038 887 601 835 010913 CAPACITOR, cer disc .OO3uf 3000 VAC BUS BAR, jumperpri BAFFLE, center GROMMET, rbr .625 ID x .875 mtg hole GROMMET, 1-1/4 ID x 1-1/2 mtg hole 6 2 18 19 TE2 20 21 D27 22 23 CR2 TEl 038 618 026 754 24 R1,2 25 26 27 28 W 098864 079 844 048 029 603 097 111 461 028 982 *003 567 4 BLOCK, term 30A 6P LINK, jumper 2 CONNECTOR, term block 20A SOCKET, relay 10 DIODE, 1A400VSP RELAY, end 24VDC 4PDT TERMINAL ASSEMBLY, pn iph 2V (consisting of) TERMINAL BOARD STUD, brs No. 10-32 x 1-3/8 NUT, brs hex 10-32 WASHER, flat brs 3/16 ID x 1/200 4 8 4 LINK, jumper 2 INSULATION, pri stud barrier 4 RESISTOR, WW fxd low 20K ohm SPRING, hoiddown relay CLIP, retaining socket relay 2 GROMMET, rbr .84310 x 1.250 mtg hole CONTACTOR, 50A 3P 1 20V (consisting of) 1 COIL 1 KIT, point :3 Recommended Spare Parts. BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS. OM-126 853 Page 31 4, 1 16 11 19 Ret. TD-091 114-9 Figure OM-126 853 Page 32 9-4. Transistor Assembly, Main Item No. Dia. Part Mkgs. No. 1 . 2 Qi-lO 3 4 5 6 7 PC2,3 8 TP1 9 10 Dl ,3 11 12 R3,7&8,9 13 14 R13-20 15 C3,5,12,13,18,19 16 17 . - 18 29 . -. Quantity Description 9-4. Transistor 098 335 Figure 122949 096 769 122 931 122776 122 930 126 102 122920 098 691 032 810 096 766 095 254 096 770 125 844 113 781 126 109 074 111 098 325 126 108 122 923 098 219 094 300 098 252 098 253 098 254 098 255 010 885 MODULE, (consisting of) Assembly, Main (Fig 9-1 Item 7) 2 2 BUS BAR, driver board to collector bus bar BUS BAR, emitter 2 ~TRANSISTOR,NPN3OA850V HEAT SINK, transistor CIRCUIT CARD, base drive BAFFLE, air STAND-OFF, No. 6-32 x 1/2 THERMOSTAT, NC 10 1 . 2 . 1 . . . . . . 4 1 BUS BAR, diode to emitter bus bar DIODE, 30A 300V BUS BAR, drive board to emitter bus bar 2 RESISTOR ASSEMBLY, (consisting of) RESISTOR, C 2W lOOK ohm BUS BAR, diode to collector bus bar RESISTOR, C 2W 47 ohm CAPACITOR, poly film .027uf 630V 2 2 4 2 . 1 4 6 BUS BAR, collector ANGLE, mtg heat sink BAFFLE, air & cable support BUSHING, snap-in 5/8 OD x 1/2 ID BUS BAR, cap to emitter 3/16 x 3/8 x 4-3/8 BUS BAR, cap to emitter 3/16 x 3/8 x 5-1/8 BUS BAR, cap to collector 3/16 x 3/8 x 4 BUS BAR, cap to collector 3/16 x 3/8 x 3-3/4 STRIP, conductor .031 x .375 x 5.375 2 2 1 4 1 1 1 1 1 BE SURE TO PROVIDE MODEL AND SERiAL NUMBER WHEN ORDERING REPLACEMENT PARTS. OM-126 853 Page 33 Item No. Dia. Mkgs. 1 2 3 4 5 6 7 D9-24 TP2 8 PC4 9 10 Part No. Quantity Desciiption 098173 FIgure 9-5. Module, Diode (Fig 026947 096 604 096603 096421 095 251 032810 052413 098 154 098 691 038328 STAND-OFF, 1/4-20 x 1 ANGLE, mtg heat sink diode STRIP, mtg components HEAT SINK, diodes DIODE, 70A 400V THERMOSTAT, NC STUD, brs 1/4-20 x 7/8 CIRCUIT CARD, snubber STAND-OFF, No. 6-32 x 1/2 STUD, brs 1/4-20 x 1-1/4 9-1 item 27) 4 2 2 1 16 1 4 1 2 2 6 TC-097115-8 FIgure 9-5. Module, Diode BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS. OM-126 853 Page 34