Download Westerbeke 46 Operator`s manual
Transcript
I. Check condition of zinc anode in heat exchanger. Should material be flaking off the zinc, it should be scraped clean, or be replaced by a good solid zinc pencil. If it appears that a lot of material has been flaking off the zinc, then it is advised that the end cap of the exchanger be removed, and the flaked material be cleaned from that area of the exchanger. A new end cap gasket should be on hand in case it is needed when replacing the end cap. ZINC #11885 *J. 3. 4. 5. REPLACE CLEAN/REPLACE Check for proper movement and security of throttle and shift linkage. Servicing at every 100 hours of operation. A. Renewal of engine oil. B. Replacement of oil filter. Servicing at every 200 hours of operation. A. Replacement of engine mounted fuel filter elements. B. Relacement of fuel filter (cartridge type). Servicing at every 500 hours of operation. A. Adjustment of engine idle, if necessary. *B. Tightening of bolts and nuts. *C. Adjustment of valve clearance. 26