Download Micom 3T Specifications
Transcript
Maintenance Maintenance Error Messages MICOM-H Owner’s Guide No. Description 00 O.K. - no errors 01 DSP boot checksum fail (download) 02 DSP PLL unlock 03 DSP external RAM memory 04 (Not applicable) 05 DSP internal RAM memory 06 (Not applicable) 07 (Not applicable) 08 HC16 flash memory checksum 09 HC16 RAM memory 10 No 16.8 MHz clock 11 Battery low 12 Control head wake-up 13 Control head is not responding 14 Radio not programmed 15 Database fail 16 VCO 1 first injection 17 VCO 2 first injection 18 VCO 3 first injection 19 VCO second injection 20 Synthesizer unlock 21 Receiver failure 22 Preselector range 1 23 Preselector range 2 24 Preselector range 3 25 Preselector range 4 26 Preselector range 5 27 Preselector range 6 28 Preselector range 7 29 Preselector range 8 30 Exiter test 31 Antenna mismatch 32 Harmonic filter range 1 33 Harmonic filter range 2 34 Harmonic filter range 3 35 Harmonic filter range 4 36 Harmonic filter range 5 37 Harmonic filter range 6 38 Harmonic filter range 7 39 Power amplifier fail 48