Download Maytag MDE25PN Specifications

Transcript
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Parts supplied:
Tools needed:
[]
[]
Foot boot (4)
Dryer foot (4)
[]
PD models: Cam for
service door lock
m 200 mm (8") or 250 mm
(10") Pipe wrench
m 8 mm (5/16") socket
wrench
m 200 mm (8") or 250 mm
m Utility knife
(10") Adjustable wrench
m Vent clamps
m Flat-blade screwdriver
m Phillips screwdriver
m Sealing compound gun
and sealing compound (for
m Adjustable wrench that
opens to 25 mm (1 ") or
installing new exhaust vent)
m Pliers
hex-head socket wrench
m Level
m Stiff-bladed putty knife
Remove parts bag from dryer drum. Check that all parts were
included.
[]
PN models: Card reader
bezel, card reader wire
harness, hardware
NOTE: The circuit diagram for this dryer is located inside the
lower front panel, within the Tech Sheets.
Technical
Specifications:
220-240 v, 50 Hz. AC
4575W
Total mass: 68 kg max.
Clothes Capacity:
9 kg max.
NOISE: Sound Pressure Level, Lpa: 58 dBA (uncertainty,
Kpa: +/-10 dBA).
If installed in a closet with a door, the minimum unobstructed
opening in the top and bottom is required. Louvered doors
with equivalent air openings are acceptable.
air
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same
closet as the dryer.
Minimum Installation
Explosion
Hazard
o
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Failure to do so can result in death, explosion,
I
(:1
I
Closet
door
Ornrn
Check code requirements: Some codes limit or do not permit
installation of clothes dryers in garages, closets, or sleeping
quarters. Contact your local building inspector.
J
C14'') max
or fire.
IMPORTANT: Observe all governing codes and ordinances.
[]
356 mm
o
381 mm
Os")
Do not install in a garage.
[]
Clearances
_
Ornrn
CO") _
! .... ]
''
_
Omm
(0")
CO")
_1 ]_2s mm 11")
Closet side view
Recessed front view
Do not install on carpet.
NOTE: The dryer must not be installed in an area where it will be
exposed to water and/or weather.
Additional clearances may be required for wall, door, and floor moldings or if
external exhaust elbow is used.
L
Recessed
Area
and Closet
Installation
Instructions
This dryer may be installed in a recessed area or closet. This
dryer must not be installed behind a lockable door, a sliding door,
or a door with a hinge on the opposite side to that of the dryer.
The installation spacing is in millimeters and is the minimum
allowable. Additional spacing should be considered for ease
of installation, servicing, and compliance with local codes
and ordinances.
76 mm (3")
+
(48 in._)
Front
view
closet
0
door
(24 in._)
76 mm (3")
*Opening is the minimum
for a closet door. Louvered
doors with equivalent air
openings are acceptable.