Transcript
9 Fault finding 9 Fault finding The tables below provide information on possible faults when the solar heating system is being operated, information on their causes and how to rectify them. All work on the Vaillant solar heating system (installation, maintenance, repairs etc.) may be performed only by approved competent persons. a Danger! Risk of death from electric shock! Improperly executed work on the solar heating system can result in risk to life and limb. > Faults may only be eliminated by a competent person approved at the time by the Health and Safety Executive. b Caution! Risk of damage due to overheating! Not all electric immersion heaters have a thermal cut-out. > Use only Vaillant Ltd. electric immersion heaters with a thermal cut-out as replacement parts. Fault i We recommend entering into a maintenance agreement. Cause Solar pump The solar pump doesn't work even though 1. No current available. the collector is warmer than the cylinder. 2. Temperature difference set too high (neither motor noises can be heard nor or controller is not switching. vibrations felt). 3. Maximum temperature reached. 4. The solar pump shaft is blocked by deposits on the bearings. 5. The solar pump is dirty. 6. Solar pump is faulty. 7. The flow rate is not set correctly. The solar pump is running but no solar Air is in the pipe system. fluid is flowing from the collector (the solar pump is getting hot). Forward- and return flow temperatures are the same or the cylinder temperature is not increasing at all or only slowly. The solar pump kicks in late and stops early. When replacing parts, use only original replacement parts from Vaillant Ltd. Remedy Check the power cable and fuses. Check the controller. Check the temperature sensors. Reduce the temperature difference. Switch temporarily to max. speed or unblock the rotor, insert a screwdriver in the notch and turn it by hand. Dismantle and clean the solar pump. Close the flow rate limiter and pump ball valve. Replace the solar pump. Check the setting and adjust if necessary. Check the system pressure. Operate the solar pump intermittently at maximum output. Open the air vent on the solar pump and open and vent the cylinder. Vent the backflow preventer. If there is no improvement, check whether there is a "u pocket" anywhere in the piping (e. g. at beam projections or at the bend of water pipes). Change the pipe routing or install additional air vents. if the system has already been commissioned and is refilled again, check the automatic air vent: Unscrew the protective cap and check the float using a blunt pin to make sure that it can move freely. If the floater is jammed, change the air vent. 1. The temperature difference between Reduce the temperature difference. the collector and cylinder has been set too high. 2. Collector connection pieces not insulated Insulate the collector connection pieces. (tube collector). Table 9.1 Troubleshooting 62 Instructions on commissioning, maintenance, and troubleshooting for auroSTOR 0020111119_02