Transcript
Ribbon Tubes & Shaft Support Preparations The exterior cover must be removed prior to proceeding. (980428-101) Take-Up Ribbon Tube Or Shaft Support Housing - The ribbon belt and pulley must be removed from the tube shaft prior to preceding. (980428-132) Supply Ribbon Tube Or Shaft Support Housing - The ribbon supply collar and spring must be removed from the tube shaft prior to preceding. (980428-138) Nylon Bearing Take-Up Ribbon Tubes Supply Tools: #2 Philips screwdriver Removal 1. With the collar or pulley removed, slide the ribbon tube out of the shaft support housing. 2. Shaft Support Housing only - Remove the two (2) mounting screws securing the shaft support housing to the center panel. Installation 1. Shaft Support Housing only - Insert the two (2) nylon bearings into each end of the shaft housing. No lubrication is needed. 2. Shaft Support Housing only - Insert the housing into the center panel. Rotate the housing to align the two (2) molded posts. Attach the housing to the center panel with two (2) screws. 3. Place the nylon washer on the shaft and push it against the tube assembly. 4. Slide the tube assembly into the shaft support housing and re-install the collar (supply) or ribbon belt and pulley (take-up). 54 980428-139 Rev. 1 Prelim.